1、BRITISH STANDARDBS EN 3661-005:2006Aerospace series Circuit breakers, single-pole, temperature compensated, rated current 20 A to 50 A Part 005: With polarized signal contact Product standardThe European Standard EN 3661-005:2006 has the status of a British StandardICS 49.060g49g50g3g38g50g51g60g44g
2、49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58Licensed Copy: Wang Bin, na, Thu Apr 05 07:23:26 GMT+00:00 2007, Uncontrolled Copy, (c) BSIBS EN 3661-005:2006This British S
3、tandard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2007 BSI 2007ISBN 978 0 580 50007 7National forewordThis British Standard was published by BSI. It is the UK implementation of EN 3661-005:2006. The UK participation in its preparation was entruste
4、d by Technical Committee ACE/6, Aerospace avionic electrical and fibre optic technology, to Panel ACE/6/-/5, Aerospace Protection for electrical systems.A list of organizations represented on ACE/6/-/5 can be obtained on request to its secretary.This publication does not purport to include all the n
5、ecessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments issued since publicationAmd. No. Date CommentsLicensed Copy: Wang Bin, na, Thu Apr 05 07:23:26 GMT+00:00 2007, Uncontrolled
6、 Copy, (c) BSIEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 3661-005August 2006ICS 49.060English VersionAerospace series - Circuit breakers, single-pole, temperaturecompensated, rated current 20 A to 50 A - Part 005: Withpolarized signal contact - Product standardSrie arospatiale - Disjoncteurs
7、unipolaires compenss entemprature, intensits nominales 20 A 50 A - Partie 005: Avec contact de signalisation polaris - Norme de produitLuft- und Raumfahrt - Schutzschalter, einpolig,Temperaturkompensiert, Nennstrme von 20 A bis 50 A -Teil 005: Mit polarisiertem Signalkontakt - ProduktnormThis Europe
8、an Standard was approved by CEN on 5 June 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concernin
9、g such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own languag
10、e and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
11、Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2006 CEN All rights of exploitatio
12、n in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 3661-005:2006: ELicensed Copy: Wang Bin, na, Thu Apr 05 07:23:26 GMT+00:00 2007, Uncontrolled Copy, (c) BSI2 Contents Page Foreword3 1 Scope 4 2 Normative references 4 3 Dimensions and mass.4 4 Characteristics.6 5
13、Designation 10 6 Rated current code 11 7 Delivery codes11 8 Marking .11 9 Technical specification .11 EN 3661-005:2006Licensed Copy: Wang Bin, na, Thu Apr 05 07:23:26 GMT+00:00 2007, Uncontrolled Copy, (c) BSI3 Foreword This European Standard (EN 3661-005:2006) has been prepared by the Aerospace and
14、 Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its
15、presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2007, and conflicting national standards shall be withdrawn at the latest by February 2007. Attention is drawn to the
16、possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countri
17、es are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, S
18、witzerland and the United Kingdom. EN 3661-005:2006Licensed Copy: Wang Bin, na, Thu Apr 05 07:23:26 GMT+00:00 2007, Uncontrolled Copy, (c) BSI4 1 Scope This standard specifies the characteristics of single-pole circuit breakers, temperature compensated with a rated current from 20 A to 50 A, used in
19、 aircraft on-board circuits at a temperature between 55 C and 125 C and at an altitude of 15 000 m max. These circuit breakers are operated by a push-pull type single push button (actuator), with delayed action “trip-free“ tripping with a polarized signal contact which is open when main contacts are
20、 closed, and inversely. They will continue to function up to the short-circuit current. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition o
21、f the referenced document (including any amendments) applies. EN 3155-016, Aerospace series Electrical contacts used in elements of connection Part 016: Contacts, electrical, male, type A, crimp, class S Product standard. EN 3661-001, Aerospace series Circuit breakers, single-pole, temperature compe
22、nsated, rated current 20 A to 50 A Part 001: Technical specification. EN 3841-305, Aerospace series Circuit breakers Test methods Part 305: Short-circuit performance. EN 6113, Aerospace series Circuit breaker, connecting and attachment hardware.1)TR 6083, Aerospace series Cut-outs for installation o
23、f electrical components.2)MIL-I-81969/1A, Installing and removal tools, connector electrical contact, type III, class 2, composition C.3)MIL-I-81969/14C, Installing and removal tools, connector electrical contact, type III, class 2, composition B.3)MIL-S-19500, Semiconductor device, diode, silicon,
