1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationConnectors for electronic equipment Product requirementsPart 2-110: Circular connectors Detail specification for circular connectors M 12 x 1 with screw-locking, for high speed E
2、thernet and high speed data communication with frequencies up to 500 MHz and 10 gigabits/sDD IEC/PAS 61076-2-110:2010National forewordThis Draft for Development is the UK implementation of IEC/PAS 61076-2-110:2010.The UK participation in its preparation was entrusted to Technical CommitteeEPL/48, El
3、ectromechanical components and mechanical structures for electronic equipment.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct
4、 application. BSI 2010ISBN 978 0 580 70022 4ICS 31.220.10Compliance with a British Standard cannot confer immunity fromlegal obligations.This Draft for Development was published under the authority of theStandards Policy and Strategy Committee on 30 April 2010.Amendments issued since publicationAmd.
5、 No. Date Text affectedBRITISH STANDARDDD IEC/PAS 61076-2-110:2010IEC/PAS 61076-2-110Edition 1.0 2010-03PUBLICLY AVAILABLE SPECIFICATIONPRE-STANDARD Connectors for electronic equipment Product requirements Part 2-110: Circular connectors Detail specification for circular connectors M 12 1 with screw
6、-locking, for high speed Ethernet and high speed data communication with frequencies up to 500 MHz and 10 gigabits/s INTERNATIONAL ELECTROTECHNICAL COMMISSION SICS 31.220.10 PRICE CODEISBN 2-8318-1086-6 Registered trademark of the International Electrotechnical Commission DD IEC/PAS 61076-2-110:2010
7、 2 PAS 61076-2-110 IEC:2010(E) CONTENTS FOREWORD.4 1 General information7 1.1 Scope7 1.2 Recommended method of termination .7 1.2.1 Number of contacts or contact cavities 7 1.3 Ratings and characteristics .7 1.4 Normative references 7 1.5 Marking .8 1.6 Safety aspects.8 2 Technical information .8 2.
8、1 Definitions .8 2.2 Survey of styles and variants.8 3 Dimensions 8 3.1 General .8 3.2 Interface dimensions .9 3.3 Gauges .9 3.3.1 Sizing gauges and retention force gauges .9 4 Characteristics .10 4.1 Climatic category.10 4.2 Electrical .10 4.2.1 Rated voltage Rated impulse voltage Pollution degree.
9、10 4.2.2 Voltage proof.10 4.2.3 Current-carrying capacity.11 4.2.4 Contact resistance.11 4.2.5 Insulation resistance11 4.3 Mechanical11 4.3.1 IP degree of protection 11 4.3.2 Mechanical operation 11 4.3.3 Insertion and withdrawal forces .11 4.3.4 Contact retention in insert12 4.3.5 Polarizing method
10、12 4.3.6 Vibration (sinusoidal).12 4.3.7 Shock 12 5 Test schedule.12 5.1 General .12 5.1.1 Arrangement for contact resistance measurements13 5.1.2 Arrangement for dynamic stress tests (vibration) .13 5.2 Test schedule14 5.2.1 Test group P-Preliminary.14 5.2.2 Test group AP Dynamic/ Climatic15 5.2.3
11、Test group BP Mechanical endurance.17 5.2.4 Test group CP Electrical load .18 5.2.5 Test group DP Chemical resistivity .18 5.2.6 Test group EP Connection method tests .19 5.2.7 Test group FP Electrical transmission requirements .19 DD IEC/PAS 61076-2-110:2010PAS 61076-2-110 IEC:2010(E) 3 Figure 1 In
12、terface dimensions free connector.9 Figure 2 Gauge dimensions .9 Figure 3 Contact resistance arrangement.13 Figure 4 Dynamic stress test arrangement .14 Table 1 Gauges .10 Table 2 Climatic category 10 Table 3 Rated voltage - Impulse voltage Pollution degree .10 Table 4 Voltage proof connectors.10 Ta
13、ble 5 Number of mechanical operations .11 Table 6 Insertion and withdrawal forces .11 Table 7 Number of test specimens .13 Table 8 Test group P .15 Table 9 Test group AP .15 Table 10 Test group BP .17 Table 11 Test group CP .18 Table 12 Test group DP .18 Table 13 Test group EP .19 Table 14 Contact p
14、air.19 Table 15 Test group FP .20 DD IEC/PAS 61076-2-110:2010 4 PAS 61076-2-110 IEC:2010(E) INTERNATIONAL ELECTROTECHNICAL COMMISSION _ CONNECTORS FOR ELECTRONIC EQUIPMENT PRODUCT REQUIREMENTS Part 2-110: Circular connectors Detail specification for circular connectors M 12 1 with screw-locking, for
