1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 1629:2011Pedestrian doorsets, windows,curtain walling, grilles andshutters Burglar resistance Test method for thedetermination of resistanceunder dynamic loadingLicensed Co
2、py: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 14/09/2011 03:23, Uncontrolled Copy, (c) BSIBS EN 1629:2011 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 1629:2011. It supersedes DD ENV 1629:1999, which is withdrawn.BSI, as a member of CEN, is obliged publish EN 1
3、627, EN 1628, EN 1629, and EN 1630 as British Standards. However, attention is drawn to the fact that, during the development of these European Standards, the UK committee voted against the approval of EN 1627, EN 1628, and EN 1630, and appealed against the ratification of all four standards.This is
4、 due to the committees belief that the standards do not address all known burglary modus operendi and do not account for lock picking within any of their scopes. Users are to be drawn, in this case, to the existence of PAS 24, which provides enhanced security performance requirements for door assemb
5、lies.NOTE: A revision of PAS 24 to include windows will commence in 2011.The UK participation in its preparation was entrusted to Technical Committee B/538, Doors, windows, shutters, hardware and curtain walling.A list of organizations represented on this committee can be obtained on request to its
6、secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. BSI 2011ISBN 978 0 580 54356 2ICS 13.310; 91.060.50Compliance with a British Standard cannot confer immunity from legal obligations.This British Stand
7、ard was published under the authority of the Standards Policy and Strategy Committee on 30 June 2011.Amendments issued since publicationDate Text affectedLicensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 14/09/2011 03:23, Uncontrolled Copy, (c) BSIBS EN 1629:2011EUROPEAN STANDARD NORME EUROPENN
8、E EUROPISCHE NORM EN 1629 May 2011 ICS 13.310; 91.060.50 Supersedes ENV 1629:1999English Version Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under dynamic loading Blocs-portes pour pitons, fentres, faades
9、rideaux, grilles et fermetures - Rsistance leffraction - Mthode dessai pour la dtermination de la rsistance la charge dynamique Tren, Fenster, Vorhangfassaden, Gitterelemente und Abschlsse - Einbruchhemmung - Prfverfahren fr die Ermittlung der Widerstandsfhigkeit unter dynamischer Belastung This Eur
10、opean Standard was approved by CEN on 2 December 2010. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
11、concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN membe
12、r into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,
13、Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marn
14、ix 17, B-1000 Brussels 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1629:2011: ELicensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 14/09/2011 03:23, Uncontrolled Copy, (c) BSIBS EN 1629:2011EN 1629:2011 (E) 2 Contents P
15、age Foreword . 31 Scope 42 Normative references . 43 Terms and definitions . 54 Apparatus 54.1 Test rig . 54.2 Pendulum impactor . 54.3 Suspension system 64.4 Sub-frame 64.5 Measuring equipment . 65 Test specimen . 65.1 General . 65.2 Preparation and examination of the test specimen . 76 Procedure 7
16、6.1 Test room climate . 76.2 Impact points, directions and test sequence . 86.2.1 General . 86.2.2 Group 1, Group 2 and Group 3 products 86.2.3 Group 4 products 96.3 Impact test procedure. 107 Expression of results 108 Test report . 10Annex A (normative) Test equipment and impact points . 12A.1 Exam
17、ple of a test rig . 12A.2 Load impactor . 13A.3 Examples of mounting arrangements for doorsets 15A.4 Examples of mounting arrangements for windows 17A.5 Examples of mounting arrangements for wing and folding shutters 18A.6 Examples of mounting arrangements for guide rails and roller shutters into th
18、e test rig 20A.7 Examples of mounting arrangements for grilles into in the test rig 23A.8 Impact points for doors 25A.9 Impact points for windows . 27A.10 Impact points for shutters 28A.11 Impact points for grilles . 31Annex B (normative) Test sequence for dynamic loading test in resistance classes
19、1 to 3 33Bibliography . 34Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 14/09/2011 03:23, Uncontrolled Copy, (c) BSIBS EN 1629:2011EN 1629:2011 (E) 3 Foreword This document (EN 1629:2011) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and cur
20、tain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by November 2011, and conflicting national standards shall be withdrawn at the latest by Nove
21、mber 2011. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes ENV 1629:1999. This European Standard is one of a
22、series of standards for burglar resistant pedestrian doorsets, windows, curtain walling, grilles and shutters. The other standards in the series are: EN 1627:2011, Pedestrian doorsets, windows, curtain walling, grilles and shutters Burglar resistance Requirements and classification; EN 1628:2011, Pe
23、destrian doorsets, windows, curtain walling, grilles and shutters Burglar resistance Test method for the determination of resistance under static loading; EN 1630:2011, Pedestrian doorsets, windows, curtain walling, grilles and shutters Burglar resistance Test method for the determination of resista
24、nce to manual burglary attempts. This standard is a revision of, and supersedes ENV 1629:1999. The three other standards in this series are revisions of, and supersede ENV 1627, ENV 1628 and ENV 1630 respectively. This revision incorporates grilles and curtain walling in the range of application. Th
25、e test described in this standard is intended to simulate physical attacks, e.g. shoulder charge, kicking. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cro
26、atia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Licensed Copy: Wang Bin, IS
27、O/EXCHANGE CHINA STANDARDS, 14/09/2011 03:23, Uncontrolled Copy, (c) BSIBS EN 1629:2011EN 1629:2011 (E) 4 1 Scope This European Standard specifies a test method for the determination of resistance to dynamic loading in order to assess the burglar resistant properties of pedestrian doorsets, windows,
