1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 15836-1:2010Plastics Plasticized poly(vinylchloride) (PVC-P) membranesfor inground swimming poolsPart 1: Homogenous membranes ofnominal thickness equal to or greater than0,
2、75 mmBS EN 15836-1:2010 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 15836-1:2010.The UK participation in its preparation was entrusted to TechnicalCommittee PRI/82, Thermoplastic materials.A list of organizations represented on this committee can beobtained
3、on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. BSI 2010ISBN 978 0 580 63009 5ICS 83.140.10; 97.220.10Compliance with a British Standard cannot confer immunity fromlegal obligations.
4、This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 August 2010Amendments issued since publicationDate Text affectedBS EN 15836-1:2010EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15836-1 June 2010 ICS 83.140.10 English Version Plastics
5、- Plasticized poly(vinyl chloride) (PVC-P) membranes for inground swimming pools - Part 1: Homogenous membranes of nominal thickness equal to or greater than 0,75 mm Plastiques - Membranes en poly(chlorure de vinyle) plastifi (PVC-P) pour piscines enterres - Partie 1: Membranes homognes dpaisseur no
6、minale suprieure ou gale 0,75 mm Kunststoffe - Kunststoffbahnen aus weichmacherhaltigem Polyvinylchlorid (PVC-P) fr erdverlegte Schwimmbder - Teil 1: Homogene Bahnen mit einer Nenndicke von mindestens 0,75 mm This European Standard was approved by CEN on 19 May 2010. CEN members are bound to comply
7、with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management
8、 Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the of
9、ficial versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, S
10、lovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2010 CEN All rights of exploitation in any form and by any means reserved worldw
11、ide for CEN national Members. Ref. No. EN 15836-1:2010: EBS EN 15836-1:2010EN 15836-1:2010 (E) 2 Contents Page Foreword 31 Scope 42 Normative references 43 Terms, definitions, symbols and abbreviations .53.1 Terms and definitions .53.2 Symbols 53.3 Abbreviations .54 Sampling and conditioning .64.1 S
12、ampling .64.2 Conditioning of test pieces .65 PVC-P compound.65.1 Characteristics of the compound.65.2 Heavy metals and other dangerous substances 65.3 Environmental aspects .66 Visual characteristics 76.1 Appearance 76.2 Colour (plain coloured membranes) 76.3 Abrasion resistance (printed and/or coa
13、ted membranes) .77 Physico-chemical characteristic 88 Dimensional characteristics .89 Mechanical characteristics .910 Characteristics for durability 911 Storage conditions . 1012 Installation, refurbishment, exploitation and maintenance 1013 Designation and marking . 1113.1 Designation . 1113.2 Mark
14、ing 11Annex A (normative) Determination of the contents of CaCO3, heavy metals and other elements 12Annex B (normative) Assessment of chlorine resistance . 13B.1 Principle . 13B.2 Test liquid 13B.3 Apparatus 13B.4 Test pieces 13B.5 Procedure 13B.6 Test report . 14Annex C (normative) Assessment of th
15、e resistance to staining agents 15C.1 Principle . 15C.2 Staining agents . 15C.3 Apparatus 15C.4 Test specimens . 15C.5 Procedure 15C.6 Expression of results . 16C.7 Test report . 16Bibliography . 17BS EN 15836-1:2010EN 15836-1:2010 (E) 3 Foreword This document (EN 15836-1:2010) has been prepared by
16、Technical Committee CEN/TC 249 “Plastics”, the secretariat of which is held by NBN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by December 2010, and conflicting national standards shall be withd
17、rawn at the latest by December 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. EN 15836, Plastics Plasticized poly(vinyl chlorid
18、e) (PVC-P) membranes for inground swimming pools, consists of the following parts: Part 1: Homogenous membranes of nominal thickness equal to or greater than 0,75 mm this standard Part 2: Reinforced membranes of nominal thickness equal to or greater than 1,5 mm According to the CEN/CENELEC Internal
19、Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg
20、, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 15836-1:2010EN 15836-1:2010 (E) 4 1 Scope This European Standard specifies the visual, dimensional, mechanical and durability characteristics of plasticized poly(viny
