1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 572-7:2012Glass in building Basic sodalime silicate glass productsPart 7: Wired or unwired channel shapedglassBS EN 572-7:2012 BRITISH STANDARDNational forewordThis British
2、 Standard is the UK implementation of EN 572-7:2012. Itsupersedes BS EN 572-7:2004 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee B/520/1, Basic and transformed glass products.A list of organizations represented on this committee can beobtained on requ
3、est to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2012. Published by BSI StandardsLimited 2012ISBN 978 0 580 76526 1ICS 81.040.20Compliance with a British St
4、andard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 July 2012.Amendments issued since publicationDate Text affectedBS EN 572-7:2012EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 572-7 Ju
5、ly 2012 ICS 81.040.20 Supersedes EN 572-7:2004English Version Glass in building - Basic soda lime silicate glass products - Part 7: Wired or unwired channel shaped glass Verre dans la construction - Produits de base: verre de silicate sodo-calcique - Partie 7: Verre profil arm ou non arm Glas im Bau
6、wesen - Basiserzeugnisse aus Kalk-Natronsilicatglas - Teil 7: Profilbauglas mit oder ohne Drahteinlage This European Standard was approved by CEN on 11 May 2012. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
7、 the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, F
8、rench, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgar
9、ia, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turk
10、ey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 5
11、72-7:2012: EBS EN 572-7:2012EN 572-7:2012 (E) 2 Contents Page Foreword 31 Scope 42 Normative references 43 Terms and definitions .44 Dimensional requirements 64.1 Method of measurement .64.1.1 Width, B, and height of flange, d 64.1.2 Length, H 64.1.3 Thickness, c 64.1.4 Flange deviation.64.1.5 Squar
12、eness of cut 74.1.6 Wire inlay 74.2 Tolerances 74.2.1 Width, B, height of flange, d, and thickness c .74.2.2 Length .74.2.3 Flange deviation.74.2.4 Squareness of cut 74.2.5 Wire inlay 75 Quality requirements .85.1 General 85.2 Methods of observation and measurement 85.2.1 Visual faults 85.2.2 Wire f
13、aults .85.3 Acceptance levels 95.3.1 Visual faults 95.3.2 Wire faults .96 Designation 9Bibliography . 10BS EN 572-7:2012EN 572-7:2012 (E) 3 Foreword This document (EN 572-7:2012) has been prepared by Technical Committee CEN/TC 129 “Glass in building”, the secretariat of which is held by NBN. This Eu
14、ropean Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2013, and conflicting national standards shall be withdrawn at the latest by January 2013. Attention is drawn to the possibility that some of the e
15、lements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 572-7:2004. This document has been prepared under a mandate given to CEN by the European Commission and the Europe
16、an Free Trade Association. This edition is a revision of EN 572-7:2004. The main change in this edition is a new method of determination of squareness. This European Standard “Glass in building Basic soda lime silicate glass products” consists of the following parts: Part 1: Definitions and general
17、physical and mechanical properties; Part 2: Float glass; Part 3: Polished wired glass; Part 4: Drawn sheet glass; Part 5: Patterned glass; Part 6: Wired patterned glass; Part 7: Wired or unwired channel shaped glass; Part 8: Supplied and final cut sizes; Part 9: Evaluation of conformity/Product stan
18、dard. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, Franc
19、e, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 572-7:2012EN 572-7:2012 (E) 4 1 Scope This European Standard specifies dime
20、nsional and minimum quality requirements (in respect of visual and wire faults) for channel shaped glass, as defined in EN 572-1:2012, for use in building. This European Standard covers channel shaped glass supplied in stock sizes and final cut sizes. 2 Normative references The following documents,
21、in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 572-1:2012, Glass in building
