1、Designation: D 6536 00 (Reapproved 2005)Standard Test Method forMeasuring the Dip Tube Length of a Mechanical PumpDispenser1This standard is issued under the fixed designation D 6536; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、 the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement technique fora dip tube of a mechanical pump dispenser.1.2 The v
3、alues stated in both inch-pound and SI units are tobe regarded separately as the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practic
4、es and determine the applica-bility of regulatory limitations prior to use.2. Significance and Use2.1 This test method is to be used to measure the length ofa specified dip tube from the bottom of the sealing surface tothe end of the dip tube in a mechanical pump dispenser.2.2 This test method is to
5、 be used to measure the exposedlength of a specified dip tube of a mechanical pump dispenser.3. Apparatus3.1 Thin Metal Ruler, with minimum gradients of 1 mm or116 in., or both, along with a zero index at the end of the ruler.3.2 Calipers.4. ProcedureTEST METHOD “A”MEASUREMENT OFOVERALL DIP TUBE LEN
6、GTHNOTE 1This test method is used when the exposed sealing surface ofthe mechanical pump dispenser is large enough to measure from.4.1 While holding the mechanical pump dispenser with itsaxis in a horizontal plane, place the zero index end of the ruleragainst the bottom of the seal surface. Fig. 1di
7、mension “X”.4.2 If needed, straighten the dip tube out so that it is parallelwith the length of the ruler.4.3 Measure the overall length of the dip tube to within afull millimetre or116 in. length.4.4 Record the length measured in 5.1.TEST METHOD “B”MEASUREMENT OF EXPOSEDDIP TUBE LENGTHNOTE 2This te
8、st method is used in all applications.4.5 While holding the mechanical pump dispenser with itsaxis in a horizontal plane, place the zero index end of the ruleragainst the bottom end of the body. Fig. 1dimension “Z”.4.6 If needed straighten the dip tube out so that it is parallelwith the length of th
9、e ruler.4.7 Measure the exposed length of the dip tube to within afull millimetre or116 in. length.4.8 Record the length measured in 5.1.5. Report5.1 Report the following information:5.1.1 Type of mechanical pump dispenser,5.1.2 Dip tube length measured, and5.1.3 Method used.6. Precision and Bias6.1
10、 PrecisionThe precision of this test method is within arange of plus or minus 1 mm or116 in. from the specifiedlength depending on the unit of measure used: millimetres orinches. An examination of the results of dip tube lengthmeasurements from _ technicians in one lab found that tenpumps measured u
11、nder Test Method “A” had a range in lengthspecified from _ in. long. Data is currently being gathered.6.2 BiasThis test method has no bias because an acceptedreference or referee value is not available.1This test method is under the jurisdiction of ASTM Committee D10 onPackaging and is the direct re
12、sponsibility of Subcommittee D10.33 on MechanicalDispensers.Current edition approved Oct. 1, 2005. Published October 2005. Originallyapproved in 2000. Last previous edition approved in 2000 as D 6536 00.FIG. 1 Overall Dip Tube Length “X” Versus Exposed Dip TubeLength “Z”1Copyright ASTM International
13、, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7. Keywords7.1 dip tube length; dip tube measurement; mechanicalpump dispenserASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this
14、standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be r
15、eviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of therespon
16、sible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West
17、 Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).D 6536 00 (2005)2
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1