1、Shower enclosures Functional requirements andtest methodsBS EN 14428:2015Incorporating corrigendum March 2017BSI Standards PublicationBS EN 14428:2015 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 14428:2015. It supersedes BS EN 14428:2004+A1:2008 which is wit
2、hdrawn.The CEN Correction Notice 17 June 2016 provided a revised English language text, incorporating the following editorial corrections: In 5.2.2, b) 1), the hyphen before (23 g116 5) C has been removed. In Table ZA.2, delete 10 at the end of the last line, since there is no reference 10. In Table
3、 ZA.3, exchange the clause numbers: 7.3 shall be in one line with Factory production control and 7.2 with Determination of the product type. In ZA.2.2.3, the line below “Attachment to Declaration of Performance” of Example 1 (Page 39) should read “No. 001CPR2013-07-14” (instead of No. CPR-14228) to
4、be in line with “DECLARATION OF PERFORMANCE No. 001CPR2013-07-14”.The UK participation in its preparation was entrusted to Technical Committee B/503, Sanitary appliances.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purpor
5、t to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2017. Published by BSI Standards Limited 2017ISBN 978 0 580 97678 0ICS 91.140.70Compliance with a British Standard cannot confer immunity from legal obligatio
6、ns.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 May 2015.Amendments/corrigenda issued since publicationDate Text affected31 March 2017 Implementation of CEN correction notice 17 June 2016EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM
7、 EN 14428 May 2015 ICS 91.140.70 Supersedes EN 14428:2004+A1:2008English Version Shower enclosures - Functional requirements and test methods Parois de douche - Prescriptions fonctionnelles et mthodes dessai Duschabtrennungen - Funktionsanforderungen und Prfverfahren This European Standard was appro
8、ved by CEN on 19 March 2015. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national s
9、tandards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language an
10、d notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hunga
11、ry, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENEL
12、EC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14428:2015 EEN 14428:2015 (E) 2 Contents Page Foreword 4 1 Scope 5 2 Normative references 5 3 Terms and definitions .5 4 R
13、equirements .6 4.1 General 6 4.2 Cleanability .6 4.3 Impact resistance/shatter properties .6 4.3.1 General 6 4.3.2 Thermally toughened safety glass .6 4.3.3 Laminated safety glass .6 4.3.4 Plastics materials.6 4.4 Durability 6 4.4.1 General 6 4.4.2 Corrosion resistance .7 4.4.3 Resistance to chemica
14、ls and stains 7 4.4.4 Resistance to wet and dry cycling .7 4.4.5 Endurance 7 4.4.6 Stability .7 4.4.7 Water retention .7 4.5 Dangerous substances .7 5 Test methods 8 5.1 Impact resistance/shatter properties .8 5.1.1 General 8 5.1.2 Test specimens for curved glass .8 5.1.3 Procedure .8 5.1.4 Assessme
15、nt of fragmentation 9 5.2 Impact behaviour of plastic sheets . 13 5.2.1 Apparatus 13 5.2.2 Procedure 13 5.3 Resistance to chemicals and stains . 21 5.3.1 Reagents 21 5.3.2 Apparatus 22 5.3.3 Test specimens . 24 5.3.4 Procedure 24 5.3.5 Expression of results . 24 5.4 Resistance to wet and dry cycling
16、 24 5.4.1 Test specimens . 24 5.4.2 Procedure 24 5.4.3 Results . 25 5.5 Endurance . 25 5.6 Stability 25 5.7 Water retention 27 6 Marking 31 7 Assessment and verification of constancy of performance - AVCP . 32 7.1 General . 32 7.2 Type testing . 32 7.2.1 General . 32 BS EN 14428:2015EN 14428:2015 (E
17、)EN 14428:2015 (E) 3 7.2.2 Samples, testing and compliance criteria . 33 7.3 Factory production control. 33 7.3.1 General . 33 7.3.2 Equipment 33 7.3.3 Raw materials and components 34 7.3.4 Product testing and assessment . 34 7.3.5 Non-conforming products 34 7.3.6 Corrective action . 34 Annex ZA (in
18、formative) Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation 35 ZA.1 Scope and relevant characteristics . 35 ZA.2 Procedure for assessment and verification of constancy of performance (AVCP) of shower enclosures 35 ZA.2.1 System of AVCP 35 ZA.2.2