22、 Basic soda lime silicate glass products Part 1: Definitions and general physical and mechanical properties 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 572-1:2012 and the following apply. 3.1 patterned channel shaped glass channel shaped glass wit
23、h a pattern on the web surface Note 1 to entry: A number of different patterns are available. Note 2 to entry: Patterns might be on one or both surfaces of the web. 3.2 wired channel shaped glass channel shaped glass which has a wire inlay in the web Note 1 to entry: This means that the wire runs ac
24、ross the width, B, and in the direction of the length, H. Note 2 to entry: Additional wires might also be in the flanges. 3.3 length, H, width, B, and flange height, d defined with reference to the direction of draw of the glass ribbon as shown in Figure 1 Note 1 to entry: All corners are rounded. B
25、S EN 572-7:2012EN 572-7:2012 (E) 5 Key 1 direction of draw Figure 1 Relationship between U-channel dimensions and direction of draw 3.4 stock sizes glass delivered in the standard stock sizes: nominal length, H: supplied in multiples of 250 mm; nominal width, B: range from 232 mm to 498 mm; nominal
26、height of flange, d: either 41 mm or 60 mm Note 1 to entry: Maximum length, H, available: 7 000 mm. Note 2 to entry: Not all widths, B, are available with all flange heights, d. 3.5 visual fault fault which alters the visual quality of the glass Note 1 to entry: Visual faults include bubbles, ream,
27、scratches and inclusions and where applicable wire faults. 3.6 flange deviation deviation, z, of flange from the vertical Note 1 to entry: See Figure 2. 3.7 wire fault deviation of the wire resulting in penetration of the glass surface by the wire or break in the wire in the body of the glass 3.8 de
28、viation of the wire deviation, y, of the wire relative to a reference such as a line or straight edge Note 1 to entry: See Figure 4. BS EN 572-7:2012EN 572-7:2012 (E) 6 4 Dimensional requirements 4.1 Method of measurement 4.1.1 Width, B, and height of flange, d The width and height of flange are mea
29、sured at both cut ends of the piece using a vernier calliper with an accuracy of 0,1 mm. 4.1.2 Length, H The length is measured at the centre of the web. 4.1.3 Thickness, c The actual thickness is measured at both cut ends. Measurements, to an accuracy of 0,1 mm, are made in the centre of the web an
30、d flanges. Measurement should be made by means of an instrument of the plate gauge type with a diameter of (50 5) mm. 4.1.4 Flange deviation The deviation of the flange, z, from perpendicular to the web is determined with a right angle, as shown in Figure 2. Figure 2 Determination of flange deviatio
31、n BS EN 572-7:2012EN 572-7:2012 (E) 7 4.1.5 Squareness of cut The out of squareness of the web and flanges is determined at both cut ends. It is measured relative to a plane perpendicular to the direction of draw of the glass at the intersection of the centre line of the web and of the cut edge (see
32、 Figure 3). The deviation of the flange plane is measured. Figure 3 Determination of squareness of cut 4.1.6 Wire inlay The relationship between the width of the wire inlay, in the web, and the width, B, of the web should be obtained by measurement. The actual distance between adjacent wires should
33、be measured together with any variation in the spacing. The diameter of the wire should be measured. 4.2 Tolerances 4.2.1 Width, B, height of flange, d, and thickness c All measured values shall comply with Table 1. 4.2.2 Length The tolerance on measured length, H, is 3,0 mm. 4.2.3 Flange deviation
34、The flange deviation, z, (see Figure 2) should not exceed 1,0 mm. 4.2.4 Squareness of cut The deviation of the squareness of cut (see Figure 3) shall not exceed 3 mm. 4.2.5 Wire inlay The wire inlay shall cover at least 75 % of the web width, B. The maximum distance between adjacent wires shall not
35、exceed 35 mm. The allowable tolerance between adjacent wires is 6 mm. The diameter of the wire should be between 0,3 mm and 0,7 mm. BS EN 572-7:2012EN 572-7:2012 (E) 8 5 Quality requirements 5.1 General One quality level is considered in this European Standard. This is determined by evaluation of th