15、 high speed Ethernet and high speed data communication with frequencies up to 500 MHz and 10 gigabits/s FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The o
16、bject of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifica
17、tions (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations lia
18、ising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters expre
19、ss, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committ
20、ees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National
21、 Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not
22、 provide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All users should ensure that they have th
23、e latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever
24、, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications
25、 is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. A PAS is a technical spe
26、cification not fulfilling the requirements for a standard, but made available to the public. IEC/PAS 61076-2-110 has been prepared by subcommittee 48B: Connectors, of IEC technical committee 48: Electromechanical components and mechanical structures for electronic equipment. DD IEC/PAS 61076-2-110:2
27、010PAS 61076-2-110 IEC:2010(E) 5 The text of this PAS is based on the following document: This PAS was approved for publication by the P-members of the committee concerned as indicated in the following document Draft PAS Report on voting 48B/2096/PAS 48B/2148/RVDFollowing publication of this PAS, wh
28、ich is a pre-standard publication, the technical committee or subcommittee concerned may transform it into an International Standard. This PAS shall remain valid for an initial maximum period of 3 years starting from the publication date. The validity may be extended for a single 3-year period, foll
29、owing which it shall be revised to become another type of normative document, or shall be withdrawn. DD IEC/PAS 61076-2-110:2010 6 PAS 61076-2-110 IEC:2010(E) INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC 61076-2-110 ELECTRONIC COMPONENTS in accordance with IEC 61076-1 Circular connectors M12 1 mm 8
30、 poles, for data communication with frequencies up to 500 MHz Pin and socket connector Rewireable Non-rewireable Free cable connectors Straight and right angle connectors Fixed connectors Flange mounting Rear mounting Single hole mounting DD IEC/PAS 61076-2-110:2010PAS 61076-2-110 IEC:2010(E) 7 CONN
31、ECTORS FOR ELECTRONIC EQUIPMENT PRODUCT REQUIREMENTS Part 2-110: Circular connectors Detail specification for circular connectors M 12 1 with screw-locking, for high speed Ethernet and high speed data communication with frequencies up to 500 MHz and 10 gigabits/s 1 General information Throughout thi
32、s detail specification dimensions are in mm. 1.1 Scope This Publicly Available Specification (PAS) describes M12 circular connectors for use in industrial environments for high speed Ethernet and high speed data transfer. Applications include, but are not limited to, vision systems and data acquisit
33、ion. Screw locking M12 connectors consist of fixed and free connectors. Male connectors have round contacts 0,6mm. 1.2 Recommended method of termination The contact terminations shall be of the following types: screw, crimp, insulation piercing, and insulation displacement. 1.2.1 Number of contacts
34、or contact cavities Connector type H M12 2 to 8 contacts 1.3 Ratings and characteristics Rated voltage: 48 V, see 4.2.1, Table 3 Current rating: 0,5 A, see 4.2.3 Insulation resistance: 108, see 4.2.5 Climatic category: 25 C /+85 C / 21 days see 4.1, Table 2 Contact spacing: see Clause 3 1.4 Normativ
35、e references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60050-581, International Electro
36、technical Vocabulary Electromechanical components for electronic equipment DD IEC/PAS 61076-2-110:2010 8 PAS 61076-2-110 IEC:2010(E) IEC 60068-1:1988, Environmental testing Part 1: General and guidance Amendment 1 (1992) IEC 60352-2, Solderless connections Part 2: Crimped connections General require
