1、Designation: F2643 09F2643 15 An American National StandardStandard Specification forPowered Pot, Pan and Utensil Washing Sinks1This standard is issued under the fixed designation F2643; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisi
2、on, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers commercial powered pot, pan and utensil washing sinks.1.2 The values stated
3、in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use
4、. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A29/A29M Specification for General Requirements for Steel Bars, Carbon and Allo
5、y, Hot-WroughtA120 Specification for Pipe, Steel, Black and Hot-Dipped Zinc-Coated (Galvanized) Welded and Seamless for Ordinary Uses;Replaced by A 53 (Withdrawn 1987)3A167A240/A240M Specification for StainlessChromium and Heat-Resisting Chromium-Nickel Stainless Steel Plate, Sheet, andStrip for Pre
6、ssure Vessels and for General Applications (Withdrawn 2014)A276 Specification for Stainless Steel Bars and ShapesA436 Specification for Austenitic Gray Iron CastingsA554 Specification for Welded Stainless Steel Mechanical TubingA582/A582M Specification for Free-Machining Stainless Steel BarsB43 Spec
7、ification for Seamless Red Brass Pipe, Standard SizesB75 Specification for Seamless Copper TubeB127 Specification for Nickel-Copper Alloy (UNS N04400) Plate, Sheet, and StripF760 Specification for Food Service Equipment ManualsF2379 Test Method for Energy Performance of Powered Open Warewashing Sink
8、s2.2 Federal Regulations:4OSHA Title 29 Chapter XVII, Part 19102.3 American National Standards:5ANSI S1.4 Specification for Sound Level MetersANSI S1.13 Methods for the Measurement of Sound Pressure Levels2.4 National Electrical Manufacturers Association Standards:6NEMA ICS Industrial Controls and S
9、ystemsNEMA MG-1 Motors and Generators2.5 National Fire Protection Association Standards:7NFPA No. 70 National Electrical Code1 This specification is under the jurisdiction of ASTM Committee F26 on Food Service Equipment and is the direct responsibility of Subcommittee F26.01 on Cleaningand Sanitatio
10、n Equipment.Current edition approved Oct. 1, 2009Aug. 1, 2015. Published October 2009September 2015. Originally approved in 2007. Last previous edition approved in 20072009as F2643 07.F2643 09. DOI: 10.1520/F2643-09.10.1520/F2643-15.2 For referencedASTM standards, visit theASTM website, www.astm.org
11、, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.4 Available from U.S. Government Printing
12、Office Superintendent of Documents, 732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.access.gpo.gov.5 Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http:/www.ansi.org.6 Available from National Electrical Manufacture
13、rs Association (NEMA), 1300 N. 17th St., Suite 1752, Rosslyn, VA 22209, http:/www.nema.org.7 Available from National Fire Protection Association (NFPA), 1 Batterymarch Park, Quincy, MA 02169-7471, http:/www.nfpa.org.This document is not an ASTM standard and is intended only to provide the user of an
14、 ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as publis
15、hed by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12.6 NSF International Standards:8NSF/ANSI 2 Food EquipmentNSF/ANSI 51 Plastic Materials and Components Used in Food EquipmentNSF Lis
16、tings Food Equipment2.7 Underwriters Laboratories Standards:9UL 921 Commercial Electric Dishwashers2.8 American Society of Sanitary Engineering ASSE International Standards:10ASSE 1001 Pipe Applied Atmospheric Vacuum Breakers3. Terminology3.1 Definitions:3.2 powered pot, pan and utensil washing sink
17、, nan all-purpose, stainless steel water basin with electrically powered waterpump(s) and multiple high flow water nozzles designed for cleaning pots, pans and utensils.3.2.1 DiscussionThe main washing basin holds 50 to 100 gal (189 to 379 L) of heated water. The unit may or may not feature a scrapp
18、er sink (withor without a disposer), rinse tank, sanitizing tank, or a drain table, or a combination thereof. The machines shall consist of thefollowing principal parts: legs, wash basin, rinse basin, sanitizing basin, clean and soiled end drain boards, spray nozzles, pump,motor, controls, and pipin
19、g. May or may not be provided with an electric heater, faucet, pre-rinse spray hose and other accessories.4. Classification4.1 GeneralPowered pot, pan and utensil washing sink shall be of the following types, styles, classes, size, and capacitygroup, as specified:4.2 Types:4.2.1 Type I (Right-to-Lef
