1、BRITISH STANDARD BS EN 130202:1998 Harmonized system of quality assessment for electronic components Blank detail specification: Fixed tantalum capacitors with non-solid electrolyte, porous anode (sub-family 2) The European Standard EN 130202:1998 has the status of a British Standard ICS 31.060.40BS
2、EN 130202:1998 This British Standard, having been prepared under the directionof the Electrotechnical Sector Board, was published underthe authority of the Standards Board and comes intoeffect on 15 July 1998 BSI 05-1999 ISBN 0 580 30000 5 National foreword This British Standard is the English langu
3、age version of EN 130202:1998 published by the European Electronic Components Committee (CECC) of the European Committee for Electrotechnical Standardization (CENELEC). It supersedes BS CECC 30202:1988 which will be withdrawn on 1998-10-01. The UK participation in its preparation was entrusted by Te
4、chnical Committee EPL/40, Capacitors and resistors for electronic equipment, to Subcommittee EPL/40/1, Capacitors and EMI suppression components for electronic equipment, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committe
5、e any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-refer
6、ences The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catal
7、ogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comp
8、rises a front cover, an inside front cover, pages i and ii, theEN title page, pages 2 to 13 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since
9、 publication Amd. No. Date CommentsBSEN130202:1998 BSI 05-1999 i Contents Page National foreword Inside front cover Foreword 2 Text of EN 130202 5ii blankEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 130202 March 1998 Supersedes CECC 30 202:1986 and its amendments English version Blank Detail
10、 Specification: Fixed tantalum capacitors with non-solid electrolyte, porous anode (sub-family 2) Spcification particulire cadre: Condensateurs fixes au tantale lectrolyte non solide et anode poreuse (sous famille 2) Vordruck fr Baurtspezifikation: Tantal-Festkondensatoren mit flssigem Elektrolyt un
11、d Sinteranode (Unterfamilie 2) This European Standard was approved by CENELEC on 1992-01-12. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-
12、date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation und
13、er the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland,
14、Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stass
15、art 35, B-1050 Brussels 1998 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 130202:1998 EEN130202:1998 BSI 05-1999 2 Foreword At the request of CLC/TC CECC/SC 40XA (former WG 3), the text of CECC 30 202:1986, Issue 2, with its amen
16、dments A1, A3 and A5 and document CECC(Secretariat)2525, was submitted to the formal vote for conversion into a European Standard. The text of the draft, together with the voting report, circulated as document CECC(Secretariat)2997, was approved as EN130202 on 1992-01-12. The text of document CECC(S
17、ecretariat)3063, which was submitted to the formal vote and; together with the voting report, circulated as document CECC(Secretariat)3204, was approved as an amendment to EN 130202 on 1992-10-14, has been taken into account in this European Standard. The following dates were fixed: Contents Page Fo
18、reword 2 1 General data 5 1.1 Method of mounting for vibration and bump or shock tests 5 1.2 Dimensions 5 1.3 Ratings and characteristics 5 1.4 Related documents 6 1.5 Marking 6 1.6 Ordering information 6 1.7 Certified test records 6 1.8 Additional information 6 1.9 Additional or increased severitie
19、s or requirements to those specified in the generic and/or sectional specification 6 2 Inspection requirements 7 2.1 Procedures 7 Table 1 Dimensions 5 Table 2A Values of capacitance related to voltages and case sizes 5 Table 2B Characteristics at high and low temperature 6 Table 2C Impedance at kHz
20、6 Table 3 Other characteristics 7 Table 4A Lot-by-lot inspection (Group A and B) 7 Table 4B Periodic tests 9 latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 1998-10-01 latest date by which the national stand
21、ards conflicting with the EN have to be withdrawn (dow) 1998-10-01EN130202:1998 BSI 05-1999 3 Identification of the detail specification (DS) and the component The first page of the DS should have the layout recommended as follows. The numbers in square brackets correspond to the indications to be c