24、fast recovery.3)FED-STD-595B, Colors used in Government Procurement. 3 Dimensions and mass 3.1 Dimensional characteristics The circuit breakers do not have to correspond to the pictorial illustration, only the dimensions given shall be adhered to. Dimensions are in millimetres. See Figure 1. 1) Publ
25、ished as AECMA Prestandard at the date of publication of this standard. 2) Published as AECMA Technical Report at the date of publication of this standard. 3) Published by: Department of Defense (DOD), the Pentagon, Washington D.C. 20301 USA. EN 3661-005:2006Licensed Copy: Wang Bin, na, Thu Apr 05 0
26、7:23:26 GMT+00:00 2007, Uncontrolled Copy, (c) BSI5 Key 1 Push button released 9 1 to 3 max. 2 Green colour according to FED-STD-595B No. 34090 10 3 White Gauge 20 connection pins according to EN3155-016M2018 4 Marking area, see Clause 8. 11 Indicative value 25 (see note) 5 Connecting screw and wash
27、er 12 6 Push button pressed Positioning lug in accordance with the panel cut-out, as per TR6083C202 7 Lockwasher 13 Rated current marking (white on green) 8 Attachment nut F1 and F2: see EN 3661-001 “Mechanical tests“. NOTE Tools noted in Subclause 4.2.4 shall be applied without interfering with the
28、 terminal 2 connection, even if the circuit breakers are grouped. Figure 1 Configuration Dimensions Tolerances 110,5 A55320-123M12 x 0,75 10,2 0,33 min.2 0,3A21 0,52519,5 max.12F1 and F2 : see EN 3661-001, table 334 max.42 max.10 min.10 min.10 9,2 0,3926,5 0,3180-123148128max.6,60,654+104533 max.7mi
29、n.4531325 max.14687F2F1EN 3661-005:2006Licensed Copy: Wang Bin, na, Thu Apr 05 07:23:26 GMT+00:00 2007, Uncontrolled Copy, (c) BSI6 3.2 Electrical diagram See Figure 2. Terminal No.: 1 and 2: Main contacts 3 and 5: Signal contacts Figure 2 Electrical diagram 3.3 Mass 75 g max. (delivery code A inclu
30、ding hardware). 3.4 Panel mounting See EN 3661-001. 4 Characteristics 4.1 Material, surface treatment See EN 3661-001. 4.2 Mechanical characteristics 4.2.1 Fasteners See EN 6113. 4.2.2 Recommended tightening torque of attaching nut for installation (5,25 0,25) Nm. 4.2.3 Recommended tightening torque
31、 of connection hardware for installation (2,35 0,15) Nm. 4.2.4 Recommended tools for contacts of auxiliary contact insertion and extraction plastic MIL-I-81969/14-11; metallic MIL-I-81969/1-02. 213 5Push-button released2135Push-button pressed3 5or35orEN 3661-005:2006Licensed Copy: Wang Bin, na, Thu
32、Apr 05 07:23:26 GMT+00:00 2007, Uncontrolled Copy, (c) BSI7 4.2.5 Resistance to vibrations 4.2.5.1 Combined test: ambient temperature at 70 C and vibrations Sinusoidal: 10 gn, see EN 3661-001. Random: 5,8 gn, see EN 3661-001. Low frequencies: 10 gn, see EN 3661-001. 4.2.5.2 Combined test: ambient te
33、mperature at 85 C, altitude and vibrations Sinusoidal: 3 gn, see EN 3661-001. 4.2.6 Resistance to shocks 50 gn, see EN 3661-001. 4.2.7 Mechanical endurance See Table 6. 4.3 Environment characteristics 4.3.1 Humidity See EN 3661-001. 4.3.2 Corrosion See EN 3661-001. 4.3.3 Contaminating fluids See EN
34、3661-001. 4.3.4 Over-voltage caused by lightning See EN 3661-001. 4.4 Electrical characteristics 4.4.1 Nominal voltages of main contacts See Table 1. Table 1 28 V d.c. 26 V a.c., 360 Hz to 800 Hz Nominal voltage 115 V a.c., 360 Hz to 800 Hz EN 3661-005:2006Licensed Copy: Wang Bin, na, Thu Apr 05 07:
35、23:26 GMT+00:00 2007, Uncontrolled Copy, (c) BSI8 4.4.2 Diode of signal contact characteristic Maximum current at 125 C: 0,5 A. Peak repetitive reversal voltage: 800 V min. Quality standard: JANTX according to MIL-S-19500. 4.4.3 Voltage drop at nSee Table 2. Table 2 Ratings A 20 25 30 35 40 45 50 U
36、max. at n V 0,15 0,15 0,15 0,15 0,12 0,12 0,12 Signal circuit: 28 V d.c.; I = 3 mA : U 1,0 V. NOTE When a signal contact has been operated with a power greater than 60 mW and/or with a voltage higher than 28 V d.c., it loses its low current quality. 4.4.4 Minimum and maximum tripping thresholds See
37、Table 3. Table 3 Overload (in % of n) Minimum thresholds value 1 h Maximum thresholds value 1 h Ambient temperatures C Ratings On ground At 15 000 m On ground 23 5 110 105 145 55 5 110 105 165 70 5 105 100 145 125 5 All 90 80 145 4.4.5 Overload trip See Table 4. EN 3661-005:2006Licensed Copy: Wang B
38、in, na, Thu Apr 05 07:23:26 GMT+00:00 2007, Uncontrolled Copy, (c) BSI9 Table 4 Overload (in % of n) 200 500 1 000 Ambient temperatures C Ratings A Trip time s 23 5 4 to 15 55 5 70 125 5 All 1,5 0,15 to 2,50 0,045 to 0,600 4.4.6 Short-circuit values See Table 5. Table 5 Nominal voltage 28 V d.c. 115
39、 V a.c., 360 Hz to 800 Hz 0,8 cos 1 Prospective currents 4 000 A L/R 1 ms 2 000 A r.m.s. Test altitudes On the ground and at maximum altitude (15 000 m, 12 100 Pa) Number of operations 1 CO a+ 2 OCO baBreak operation (for definition see EN 3841-305). bMake operation (for definition see EN 3841-305).