19、Declaration of performance (DoP) . 36 ZA.2.2.1 General 36 ZA.2.2.2 Content 36 ZA.2.2.3 Example of DoP 37 ZA.3 CE marking and labelling 41 Bibliography 43 BS EN 14428:2015EN 14428:2015 (E)EN 14428:2015 (E) 4 Foreword This document (EN 14428:2015) has been prepared by Technical Committee CEN/TC 163 “S
20、anitary appliances”, the secretariat of which is held by UNI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by November 2015, and conflicting national standards shall be withdrawn at the latest by
21、February 2017. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 14428:2004+A1:2008. This document has been
22、prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of the EU Construction Products Regulation. For relationship with EU Construction Products Regulation, see informative Annex ZA, which is an integral part of
23、this document. The main technical change is the deletion of the Impact resistance/shatter properties clause and its replacement by a reference to the new edition of EN 12150-1. The other significant change is the updating of the AVCP clause and Annex ZA to the new format. According to the CEN/CENELE
24、C Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Icel
25、and, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 14428:2015EN 14428:2015 (E)EN 14428:2015 (E) 5 1 Scope This European Standard specifies requirements for sho
26、wer enclosures for domestic purposes which ensure that the product, when installed in accordance with the manufacturers installation instructions, gives satisfactory performance when used as intended. This European Standard does not apply to shower cabinets or curtains and does not specify aesthetic
27、 and dimensional requirements. NOTE For the purposes of this document the term “domestic purposes” includes use in hotels, accommodation for students, hospitals and similar buildings, except when special medical provisions are required. 2 Normative references The following documents, in whole or in
28、part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. prEN 12150-1:2013, Glass in building Thermally
29、toughened soda lime silicate safety glass Part 1: Definition and description EN 14449, Glass in building - Laminated glass and laminated safety glass - Evaluation of conformity/Product standard EN ISO 2409, Paints and varnishes - Cross-cut test (ISO 2409:2013) EN ISO 7599, Anodizing of aluminium and
30、 its alloys - General specifications for anodic oxidation coatings on aluminium (ISO 7599:2010) EN ISO 9227, Corrosion tests in artificial atmospheres - Salt spray tests (ISO 9227:2012) EN ISO 12543-2, Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (I
31、SO 12543-2:2011) ISO 7892:1988, Vertical building elements Impact resistance tests Impact bodies and general test procedures 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 shower enclosure arrangement of panel(s) and/or door(s) (i.e full or
32、half-height access door(s) erected on or around a drained shower place, shower tray or bath in conjunction with one or more walls of the main building structure to provide a water retaining area for the purpose of showering 3.2 shower cabinet prefabricated but not necessarily preassembled unit for t
33、he purpose of showering comprising a shower tray or bath and rigid water resistant enclosing wall(s), with or without a roof and with an entry capable of being closed to provide a fully enclosed compartment BS EN 14428:2015EN 14428:2015 (E)EN 14428:2015 (E) 6 4 Requirements 4.1 General The manufactu
34、rer shall provide with each shower enclosure detailed instructions on installation and use, to include at least the following information: description of installation with special consideration of building construction and necessary tools and sealant; instructions for appropriate maintenance and car
35、e, including guidance on cleaning. 4.2 Cleanability When inspected visually, the surfaces of the components of the shower enclosures which are accessible during use and cleaning shall be free from sharp corners, edges and burrs. When using recommended cleaning agents in accordance with the manufactu
36、rers installation and care instructions, there shall be no reduction in safety or function of the shower enclosure. 4.3 Impact resistance/shatter properties 4.3.1 General Shower enclosures may be glazed with various materials. Where glass is used, this shall meet the requirements of 4.3.2 or 4.3.3 a
