1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 4612-009:2011Aerospace series Cables,electrical, for general purpose,single and multicore assembly XLETFE Family Jacketed orscreened and jacketedPart 009: Silver plated cop
2、per Operatingtemperatures, between 65 C and 150C Dual extruded wall for open applications, with jacket without screen - UV laser printable - Product standardBS EN 4612-009:2011 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 4612-009:2011.The UK participation in
3、 its preparation was entrusted to TechnicalCommittee ACE/6, Aerospace avionic electrical and fibre optictechnology.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract.
4、Users are responsible for its correctapplication. BSI 2011ISBN 978 0 580 75530 9ICS 49.060Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 November 2011.Amendmen
5、ts issued since publicationDate T e x t a f f e c t e dBS EN 4612-009:2011EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 4612-009 October 2011 ICS 49.060 English Version Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Jacketed or scre
6、ened and jacketed - Part 009: Silver plated copper - Operating temperatures, between - 65 C and 150 C - Dual extruded wall for open applications, with jacket without screen - UV laser printable - Product standard Srie arospatiale - Cbles, lectriques, dusage gnral, mono et multiconducteurs - Famille
7、XLETFE - Gains ou blinds et gains - Partie 009: Cuivre argent - Tempratures de fonctionnement comprises entre - 65 C et 150 C - Fil double isol pour applications externes, gain non blind - Marquable au laser UV - Norme de produit Luft- und Raumfahrt - Ein- und mehradrige elektrische Leitungen fr all
8、gemeine Verwendung - XLETFE Familie - Mit Mantel oder geschirmt und Mantel - Teil 009: Kupfer versilbert - Betriebstemperaturen zwischen - 65 C und 150 C - Doppelt extrudierte Isolierung fr externe Verwendung, mit Mantel ohne Schirm - UV-Laser bedruckbar - Produktnorm This European Standard was appr
9、oved by CEN on 20 August 2011. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
10、 standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language
11、and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
12、Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2
13、011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 4612-009:2011: EBS EN 4612-009:2011EN 4612-009:2011 (E) 2 Contents Page Foreword 31 Scope 42 Normative references 43 Terms, definitions and symbols .44 Materials and construction
14、.45 Required characteristics .56 Quality assurance 87 Designation 88 Identification and marking 89 Packaging, labelling and delivery lengths 910 Technical specification .9BS EN 4612-009:2011EN 4612-009:2011 (E) 3 Foreword This document (EN 4612-009:2011) has been prepared by the Aerospace and Defenc
15、e Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its present
16、ation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by April 2012, and conflicting national standards shall be withdrawn at the latest by April 2012. Attention is drawn to the possibility t
17、hat some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound
18、to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Swe
19、den, Switzerland and the United Kingdom. BS EN 4612-009:2011EN 4612-009:2011 (E) 4 1 Scope This European Standard specifies the characteristics of UV laser printable jacket, silver plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer XLETFE family for use
20、in the on-board electrical systems of aircraft at operating temperatures between 65 C and 150 C, operating at voltages not exceeding 600 V r.m.s and frequencies not exceeding 2 000 Hz. These cables are suitable for airframe use without additional protection. In case of conflict between this standard
21、 and other referenced documents the requirements of this standard shall take precedence. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition
22、of the referenced document (including any amendments) applies. EN 2235, Aerospace series Single and multicore electrical cables, screened and jacketed EN 3475-100 (all parts), Aerospace series Cables, electrical, aircraft use Test methods Part 100: General EN 4611-006, Aerospace series Cables, elect
