1、BS EN14317-2:2007ICS 91.100.60NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDThermal insulationproducts for buildings In-situ thermalinsulation formed fromexfoliated vermiculite(EV) productsPart 2: Specification for the installedproductsLicensed Copy: Wang Bin,
2、 ISO/EXCHANGE CHINA STANDARDS, 16/01/2009 06:07, Uncontrolled Copy, (c) BSIThis British Standardwas published under theauthority of the StandardsPolicy and StrategyCommittee on 31 October2008 BSI 2008ISBN 978 0 580 58021 5Amendments/corrigenda issued since publicationDate CommentsBS EN 14317-2:2007N
3、ational forewordThis British Standard is the UK implementation of .The UK participation in its preparation was entrusted to TechnicalCommittee B/540, Energy performance of materials components andbuildings.A list of organizations represented on this committee can be obtained onrequest to its secreta
4、ry.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunityfrom legal obligations.Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 16/01/2009 06:07, Uncont
5、rolled Copy, (c) BSIBS EN 14317-2:2007EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 14317-2January 2007ICS 91.100.60English VersionThermal insulation products for buildings - In-situ thermalinsulation formed from exfoliated vermiculite (EV) products - Part2: Specification for the installed produ
6、ctsProduits isolants thermiques pour le btiment - Isolationthermique forme en place base de granulats lgers deVermiculite exfolie (EV) - Partie 2: Spcification desproduits mis en placeWrmedmmstoffe fr Gebude - An derVerwendungsstelle hergestellte Wrmedmmung mitProdukten aus expandiertem Vermiculit (
7、EV) - Teil 2:Spezifikation fr die eingebauten ProdukteThis European Standard was approved by CEN on 2 December 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any
8、alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by t
9、ranslationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, German
10、y, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManage
11、ment Centre: rue de Stassart, 36 B-1050 Brussels 2007 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14317-2:2007: ELicensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 16/01/2009 06:07, Uncontrolled Copy, (c) BSIBS EN 14317-2:200
12、7EN 14317-2:2007 (E) 2 Contents page Foreword3 1 Scope 4 2 Normative references 4 3 Terms, definitions, symbols, units and abbreviated terms.4 4 Requirements.5 5 In-situ measurements6 6 Installers declaration 6 Annex A (informative) Suitability of the building and the insulation product7 Bibliograph
13、y 8 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 16/01/2009 06:07, Uncontrolled Copy, (c) BSIBS EN 14317-2:2007EN 14317-2:2007 (E) 3 Foreword This document (EN 14317-2:2007) has been prepared by Technical Committee CEN/TC 88 “Thermal insulating materials and products”, the secretariat of w
14、hich is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by July 2007, and conflicting national standards shall be withdrawn at the latest by July 2007. This draft European Standard consi
15、sts of two parts. The first part, which is the harmonised part satisfying the mandate, the CPD and is the basis for the CE marking, covers the products, which are placed on the market. The second part, which is the non-harmonised part, covers the specification for the installed products. Part 1 of t
16、his European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports the essential requirements of EU Directives. For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of Part 1 of t
17、his standard. Attention is drawn to the need to take into account any complementary member state rules (e.g. installation rules) which together with this European Standard ensures the fitness for purpose of the installed product. This European Standard is one of a series for mineral wool, expanded c
18、lay, expanded perlite, exfoliated vermiculite, polyurethane/polyisocyanurate, cellulose and urea formaldehyde in-situ formed insulation products used in buildings, but this standard can be used in other areas where appropriate. According to the CEN/CENELEC Internal Regulations, the national standard
19、s organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portu
20、gal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 16/01/2009 06:07, Uncontrolled Copy, (c) BSIBS EN 14317-2:2007EN 14317-2:2007 (E) 4 1 Scope This European Standard specifies the requirements for the four types of
21、exfoliated vermiculite products Vermiculite Aggregate (EVA), Coated Vermiculite (EVC), Hydrophobic Vermiculite (EVH) and Premixed Vermiculite (EVM), containing less than 1 % organic material as defined by Annex D of EN 14317-1:2004 for in-situ insulation of roofs, ceilings, walls and floors. This Pa
22、rt 2 of the standard is a specification for the installed products. This Part 2 of this standard also specifies the checks and test procedures to be used for the declaration made by the installer of the product. This European Standard does not specify the required level of all properties to be achie
23、ved by a product to demonstrate fitness for purpose in a particular application. The required levels are to be found in regulations or non-conflicting standards. This European Standard does not include factory made insulation products of formed shapes and boards made with exfoliated vermiculite or i
24、n-situ products intended to be used for the insulation of building equipment and industrial installations. This European Standard does not specify performance requirements for airborne sound insulation and for acoustic absorption applications. 2 Normative references The following referenced document
25、s are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 823:1994, Thermal insulating products for building applications Determination o
26、f thickness EN 14317-1:2004, Thermal insulation products for buildings In-situ thermal insulation formed from exfoliated vermiculite (EV) products Part 1: Specification for bonded and loose-fill products before installation prEN ISO 9229:2005, Thermal insulation Definitions of terms (ISO/DIS 9229:20
27、05) 3 Terms, definitions, symbols, units and abbreviated terms 3.1 Terms and definitions For the purposes of this document, the terms and definitions given in prEN ISO 9229:2005 and the following apply. 3.1.1 exfoliated vermiculite insulation material which results from expanding or exfoliating a na
28、tural micaceous mineral by heating 3.1.2 loose fill insulation in-situ insulation formed by pouring the granular material into the void or cavity, without the use of a bonding material Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 16/01/2009 06:07, Uncontrolled Copy, (c) BSIBS EN 14317-2:20