21、l chloride) (PVC-P) homogenous membranes of nominal thickness greater than or equal to 0,75 mm for use as liners for inground swimming pools. It also specifies the characteristics of the composition of the PVC-P used to produce the membranes. It applies specifically to homogenous membranes intended
22、for use in swimming pools where the water temperature is less than or equal to 28 C. If the membrane manufacturer permits a temperature of water continuously maintained above 28 C, this document also applies. 2 Normative references The following referenced documents are indispensable for the applica
23、tion of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 438-2:2005, High-pressure decorative laminates (HPL) Sheets based on thermosetting resins (usually called Laminate
24、s) Part 2: Determination of properties EN 495-5, Flexible sheets for waterproofing Determination of foldability at low temperature Part 5: Plastic and rubber sheets for roof waterproofing EN 1107-2, Flexible sheets for waterproofing Determination of dimensional stability Part 2: Plastic and rubber s
25、heets for roof waterproofing EN 1848-2, Flexible sheets for waterproofing Determination of length, width, straightness and flatness Part 2: Plastic and rubber sheets for roof waterproofing EN 1849-2, Flexible sheets for waterproofing Determination of thickness and mass per unit area Part 2: Plastic
26、and rubber sheets EN 1850-2, Flexible sheets for waterproofing Determination of visible defects Part 2: Plastic and rubber sheets for roof waterproofing EN 12310-2, Flexible sheets for waterproofing Determination of resistance to tearing Part 2: Plastic and rubber sheets for roof waterproofing EN 12
27、316-2, Flexible sheets for waterproofing Determination of peel resistance of joints Part 2: Plastic and rubber sheets for roof waterproofing EN 12317-2, Flexible sheets for waterproofing Determination of shear resistance of joints Part 2: Plastic and rubber sheets for roof waterproofing EN 20105-A02
28、, Textiles Tests for colour fastness Part A02: Grey scale for assessing change in colour (ISO 105-A02:1993) EN ISO 62:2008, Plastics Determination of water absorption (ISO 62:2008) EN ISO 175:2000, Plastics Methods of test for the determination of the effects of immersion in liquid chemicals (ISO 17
29、5:1999) EN ISO 291, Plastics Standard atmospheres for conditioning and testing (ISO 291:2008) EN ISO 527-1, Plastics Determination of tensile properties Part 1: General principles (ISO 527-1:1993 including Corr 1:1994) BS EN 15836-1:2010EN 15836-1:2010 (E) 5 EN ISO 527-3, Plastics Determination of t
30、ensile properties Part 3: Test conditions for films and sheets (ISO 527-3:1995) EN ISO 846:1997, Plastics Evaluation of the action of microorganisms (ISO 846:1997) EN ISO 1183-1, Plastics Methods for determining the density of non-cellular plastics Part 1: Immersion method, liquid pyknometer method
31、and titration method (ISO 1183-1:2004) EN ISO 4892-2:2006, Plastics Methods of exposure to laboratory light sources Part 2: Xenon-arc lamps (ISO 4892-2:2006) EN ISO 5470-1:1999, Rubber- or plastics-coated fabrics Determination of abrasion resistance Part 1: Taber abrader (ISO 5470-1:1999) 3 Terms, d
32、efinitions, symbols and abbreviations 3.1 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1.1 homogenous membrane sheet made of calendered or extruded, waterproof and gas-pervious, plasticized poly(vinyl chloride) (PVC-P), packaged in rolls, for
33、use in the manufacture of swimming pool liners 3.1.2 liner removable independent pocket, factory-made from waterproof, flexible, expandable, plasticized poly(vinyl chloride) (PVC-P) membranes NOTE The liner contributes to the leaktightness of a swimming pool in the same way as the parts to be sealed
34、 and the pipework. 3.1.3 inground swimming pool permanent installation containing treated water for water activities totally or partially realized under the ground level with a water depth 0,85 m or a water volume 8 m33.2 Symbols Enthickness of the membrane declared by the manufacturer, in millimetr
35、es lnwidth declared by the manufacturer, in metres or millimetres Lnlength of the roll declared by the manufacturer, in metres nmass density declared by the manufacturer, in grams per cubic centimetre 3.3 Abbreviations CaCO3calcium carbonate PVC-P plasticized poly(vinyl chloride) BS EN 15836-1:2010E
