1、Designation: F402 05 (Reapproved 2012)An American National StandardStandard Practice forSafe Handling of Solvent Cements, Primers, and CleanersUsed for Joining Thermoplastic Pipe and Fittings1This standard is issued under the fixed designation F402; the number immediately following the designation i
2、ndicates the year of originaladoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies
3、 of the Department of Defense.1. Scope1.1 This practice covers procedures for safe handling ofsolvent cements, primers, and cleaners used in joining thermo-plastic pipe and fittings. The procedures are general ones andinclude safeguards against hazards of fire and precautions forprotection of person
4、nel from breathing of vapors and contactwith skin or eyes.1.2 The word cleaner, when used in this practice, refers tochemical cleaners.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to est
5、ablish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1600 Terminology for Abbreviated Terms Relating toPlasticsF412 Terminology Relating to Plastic Piping Systems2.2 Other Document:CFR Titl
6、e 49, Transportation, Parts 1 to 19933. Terminology3.1 DefinitionsDefinitions are in accordance with Termi-nology F412, and abbreviations are in accordance with Termi-nology D1600, unless otherwise specified.3.2 Definitions of Terms Specific to This Standard:3.2.1 cleaner, chemicalan organic solvent
7、 used to removeforeign matter from the surface of plastic pipe and fittings.3.2.2 primeran organic solvent, or blend of solvents,which enhances adhesion, applied to plastic pipe and fittingsprior to application of a solvent cement.3.2.3 solvent cementan adhesive made by dissolving aplastic resin or
8、compound in a suitable solvent or mixture ofsolvents. The solvent cement dissolves the surfaces of the pipeand fittings to form a bond between the mating surfacesprovided the proper cement is used for the particular materialsand proper techniques are followed.4. Safe Handling4.1 A number of the solv
9、ents contained in cements, primers,and cleaners are classified as airborne contaminants andflammable and combustible liquids. These products generallyare composed of solvent blends which vary with manufactur-ers. Follow precautions given herein to prevent fire and injuryto personnel. Specific safety
10、 information on a particular ce-ment, primer, or cleaner may be found on the container label orin the Material Safety Data Sheet available from the manufac-turer.4.2 Avoid prolonged breathing of solvent vapors. Whenpipe and fittings are being joined in partially enclosed areas,use a ventilating devi
11、ce in such a manner as to maintain a safelevel of vapor concentration with respect to toxicity4,5andflammability6in the breathing area. Select ventilating devicesand locate them so as not to provide a source of ignition toflammable vapor mixtures.4.3 Keep cements, primers, and cleaners away from all
12、sources of ignition, heat, sparks, and open flame.64.4 Keep containers of cements, primers, and cleanerstightly closed except when the product is being used. Thecontainer type shall be in accordance with CFR Title 49.Container labeling shall conform with the requirements of theFederal Hazardous Subs
13、tance Act and OSHA Hazard Commu-nication Act.1This practice is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.20 on Joining.Current edition approved Feb. 1, 2012. Published February 2012. Originallyapproved in 1974. Last pre
14、vious edition approved in 2005 as F402 05. DOI:10.1520/F0402-05R12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM we
15、bsite.3Available from Superintendent of Documents, U.S. Government PrintingOffice, Washington, DC 20402.4Threshold Limit Values of Airborne Contaminants, issued annually, AmericanConference of Governmental Industrial Hygienists, Cincinnati, OH.5Occupational Safety and Health Standards Federal Regist
16、er Title 29, Part 1910.6“Flammable Liquids, National Fire Codes NFICA, issued annually, “Flam-mable Liquids, National Fire Protection Association.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.5 Dispose of all rags and other mater
17、ials used for moppingup spills in an outdoor safety waste receptacle. Empty thereceptacle daily with proper consideration for its flammablehazard.4.6 Most of the solvents used in pipe cements, primers, andcleaners can be considered eye irritants and contact with theeye should be avoided as it may ca
18、use eye injury. Proper eyeprotection and the use of chemical goggles or face shields isadvisable where the possibility of splashing exists in handlingthese products. In case of eye contact, flush with plenty ofwater for 15 min and call a physician immediately.4.7 Avoid contact with the skin. Wear pr
19、oper gloves imper-vious to and unaffected by the solvents when contact with theskin is likely. Application of the primers, cleaners, or solventcements with rags and bare hands is not recommended.Brushes, daubers, and other suitable applicators can be usedeffectively for applying these products, thus
20、 avoiding skincontact. Dispose of used applicators in the same manner as therags (see 4.5). In the event of contact, remove contaminatedclothing immediately and wash skin with soap and water. Washcontaminated clothing before wearing them again.5. Keywords5.1 adhesive; cleaners; primer; safe handling
21、; solvent ce-ment; vaporsASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infring
22、ement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard
23、or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views
24、known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).F402 05 (2012)2