20、t)This machine is designed with the utensil flow from the right to the left as you are facing themachine.4.2.2 Type II (Left-to-Right)This machine is designed with the utensil flow from the left to the right as you are facing themachine.4.3 Styles and Classes:4.3.1 Style 1 (electrically heated wash
21、tank).4.3.1.1 Class A (single temperature set point)4.3.1.2 Class B (dual temperature set points)4.3.2 Style 2 (no heat).4.4 Size and Capacity: Sizes are as follows:4.4.1 Drainboards, soiled and clean ends(typically 12, 18, 20, 24, 30, 36, 42, 48, 54, or 60 in. (30, 46, 51, 61, 76, 91, 107,122, 137,
22、 or 152 cm)4.4.2 Scrapper section(typically 20 or 36 in. (51 or 91 cm). May or may not be provided with a disposer.4.4.3 Wash Sink(typically 30, 32, 36, 42, 48, 54, or 60 in. (76, 81, 91, 107, 122, 137, or 152 cm).4.4.4 Rinse Sink(typically 15, 18, 20, 24, 30, or 36 in. (38, 46, 51, 61, 76, or 91 cm
23、).4.4.5 Sanitizer Sink(typically 18-12, 20, 24, 30, or 36 in. (47, 51, 61, 76, or 91 cm).4.5 All powered pot, pan and utensil washing sinks of the same classification, model, or material list designation furnished withsimilar options under a specific purchase order shall be identical to the extent n
24、ecessary to ensure interchangeability of componentparts, assemblies, accessories, and spare parts.5. Ordering Information5.1 Purchasers should select the preferred options permitted in this specification and include the following information in theprocurement document:5.1.1 Title, number, and date o
25、f this standard,5.1.2 Type, and size machine required, including width of each sink section and drainboards (see 4.1),5.1.3 Noise level requirements, if other than specified (see 11.2),5.1.4 When a service-supply valve is required (see 7.4),5.1.5 When overflows are required (see 7.7),8 Available fro
26、m NSF International, P.O. Box 130140, 789 N. Dixboro Rd., Ann Arbor, MI 48113-0140, http:/www.nsf.org.9 Available from Underwriters Laboratories (UL), UL LLC, 333 Pfingsten Rd., Northbrook, IL 60062-2096, http:/.10 Available fromASSE International, 901 Canterbury, SuiteA, Westlake, OH 44145,18927 Hi
27、ckory Creek Drive, Suite 220, Mokena, IL 60448, infoasse-plumbing.org.F2643 1525.1.6 Electrical power supply characteristics (current, voltage, phase, frequency) (see Section 8),5.1.7 Accessory equipment, spare and maintenance parts required, as suggested by manufacturer,5.1.8 Treatment and painting
28、 if other than specified (see Section 10),5.1.9 When energy consumption profiles, water consumption profiles, or productivity profiles are desired (see 12.3), and5.1.10 Manufacturers certification, when required (see Section 13).6. Materials and Design6.1 All materials shall be specified as follows:
29、6.1.1 Materials used shall be free from defects that would adversely affect the performance or maintainability of individualcomponents of the overall assembly. The powered pot, pan and utensil washing sink shall meet the material, design, andconstruction requirements of NSF/ANSI 2.6.1.2 Corrosion-Re
30、sistant SteelCorrosion-resistant steel shall conform to the requirements of any 300 series stainless steelspecified in 2.1.6.1.3 Corrosion-Resisting MaterialCorrosion-resisting material is other than corrosion resistant steel that is equivalent in thepowered pot, pan and utensil washing sink applica
31、tion.6.1.4 Nickel-Copper AlloyNickel-copper alloys shall conform to the requirements of Specification B127.6.1.5 PlasticsAll plastic materials and components used in the powered pot, pan and utensil washing sink in contact withwater shall conform to NSF/ANSI 2 or NSF/ANSI 51.7. Construction Requirem
32、ents7.1 The powered pot, pan and utensil washing sink shall be complete so that when connected to the electric power supply, watersupply, drainage, the unit can be used for its intended function. Powered pot, pan and utensil washing sinks shall be rigid, quietin operation as specified by user, free
33、from objectionable vibration, and so constructed as to prevent objectionable splashing ofwater or overflow of water to the outside of the machine. Parts requiring adjustment shall be readily accessible. Parts requiringservice shall be accessible. The machine shall aid in the process of manually wash
34、ing dishes by pumping a water and detergentsolution across dishes in the wash sink basin. Provisions shall be made to fill the wash sink basin either directly from the hot orcold faucet on the sink or automatically through a solenoid, or both. The pump “wash” cycle shall be automatically or manually
35、controlled. A method shall be provided to indicate that the heating element may be energized.7.2 Piping, Tubing, Fittings, and Valves (Installation)Connections shall be readily accessible to facilitate installation andmaintenance. Piping, tubing, and valves shall be located, whenever possible, on th