29、07EN 14317-2:2007 (E) 5 3.1.3 bonded insulation in-situ insulation formed by bonding the exfoliated vermiculite to itself, or to itself and the surface of the roof or ceiling 3.1.4 specifier person responsible for the amount and thickness of the insulation and the type of product to be used in a par
30、ticular installation NOTE The specifier could be the installation contractor but is more likely to be the architect or other qualified engineer. 3.1.5 installer person, company or organization that is responsible for installing the insulation product 3.1.6 installed insulation thickness insulation t
31、hickness as installed by the installer 3.2 Symbols and units Symbols and units used in this part of the standard: diis the installed thickness of the product m dris the required thickness of the product m Dis the declared thermal conductivity W/(m x K) RDis the declared thermal resistance m2x K/W Rs
32、is the specified thermal resistance m2x K/W 4 Requirements 4.1 General The installer shall use an insulation product that complies with EN 14317-1. The installer shall inspect the building in accordance with manufacturers guidelines and national regulations, in order to determine whether it is suita
33、ble for application of the product. Guidance is given in Annex A. NOTE 1 For calculating the thermal resistance of complete building elements involving the use of these products the procedures given in EN ISO 6946 can be used. NOTE 2 EN ISO 10456 describes how the design thermal conductivity is calc
34、ulated from the declared thermal conductivity. 4.2 Thermal resistance 4.2.1 Required thickness The required thermal resistance is obtained using a suitable thickness of exfoliated vermiculite. The required thickness shall be calculated by the specifier before installation starts according to the for
35、mula: dr = RsD (1) Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 16/01/2009 06:07, Uncontrolled Copy, (c) BSIBS EN 14317-2:2007EN 14317-2:2007 (E) 6 4.2.2 Declared thermal resistance The declared thermal resistance, RD, shall be calculated from the installed thickness, di, and the correspon
36、ding declared thermal conductivity value, D, where RD= di/D.4.3 Installed insulation thickness The mean value of the installed thickness (5.1) shall not be less than the required thickness. No individual value shall be less than 80 % of the specified value. 5 In-situ measurements 5.1 Installed insul
37、ation thickness The installed insulation thickness of the insulation layer shall be measured by the installer and declared. The method of verification will vary depending on the building and the method of application. Verification shall include reference to guides or level marks placed before instal
38、lation and direct measurement after installation using a calibrated depth gauge. At least five insulation thickness measurements in different places shall be made for each 100 m2insulation area. In case of dispute, the installed insulation thickness shall be measured in accordance with EN 823:1994,
39、Annex A, pin and plate method. 5.2 Cavity width The width of a cavity shall be measured through suitable holes using a calibrated depth gauge and declared as the thickness of the insulation. At least five cavity width measurements in different places shall be made for each 100 m2insulation area. The
40、 measurements will normally be carried out by the specifier, before installation starts. NOTE The total number of measurements necessary to determine the nominal cavity width should take into account the construction of the building and possible damage to any cladding. 5.3 Cavity fill The installer
41、shall check to ensure that a cavity is full. 6 Installers declaration The specifier in conjunction with the installer shall declare to the customer that the work has been carried out in accordance with the requirements of this standard using an insulation product that complies with EN 14317-1. The i
42、nstaller shall declare at least the following information: trade name and designation code of the installed product; declared thermal resistance; required thickness; installed thickness; volume of insulation material used; date of installation. The installer shall also declare that the work has been
43、 carried out according to the specified procedure. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 16/01/2009 06:07, Uncontrolled Copy, (c) BSIBS EN 14317-2:2007EN 14317-2:2007 (E) 7 Annex A (informative) Suitability of the building and the insulation product A.1 Building The installer should
44、 ensure that the roofs, ceiling, walls and floors are structurally sound and the area is suitable to contain loose fill products or receive the bonded insulation. This assessment should take into account all aspects of the proposed installation. On ceilings and floors with a joist or beam system, th
45、e substrate should be continuous to ensure retention of loose fill insulation products. Provision should be made for attic ventilation and vapour barriers, if necessary, prior to installation of the insulation product in accordance with local building regulations and practice. Where services such as
46、 pipes pass through the construction, adequate precaution should be taken to ensure that the insulation product is retained in the area to be insulated. Roof and floor surfaces should be clean, dry and free of extraneous materials. A.2 Insulation product The installer should ensure that for: loose f
47、ill insulation the containers of the insulation product are checked to ensure the designation details agree with those given by the specifier; bonded insulation the designation details of the insulation product and any other materials required are checked to ensure they agree with the requirements o
48、f the specifier. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 16/01/2009 06:07, Uncontrolled Copy, (c) BSIBS EN 14317-2:2007EN 14317-2:2007 (E) 8 Bibliography 1 EN ISO 6946, Building components and building elements Thermal resistance and thermal transmittance Calculation method (ISO 6946:
49、1996) 2 EN ISO 10456, Building materials and products Procedures for determining declared and design thermal values (ISO 10456:1999) Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 16/01/2009 06:07, Uncontrolled Copy, (c) BSIBS EN 14317-2:2007This page has been intentionally left blankLicensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 16/01/2009 06:07, Uncontrolled Copy, (c) BSIBS EN14317-2:2007BSI GroupHeadquarters 389Chiswick High Road,London, W4 4AL, UKTel +44 (0)20 8996 9001Fax +44 (0)20 8996
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1