22、ompleted thereunder: 1 The name of the National Standards Organization under whose authority the DS is published and, if applicable, the organization from whom the DS is available. 2 The CECC symbol and the number allotted to the DS by the CECC General Secretariat. 3 The number and issue number of t
23、he CECC generic and sectional specification as relevant; also national reference if different. 4 If different from the CECC number, the national number of the DS, date of issue and any further information required by the national system, together with any amendment numbers. 5 A brief description of
24、the component or range of components. 6 Information on typical construction (where applicable). For 5 and 6 the text to be given in the DS should be suitable for an entry in the Register of Approvals CECC 00200 and CECC 00300 (Library List). 7 An outline drawing with main dimensions which are of imp
25、ortance for interchangeability, and/or reference to the appropriate national or international document for outlines. Alternatively, this drawing may be given in an annex to the DS, but 7 should always contain an illustration of the general outer appearance of the component. 8 The level(s) of quality
26、 assessment covered by the DS. 9 Reference data giving information on the most important properties of the component which allow comparison between the various component types intended for the same, or for similar, applications. Specification available from: (National Standards Organization) 1 CECC
27、number and mark 2 ELECTRONIC COMPONENTS OF ASSESSED QUALITY DETAIL SPECIFICATION IN ACCORDANCE WITH: (Number of national generic and sectional specification) 3 (National number of detail specification, dateof issue, National type number, if any) 4 Outline and dimensions: (first angle projection) 7 D
28、ETAIL SPECIFICATION FOR FIXED TANTALUM CAPACITORS WITH NON-SOLID ELECTROLYTE, POROUS ANODE (SUB-FAMILY 2) 5 TYPICAL CONSTRUCTION: Examples cylindrical/rectangular non-metallic/metallic case insulated/non-insulated axial/radial terminations Assessment level E Performance grade 8 QUICK REFERENCE DATA:
29、 Rated capacitance range, capacitance tolerance, d.c. rated voltage range, climatic category, performance grade 9 Information about manufacturers who have components qualified to this detail specification is available in the current Register of Approvals CECC 00200.4 blankEN130202:1998 BSI 05-1999 5
30、 1 General data 1.1 Method of mounting for vibration and bump or shock tests The method shall be specified in the detail specification. See 1.3.2 of EN 130200:1993. 1.2 Dimensions Table 1 Dimensions 1.3 Ratings and characteristics The following ratings and characteristics shall be specified in the D
31、S: Table 2A Values of capacitance related to voltages and case sizes Case size Dimensions mm reference 8 8 L H d NOTE 1When there is no case size reference, Table 1 may be omitted and the dimensions shall be given in Table 2, which then becomes Table 1. NOTE 2The dimensions shall be given as maximum
32、 dimensions or as nominal dimensions with a tolerance. capacitance range (See Table 2A) tolerance on rated capacitance rated voltage (See Table 2A) category voltage (if applicable) (See Table 2A) climatic category rated temperature capacitance change with temperature (See Table 2B) tangent of loss a
33、ngle (See Table 2B) leakage current (See Table 2B) impedance (if required) (See Table 2C) reverse voltage (if required) Rated voltage Category voltage a Case size Case size Case size Case size Rated capacitance (in nF and/or 4F a If different from the rated voltage.EN130202:1998 6 BSI 05-1999 Table
34、2B Characteristics at high and low temperature Table 2C Impedance at kHz (if required) 1.4 Related documents 1.5 Marking The marking of the capacitor and the packing shall be in accordance with the requirements of 1.5 of EN130200:1993. NOTEThe details of the marking of the component and packing shal
35、l be given in full in the detail specification. 1.6 Ordering information Orders for capacitors covered by this specification shall contain, in clear or in coded form, the following minimum information: a) rated capacitance; b) tolerance on rated capacitance; c) rated voltage; d) number and issue ref