23、rical, for general purpose, single and multicore assembly XLETFE Family Part 006: Silver plated copper Operating temperatures, between 65 C and 150 C Dual extruded wall for openapplications UV laser printable Product standard 1)EN 4612-002, Aerospace series Cables, electrical, for general purpose, s
24、ingle and multicore assembly XLETFE Family Jacketed or screened and jacketed Part 002: General EN 9133, Aerospace series Quality management systems Qualification procedure for aerospace standard parts 3 Terms, definitions and symbols For the purposes of this document, the terms, definitions and symb
25、ols given in EN 3475-100 apply. 4 Materials and construction 4.1 Materials These cables shall consist of the following: cores according to EN 4611-006; number of cores 2 (two) to 4 (four). 1) Published as ASD-STAN Prestandard at the date of publication of this standard (www.asd-stan.org). BS EN 4612
26、-009:2011EN 4612-009:2011 (E) 5 Cores shall be twisted together according to EN 2235. Filler cores shall not be permitted. Outer jacket: it shall be possible to mark the jacket by UV laser printing; minimum thickness shall be 0,15 mm. 4.2 Construction See Table 1. Table 1 Multicore without screen, w
27、ith jacket Size AWG a2 core 3 core 4 core Max. dia. Mass DC Res. Max. dia. Mass DC Res. Max. dia. Mass DC Res. mm kg/km /km mm kg/km /km mm kg/km /km max. max. max. max. max. max. 001 b26 2,40 7,02 153,5 2,56 9,82 153,5 2,82 12,65 153,5 002 b24 2,75 9,43 109,2 2,94 13,31 109,2 3,24 17,28 109,2 004 2
28、2 2,95 12,05 60,0 3,15 17,16 60,0 3,48 22,38 60,0 006 20 3,42 18,21 32,0 3,66 26,22 32,0 4,04 34,37 32,0 010 18 3,96 25,52 20,2 4,24 36,96 20,2 4,69 48,59 20,2 012 16 4,23 32,35 15,3 4,54 47,10 15,3 5,02 62,05 15,3 020 14 5,34 46,86 10,5 5,73 68,65 10,5 6,36 90,44 10,5 030 12 6,36 70,07 6,6 6,83 102
29、,88 6,6 7,60 136,09 6,6 050 10 7,68 106,11 4,1 8,26 156,81 4,1 9,20 207,50 4,1 aAWG = Closest American Wire Gage. bSilver plated copper alloy conductor. 4.3 Colour coding of cores and jacket See EN 4612-002. 5 Required characteristics According to EN 2235 and EN 3475-100. See Table 2. BS EN 4612-009
30、:2011EN 4612-009:2011 (E) 6 Table 2 EN 3475- Test Details 201 Visual examination Applicable 202 Mass Applicable; see Table 1. 203 Dimensions Applicable; see Table 1. 301 Ohmic resistance per unit length Applicable; see Table 1. 302 Voltage proof test Applicable 303 Insulation resistance Applicable (
31、20 2) C, 500 M.km minimum (95 2) C, 1 M.km minimum 304 Surface resistance Not applicable 305 Overload resistance Not applicable 401 Accelerated ageing Applicable Temperature (200 3) C 402 Shrinkage and delamination Applicable Temperature (150 5) C Maximum shrinkage at each end of cable: Jacket: 2 mm
32、 on size 001 to 010 3 mm on size 012 to 050 Cores: 0,80 mm on size 001 to 006 1,00 mm on size 010 to 012 1,20 mm on size 020 to 030 403 Delamination and blocking Applicable Temperature (150 5) C 404 Thermal shock Applicable Temperatures ( 65 2) C and (260 5) C Maximum shrinkage at each end of cable:
33、 Jacket: 2 mm on size 001 to 010 3 mm on size 012 to 050 Cores: 0,80 mm on size 001 to 006 1,00 mm on size 010 to 012 1,20 mm on size 020 to 030 continued BS EN 4612-009:2011EN 4612-009:2011 (E) 7 Table 2 (continued) EN 3475- Test Details 405 Bending at ambient temperature Applicable 406 Cold bend t
34、est Applicable Temperature ( 65 2) C 407 Flammability Applicable Methods 1 and 2 Flame application 15 s Extinguishing time: 3 s max. 408 Fire resistance Not applicable 409 Air-excluded ageing Not applicable 410 Thermal endurance Not applicable 411 Resistance to fluids Applicable Volume swell not gre
35、ater than 10 % Scrape not applicable 412 Humidity resistance Applicable Method B Temperature (90 2) C Duration 672 hours 413 Wrap back test Not applicable 414 Differential scanning calorimeter (DSC test) Not applicable 501 Dynamic cut-through Not applicable 502 Notch propagation Not applicable 503 S