37、ments, test methods and practical guidance IEC 60512 (all parts), Connectors for electronic equipment Tests and measurements IEC 60512-1-100, Connectors for electronic equipment Tests and measurements Part 1-100: General Applicable publications IEC 60529:1989, Degrees of protection provided by enclo
38、sures (IP code) IEC 60664-1, Insulation coordination for equipment within low-voltage systems Part 1: Principles, requirements and tests IEC 61076-1, Connectors for electronic equipment Product requirements Part 1: Generic specification IEC 61076-2, Connectors for use in d.c., low-frequency analogue
39、 and digital high speed data applications Part 2: Circular connectors with assessed quality Sectional specification IEC 61076-2-101:2008, Connectors for electronic equipment Product requirements Part 2-101: Circular connectors Detail specification for M12 connectors with screw-locking IEC 61984, Con
40、nectors Safety requirements and tests ISO 1302, Geometrical Product Specifications (GPS) Indication of surface texture in technical product documentation 1.5 Marking The marking of the connector and the package shall be in accordance with 2.6 of IEC 61076-2. 1.6 Safety aspects For safety aspects IEC
41、 61984 shall be considered unless otherwise specified. 2 Technical information 2.1 Definitions For the purposes of this PAS, the terms and definitions given in IEC 60050-581 apply. 2.2 Survey of styles and variants Subclause 2.2 of IEC 61076-2-101:2008 applies. 3 Dimensions 3.1 General All dimension
42、s in this document are in mm. Drawings are shown in the first angle projection. The shapes of the connectors may deviate from those given in the following drawings as long as the specified dimensions are not influenced. DD IEC/PAS 61076-2-110:2010PAS 61076-2-110 IEC:2010(E) 9 For connector dimension
43、s, see 2.2. Missing dimensions shall be chosen according to the common characteristics and intended use. The missing interface dimensions of the female styles shall be chosen according to the common characteristics of the male styles. 3.2 Interface dimensions Figure 1 Interface dimensions free conne
44、ctor 3.3 Gauges 3.3.1 Sizing gauges and retention force gauges Material: tool steel, hardened = Surface roughness according to ISO 1302: Ra = 0,25 m max. 0,15 m min. Figure 2 Gauge dimensions DD IEC/PAS 61076-2-110:2010 10 PAS 61076-2-110 IEC:2010(E) Table 1 Gauges Gauge Mass g Application amm L min
45、 mm P31 - Sizing 0,63 10 P32 20 Retention force 0,57 10 4 Characteristics 4.1 Climatic category Conditions: IEC 60068-1 Table 2 Climatic category Category of temperature Damp heat steady-state Climatic category Lower C Upper C Temperature C Relative humidity % Days 25/85/21 25 +85 40 93 21 4.2 Elect
46、rical 4.2.1 Rated voltage Rated impulse voltage Pollution degree Conditions: IEC 60664-1 The permissible rated voltage depends on the application or specified safety requirement. Reductions in creepage or clearance distances may occur due to the printed board or wiring used and shall be duly taken i
47、nto account. Table 3 Rated voltage - Impulse voltage Pollution degree Contact arrangement according to Clause 3 Rated voltage V Rated impulse voltage kV IP 65/67 variants Pollution degree b)8 poles 48 1,5 3 a) In mated condition. b) The rated voltage and impulse voltage are based on pollution degree
48、 2. This results from application of the rules of IEC 60664-1. 4.2.2 Voltage proof Conditions: IEC 60512-4-1, Test 4a Standard atmospheric conditions Mated connectors Table 4 Voltage proof connectors Between contacts Impulse withstand voltage (kV) Between contacts and metal housing Impulse withstand
49、 voltage (kV) Contact arrangement according to 3.2 Fixed connectors Free connectors Fixed connectors Free connectors 0,5 0,5 0,5 0,5 DD IEC/PAS 61076-2-110:2010PAS 61076-2-110 IEC:2010(E) 11 4.2.3 Current-carrying capacity Conditions: IEC 60512, Test 5a All contacts Values at 40 C ambient temperature 8 pole (0,25mm2wire gauge) = 0,5 A (single