1、 AMERICAN NATIONAL STANDARD FOR TELECOMMUNICATIONS ATIS-0600015.2013 ENERGY EFFICIENCY FOR TELECOMMUNICATION EQUIPMENT: METHODOLOGY FOR MEASUREMENT AND REPORTING GENERAL REQUIREMENTS As a leading technology and solutions development organization, ATIS brings together the top global ICT companies to
2、advance the industrys most-pressing business priorities. Through ATIS committees and forums, nearly 200 companies address cloud services, device solutions, emergency services, M2M communications, cyber security, ehealth, network evolution, quality of service, billing support, operations, and more. T
3、hese priorities follow a fast-track development lifecycle from design and innovation through solutions that include standards, specifications, requirements, business use cases, software toolkits, and interoperability testing. ATIS is accredited by the American National Standards Institute (ANSI). AT
4、IS is the North American Organizational Partner for the 3rd Generation Partnership Project (3GPP), a founding Partner of oneM2M, a member and major U.S. contributor to the International Telecommunication Union (ITU) Radio and Telecommunications sectors, and a member of the Inter-American Telecommuni
5、cation Commission (CITEL). For more information, visit . AMERICAN NATIONAL STANDARD Approval of an American National Standard requires review by ANSI that the requirements for due process, consensus, and other criteria for approval have been met by the standards developer. Consensus is established w
6、hen, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by directly and materially affected interests. Substantial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considere
7、d, and that a concerted effort be made towards their resolution. The use of American National Standards is completely voluntary; their existence does not in any respect preclude anyone, whether he has approved the standards or not, from manufacturing, marketing, purchasing, or using products, proces
8、ses, or procedures not conforming to the standards. The American National Standards Institute does not develop standards and will in no circumstances give an interpretation of any American National Standard. Moreover, no person shall have the right or authority to issue an interpretation of an Ameri
9、can National Standard in the name of the American National Standards Institute. Requests for interpretations should be addressed to the secretariat or sponsor whose name appears on the title page of this standard. CAUTION NOTICE: This American National Standard may be revised or withdrawn at any tim
10、e. The procedures of the American National Standards Institute require that action be taken periodically to reaffirm, revise, or withdraw this standard. Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards In
11、stitute. Notice of Disclaimer Technical Specification Group Services and System Aspects; General Universal Mobile Telecommunications System (UMTS) architecture.43 Definitions, Acronyms, therefore, the Alternating Current (AC) noise on the input power port(s) is not considered significant. All equipm
12、ent used for taking physical measurements shall be in a current state of calibration traceable to NIST requirements or counterpart national metrology institute in other countries. 5.2 Environmental Consideration 5.2.1 Temperature The equipment shall be evaluated at temperature of 25C 3C (77 5F). 5.2
13、.2 Humidity The equipment shall be evaluated at a relative humidity of 30% to 75%. 5.2.3 Barometric Pressure The equipment shall be evaluated at a barometric pressure between 1060 and 812 mbar. 5.2.4 Voltage 5.2.4.1 DC Powered Equipment The equipment shall be evaluated at a DC voltage of 53V 2V. (Th
14、is level is consistent with the voltage defined in ATIS-0600315.2007 for a -48 Vdcpowering system.) Unless otherwise specified in a supplemental standard to this General Requirement Standard, equipment using nominal DC voltages other than -48Vdc shall be evaluated at 4% of the specified float voltag
15、e. Where applicable, the typical steady state voltage as defined in ATIS-0600315.2007 shall be used. 5.2.4.2 AC Powered Equipment The equipment shall be evaluated with a source providing the following conditions: Total Harmonic Distortion ATIS-0600015.2013 11 Environmental Test Conditions Criteria S
16、pecified Conditions Test Conditions Test Duration Minimum 5 minutes 10 minutes Ambient Temperature: 25 3C (77 5F) 23.2C Relative Humidity: 30% - 75% 50% Pressure: 1060 to 812 mbar 949 mbar Feed Voltage: -53 2 VDC -53.0 VDC Supply Power Ratio Minimum 1.5 times rated Power. (1500 Watts for system unde
17、r test) 3000 Watts Energy Analyzer Hardware Vendor: Power Analyzer Model: Super Analyzer 1 Serial Number: 9099909 Calibration Institute Cal Labs Accredited by: NIST Calibration Label: 07-0001Q Calibration Date: December 27, 2007 Power Feed Sizing Minimum: 1A At minimum supported system configuration. Maximum: 25A At maximum supported system configuration. Total Power Feeds: 4 Feed Redundancy: 2N (2+2) Contact Information Regarding This Report Name: Jenny Doe Phone: 555-555-5555 E-mail: URL: Other notes: Matrix for Modular System:
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1