1、BS EN 299:2009ICS 27.060.10NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDOil pressureatomizing nozzles Determination ofthe angle and spraycharacteristicsThis British Standardwas published underthe authority of theStandards Policy andStrategy Committee on 30Sep
2、tember 2009 BSI 2009ISBN 978 0 580 65088 8Amendments/corrigenda issued since publicationDate CommentsBS EN 299:2009National forewordThis British Standard is the UK implementation of EN 299:2009. Itsupersedes BS EN 299:1999 which is withdrawn.The UK participation in its preparation was entrusted to T
3、echnicalCommittee GSE/27, Automatic gas and oil burners.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Complianc
4、e with a British Standard cannot confer immunityfrom legal obligations.BS EN 299:2009EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 299August 2009ICS 27.060.10 Supersedes EN 299:1998 English VersionOil pressure atomizing nozzles - Determination of the angle andspray characteristicsGicleurs sans r
5、etour pour brleurs fioul domestique pulvrisation - Dtermination de langle et descaractristiques de pulvrisationldruckzerstuberdsen - Prfung der Sprhcharakteristikund des WinkelsThis European Standard was approved by CEN on 23 July 2009.CEN members are bound to comply with the CEN/CENELEC Internal Re
6、gulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This
7、European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the n
8、ational standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and
9、 United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 299:2009: EBS
10、 EN 299:2009EN 299:2009 (E) 2 Contents Page Foreword 3 1 Scope 4 2 Normative references 4 3 Terms and definitions .4 4 Testing 4 4.1 Testing of the radial distribution/spray pattern 4 4.1.1 Test equipment 4 4.1.2 Test procedure .5 4.1.3 Processing of test data .5 4.1.4 Spray uniformity and angle rat
11、io 5 4.1.5 Classification of pattern types .5 4.2 Testing of the index angle 5 4.2.1 Test equipment 5 4.2.2 Test procedure .6 4.2.3 Processing of test data .6 4.2.4 Computation of index angle .6 4.3 Explanations .9 BS EN 299:2009EN 299:2009 (E) 3 Foreword This document (EN 299:2009) has been prepare
12、d by Technical Committee CEN/TC 47 “Atomizing oil burners and their components - Function - Safety - Testing”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest
13、 by February 2010, and conflicting national standards shall be withdrawn at the latest by February 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all s
14、uch patent rights. This document supersedes EN 299:1998. The main change from the previous edition is that the test equipment in Figure 1 is now dimensioned. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this
15、 European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the U
16、nited Kingdom. BS EN 299:2009EN 299:2009 (E) 4 1 Scope This European Standard specifies a method for the determination of the spray characteristic and the index angle of oil pressure atomizing nozzles. 2 Normative references The following referenced documents are indispensable for the application of
17、 this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 293, Oil pressure atomizing nozzles Minimum requirements Testing 3 Terms and definitions For the purposes of this documen
18、t, the following terms and definitions apply: 3.1 radial spray distribution-spray angle variation in liquid flux when proceeding from the nozzle axis to the edge of the conical spray pattern at a specified distance from the atomizer 3.2 index angle Y plane angle formed by a conical spray, wherein th
19、e magnitude of the angle is determined by a specified percentage, e.g. 80 %, of the total volume of liquid collected in a radial patternator 3.3 cumulative volume aggregate volume of liquid, expressed as a percentage of the total volume collected in a radial patternator, when proceeding from the spr
20、ay axis (centre of the patternator) to the edge of the spray pattern 3.4 radial patternator device comprising a series of concentric annular compartments with a row of collection cylinders that is capable of measuring the radial spray distribution, as defined in 3.1 3.5 index arbitrary number assign
21、ed to a group of oil burner nozzles having similar spray patterns EXAMPLE “I“ indicating “solid“, see Table 1. 4 Testing 4.1 Testing of the radial distribution/spray pattern 4.1.1 Test equipment The radial patternator, as shown in Figures 1 and 2, shall be a cylindrical vessel having a bottom plate
