1、Designation: D 7144 05aStandard Practice forCollection of Surface Dust by Micro-vacuum Sampling forSubsequent Metals Determination1This standard is issued under the fixed designation D 7144; the number immediately following the designation indicates the year oforiginal adoption or, in the case of re
2、vision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the micro-vacuum collection ofsurface dust for subsequent determination of m
3、etals. Theprimary intended application is for sampling from soft, rough,or porous surfaces.1.2 Micro-vacuum sampling is carried out using a collectionnozzle attached to a filter holder (sampling cassette) that isconnected to an air sampling pump.1.3 This practice allows for the subsequent determinat
4、ion ofmetals on a loading basis (mass of metal(s) per unit areasampled), or on a concentration basis (mass of metal(s) per unitmass of sample collected), or both.1.4 The values stated in SI units are to be regarded asstandard.1.5 LimitationsDue to a number of physical factors inher-ent in the micro-
5、vacuum sampling method, analytical resultsfor vacuum dust samples are not likely to reflect the total dustcontained within the sampling area prior to sample collection.Indeed, dust collection will generally be biased towardssmaller, less dense dust particles. Nevertheless, the use of thisstandard pr
6、actice will generate data that are consistent andcomparable between operators performing micro-vacuum col-lection at a variety of sampling locations and sites.21.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the use
7、r of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D 1356 Terminology Relating to Sampling and Analysis ofAtmospheresD 3195 Practice for Rotameter CalibrationD 484
8、0 Guide for Sampling Chain of Custody ProceduresD 5438 Practice for Collection of Floor Dust for ChemicalAnalysisD 6966 Practice for Collection of Dust Wipe Samples forSubsequent Metals Determination2.2 ISO Standard:4ISO 15202-1 Workplace airDetermination of metals andmetalloids in airborne particul
9、ate matter by inductivelycoupled plasma atomic emission spectrometryPart 1:Sampling3. Terminology3.1 DefinitionsFor definitions of terms relating to sam-pling and analysis of dust not given here, refer to D 1356.3.2 Definitions of Terms Specific to This Standard:3.2.1 air sampling pumpa portable pum
10、p that is used todraw air through a filter holder/collection nozzle assembly formicro-vacuum collection of surface dust. An example wouldinclude a personal sampling pump (D 1365).3.2.2 batcha group of field or quality control samples, orboth, that are collected together in a similar environment anda
11、re processed together using the same reagents and equipment.3.2.3 collection nozzlea piece of flexible plastic tubingcut at a 45 angle at the inlet end, and connected at the outletend to the inlet orifice of a filter holder (sampling cassette).3.2.4 field blanka sample that is handled in exactly the
12、same way that field samples are collected, except that no air isdrawn through it.3.2.5 filter holderan apparatus that supports and containsthe filter medium upon which dust is collected. It is also oftenreferred to as a sampling cassette.3.2.6 internal capsulea device inserted into a filter holder(s
13、ampling cassette) that allows complete capture of contami-nant within its envelope and prevents deposition of collectedmaterial on the internal walls of the sampling cassette. Use ofan internal capsule is necessary for gravimetric analysispurposes.NOTE 1Such capsules are commercially available.1This
14、 practice is under the jurisdiction of ASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee D22.04 on WorkplaceAtmospheres.Current edition approved October 1, 2005. Published October 2005. Originallyapproved in 2005. Last previous edition approved in 2005 as D 7144 - 05.
15、2Reynolds, S. J., et al., “Laboratory comparison of vacuum, OSHA, and HUDsampling methods for lead in household dust.” American Industrial HygieneAssociation Journal, Vol. 58, pp. 439-446 (1997).3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at
16、serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Bo
17、x C700, West Conshohocken, PA 19428-2959, United States.3.2.7 sampling device (assembly)for micro-vacuum sam-pling, an apparatus consisting of the collection nozzle, filterholder (containing internal capsule, if necessary), and airsampling pump, used to collect surface dust. The collectionnozzle is
18、attached to the inlet end of the filter holder. The filterholder houses the filter, through which air is drawn by using theair sampling pump. The filter holder is attached to the pump byflexible tubing.3.2.8 surface dustparticulate matter on a given surfacewhich has been transported to its present l
19、ocation by variousmeans, such as settling through the air or tracking from othersources.4. Summary of Practice4.1 Samples of surface dust are collected from selectedsampling locations into individual filter holders by using amicro-vacuum collection technique that employs a personalsampling pump.5The
20、 sample is then processed for transportand subsequent laboratory analysis for determination of metalscontent.4.2 The collected sample may include particles which ad-here to the internal walls of the filter holder. This materialshould be rinsed or wiped off and added to the sample meantfor subsequent
21、 chemical analysis. However, this materialcannot be included in gravimetric determination unless aninternal capsule that can be accurately weighed is used duringsample collection.5. Significance and Use5.1 Human exposure to toxic metals present in surface dustcan result from dermal contact with or i
22、ngestion of contami-nated dust.Also, inhalation exposure can result from disturbingdust particles from contaminated surfaces. Thus standardizedmethods for the collection and analysis of metals in surfacedust samples are needed in order to evaluate the potential forhuman exposure to toxic elements.5.