40、 4.4.7 No-load and load endurance See Table 6. Table 6 Number of operations to be provided No-load Load 5 000 2 500 2 500 2 500 2 500 Main contacts Applicable Not applicable Resistive n, 28 V d.c. Inductive L/R = 5 ms n, 28 V d.c. Inductive 0,6 cos 0,7n, 115 V a.c. - 360 Hz to 800 HzAll ratings Sign
41、al contacts Applicable Resistive 3 mA, 28 V d.c. Resistive 3 mA, 5 V d.c. Lamp 0,2 A, 28 V d.c. Resistive 0,5 A, 28 V d.c. NOTE 1 One operation corresponds to one closing + one opening. NOTE 2 Tolerances 5 % on current, voltage and frequency values. EN 3661-005:2006Licensed Copy: Wang Bin, na, Thu A
42、pr 05 07:23:26 GMT+00:00 2007, Uncontrolled Copy, (c) BSI10 4.4.8 Dielectric rigidity See Table 7. Table 7 Closed position Z = 0 m Z = 15 000 m 1 and 2 with attachment 1 and 2 with 3 1 and 2 with 5 1 500 V 400 V 3 with 5 3 and 5 with attachment 500 V 150 V Open position Z = 0 m Z = 15 000 m 1 with 2
43、 1 and 2 with attachment 3 and 5 with 1 3 and 5 with 2 1 500 V 400 V 3 and 5 with attachment 500 V 150 V 4.4.9 Insulation resistance According to EN 3661-001, Table 5. 5 Designation EXAMPLE Description block CIRCUIT BREAKER Identity block EN3661-005A20AA Number of EN standard Design code, A: green b
44、utton Rated current code (see Table 8) Delivery code A (see Table 9) NOTE If necessary, the code I9005 shall be placed between the description block and the identity block. EN 3661-005:2006Licensed Copy: Wang Bin, na, Thu Apr 05 07:23:26 GMT+00:00 2007, Uncontrolled Copy, (c) BSI11 6 Rated current c
45、ode See Table 8. Table 8 Rating current n (A) 20 25 30 35 40 45 50 Marking on actuator 20 25 30 35 40 45 50 Rated current code 20A 25A 30A 35A 40A 45A 50A 7 Delivery codes See Table 9. Table 9 Connection and attachment hardware kits EN 6113 Delivery conditions Delivery code Kit part-No. aIncluded pa
46、rts Pieces per part Fitted Supplied separately Connecting screw 2 Connecting lock washer 2 Attachment nut 1 A EN 6113A Attachment lock washer 1 X Attachment nut 1 B EN 6113B Attachment lock washer 1 X aSpare parts could be ordered separately, for information see EN 6113. 8 Marking As defined on the
47、drawing and unless otherwise specified by contract, marking shall include: the designation defined in Clause 5, on the packaging; the manufacture date (year, week) the manufacturers name or trademark; the electrical diagram and the terminal identification; the manufacturers part number (correspondin
48、g to the part number which includes connection and attachment hardware supplied separately in a bag). NOTE The marking could be on both opposite sides. For electrical diagram printed on the circuit breaker and/or terminal identification numbers see Figure 1. 9 Technical specification See EN 3661-001
49、. EN 3661-005:2006Licensed Copy: Wang Bin, na, Thu Apr 05 07:23:26 GMT+00:00 2007, Uncontrolled Copy, (c) BSIBS EN 3661-005:2006BSI389 Chiswick High RoadLondonW4 4ALBSI British Standards InstitutionBSI is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter.RevisionsBritish Standards are updated by