1、BSI Standards PublicationBS EN 12016:2013Electromagnetic compatibility Product family standard forlifts, escalators and movingwalks ImmunityBS EN 12016:2013 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 12016:2013. Itsupersedes BS EN 12016:2004+A1:2008 which i
2、s withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee MHE/4, Lifts, hoists and escalators Lifts, hoists andescalators.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all th
3、e necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2013. Published by BSI StandardsLimited 2013ISBN 978 0 580 76684 8ICS 33.100.20; 91.140.90Compliance with a British Standard cannot confer immunity fromlegal obligations.This Brit
4、ish Standard was published under the authority of theStandards Policy and Strategy Committee on 31 August 2013.Amendments issued since publicationDate Text affectedBS EN 12016:2013EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 12016 August 2013 ICS 33.100.20; 91.140.90 Supersedes EN 12016:2004
5、+A1:2008English Version Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Immunity Compatibilit lectromagntique - Norme de la famille de produits ascenseurs, escaliers mcaniques et trottoirs roulants - Immunit Elektromagnetische Vertrglichkeit - Produkt
6、familien-Norm fr Aufzge, Fahrtreppen und Fahrsteige - Strfestigkeit This European Standard was approved by CEN on 22 June 2013. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard
7、 without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any o
8、ther language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republi
9、c, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN CO
10、MMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12016:2013: EBS EN 12016:2013EN 120
11、16:2013 (E) 2 Contents Page Foreword 3 Introduction .4 1 Scope 6 2 Normative references 6 3 Terms and definitions .7 4 Test procedure 10 5 Applicability of tests . 11 6 Evaluation of tests results . 11 6.1 Introduction . 11 6.2 Performance criteria . 12 6.3 Enclosure ports of safety circuits . 12 7
12、Documentation for the installer of the apparatus/assembly of apparatus . 12 Annex ZA (informative) Relationship between this European Standard and the Essential Requirements of EU Directive 2004/108/EC . 21 Annex ZB (informative) Relationship between this European Standard and the Essential Requirem
13、ents of EU Directive 2006/42/EC . 22 Annex ZC (informative) Relationship between this European Standard and the Essential Requirements of EU Directive 95/16/EC . 23 Bibliography . 24 BS EN 12016:2013EN 12016:2013 (E) 3 Foreword This document (EN 12016:2013) has been prepared by Technical Committee C
14、EN/TC 10 “Lifts, escalators and moving walks”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2014, and conflicting national standards shall be
15、 withdrawn at the latest by February 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 12016:2004+A1:2
16、008. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annexes ZA, ZB and ZC, which are an integral part of th
17、is document. The test levels and the performance criteria which are given in this European Standard reflect the fact that lifts, escalators and moving walks when in use, consist generally of self-contained apparatus (e.g. machine room, car, etc.). The related EMC product family standard for emission
18、 is: EN 12015, Electromagnetic compatibility Product family standard for lifts, escalators and moving walks Emission According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bul
19、garia, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, T
20、urkey and the United Kingdom. BS EN 12016:2013EN 12016:2013 (E) 4 Introduction This European Standard is a Type C standard as stated in EN ISO 12100. This European Standard has been prepared to provide one means of conforming to the requirements of the Electromagnetic Compatibility (EMC) Directive,
21、the Lifts Directive and the Machinery Directive. The requirements of this European Standard have been specified so as to ensure an adequate level of electromagnetic immunity for most cases. The apparatus concerned and the extent to which hazardous situations and events are covered are indicated in t
22、he scope of this document. Where the provisions of this type C standard are different from those which are stated in type A or B standards, the provisions of this type C standard take precedence over the provisions of the other standards, for apparatus that have been designed and built according to
23、the provisions of this type C standard. Test levels and immunity performance criteria are defined for: apparatus which are safety components or are used in conjunction with safety components, (safety circuits); apparatus used in general function circuits. The test levels and requirements are given o
24、n the basis that the apparatus, generally, is connected to a low voltage system. The requirements for safety circuits provide one means of demonstrating conformity with the essential health and safety requirements of the Lifts Directive and the Machinery Directive with regard to immunity against ele
25、ctromagnetic phenomena. Due to the size of an installed lift, it becomes impracticable to test the total assembly either in a test laboratory or in situ where the uncontrolled environment may also influence the test procedures and results. This applies also to measurements within the car. Similar co
26、nsiderations regarding dimensions apply equally to the testing of escalators and moving walks. Rational to the revision of the standard EN 12016:1998 a) Important changes The Scope excludes severe electromagnetic environments and apparatus already proven to be in conformity with the Electromagnetic
27、Compatibility Directive. The term “installation” has been changed to “system”. This is due to the fact that official interpretation defines that fixed installations are not covered by the conformity assessment procedures for CE marking and declaration of conformity according to the EMC Directive. Th
28、e scope of the standard is applicable to the apparatus and assembly of apparatus of lifts and escalators and assembly into systems. New requirements on radio frequency electromagnetic field above 500 MHz, these are extended to cover the digital mobile telephone services up to 1960 MHz. New requireme