23、2 This practice involves the use of sampling equipment tocollect surface dust samples that may contain toxic metals, andis intended for use by qualified technical professionals.5.3 This practice allows for the subsequent determination ofcollected metals concentrations on an area (loading) or masscon
24、centration basis, or both.5.4 Because particle losses can occur due to collection ofdust onto the inner surfaces of the nozzle, the length of thecollection nozzle is specified in order that such losses arecomparable from one sample to another.5.5 This practice is suitable for the collection of surfa
25、ce dustsamples from, for example: (a) soft, porous surfaces such ascarpet or upholstery; (b) hard, rough surfaces such as concreteor roughened wood; (c) confined areas that cannot be easilysampled by other means (such as wipe sampling as describedin Practice D 6966).Acompanion sampling technique tha
26、t maybe used for collection of surface dust from hard, smoothsurfaces is wipe sampling (Practice D 6966). A companionvacuum sampling technique that may be used for samplingcarpets is described in Practice D 5438.5.6 Procedures presented in this practice are intended toprovide a standardized method f
27、or dust collection from sur-faces that cannot be reliably sampled using wipe collectionmethods (for example, Practice D 6966). Additionally, theprocedure described uses equipment that is readily availableand in common use for other environmental and occupationalhygiene sampling applications.5.7 The
28、entire contents of the filter holder, that is, the filterplus collected dust, is targeted for subsequent analysis formetals content. An internal capsule is used if gravimetricanalysis is necessary.6. Apparatus6.1 Dust sampling equipmentThe sampling assembly (seeFig. 1) for the micro-vacuum collectio
29、n of surface dust sampleshas the following components:6.1.1 Filters, of a diameter suitable for use with the filterholders, and with a collection efficiency of not less than 99.5 %for particles with a diffusion diameter of 0.3 m, and with avery low metal content (typically less than 0.1 g of each me
30、talof interest per filter) (see ISO 15202-1).6.1.1.1 Weight-stable filters or matched-weight filters shallbe used if it is desired to determine the mass of collected dust.NOTE 2If the filters are to be weighed in order to determine the massof dust collected, it is important that they be resistant to
31、 moistureretention, so that blank weight changes that can occur as a result ofchanges in temperature and humidity are as low and repeatable aspossible. Also, filters selected for weight stability should not be exces-sively brittle, since this can introduce weighing errors due to loss of filtermateri
32、al.6.1.2 Filter holders, for 25- or 37-mm diameter filters.6.1.3 Internal capsules, for gravimetric analysisIfitisdesired to determine the mass of collected dust, internalcapsules shall be weighed to the nearest 0.1 mg.NOTE 3If pre-weighed internal capsules and filters are used, it will benecessary
33、to tare the internal capsules, plus backup pads, prior to use.Procedures for accurate weighing of internal capsules are described indetail elsewhere.65Que Hee, S. S., et al., “Evolution of efficient methods to sample lead sources,such as house dust and hand dust, in the homes of children.” Environme
34、ntalResearch, Vol. 38, pp. 77-95 (1985).6NIOSH Manual of Analytical Methods, 4th ed.; Methods 0500 and 0600.Centers for Disease Control and Prevention, National Institute for OccupationalSafety and Health, Cincinnati, Ohio, 1994.FIG. 1 Schematic of Sampling Assembly for Micro-VacuumSurface Dust Samp
35、lingA: Flexible tubing connecting the filter holder to the samplingpump (not shown); B: Outlet of filter holder; C: Back-up pad/support; D: Filter; E: Inlet of filter holder; F: Housing of filterholder; G: Flexible tubing collection nozzleD 7144 05a26.1.4 Back-up pads, cellulosic; or metallic screen
36、 back-upsupport.NOTE 4If pre-weighed filters are used, it is not necessary to know themass of each back-up pad. However, if pre-weighed internal capsules andpre-weighed filters are used, it will be necessary to know the influence ofthe mass of each back-up pad on the overall mass of the entire sampl
37、ingassembly (to the nearest 0.1 mg).6.1.5 Collection nozzle, consisting of a piece of flexiblepolyvinyl chloride (PVC) tubing of length 5.5 6 0.5 cm and0.60 6 0.005 cm inside diameter, cut at a 45 angle at the inletend.6.1.6 Tubing, flexible, inside diameter 0.60 6 0.005 cm forconnecting the samplin
38、g device to the air sampling pump(maximum length 1 m).6.1.7 Air sampling pump, portable, capable of sampling at aflow rate of 2.5 6 0.5 L/min. The pump shall be calibratedwith a representative sampling assembly in line so that thevolume of air sampled can be measured to an accuracy of65 % or better.