36、N 15836-1:2010 (E) 6 4 Sampling and conditioning 4.1 Sampling The test pieces shall be taken only from rolls of unused membranes. 4.2 Conditioning of test pieces Unless otherwise specified by the applicable test method, the test pieces used for the determination of the characteristics shall be condi
37、tioned before testing for at least 4 h in standard atmosphere 23/50 (23 2) C, (50 10) % HR according to EN ISO 291:2008. 5 PVC-P compound 5.1 Characteristics of the compound When tested in accordance with the test methods as specified in Table 1 using the parameters indicated, the PVC-P compound sha
38、ll have characteristics conforming to the requirements given in Table 1. Table 1 Characteristics of the compound Characteristic Requirement Test parameters Test method Density (n 0,02) g/cm3 n: density as declared by the manufacturer Test temperature 23 C EN ISO 1183-1 Water absorption 1 % mass Dura
39、tion of immersion Test temperature 168 h (23 2) C EN ISO 62:2008, Method 1 CaCO3content 3 % mass Annex A5.2 Heavy metals and other dangerous substances The PVC-P membranes should conform to all national and international regulations in force. The PVC-P membranes shall consist of materials that are n
40、ot substances classified as carcinogen category 1 or carcinogen category 2, mutagen category 1 or mutagen category 2, toxic to reproduction category 1 or toxic to reproduction category 2 (see Directive 76/769/EEC 1). The total concentration of lead (Pb), cadmium (Cd), mercury (Hg), hexavalent chromi
41、um Cr(VI) and arsenic (As) shall not exceed 100 mg/kg. NOTE This requirement is based on the concentration levels of heavy metals present in packaging as defined in Directive 94/62/EC, Article 11 2. For the determination of the total concentration of Pb, Cd, Hg, Cr(VI) and As, the method given in An
42、nex A shall be used. 5.3 Environmental aspects The PVC-P compounds are recyclable materials that can be treated in a material recovery process intended to save resources while minimising harmful emissions into air, water and soil as well as their impacts on human health. BS EN 15836-1:2010EN 15836-1
43、:2010 (E) 7 NOTE A scheme for the characterisation of plastics waste is given in EN 15347 3 and data for the characterisation of PVC recyclates are given in EN 15346 4. 6 Visual characteristics 6.1 Appearance Visible defects in the membrane shall be determined using the method specified in EN 1850-2
44、. A visual inspection shall be made on a minimum area of the PVC-P membrane that is 2 m long and as wide as the membrane itself. The inspection shall be performed on samples of both sides of the membrane taken at random from a roll laid down, without tension, on a flat, opaque surface. The membrane
45、shall have no defects visible to the naked eye, such as bubbles, blisters, coloured streaks, pinholes, mottles, folds or ripples. However air inclusion and mottles cannot be completely avoided in PVC-P sheet. The appearance shall be uniform, as even as that of the reference test piece, irrespective
46、of the area examined. The surface condition (smooth or embossed) and the colour reflection shall be in conformance with those of the reference test piece. Non-printed membranes shall have an even surface finish. In the case of a printed membrane, the imprint shall be even with no smudging. No ink sh
47、all be transferred to the non-printed side. An embossed membrane shall have a regular appearance with an even pattern. The pigments shall be homogeneously and evenly distributed throughout the material. Slight differences in colour, related to composition and manufacture shall generally be permissib
48、le. The rolls of membranes shall be suitably and sufficiently tight. The result of the visual examination shall be expressed as “appearance conform“ or “appearance non-conform“. In the latter case, the defects noted shall be listed. 6.2 Colour (plain coloured membranes) The colour of the unused (new
49、) membrane, as delivered, shall be the same as that of the reference sample as agreed between the supplier and the customer. The contrast or visual differences between the unused membrane and the reference sample shall be assessed in accordance with EN 20105-A02. NOTE The trichromatic coordinates L*, a* and b* determined according to ISO 7724-1 5, ISO 7724-2 6 and