1、BRITISH STANDARD BS EN 135001:1997 Incorporating Amendments No.1 and No.2 to BSCECC35001:1978 (renumbers BS as BSEN135001:1997) Harmonized system of quality assessment for electronic components Blank detail specification: C.W. power amplifier travelling wave tubes up to500watts The European Standard
2、 EN135001:1992 has the status of a BritishStandard ICS 31.100BSEN135001:1997 BSI04-2000 ISBN 0 580 34752 4 National foreword This BritishStandard has been prepared by Technical Committee EPL/39 and is the English language version of EN113001:1991 Harmonized system of quality assessment for electroni
3、c components Blank detail specification: C.W. power amplifier travelling wave tubes up to500watts, published by the European Committee for Electrotechnical Standardization (CENELEC) Electronic Components Committee (CECC). Cross-references The BritishStandards which implement international or Europea
4、n publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary
5、provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, theENtitle pa
6、ge, pages2 to10 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date CommentsBSEN135001:1997 BSI 04-2000 i Contents Pa
7、ge National foreword Inside front cover Foreword 2 Text of EN135001 3ii blankEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 135001 May 1992 UDC: Descriptors: Quality, electronic components,travelling wave amplifier tubes English version Blank Detail Specification: C.W. power amplifier travelli
8、ng wave tubes up to500Watts Spcification Particulire Cadre: Tubes amplificateurs onde progressive(puissance de sortie jusqu500Watts) Vordruck fr Bauartspezifikation: Dauerstrich-Wanderfeldrhren frLeistungsverstrker bis500Watt This European Standard was approved by the CENELEC Electronic Components C
9、ommittee (CECC) on14 January1992. The text of this standard consists of the text of CECC35001 Issue11977 (with Amdt.1) of the corresponding CECC Specification. CENELEC members are bound to comply with CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard t
10、he status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the General Secretariat of the CECC or to any CENELEC member. This European Standard exists in three official versions (Englis
11、h, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CECC General Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austri
12、a, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland, and UnitedKingdom. The membership of the CECC is identical, with the exception of the national electrotechnical committees of Greece, Iceland and Lux
13、embourg. CECC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels 1992 Copyright reserved to CENELEC members Ref. No. EN135001:1992 EEN135001:
14、1992 BSI 04-2000 2 Foreword The CENELEC Electronic Components Committee (CECC) is composed of those member countries of the European Committee for Electrotechnical Standardization (CENELEC) who wish to take part in a harmonized System for electronic components of assessed quality. The object of the
15、System is to facilitate international trade by the harmonization of the specifications and quality assessment procedures for electronic components, and by the grant of an internationally recognized Mark, or Certificate, of Conformity. The components produced under the System are thereby accepted by
16、all the member countries without further testing. This document has been formally approved by the CECC, and has been prepared for those member countries taking part in the System who wish to issue national harmonized specifications for C.W. POWER AMPLIFIER TRAVELLING WAVE TUBES UP TO500WATTS. It sho
17、uld be read in conjunction with document CECC00100: Basic Rules (1974). At the date of printing of this document, the member countries of the CECC are Belgium, Denmark, Germany, France, Ireland, Italy, the Netherlands, Norway, Sweden, Switzerland and the UnitedKingdom, and copies of it can be obtain
18、ed from the National Committees of the CENELEC in these countries. Preface This blank detail specification was prepared by CECC Working Group13: “Microwave Tubes”. It is one of a series of blank detail specifications for travelling wave amplifier tubes, all relating to the generic specification prin
19、ted as CECC35000. In accordance with the requirements of document CECC00100, it is based, wherever possible, on the Recommendations of the International Electrotechnical Commission and in particular on IEC Publication235: Measurement of the electrical properties of microwave tubes. The text of this