36、e visual and wire faults. 5.2 Methods of observation and measurement 5.2.1 Visual faults The piece of channel shaped glass to be examined is illuminated in conditions approximating to diffuse daylight and is observed in front of a white background. Place the glass to be examined vertically in front
37、of the screen. Arrange the point of observation 2 m from the glass, keeping the direction of observation normal to the glass surface. Note the presence of bubbles, ream, scratches and inclusions. Table 1 Tolerances on nominal width, B, height of flange, d, and thickness c Dimensions in millimetres W
38、idth, B Height of flange, d Thickness, c Nominal Tolerance Nominal Tolerance Nominal Tolerance 232 to 498 2,0 41 1,0 6 0,2 232 to 331 2,0 60 1,0 7 0,2 5.2.2 Wire faults A reference, e.g. line or straight edge, is placed parallel to the direction of the wires. The deviation, y, of the wire inlay in r
39、elation to this reference edge is measured (see Figure 4). Any penetration of the glass surface by the wire is noted. Any breaks in the wire are noted. a) Out of square b) Waviness c) BowNOTE The scale of these drawings has been exaggerated in order to be explicit about the types of deviation. Figur
40、e 4 Determination of wire deviation BS EN 572-7:2012EN 572-7:2012 (E) 9 5.3 Acceptance levels 5.3.1 Visual faults Bubbles, ream, scratches or inclusions visible in the conditions defined in 5.2 are not allowed. 5.3.2 Wire faults Acceptance levels of wire faults: a) The deviation, y, (see Figure 4) s
41、hall not exceed 5 mm per metre. b) In no case is the wire inlay allowed to penetrate the surface. c) Breaks in the wire are not acceptable. 6 Designation Wired or unwired channel shaped glasses in compliance with this European Standard shall be designated respectively by type (wired or unwired glass
42、), reference to this European Standard, tint (manufacturers reference) or clear, pattern (manufacturers reference) or not, nominal thickness in mm, nominal width, B, in mm, nominal height of flange, d, in mm, nominal length, H, in mm. EXAMPLE Wired channel shaped glass, clear, pattern reference PATT
43、ERN, thickness 6 mm, width 26,2 cm, height of flange 41 mm, length 1,50 m, intended for use in building, is designated as follows: Wired channel shaped glass - EN 572-7 - clear PATTERN, 6 mm, 262 mm, 41 mm, 1 500 mm BS EN 572-7:2012EN 572-7:2012 (E) 10 Bibliography 1 EN 572-9, Glass in building Basi
44、c soda lime silicate glass products Part 9: Evaluation of conformity/Product standard This page deliberately left blankBSI is the independent national body responsible for preparing British Standards and other standards-related publications, information and services. It presents the UK view on stand
45、ards in Europe and at the international level. BSI is incorporated by Royal Charter. British Standards and other standardisation products are published by BSI Standards Limited.British Standards Institution (BSI)raising standards worldwideBSI389 Chiswick High Road London W4 4AL UKTel +44 (0)20 8996
46、9001Fax +44 (0)20 8996 Standards and PASs are periodically updated by amendment or revision. Users of British Standards and PASs should make sure that they possess the latest amendments or editions.It is the constant aim of BSI to improve the quality of our products and services. We would be gratef
47、ul if anyone finding an inaccuracy or ambiguity while using British Standards would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside frontcover. Similary for PASs, please notify BSI Customer Services.Tel: +44 (0)20 8996 9001 Fax: +44 (0)20
48、 8996 7001BSI offers BSI Subscribing Members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of British Standards and PASs.Tel: +44 (0)20 8996 7669 Fax: +44 (0)20 8996 7001Email: Buying standardsYou may buy PDF and hard copy version
49、s of standards directly using acredit card from the BSI Shop on the website addition all orders for BSI, international and foreign standards publicationscan be addressed to BSI Customer Services.Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001Email: In response to orders for international standards, BSI will supply the British St
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有