1、BSI Standards PublicationAlarm systems Intrusion and hold-up systemsPart 2-7-3: Intrusion detectors Glass break detectors (active)BS EN 50131-2-7-3:2012Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELECNot for ResaleNo reproduction or network
2、ing permitted without license from IHS-,-,-National forewordThis British Standard is the UK implementation of EN 50131-2-7-3:2012. Itsupersedes DD CLC/TS 50131-2-7-3:2009 which is withdrawn.Some of the test methods contained within this standard have been foundto be incorrectly specified. The workin
3、g group responsible for the standardhave developed revised tests and an amendment to the standard has beenproposed by CENELEC and is anticipated.The UK committee recommends that this be taken into account whenusing this standard.The UK participation in its preparation was entrusted by TechnicalCommi
4、ttee GW/1, Electronic security systems, to Subcommittee GW/1/1,Alarm components.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its corre
5、ct application. The British Standards Institution 2013Published by BSI Standards Limited 2013ISBN 978 0 580 78413 2ICS 13.320Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Com
6、mittee on 31 October 2013.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 50131-2-7-3:2012Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELECNot for ResaleNo reproduction or networking permitted without lice
7、nse from IHS-,-,-EUROPEAN STANDARD EN 50131-2-7-3 NORME EUROPENNE EUROPISCHE NORM September 2012 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1
8、000 Brussels 2012 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50131-2-7-3:2012 E ICS 13.320 Supersedes CLC/TS 50131-2-7-3:2009English version Alarm systems - Intrusion and hold-up systems - