1、Designation: F2495 05 (Reapproved 2011)Standard Test Method forDetermining Energy Consumption of MFDs with CopyingCapability and Similar Office Imaging Equipment1This standard is issued under the fixed designation F2495; the number immediately following the designation indicates the year oforiginal
2、adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This procedure provides a test method by which multi-functional devi
3、ces (MFDs) with electro-photographic copyingcapability and similar office imaging equipment may be ratedfor energy consumption.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish a
4、ppro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 International Standards:ISO/IEC 11159 Minimum Information to be Included inSpecification SheetsCopying Machines2ISO 554 Standard Atmospheres for Conditioning and
5、/orTesting Specifications22.2 Federal Energy Management Program (FEMP) web-site:http:/www.eere.energy.gov/femp/technologies/eep_standby_power.cfm#sleep3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 optional devicesany device added to improve thefunctionality of the base unit.
6、 They include an automaticdocument feeder (ADF), sorter, finisher and expansionmemory.3.1.2 copier speed, first copy (X)one of the convenientlevels for which the machines speed is measured. This iscalculated based on the amount of time, a1(sec), counted in anormal operating mode from the beginning o
7、f pressing theprint button of the machine to the end of ejecting the first copy,X = 60/ a1(ipm). For MFDs with ADF, the amount of time, a1shall be used, counted from pressing the print button afterplacing an original or originals on the ADF to the end ofejecting the first copy.3.1.3 copier speed, mu
8、lti copy (Y)one of the convenientlevels for which the machines speed is measured. This iscalculated based on the amount of time, a2(sec), counted in anormal operating mode from the end of ejecting the first copyafter pressing the print button of the machine to the end ofejecting the remaining copies
9、 (b), Y =(b) 60/a2(ipm).Normally, the value declared in the machines specificationsshall be used.3.1.4 ready modethe condition that exists when the ma-chine is ready for copying, but has not yet started copying, andhas not entered an energy-saver mode, either.3.1.5 copying cyclethe condition that ex
10、ists from thebeginning to the end of a nominal job cycle (1 h) to produce acopy or copies. According to the machines multi copy speed(Y) declared in the specifications, the following are listed in JobTables: nominal monthly volumes assumed, nominal volumesper day and combinations of the number of jo
11、bs as18 day (1 h)nominal jobs, the number of originals per job and the numberof copies per original.3.1.6 copying energythe amount of energy needed inexcess of ready mode energy during a copying cycle.3.1.7 copying timethe amount of time that the nominaljobs are run when testing copying energy durin
12、g a copyingcycle.3.1.8 wake-up energythe amount of energy needed inexcess of ready mode energy when the machine recovers froma standard work days first sleep stand-by mode.3.1.9 energy-saver modethe condition that exists when themachine is not making copies and is consuming less powerthan when the m
13、achine is in a ready mode. The machine goesinto this mode after it completes a job such as copying and nojob is scheduled in a specified time period. Since the Interna-tional Energy Star Program has been used widely in the world,this has caused MFDs to have this mode. This standardparticularly desig
14、nates this condition as an energy-saver modein operating hours (9 h) of a standard work day.3.1.9.1 DiscussionThe International Energy Star Programstipulates that the machine shall be set to enter an energy-saver1This test method is under the jurisdiction ofASTM Committee F05 on BusinessImaging Prod
15、ucts and is the direct responsibility of Subcommittee F05.04 onElectrostatic Imaging Products.Current edition approved Oct. 1, 2011. Published September 2012. Originallyapproved in 2005. Last previous edition approved in 2005 as F249505. DOI:10.1520/F2495-05R11.2Available from American National Stan
16、dards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1mode 15 minutes or less after the end of a job such as copying.However, on the assumption that the machine is used in
17、 anetworked environment, considering the fact that shorter pass-ing time has been set than before because a recovery triggereasily takes place and recovery time tends to be reduced, thistest method stipulates that the machine shall stay in a readymode for 10 minutes after the end of a job such as co
18、pying upuntil it starts passing to the energy-saver mode. The recoverytime from the energy-saver mode to the ready mode shall be setto 30 seconds or less. Energy-saver mode design to fulfill thisrecovery time is left to the manufacturers discretion. This testmethod provides energy calculations on th
19、e assumption that thepassing time is 10 minutes. If setting of the time shorter than 10minutes is accepted by users in the future, the procedure of thistest method will be reviewed.3.1.10 sleep stand-by modethe condition with less energyconsumption than the energy-saver mode in 3.1.9. The machineent
20、ers the energy-saver mode 10 minutes after the end of a jobsuch as copying and then enters a sleep stand-by mode, if noadditional job is scheduled in a specified time period.Normally, this sleep stand-by mode stays for a whole day ofSaturday and Sunday weekends other than standard work days.As for s
21、tandard work days, the machine stays in this mode atnight as a night stand-by condition. It is calculated by subtract-ing the 9 hours of operation from the 24 hours in a day.3.1.11 energy-saver recovery timethe amount of time thatthe machine takes to enter the ready mode after it comes out ofthe ene
22、rgy-saver mode in the 9-h operating condition of astandard work day.3.1.12 energy-saver mode timethe amount of time that themachine is in an energy-saver mode in the 9-hour operatingcondition of a standard work day.3.1.13 lunch breakone hour assigned to a lunch break thatexists between 4-h morning a
23、nd 4-h afternoon in the 9-hoperating condition of a standard work day. The machine staysin an energy-saver mode during this time period.3.1.14 jobmaking a copy or copies from one or moreoriginals without interruption or delay between originals. Sincetarget machines are MFDs with copying capability,
24、copyingshall be used for rating to represent all the jobs.3.1.15 machine energythe energy obtained by subtractingenergy consumed for copying (3.1.6) from total energy con-sumed in a standard month where the machine is plugged-in 24h/day including the 9-h operating condition.3.1.16 nominal copies per
25、 daythe number of nominalcopies produced on a single machine during a nominal standardwork day.3.1.17 nominal monthly volumemonthly volume nomi-nally determined according to the copying speed band cat-egory.3.1.18 plug-in modethe condition that exists when themachine is connected to an appropriate e
26、lectrical source and isnot turned on. (This mode is also referred to as hard-off mode,manual-off mode or plug-in-off mode.) This corresponds to theone specified on the FEMP website.3.1.19 recovery energythe amount of energy needed inexcess of energy-saver mode energy to pass from the energy-saver mo
27、de to the ready mode.3.1.20 standard copya sheet imaged on one side thatmeasures 210 by 297 mm (A4) or 812 by 11 in. (letter size).3.1.21 standard monththirty 24-h days.3.1.22 standard work daya day having an operating con-dition (9-h) including a 1-h lunch break. A standard month (30days) has 22 da
28、ys.3.1.23 wake-up modethe condition that exists when themachine comes out of a sleep stand-by mode for the first timein the morning of a day of 22 standard work days, but has notyet entered into a ready mode.3.1.24 warm-up modethe condition that exists when themachine is turned on from a plug-in mod
29、e and prior to reachingthe ready mode.3.1.25 operating conditionnine hours starting from thedays first wake-up mode on condition that recovery from thesleep stand-by mode occurs each of 22 standard work days.This consists of1hofalunch break and 8 hours of daystypical job cycles.4. Summary of Test Me
30、thod4.1 The standard energy consumption rating is determined(using a watt-hour meter) for a MFD while the machine is in asimulated customer installation performing copying represent-ing a typical days jobs for one eighth (1 h) of the day. Thetypical days jobs (the number of jobs, originals, and copi
31、es peroriginal) are based on the standard monthly volume assumedaccording to its copy speed. In this test method, there is nodifference in assumed nominal monthly volumes betweenmonochrome MFDs and color ones. In other words, since acolor MFD naturally has two copying speeds (speeds in colorand mono
32、chrome modes), this test method gives the colorMFD the nominal standard monthly volume of a monochromeMFD of which speed equals the color MFDs maximum speed(normally, in monochrome mode).4.1.1 However, since the job conditions depend on whetheror not a MFD has a color mode, separate job tables have
33、beenprovided for color MFDs and monochrome MFDs.4.1.2 Moreover, note should be taken that two types of jobtables have been provided for color MFDs according to thestructure (1 drum: serial type, and 4 drum: parallel type).(Refer to the Job Tables in Annex A1.)4.2 The energy consumption may be calcul
34、ated based on thefollowing assumptions, that the MFD will typically:4.2.1 Be connected to a live power line for thirty 24 h days(720 h) per month.4.2.2 Be in the operating condition each of 22 work days permonth and be in an operating condition for an average of 9 heach of the 22 days.4.2.3 As a res