36、erence of detail specification and style reference. 1.7 Certified test records Required/not required. 1.8 Additional information (Not for inspection purposes). 1.9 Additional or increased severities or requirements to those specified in the generic and/or sectional specification NOTEAdditions or inc
37、reased requirements should be specified only when essential. U R C R Capacitance change Maximum values Tan Impedance 7 Leakage current V 4F % % (100/120 Hz) 4A T A T R T B T A b 20 C T B b T A 20 C T R T B a T A: Lower category temperature T B: Upper category temperature T R: Rated temperature a Mea
38、sured with category voltage. b If applicable. Case size Impedance 7 Generic specification: EN 130000 Sectional specification: EN 130200EN130202:1998 BSI 05-1999 7 Table 3 Other characteristics 2 Inspection requirements 2.1 Procedures 2.1.1 For qualification approval the procedures shall be in accord
39、ance with 3.4 of EN 130200:1993. 2.1.2 For quality conformity inspection the test schedule (Table 4) includes sampling, periodicity, severities and requirements. The formation of inspection lots is covered by 3.5.1 of EN 130200:1993. Table 4A Lot-by-lot inspection (Group A and B) This table is to be
40、 used for defining characteristics which are additional to or tighter than those given in the sectional specification. Clause number and test a Conditions of test a IL b AQL b% Performance requirements a Group A1 Non-destructive S4 2,5 4.1 Visual examination As in 4.1 Legible marking as specified in
41、1.5 of this specification 4.1 Dimensions (gauging) As specified in Table 1 of this specification Group A2 Non-destructive II 1,0 4.2.1 Leakage current Protective resistance . 7 # . 4A, see Table 2B of this specification 4.2.2 Capacitance Frequency: kHz Bias voltage: V Within specified tolerance 4.2.
42、3 Tangent of loss angle Frequency: Hz # ., see Table 2B of this specification 4.2.4 Impedance (ifrequired) Frequency: kHz # 7, see Table 2C of this specification Group B1 Destructive c Method 1 and 2 4.5 Solderability (ifapplicable) Specify ageing if none other than 4 h 155 C dry heat Method:. S-3 2
43、,5 Good tinning as evidenced by free flowing of the solder with wetting of the terminals Method 3: 3 sEN130202:1998 8 BSI 05-1999 Table 4A Lot-by-lot inspection (Group A and B) Clause number and test a Conditions of test a IL b AQL b% Performance requirements a Group B2 S3 2,5 4.15 Characteristics a
44、t high and low temperatures d The capacitors shall be measured at each temperature step Step 1: 20 C Leakage current Capacitance Tangent of loss angle Impedance d (at same frequency as step2) For use as reference value Step 2: Lower category temperature Capacitance Tangent of loss angle d Impedance
45、d # values in Table 2B of this specification Step 3: Rated temperature Leakage current Capacitance Tangent of loss angle d Impedance d # values in Table 2B of this specification Step 4: Upper category temperature Leakage current Capacitance Tangent of loss angle d Impedance d # values in Table 2B of
46、 this specification a Refers to EN 130200:1993. b Inspection Levels (IL) and Acceptable Quality Levels (AQL) are selected from IEC 410. c Capacitors which have been submitted to the tests of subgroup B1 may be released provided they have not been submitted to ageing and are resubmitted to the tests
47、of group A and pass those tests. It is permitted to submit electrically defective capacitors or detached terminations instead of completed capacitors to this test provided they have been subjected to the same process treatments as a completed capacitor. d If required.EN130202:1998 BSI 05-1999 9 Tabl
48、e 4B Periodic tests Clause number and test a Conditions of test a p b n b c b Performance requirements a Group C1A Destructive 6 9 1 4.3.1 Initial measurement Capacitance 4.3 Robustness of terminations No visible damage No leakage of electrolyte 4.4 Resistance to soldering heat 4.4.2 Final measureme
49、nts Visual examination No visible damage No leakage of electrolyte Legible marking Group C1B Destructive 6 18 1 4.6.1 Initial measurements Capacitance 4.6 Rapid change of temperature T A= Lower category temperature T B= Upper category temperature Five cycles Exposure time t 1= 30 min Recovery: 16 h 4.6.3 Final measurements Leakage current Capacitance Tangent of loss angle