36、crape abrasion Not applicable 504 Torsion Not applicable 505 Tensile test on conductors and strands Not applicable 506 Plating continuity Not applicable 507 Adherence of plating Not applicable 508 Plating thickness Not applicable 509 Solderability Not applicable 510 Tensile strength and elongation o
37、f extruded insulation, sheath and jacket material Applicable jacket Eb 75 % minimum TS 34 MPa minimum 511 Cable-to-cable abrasion Not applicable 512 Flexure endurance Not applicable 601 Smoke density Subject to agreement between customer and supplier continued BS EN 4612-009:2011EN 4612-009:2011 (E)
38、 8 Table 2 (concluded) EN 3475- Test Details 602 Toxicity Subject to agreement between customer and supplier 603 Resistance to wet arc tracking Not applicable 604 Resistance to dry arc propagation Not applicable 605 Wet short circuit test Not applicable 701 Strippability and adherence of insulation
39、to the conductor Not applicable 702 Screen pushback capability Not applicable 703 Permanence of manufacturers marking Applicable 704 Flexibility Not applicable 705 Contrast measurement Applicable Laser marking K 50 % 706 Laser markability Not applicable 6 Quality assurance See EN 9133. 7 Designation
40、 EXAMPLE Description block CABLE, ELECTRICAL Identity block EN4612-009A010P Number of this standard Code letter for number of cores (see EN 4612-002) Code for nominal section (see Table 1) Code letter for colour coding of cores (see EN 4612-002) 8 Identification and marking See EN 4612-002. BS EN 46
41、12-009:2011EN 4612-009:2011 (E) 9 9 Packaging, labelling and delivery lengths See EN 2235. 10 Technical specification See EN 2235. This page deliberately left blankThis page deliberately left blankBSI is the independent national body responsible for preparing British Standardsand other standards-rel
42、ated publications, information and services. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter.British Standards Institution (BSI)raising standards worldwideBSI Group Headquarters389 Chiswick High Road London W4 4AL UKTel +44 (0)20 899
43、6 9001Fax +44 (0)20 8996 Standards are updated by amendment or revision. Users of British Stan-dards should make sure that they possess the latest amendments or editions.It is the constant aim of BSI to improve the quality of our products and serv-ices. We would be grateful if anyone finding an ina
44、ccuracy or ambiguity whileusing this British Standard would inform the Secretary of the technical com-mittee responsible, the identity of which can be found on the inside frontcover.Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001BSI offers Members an individual updating service called PLUS which e
45、nsuresthat subscribers automatically receive the latest editions of standards.Tel: +44 (0)20 8996 7669 Fax: +44 (0)20 8996 7001Email: Buying standardsYou may buy PDF and hard copy versions of standards directly using acredit card from the BSI Shop on the website addition all orders for BSI, interna
46、tional and foreign standards publicationscan be addressed to BSI Customer Services.Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001Email: In response to orders for international standards, it is BSI policy tosupply the BSI implementation of those that have been publishedas British Standards, unless
47、 otherwise requested.Information on standardsBSI provides a wide range of information on national, Europeanand international standards through its Knowledge Centre.Tel: +44 (0)20 8996 7004 Fax: +44 (0)20 8996 7005Email: Various BSI electronic information services are also available whichgive details
48、 on all its products and services. Tel: +44 (0)20 8996 7111 Fax: +44 (0)20 8996 7048Email: BSI Subscribing Members are kept up to date with standardsdevelopments and receive substantial discounts on the purchase priceof standards. For details of these and other benefits contact Membership Ad-ministration. Tel: +44 (0)20 8996 7002 Fax: +44 (0)20 8996 7001 Email: Information regarding online access to British Standards via BritishStandards Online can be found at information about BSI is available on the BSI webs
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1