35、ult of items 4.2.2 and 3.1.23, come out of thesleep stand-by mode to enter the wake-up mode each of 22work days, since the MFD normally has the sleep stand-bymode where the machine automatically enters after a period oftime of non-use or no job scheduled.F2495 05 (2011)24.2.4 As a result of Discussi
36、on in item 3.1.9.1, not enter theenergy-saver mode during a copy cycle, if the number ofnominal jobs per hour (18 of a days copying cycle) is 6 ormore in the job table and this leads to job interval of 10 minutesor less; and as a result of 3.1.13, be in the energy-saver modeduring the 1-h lunch brea
37、k each of 22 work days. To facilitatethe tests, the upper limit of the number of jobs shall be 6.4.2.4.1 DiscussionIn actual use, the higher the monthlycopying volume is, the larger the number of jobs is. Besides, itis less likely for the machine to go into the energy-saver mode.Considering these, t
38、he numbers of jobs are provided accordingto the nominal monthly volume in the job table and themachine behavior as follows:(1) The nominal monthly volume of 35 000 or less leads tothe number of jobs of 5 or less per hour (18 day) and themachine enters the energy-saver mode during the copyingcycle; a
39、nd(2) The nominal monthly volume of 42 000 or more leadsto the number of jobs of 6 per hour (18 day) and the machinedoes not enter the energy-saver mode during the copying cycle.4.2.5 Perform a typical days copying jobs each of the 22work days each month.4.3 The rating of energy consumption per hour
40、 in a typicalmonth (kWh/h) is determined using calculations based on thetest data.5. Significance and Use5.1 This test method provides a procedure for measuring theenergy consumption of the product and optional devices invarious operating modes. It is intended to permit rating theenergy requirements
41、 of products by a method that will permitaccurate energy efficiency comparisons of each product withall other similar products.6. Apparatus and Supplies6.1 Watt-Hour Meter, shall be calibrated properly and havea crest factor of 3 or more.6.2 Timer, a timing device accurate to 1 s.6.3 Test Target, 21
42、0 by 297 mm (A4) or 812 by 11 in. (letter)with 4 to 8 % coverage.6.4 Paper, 210 by 297 mm (A4), 60 to 80 g/m2,812 by 11in. (letter), 20-lb bond or where not applicable, use machinemanufacturers recommended paper size and weight, depend-ing on the machine sales area.7. Sampling (Equipment Under Test:
43、 EUT)7.1 The energy rating should be that for a device represen-tative of the commercially available equipment. Any modifi-cation of the product or additional configurations that signifi-cantly alter energy consumption will require re-ratings oradditional ratings.7.2 Those MFDs configured with autom
44、atic duplex optionshould be rated twice for each job, once at 100 % single-sidedcopy and once at 100 % of two-sided copies (making two-sidedcopies from single-sided originals, each side counted as onecopy).7.3 The MFD(s) to be evaluated should be set to within themanufacturers operating specificatio
45、ns.8. Preparation of Apparatus8.1 Test Conditions:8.1.1 The room ambient shall be within a range of 23 63C; 50 6 10 % relative humidity in compliance with ISO 554.8.1.2 The working voltage shall be machine-rated voltage 62 %. Stabilized power supply shall be used.8.1.3 The machine shall be at least
46、500 mm from any wallor obstacle.8.1.4 All supplies used shall be those specified by the MFDmanufacturer and preconditioned for a minimum of 12 h in theroom ambient environment (see 8.1.1) prior to evaluating theMFD energy rating.8.1.5 The power supply voltage shall be supplied as a truesine wave wit
47、h no more than 3 % harmonic distortion.8.1.6 The power frequency must be rated frequency 6 0.1Hz.8.1.7 The manufacturer will define the configuration (in-cluding optional devices) of the machine to be tested, thenominal monthly volume at which it will be rated (see JobTables), and both the first cop
48、y speed and multi copy speed.8.1.8 The test should be discontinued if an unusually highnumber of machine problems occur. Excess machine stoppagesmay distort the overall energy rating. A reasonable number ofpaper jams that can be readily cleared by the operator shouldnot be considered reason to disco
49、ntinue the test.9. Procedure9.1 Steps 9.1.1-9.1.10 of this procedure should be com-pleted once for each test machine. The data from 9.1.5 willonly apply to one configuration and, if the machine hasconfiguration variations, the rating must be repeated for eachconfiguration for which the machine is being rated. Prior to thestart of this test, the machine should be plugged in to a livepower line but turned off and stabilized at specified roomambient conditions (indoors) for at least 12 h. An appropriatewatt-hour meter should be in line