20、specification was circulated to the CECC for voting in the documents below and was ratified by the CECC for printing as a CECC Specification. Contents Page Foreword 2 1 General 3 2 Identification of the harmonized detail specification 3 3 Identification of the tube 3 4 Supplementary information 5 5
21、Additional information 5 6 Data 5 Document Voting date CECC(Secretariat)267 15 Nov1974 CECC(Secretariat)267A 7 Nov1975EN135001:1992 BSI 04-2000 3 1 General This blank detail specification shows the layout and contents to be followed in the preparation of harmonized detail specifications for C.W. pow
22、er amplifier travelling wave tubes up to500watts. These requirement include the following: Identification of the harmonized detail specification Identification of the tube Supplementary information Test schedule and inspection requirements Information on application of the tube (if required) The num
23、bers between square brackets on the layout for a detail specification, as given on the next page, correspond to the indications which should be given. 2 Identification of the harmonized detail specification 3 Identification of the tube 1 The name of the National Standards Organisation under whose au
24、thority the detail specification is drafted 2 The CECC symbol and the number allotted to the national detail specification by the CECC General Secretariat 3 The number and issue number of the national generic specification 4 The national number of the detail specification, date of issue and any furt
25、her information required by the national system, together with any amendment numbers, if issued. 5 A short description of the type of tube and type number. 6 Information on typical construction (where applicable). 7 An outline drawing with main dimensions which are of importance for interchangeabili
26、ty. Alternatively, this drawing may be given in an appendix to the detail specification. 8 The application or group of applications covered by the detail specification. 9 Brief information on the most important properties of the component (extracted from6) to allow comparison between the various com
27、ponent types intended for the same, or for similar applications.EN135001:1992 4 BSI 04-2000Recommended layout for detail specifications 1 page of 2 ELECTRONIC COMPONENT OF ASSESSED QUALITY IN ACCORDANCE WITH 3 4 DETAIL SPECIFICATION for Typical Construction: 5 6 7 8 9 Seethe relevant Qualified Produ
28、cts List for the availability of components made to this specificationEN135001:1992 BSI 04-2000 5 4 Supplementary information (not for inspection purposes) Following the information given in accordance with2 and3, space shall be allocated for the following information: structurally similar features
29、of the tube which may be relevant for inspection purposes requirements for certified test records marking requirements (in accordance with2.5 of CECC35000) ordering information. 5 Additional information (not for inspection purposes) Following the information given in accordance with4, space may then
30、 be allocated for any additional information which may be of help to the user of the tube. This information may include: any requirements of a precautionary nature mounting requirements cooling requirements any special setting up or switching requirements. 6 Data (not for inspection purposes) Detail
31、 specifications shall include data on the following properties, but not necessarily in the order given. 6.1 Mechanical and environmental data: dimensioned engineering drawing mass of the tube and mass of the tube mount (if separate) mounting position and accessories precautions to be taken with resp
32、ect to external magnetic influences; ambient magnetic fields and distance from ferromagnetic materials cooling requirements maximum temperatures of specified reference points limiting values for shock and vibration (if required by the application) minimum ambient air pressure (if required by the app
33、lication) ambient temperature range, storage and operating. 6.2 Electrical Characteristics 6.3 Electrical Limiting values Absolute maximum rating system in accordance with IEC134. cathode preheating time at minimum heater voltage or current minimum value frequency range (given as x GHz to y GHz) ins
34、tantaneous bandwidth minimum value power output at stated conditions minimum value gain at stated conditions minimum value (and where appropriate maximum value) gain flatness if required by the application gain ripple gain slope AM/PM conversion coefficient AM/PM transfer coefficient intermodulation
