1、Designation: F2462 05 (Reapproved 2015)Standard Practice forOperation and Maintenance of Sewers with Optical FiberSystems1This standard is issued under the fixed designation F2462; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice applies to the operation and maintenanceof sewers with a subsequent installation of optical fi
3、ber cable inaccordance with Practice F2303.1.2 This practice applies to gravity flow storm sewers,sanitary sewers, and combined sewers.1.3 This practice does not apply to force mains, siphons, orother pressurized sewers.1.4 This standard does not purport to address all of thesafety concerns, if any,
4、 associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F2303 Practice for Selection of Gravity Sewers Suita
5、ble forInstallation of Optical Fiber Cable and Conduits2.2 ANSI Standard:3ANSI Z117.1-2003 Safety Requirements for ConfinedSpaces2.3 IEC Standards:4IEC 60825-1 Ed. 1.2, en 2001, Safety of Laser ProductsPart 1: Equipment Classification, Requirements and Us-ers GuideIEC 60050-731 Electrotechnical Voca
6、bulary: Optical FiberCommunications2.4 Federal Standard:5OSHA Regulation 29 CFR Part 1910.146, Permit-RequiredConfined Spaces3. Terminology3.1 Definitions:3.1.1 conduit, ntubing used to house optical fiber cablethat is connected to, but separate from, a sewer pipeline.3.1.2 O4.1.2 Emergency response
7、 procedures, including sewagespill control, emergency sewer pipeline repair, and communi-cation procedures;4.1.3 Routine sewer O sewer pipeline repairs; periodic sewerinspection; sewer pipeline cleaning;4.1.4 Routine optical fiber system O4.1.5 Cable and conduit marking; and4.1.6 Worker qualificatio
8、n.5. Significance and Use5.1 This is intended to outline O and6.3.2.2 Where assistance by the optical fiber cable ownermay be necessary.6.4 Routine Operating Procedures:6.4.1 Notification:6.4.1.1 The sewer operator and fiber cable system ownershould notify the other entity as far in advance as possi
9、ble forplanned, routine operations.6.4.1.2 Improper cable repair or maintenance proceduresmay damage the sewer or optical fiber system, creating anunsafe situation. Because of this risk, the fiber cable systemowner must notify the sewer pipeline operator as to the natureof the intended repair or mai
10、ntenance and verify whether seweroperator supervision or oversight is required during the repairor maintenance.6.4.2 Extended Duration Access (4 hours+) to Sewer Vaultsby Optical Fiber System OwnerWhen accessing a sewervault or sewer manhole, the optical fiber cable owner mustprovide the sewer pipel
11、ine operator with at least 48 hours priornotice. If re-cabling, replacing the conduit or other extendeddurations repairs are contemplated, the optical fiber systemowner must provide with that notice, written repair procedures,the duration and hours that the vault or manhole is beingaccessed and othe
12、r requirements which may be locally required(traffic control plans, odor control, and so forth).6.4.3 Sewer Service ConnectionsThe optical fiber cableowner must provide the sewer pipeline operator with preferredmethods for adding sewer service connections. In the absenceof those preferences, the sew
13、er pipeline operator may use anycustomary method.6.4.4 Sewer Pipeline Maintenance and RehabilitationTheoptical fiber cable owner must provide the sewer pipelineoperator with preferred methods for chemicals used for odor,grease or root control, mechanical cleaning methods forblockages or roots, hydra
14、ulic cleaning or flushing methods,pipeline and manhole rehabilitation techniques, and so forth. InF2462 05 (2015)2the absence of those preferences, the sewer pipeline operatormay use any customary method.6.5 Mutual Advice:6.5.1 During any inspection, the sewer pipeline operator oroptical fiber cable
15、 owner should advise the other of anydamage observed in the others facilities. Items that requireattention by the sewer pipeline operator include infiltration,flooded manholes, root intrusions, and so forth. Items thatrequire attention of the optical fiber cable owner include vaultlid damage, crimps
16、, open splice cases, standing water, pinches,nicks, or cuts in cable jacketing.6.6 Marking and Identification:6.6.1 VaultsIn sewer reaches containing optical fibercables, each sewer access (vault) must be clearly and conspicu-ously identified as containing optical fiber cables. A contactnumber must
17、be provided where the optical fiber cable owneror sewer pipeline operator may access further instructions onhow to safely proceed.6.6.2 ConduitConduit containing optical fiber cable (lo-cated outside of the pipeline) must be clearly and uniquelymarked to minimize the chances that the pipeline operat
18、or willinadvertently damage the cable by cutting or pinching opera-tions.7. O7.1.2 Safety procedures and personal protective equipmentfor accessing a sewer vault;7.1.3 The designated emergency notification contact(s) forthe sewer operator and optical fiber cable owner;7.1.4 The designated routine no
19、tification contact(s) for thesewer operator and optical fiber cable owner;7.1.5 Activities that are routine sewer O7.1.6 Activities that are routine optical fiber cable O7.1.7 Target times for advance notifications;7.1.8 Any desire for the sewer pipeline operator or opticalfiber cable owner to obser
20、ve the others field operations;7.1.9 Preferred methods for adding new house connectionsto the sewer;7.1.10 Preferred methods for sewer cleaning and mainte-nance;7.1.11 Preferred methods for sewer pipeline and manholerehabilitation;7.1.12 Types of sealants, solvents, coatings, and otherclasses of mat
21、erials that may be installed inside sewer pipelinesystems;7.1.13 Any local or regional permit and inspection require-ments;7.1.14 Any subsequent revisions that are agreed upon byboth parties; and7.1.15 Other items which enhances the O fiber installation method; operations andmaintenance; optical fib
22、er; sewer gas; sewers; telecommunica-tionsASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and t
23、he riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision
24、of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shoul
25、dmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtain
26、ed by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http:/ 05 (2015)3