22、comprising 14 concentric dividers that provide annular compartments from which liquid may be drained into graduated collection cylinders. BS EN 299:2009EN 299:2009 (E) 5 During testing, the top of the vessel shall be covered with a lid at whose centre a nozzle holder shall be mounted, which shall be
23、 vertically adjustable, so that the specified distance can be maintained between the nozzle orifice and the upper bevelled edges of the dividers. Means shall be taken to ensure that the annular compartments and collection cylinders are not exposed to the spray prior or subsequent to the period desig
24、nated for the collection of liquid. 4.1.2 Test procedure The nozzle to be tested shall be mounted in the nozzle holder. The latter shall be adjusted so that the axial distance between the nozzle orifice and the upper edges of the dividers is 50 mm. Testing shall be conducted with a reference oil as
25、specified by EN 293. The total volume atomized during each test shall be at least 80 ml and shall in any case be sufficient to provide representative quantities of liquid in the collection cylinders. At the conclusion of each test, the liquid volumes in each cylinder shall be recorded. 4.1.3 Process
26、ing of test data The recorded liquid volumes shall be tabulated along with the corresponding cumulative percentage volumes (see Table 3). Using the listed plane angles for each annular compartment, the cumulative volume (starting at the centre of the patternator) may be correlated with the plane ang
27、le subtended by that volume. Using this procedure, the continuous radial distribution may be represented in tabular or graphical form. 4.1.4 Spray uniformity and angle ratio The radial mass-distribution is a measure of spatial uniformity at a specified distance from the atomizer. For example, a nozz
28、le with “solid“ spray pattern is relatively uniform, whereas a nozzle with “hollow“ spray pattern is characterized by a high concentration of liquid at the outside of the spray cane. An indication of uniformity or pattern type can be given by calculating the 50 % / 80 % angle ratio. The two angles w
29、hich correspond to the 50 % and 80 % cumulative volumes respectively may be determined by linear interpolation between the values (see Table 3) that bracket the 50 % and 80 % points in Table 3 (see 4.2.4). 4.1.5 Classification of pattern types The defined angle ratio shall be the basis for classifyi
30、ng spray pattern to the arbitrary indices in Table 1. Table 1 Index 50 % / 80 % angle ratio Qualitative description of spray pattern I 0,700 solidII 0,700 to 0,749 semi-solidIII 0,75 to 0,799 semi-hollow IV 0,800 hollow 4.2 Testing of the index angle 4.2.1 Test equipment See 4.1.1. BS EN 299:2009EN
31、299:2009 (E) 6 4.2.2 Test procedure See 4.1.2. 4.2.3 Processing of test data See 4.1.3. 4.2.4 Computation of index angle The index angle for this standard is quantitatively defined as the 80 % angle. This is the angle according to Equation (1) corresponding to the inner angle where 80 % of the liqui
32、d volume is collected. ()( )()+=121VVVVY (1) where Y is the index angle; V is 50 %, if the 50 % index angle is to be computed, 80 %, if the 80 % index angle is to be computed; V1is the cumulative volume in percent collected in all patternator compartments up to and including the compartment such tha
33、t V1is as large as possible without exceeding the value of 80 %, if the 80 % angle is computed, or without exceeding 50 %, if the 50 % angle is computed; V2is the cumulative volume in percent collected in all patternator compartments up to and including the compartment such that V2is as small as pos
34、sible but still exceeds the value of 80 %, if the 80 % angle is computed, or still exceeds the value of 50 %, if the 50 % is computed; is the plane angle subtended by outer edge of compartment corresponding to V1; is the plane angle subtended by outer edge of compartment corresponding to V2.Table 2
35、Angle marking degrees Tested angle degrees 50 45 to 55 60 56 to 65 70 66 to 75 80 76 to 85 90 86 to 95 100 96 to 105 BS EN 299:2009EN 299:2009 (E) 7 Dimensions in millimetres Figure 1 BS EN 299:2009EN 299:2009 (E) 8 Dimensions in millimetres Figure 2 BS EN 299:2009EN 299:2009 (E) 9 Table 3 Tube No.