29、nts for surge testing on safety circuits. New requirements on radio frequency electromagnetic field regarding safety devices as defined by the Lifts Directive and mobile telephones or radio-transmitters as a result of a risk assessment. It is assumed that BS EN 12016:2013EN 12016:2013 (E) 5 mobile t
30、elephones and radio-transmitters are not used at frequencies up to 166 MHz near safety circuits of equipment covered by the scope of this standard. Higher requirements on several environmental phenomena considering the progress on EMC technology and the results of the risk assessment. New requiremen
31、ts have been introduced for immunity to mains power supply voltage interruptions and voltage dips. b) Environmental issues Lifts, escalators and moving walks are systems whose component apparatus/assembly of apparatus are distributed (and some of which move) throughout the building. The definition i
32、n EMC terms of the use of the building (residential or industrial) cannot be predetermined or assumed to be fixed. Therefore, to cover requirements in all cases, no differentiation between environments has been made and a single set of limits has been maintained. Severe electromagnetic environments
33、have not been considered. Examples of these are: radio-transmitter stations, railways and metros, heavy industrial plant, electricity power stations. Additional tests and immunity measures may need to be taken on apparatus to be used in these environments. It is assumed that no ports connected to sa
34、fety circuit only are rated at currents greater than 100 A. Rational to the revision of the standard EN 12016:2004+A1:2008 New requirements on radio frequency electromagnetic field to cover the digital mobile telephone services and wireless communication systems up to 2 655 MHz. Performance criteria
35、 requirements for radio equipment and telecommunications terminal equipment as defined by Directive 1999/5/EC used in combined apparatus/assembly of apparatus. BS EN 12016:2013EN 12016:2013 (E) 6 1 Scope 1.1 This European Standard specifies the immunity performance criteria and test levels for appar
36、atus used in lifts, escalators and moving walks which are intended to be permanently installed in buildings including the basic safety requirements in regard to their electromagnetic environment. These levels represent essential EMC requirements. The standard refers to EM conditions as existing in r
37、esidential, office and industrial buildings. This standard addresses commonly known EMC related hazards and hazardous situations relevant to lifts, escalators and moving walks when they are used as intended and under the conditions foreseen by the lift installer or escalator and/or moving walk manuf
38、acturer. However: performance criteria and test levels for apparatus/assembly of apparatus used in general function circuits do not cover situations with an extremely low probability of occurrence; this standard does not apply to other apparatus already proven to be in conformity to the EMC Directiv
39、e, and not related to the safety of the lift, escalator or moving walk, such as lighting apparatus, communication apparatus, etc. 1.2 This European Standard does not apply to electromagnetic environments such as: radio-transmitter stations, railways and metros, heavy industrial plant, electricity po
40、wer station, which need additional investigations. 1.3 This standard is not applicable to apparatus which were manufactured before the date of its publication as EN 12016. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispe
41、nsable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 55022:2010, Information technology equipment Radio disturbance characteristics Limits and methods of measurem
42、ent (CISPR 22:2008, modified) EN 55024:2010, Information technology equipment Immunity characteristics Limits and methods of measurement (CISPR 24:2010+corrigendum Jun. 2011) EN 61000-4-2:2009, Electromagnetic Compatibility (EMC) Part 4-2: Testing and measurement techniques Electrostatic discharge i
43、mmunity test (IEC 61000-4-2:2008) BS EN 12016:2013EN 12016:2013 (E) 7 EN 61000-4-3:2006, Electromagnetic compatibility (EMC) Part 4-3: Testing and measurement techniques Radiated, radio-frequency, electromagnetic field immunity test (IEC 61000-4-3:2006)1)EN 61000-4-4:2012, Electromagnetic compatibil
44、ity (EMC) Part 4-4: Testing and measurement techniques Electrical fast transient/burst immunity test (IEC 61000-4-4:2012) EN 61000-4-5:2006, Electromagnetic compatibility (EMC) Part 4-5: Testing and measurement techniques Surge immunity test (IEC 61000-4-5:2005) EN 61000-4-6:2009, Electromagnetic co
45、mpatibility (EMC) Part 4-6: Testing and measurement techniques Immunity to conducted disturbances, induced by radio-frequency fields (IEC 61000-4-6:2008) EN 61000-4-11:2004, Electromagnetic compatibility (EMC) Part 4-11: Testing and measurement techniques Voltage dips, short interruptions and voltag
46、e variations immunity tests (IEC 61000-4-11:2004) EN 61000-6-1:2007, Electromagnetic compatibility (EMC) Part 6-1: Generic standards Immunity for residential, commercial and light-industrial environments (IEC 61000-6-1:2005) EN 61000-6-2:2005, Electromagnetic compatibility (EMC) Part 6-2: Generic st
47、andards Immunity for industrial environments (IEC 61000-6-2:2005) IEC 60050-161:1990, International Electrotechnical Vocabulary Chapter 161: Electromagnetic compatibility2)3 Terms and definitions For the purpose of this document, the terms and definitions given in EN 61000-6-1:2007, EN 61000-6-2:200
48、5, IEC 60050-161:1990 and the following apply. 3.1 assembly of apparatus arrangement of interconnected apparatus, which can be tested together Note 1 to entry: See Figure 1 and Figure 2 as examples. 3.2 apparatus assembly of components with an intrinsic function as defined by its manufacturer Note 1
49、 to entry: See Figure 1 and Figure 2 as examples. Note 2 to entry : Safety components listed by Annex IV of the Lifts Directive are considered as apparatus. 1) This document is currently impacted by EN 61000-4-3:2006/A2:2010. 2) This document is currently impacted by IEC 60050-161:1990/A1:1997 and IEC 60050-161:1990/A2:1998. BS EN 12016:2013EN 12016:2013 (E) 8 Key assembly of apparatus 1 machinery space 7 landings 2 main control / control cabinet 8 system boundary 3 machine 9 AC and/or DC power ports 4 do