28、 curtain walling, grilles and shutters. It is applicable to the following means of opening: Turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically) and rolling as well as fixed constructions. There are two aspects to the burglar resistance performance of co
29、nstruction products, their normal resistance to forced operation and their ability to remain fixed to the building. Due to the limitation of reproducing the fixing methods and building construction in a laboratory environment this aspect is not fully covered by the standard. This is particularly tru
30、e with products built into a building. The performance of the fixed part of the product is evaluated using a standard sub frame. It is the manufacturers responsibility to ensure that guidance on the fixing of the product is contained in the mounting instructions and that this guidance is suitable fo
31、r the burglar resistance class claimed for the product. As with the other referenced standards this specification uses a standard sub frame and the product is mounted according to the manufacturers instructions. The fixing method to be considered is detailed in Annex A of EN 1627:2011. This test met
32、hod does not evaluate the performance of the fixing to the building. This European Standard does not apply to doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or drive
33、n by persons in industrial, commercial or residential premises, as covered by EN 13241-1. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition
34、 of the referenced document (including any amendments) applies. EN 356:1999, Glass in building Security glazing Testing and classification of resistance against manual attack EN 1303:2005, Building hardware Cylinders for locks Requirements and test methods EN 1627:2011, Pedestrian doorsets, windows,
35、 curtain walling, grilles and shutters Burglar resistance Requirements and classification EN 1628:2011, Pedestrian doorsets, windows, curtain walling, grilles and shutters Burglar resistance Test method for the determination of resistance under static loading EN 1630:2011, Pedestrian doorsets, windo
36、ws, curtain walling, grilles and shutters Burglar resistance Test method for the determination of resistance to manual burglary attempts EN 1906:2010, Building hardware Lever handles and knob furniture Requirements and test methods EN 12209:2003, Building hardware Locks and latches Mechanically oper
37、ated locks, latches and locking plates Requirements and test methods EN 12600:2002, Glass in building Pendulum test Impact test method and classification for flat glass Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 14/09/2011 03:23, Uncontrolled Copy, (c) BSIBS EN 1629:2011EN 1629:2011 (E)
38、5 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 1627:2011 and the following apply. 3.1 attack side side of the test specimen defined by the applicant as the side exposed to attack 3.2 non-attack side side of the test specimen defined by the applican
39、t as the side not exposed to attack 3.3 test specimen complete, fully functioning construction product as detailed in the scope of this standard 3.4 sub-frame surrounding frame into which the test specimen is mounted in accordance with the manufacturers instructions 3.5 test rig surrounding substant
40、ial steel frame with movable steel supports into which the sub-frames containing test specimens of various dimensions can be mounted 3.6 impacting unit impactor suspended by means of a suitable steel cable, as a pendulum of fixed length, with a release hook and height regulating device 3.7 impactor
41、body used to strike the test specimen 3.8 impact point position on the surface of the test specimen where the dynamic load is applied 4 Apparatus 4.1 Test rig The test rig consisting of a rigid steel frame with movable steel supports into which test specimens of various dimensions can be mounted is
42、shown in Annex A, Figure A.1. The stiffness of the rig shall be such that a 15 kN force applied to any of the defined points and normal to the plane of the frame will not cause a deflection of more than 5 mm and shall not affect the results of the test. The test rig shall not impede the execution of
43、 the test. 4.2 Pendulum impactor The pendulum impactor, conforming to EN 12600:2002, is listed with individual components in Table 1 and pictured in Annex A, Figure A.3. The impactor shall consist of two pneumatic tyres (type 3.50-R8 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 14/09/2011
44、03:23, Uncontrolled Copy, (c) BSIBS EN 1629:2011EN 1629:2011 (E) 6 4PR1) ) inflated to a pressure of 0,35 MPa 0,02 MPa with round section and flat longitudinal tread and shall be suspended by means of a suitable steel cable giving a minimum pendulum length of 1000 mm 10 mm, with a release hook and h
45、eight regulating device. The tyres shall be fitted to the rims (type 250-8) of wheels that carry two steel weights of equal mass. The weights shall be dimensioned so that the total mass of the impactor is 50 kg 0,1 kg (excluding the steel cable and release hook) and the weights do not have any conta
46、ct with the test specimen during the impact. The drop height shall be the vertical height through which the centre of gravity of the impactor falls, with a tolerance of 10 mm. The impactor support point shall allow the impactor to strike the test specimen at all relevant points. The complete pendulu
47、m impactor unit shall be adjustable and may be installed either on the test rig, as shown in Annex A, Figure A.1, or as an independent unit, as shown in Annex A, Figures A.2 and A.3. 4.3 Suspension system The suspension system shall conform to EN 12600:2002. 4.4 Sub-frame The sub-frame shall simulat
48、e the support given to the product when installed into a building, and shall be taken into consideration in the manufacturers installation instructions. It shall typically consist of the following: a) for group 1 to group 4 products a rectangular metal tube 120 mm x 120 mm x 5 mm or a rectangular ti
49、mber frame 100 mm x 50 mm; b) additionally for group 3 products and group 4 products a steel tube 40 mm x 40 mm x 3 mm and a base plate of 8 mm steel, consisting of several segments which shall be removable for the purposes of loading, if necessary. 4.5 Measuring equipment The measuring equipment consists of the following: a) suitable device for measuring the drop