36、e exterior of the machine. See SpecificationsA29/A29M, A120, A167A240/A240M, A276, A554, B43, and B75.7.3 Piping and FittingsWater piping and fittings shall be of corrosion-resisting material. Fresh water supply to the sink shallbe discharged not lower than 2 in. (50.8 mm) above the maximum flood le
37、vel rim, or an effective air gap or vacuum breaker shallbe installed to prevent backflow. Backflow protection shall be in accordance with ASSE 1001. The drain and other plumbingconnections shall be standard pipe or tubing connections. Drainage piping shall be corrosion-resisting material, or suitabl
38、eheat-resisting plastic material. Drains may be joined into a single trunk line requiring only one connection or arranged to permitindividual connections to the waste line.7.4 ValvesWhen specified, a separately packed service supply valve shall be provided for closing the supply of water to thepower
39、ed pot, pan and utensil washing sink. The drain valve shall be permanently marked to show “open” and “closed” positionsand shall be lever-operated or wheel-operated, ruggedly designed for foot or hand operation except when drain valve closure isautomatic. Fresh water solenoid valves, when provided,
40、shall be reliable and fully automatic and suitable for 140F (60C) water.The manually operated faucet valves, when used, shall be identified as “hot” and “cold.”7.5 Spray AssembliesAll wash nozzles and manifolds shall be of corrosion-resisting materials (see Specification A582/A582M).7.6 TankThe tank
41、 shall be constructed of not less than 0.055 in. (1.39 mm), corrosion-resistant steel, or other corrosion-resisting material.7.7 OverflowWhen specified, the powered pot, pan and utensil washing sink shall have a readily accessible overflow drain ineach basin of the sink. The overflow unit, or cover,
42、 when provided, shall be removable for cleaning.7.8 FrameFrame members shall be constructed of not less than 0.044 in. (1.11 mm) corrosion-resistant steel, or othercorrosion resisting material, and shall be rigid and stiffened as necessary.7.9 Legs (Feet)The machine shall be rigidly constructed and
43、have four or more legs (feet) made of corrosion-resistant steel,or other corrosion-resisting material. Legs shall be provided with adjustable feet, so that the height of the table may be varied from33-12 to 34-34 in. (851 to 882 mm) above the floor.7.10 Pump and Motor Assemblies:F2643 1537.10.1 Asse
44、mbliesThe pump motor shall be mounted on the tank or on a rigid steel base. Rotary seals shall be provided forpump shafts and shall be removable for servicing.7.10.2 Pump (see Specification A436)Pump casings shall be corrosion-resisting material and shall have a removable cover orinspection plate, o
45、r be of such a design as to permit ease of accessibility for inspection and removal of foreign items from theimpeller and interior. The pump shall either be self-draining or equipped with means for draining. The shaft shall be ofcorrosion-resistant steel, properly aligned and supported. The impeller
46、 shall be corrosion-resisting material and shall be in dynamicbalance. The pump shall have at least two ball or roller bearings, except that when the pump and motor are mounted on the sameshaft, at least two ball or roller bearings shall be provided for the motor and pump. The pump suction intake sh
47、all be provided witha corrosion-resistant strainer or shroud.7.11 Heating:7.11.1 Style 1Style 1 machines shall be equipped with electric heater elements and sheaths of 300 series corrosion-resistantsteel or other corrosion resisting material. They shall be provided with temperature regulators for ma
48、intaining minimum 110F(43.3C) water temperature in the tank. Low water protection shall be provided.7.11.2 Style 2Style 2 machines are not provided with a source of heat.8. Electrical Equipment Requirements8.1 The electrical equipment shall meet the requirements of UL 921. The powered pot, pan and u
49、tensil washing sink shalloperate on the power characteristics (current, voltage, phase, frequency) specified (see NFPA No. 70).8.2 Motors (see NEMA ICS)Motors shall comply with applicable requirements of UL 921.8.3 Controls (see NEMA MG-1)All control equipment shall conform to UL 921 and be capable of operation in an ambientroom temperature of 115 6 9F (46 6 5C).8.4 Wiring and Circuit Safety DevicesAll wiring and circuit safety devices shall be in conformance with UL 921. All wiringbetween the powered pot, pan and ut