35、 products(3tone) noise factor characteristic curve EN135001:1992 6 BSI 04-2000 heater voltage or current minimum and maximum values heater surge current maximum value heater to cathode voltage, where appropriate maximum value grid(s) voltage(s) (with respect to cathode) minimum and maximum values sl
36、ow wave structure voltage (with respect to cathode) minimum and maximum values collector(s) voltage(s) (with respect to cathode) minimum and maximum values collector(s) current(s) maximum value(s) grid(s) current(s) maximum value slow wave structure current maximum value r.f. power input maximum val
37、ue v.s.w.r. (caused by load) maximum value focus coil current (if applicable) maximum valueInspection Requirements for Quality Conformance Lot by Lot Inspection Group A Examination or Test D ND Ref. in CECC35000 Conditions of Test Limits Units IL AQL seeNote1 Min Max % Sub-group A1 Holding period24h
38、 Post holding tests: ND 100% Available power gain 4.5.5 Heater voltage V dB Grid(s) .voltage(s) adjust to obtain required collector current and minimize structure current Grid(s).voltage(s).V Slow wave structure voltage V Collector(s) voltage(s)V Collector current mA Power output Frequency W GHz Mou
39、nt (if separate) Slow wave structure current Visual inspection Sub-group A2 Major dimensions Heater current Grid(s) current(s) Grid .voltage(s) ND 4.5.4 4.4.1 4.4.2 4.5.3 4.5.4 4.5.4 As for available power gain No voltages Seedrawing on page No other voltages As for available power gain As for avail
40、able power gain mA A mA V II 1,5 Insulation of electrodes (leakage current) 4.5.15 Heater voltage Test voltage V V AEN135001:1992 BSI 04-2000 7Inspection Requirements for Quality Conformance Lot by Lot Inspection Group A Examination or Test D ND Ref. in CECC35000 Conditions of Test Limits Units IL A
41、QL Min. Max. % Sub-group A3 ND Gain flatness 4.5.6 Heater voltage V dB S4 6,5 (if required by the application) Grid voltage(s) adjust to obtain required collector current and minimize structure current Grid(s).voltage(s)V Gain ripple (if required by the application) 4.5.7 Slow wave structure voltage
42、 adjust between.V and.V for optimum performance in each band dB S4 6,5 Gain slope (if required by the application) 4.5.8 Collector(s) voltage(s).V dB S4 6,5 Power output W Frequency range to be coveredGHz toGHz Frequency band for each measurement MHz Mount (if separate) Hot input v.s.w.r. Hot or col
43、d output v.s.w.r. (as specified) 4.5.16 4.5.16 As for available power gain but with an r.f. drive level at least10dB below that required for saturation As for available power gain but with no r.f. drive. The power level used for making this measurement must be at least10dB below saturated power leve
44、l S4 S4 6,5 6,5 Group B (lot by lot) Not applicable EN135001:1992 8 BSI 04-2000Group C (periodical inspection) Examination or Test D ND Ref. in CECC35000 Conditions of Test Limits Units Sampling requirements Min. Max. n c Sub-group C1 6monthly Mismatch stability ND 4.5.10 Heater voltage V 5 1 or Sho
45、rt circuit stability or Power stability (as specified) Grid voltage(s) adjust to obtain required collector current and minimize structure current Grid(s).voltage(s).V Collector(s) voltage(s)V Collector current Mismatch condition .mA . Power at the input Power at the output W W Slow wave structure vo
46、ltage range.V to.V Mount (if separate) Noise (if applicable) ND 4.5.11 In accordance with required application 5 1 Sub-group C2 12monthly Instantaneous bandwidth Operating loss Detail dimensions Robustness of terminations (as applicable) ND ND ND See Note2 4.5.12 4.5.13 4.4.2 4.6.1 As for available
47、power gain Proportion of max gain As for available power gain but no r.f. drive Seedrawing on page Test U of IEC68-2-21 (tensile, bending, torsion, torque as applicable) MHz dB 5 5 5 5 1 1 1 1EN135001:1992 BSI 04-2000 9Group D Qualification approval only Examination or Test D ND Ref. in CECC35000 Co
48、nditions of Test Limits Units Sampling requirements Min Max n c Sub-group D1 Phase sensitivity (if required by the application) Sub-group D2 External magnetic influence (if required by the application) ND ND 4.5.14 4.6.5 As for available power gain Dynamic variation of slow wave structure voltage.V Magnetic field.Tesla Direction of field Duration of immersion. deg/V 5 5 1 1 Post magnetic influence tests: Available power gain slow wave structure current As in sub-group A1 dB mA Magnetic shielding (if required by the application) Magnetic shielding tests: Change in available po