37、nd where plastics materials are used, they shall meet the requirements of 4.3.4. 4.3.2 Thermally toughened safety glass 4.3.2.1 Thermally toughened flat safety glass Thermally toughened safety glass shall meet the requirements of prEN 12150-1:2013. 4.3.2.2 Thermally toughened curved safety glass Tes
38、t in accordance with 5.1 to ensure that under these test conditions the glass has a particle count of 40 or greater and the length of the longest particle shall not exceed 100 mm. 4.3.3 Laminated safety glass Laminated safety glass shall conform to EN 14449 and EN ISO 12543-2. Laminated safety glass
39、 shall not have holes, for example for fixings, hinges, handles or any other fittings. NOTE Laminated safety glass is susceptible to water penetration from the edges if they are not suitably protected. 4.3.4 Plastics materials When tested in accordance with 5.2, sheets shall not break or they shall
40、break safely. 4.4 Durability 4.4.1 General Products conforming with the requirements of 4.2 and 4.3 and the following are deemed to be durable. BS EN 14428:2015EN 14428:2015 (E)EN 14428:2015 (E) 7 4.4.2 Corrosion resistance All components shall consist of corrosion-proof materials or shall be corros
41、ion-protected. All corrosion protection performances shall be evaluated with test methods specified in an appropriate European or International Standard. The standard used and the results of the test shall be recorded. Examples of minimum requirements: the minimum paint adhesion performance for powd
42、er-coated or wet-painted surfaces has a cross-cut value g148 2 when tested in accordance with EN ISO 2409; the minimum average thickness of coating on aluminium is of grade AA5 when tested in accordance with one of the methods given in EN ISO 7599. In no cases is minimum local thickness less than 80
43、 % of the minimum average thickness. Compliance with the neutral salt spray (NSS) test e.g. as specified in EN ISO 9227 corrosion test in artificial atmospheres - salt spray tests with a minimum exposure time of 200 h; The defect surface area A is less than or equal to 0,1 % (A g148 0,1 %). The defe
44、cts do not exceed a dimension of 0,3 mm. This list is not exhaustive. 4.4.3 Resistance to chemicals and stains When tested in accordance with 5.3 the glazing materials shall not show permanent staining or deterioration. 4.4.4 Resistance to wet and dry cycling When tested in accordance with 5.4, the
45、glazing materials shall not show any cracks, crazing or discoloration. Uncoated and unpainted thermally toughened safety glass is deemed to be resistant to wet and dry cycling and need not be tested. 4.4.5 Endurance When tested in accordance with 5.5, shower enclosures shall not show any functional
46、deterioration after 20 000 closing-opening cycles. 4.4.6 Stability When tested in accordance with 5.6, shower enclosures shall withstand an energy representing the impact of a human body on a large impact area (e.g. blow from shoulder, fall) without any functional deterioration which could result in
47、 injury to the user. 4.4.7 Water retention When tested in accordance with 5.7, shower enclosures shall retain water. A few small drops of water on the outside of the water retaining area are acceptable. Where shower enclosures are intended for installation in wet room environments (where watertightn
48、ess is not required), water may temporarily pass outside the water retaining area as long as it is drained to the water retaining area. 4.5 Dangerous substances National regulations on dangerous substances may require verification and declaration on release, and sometimes content, when construction
49、products covered by this standard are placed on those markets. In the absence of European harmonized test methods, verification and declaration on release/content should be done taking into account national provisions in the place of use. BS EN 14428:2015EN 14428:2015 (E)EN 14428:2015 (E) 8 NOTE An informative database covering European and national provisions on dangerous substances is available at the Construction website on EUROPA accessed through: http:/ec.europa.eu/enterprise/construction/cpd-ds/. 5 Test methods 5.1 Impact resistance/shatter p