1、Designation: F1613 95 (Reapproved 2016)Standard Specification forSurgical Tissue/Dressing/Pick-Up Forceps (Thumb Type)1This standard is issued under the fixed designation F1613; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers general workmanship aspectsof spring-action, tissue, dressing, or pick-up forceps (th
3、umb-type) intended for the retraction, grasping, or dissection oftissue during surgical procedures.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.2. Referenced Documents2.1 ASTM Standards:2E18 Test Methods for Rock
4、well Hardness of Metallic Ma-terialsE92 Test Methods for Vickers Hardness and Knoop Hard-ness of Metallic MaterialsE140 Hardness Conversion Tables for Metals RelationshipAmong Brinell Hardness, Vickers Hardness, RockwellHardness, Superficial Hardness, Knoop Hardness, Sclero-scope Hardness, and Leeb
5、HardnessF899 Specification for Wrought Stainless Steels for SurgicalInstrumentsF921 Terminology Relating to Hemostatic ForcepsF1026 Specification for General Workmanship and Perfor-mance Measurements of Hemostatic ForcepsF1089 Test Method for Corrosion of Surgical InstrumentsF1638 Terminology for Su
6、rgical Tissue/Dressing/Pick-UpForceps (Thumb-Type)3. Terminology3.1 Definitions:3.1.1 Definitions shall be in accordance with TerminologyF1638.3.1.2 modified working endsworking surfaces possessingsuperior hardness characteristics that are the result of eitherdepositing various materials on the base
7、 metal or securing aninsert permanently (such as by brazing) to the base metal (seeNote 3).4. Material4.1 All component parts of the instrument shall be fabri-cated from Class 4 martensitic stainless steel in accordancewith Specification F899. The modified working ends may be ofstellite, tungsten ca
8、rbide, or other suitable material.5. Requirements5.1 Heat Treatment and Hardness for Component Parts:5.1.1 The stainless steel component parts shall be heattreated under conditions recommended for the material used.5.1.2 The Rockwell hardness (HRC) of the instrument withthe working end not modified
9、shall be 4049 HRC (see TestMethods E18) after appropriate processing. Instruments inwhich the working end has been modified shall have an HRCof A77.5.2 Corrosion ResistanceInstruments shall be subjected tocorrosion tests as specified in Test Method F1089.5.3 Finish:5.3.1 SurfacesSurfaces of the inst
10、ruments shall be uni-formly finished and free of burrs, sharp edges, cracks, coarsemarks, and processing materials.5.3.2 TypeThe finish shall be one of the types specified inTerminology F921 or as specified by the purchaser.5.4 Workmanship:5.4.1 SymmetryExcluding functional differences, bothforceps
11、halves shall be symmetrical.5.4.2 TeethTeeth shall be well formed, uniform in depthand spacing, and mesh without binding, unless designedotherwise.5.4.3 Handle SerrationsHandle serrations shall be uni-form in depth and spacing.5.5 Guide Pin and Guide Pin Hole:5.5.1 The guide pin shall pass through t
12、he guide pin holewithout binding.5.5.2 The guide pin length shall not protrude past theoutside surface of the guide pin hole when the forceps tipscome in contact.1This specification is under the jurisdiction of ASTM Committee F04 onMedical and Surgical Materials and Devices and is the direct respons
13、ibility ofSubcommittee F04.33 on Medical/Surgical Instruments.Current edition approved Oct. 1, 2016. Published October 2016. Originallyapproved in 1995. Last previous edition approved in 2008 as F1613 95 (2008)1.DOI: 10.1520/F1613-95R16.2For referenced ASTM standards, visit the ASTM website, www.ast
14、m.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1NOTE 1Guid
15、e pin/guide pin holes are generally used on forceps 712in. (191 mm) or longer.6. Performance6.1 AlignmentScissoring shall be 0.015 in. (0.38 mm) orless upon closure.7. Marking and Labeling7.1 All marking and labeling shall be legible.7.2 The instruments shall bear the following: (1) the manu-facture
16、rs (or contractors) name or registered trademark; (2)the country of origin (when the instrument is not manufacturedin the United States); and (3) other markings, as required, bythe purchaser or the manufacturer (contractor).7.3 The marking shall be located on a suitable surface of theinstrument.NOTE
17、 2This specification is not intended to cover delicate tissueforceps such as those used in microsurgery or neurosurgery.NOTE 3Typical methods of modifying the working end of the forcepsis to use jaw inserts or to plasma deposit (flame plate) materials withimproved wear characteristics such as tungst
18、en carbide or stellite. For thejaw insert methods, the insert is brazed to the jaw face with a uniformdeposit of silver solder that is free of crevices at all interfaces. For theflame plating method, a uniform layer of material that is 0.004 6 0.001 in.(0.1 6 0.03 mm) thick is deposited.ASTM Interna
19、tional takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely th
20、eir own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should
21、 be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standa
22、rds, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http:/ 95 (2016)2