36、Collected tube volumeml Cumulative volume % Plane angle degrees 1 2 1,923077 14,52 9 10,57632 28,53 14 24,03846 41,7 4 22,5 45,67308 53,95 25 69,71153 64,86 14,5 83,65384 74,6 7 5,5 88,9423 83,38 3 91,82691 90,99 2,5 94,23076 97,6 10 2 96,15384 103,611 98,07692 108,812 2 100,0 113,5 13 0 100,0 121,3
37、14 100,0 128,5EXAMPLE Example showing collected liquid volumes, conversion to cumulative percent volume, and corresponding plane angles: Test references: oil burner nozzle “Hollow“ 0,85 GPH 60 Pressure: 10 bar The test shall be performed with a reference oil as defined in EN 293. Total volume collec
38、ted = 104,0 ml The plane angle at 50 % (deg.) = 55,86201 The plane angle at 80 % (deg.) = 72,03173 The 50 % / 80 % cumulative volume plane angle ratio = 0,7755194 4.3 Explanations The determination of spray angle by observation, photography, or by use of a protractor device (goniometer) is likely to
39、 produce erratic and non-repeatable result due to differences in instrumentation and test procedures. This has led to significant variations among nozzles marketed by different manufacturers, even though the nominal angle ratings may be identical. Index angles defined and calculated in this way are
40、likely to exceed those values determined visually or by angle measurement devices. BS EN 299:2009BSI GroupHeadquarters 389Chiswick High Road,London, W4 4AL, UKTel +44 (0)20 8996 9001Fax +44 (0)20 8996 - British Standards InstitutionBSI is the independent national body responsible for preparing Brit
41、ishStandards. It presents the UK view on standards in Europe and at theinternational level. It is incorporated by Royal Charter.RevisionsBritish Standards are updated by amendment or revision. Users of BritishStandards should make sure that they possess the latest amendments oreditions.It is the con
42、stant aim of BSI to improve the quality of our products and services.We would be grateful if anyone finding an inaccuracy or ambiguity while usingthis British Standard would inform the Secretary of the technical committeeresponsible, the identity of which can be found on the inside front cover. Tel:
43、+44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400.BSI offers members an individual updating service called PLUS which ensuresthat subscribers automatically receive the latest editions of standards.Buying standardsOrders for all BSI, international and foreign standards publications should beaddressed to
44、Customer Services. Tel: +44 (0)20 8996 9001. Fax: +44 (0)20 89967001 Email: You may also buy directly using a debit/creditcard from the BSI Shop on the Website http:/ response to orders for international standards, it is BSI policy to supply theBSI implementation of those that have been published a
45、s British Standards,unless otherwise requested.Information on standardsBSI provides a wide range of information on national, European andinternational standards through its Library and its Technical Help to ExportersService. Various BSI electronic information services are also available whichgive de
46、tails on all its products and services. Contact Information Centre. Tel:+44 (0)20 8996 7111 Fax: +44 (0)20 8996 7048 Email: Subscribing members of BSI are kept up to date with standards developmentsand receive substantial discounts on the purchase price of standards. For detailsof these and other be
47、nefits contact Membership Administration. Tel: +44 (0)208996 7002 Fax: +44 (0)20 8996 7001 Email: Information regarding online access to British Standards via British StandardsOnline can be found at http:/ information about BSI is available on the BSI website at http:/.CopyrightCopyright subsists in
48、 all BSI publications. BSI also holds the copyright, in theUK, of the publications of the international standardization bodies. Except aspermitted under the Copyright, Designs and Patents Act 1988 no extract maybe reproduced, stored in a retrieval system or transmitted in any form or by anymeans ele
49、ctronic, photocopying, recording or otherwise without prior writtenpermission from BSI.This does not preclude the free use, in the course of implementing the standard,of necessary details such as symbols, and size, type or grade designations. Ifthese details are to be used for any other purpose than implementation then theprior written permission of BSI must be obtained.Detai