39、6.1.8 Calibration device, for air sampling pumps; soapbubble meter or equivalent, as specified in Practice D 3195.6.1.9 Rotameter, calibrated, as specified in Practice D 3195.6.1.10 Sampling templates, minimum dimensions 10 cm by10 cm, maximum dimensions 30 cm by 30 cm; reusablemetallic or plastic;
40、or disposable plastic or cardboard.6.1.11 Gloves, powderless, latex-free, for handling of filters,back-up pads/supports, samplers, tubing, collection nozzles,and other sample collection components.6.1.12 Tape, adhesive, for immobilization of sampling tem-plates; and for delineation of sampling areas
41、 where the use oftemplates is impractical.6.1.13 Tape measure or ruler, metric, for measurement ofsampling areas when the use of templates is impractical, andfor measurement of tubing, collection nozzles, and so forth.6.1.14 Tweezers, plastic or plastic-tipped metallic, for han-dling of filters.6.1.
42、15 Sealable plastic bags, or boxes, or other airtightcontainers, or a combination of the three, for transportingcollected samples.7. Procedure7.1 Assembly of micro-vacuum sampling deviceThe fol-lowing shall be carried out in an uncontaminated area whilewearing clean gloves:7.1.1 Assemble the filter
43、in the filter holder, with the filtersupported on a back-up pad or metallic screen. To preventcontamination, the filter should be handled only with tweezers.7.1.2 If pre-weighed filters and internal capsules are used,record their masses to the nearest 0.1 mg using establishedacceptance criteria.6NOT
44、E 5If desired, pre-loaded filter holders and capsules with pre-weighed filters and internal capsules may be purchased, already as-sembled, from the manufacturer.7.1.3 Close and seal the sampling device to prevent leakageof air around the filter or into/out of the sampler. Label thesampler with a uni
45、que sample identifier.7.1.4 Attach the outlet end of the collection nozzle to theinlet end of the filter holder, and secure tightly.7.2 Calibration of sampling train for micro-vacuum sam-pling:7.2.1 Ensure that sampling pumps, if battery-powered, aresufficiently charged prior to use.7.2.2 Using a so
46、ap bubble meter or equivalent calibrationdevice (for example, a calibrated rotameter; see PracticeD 3195), set the flow rate of the air sampling pump, with asampling assembly in the line, to 2.5 6 0.1 L/min.NOTE 6While soap bubble meters are useful for applications in thelaboratory and in the field,
47、 calibrated rotameters are especially convenientfor on-site calibrations and calibration checks.7.2.3 Calibration of sampling pumps shall be checked priorto and following use.7.3 Preparation for samplingThe following shall be car-ried out while wearing clean gloves:7.3.1 Attach the sample collection
48、 device (that is, theassembly with the collection nozzle attached to filter holder) tothe calibrated sampling pump via a piece of flexible tubing.7.3.2 Using indelible ink, uniquely label the sampling cas-sette of each sample collection assembly.7.3.3 If possible, demarcate the area of the surface t
49、o besampled (for example, 10 cm by 10 cm) using a template, andsecure the outside edges of the template with tape. If it is notpractical to use a template, carefully measure the area (in cmby cm) to be sampled using a tape measure or ruler, anddelineate the sampling area with tape.NOTE 7Areas where template-assisted sampling may not be possibleinclude, for example, locations where: (a) the surface to be sampled isconfined or otherwise not easily accessible; (b) the surface to be sampledis smaller (in at least one dimension) than the template; (c) the surface
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1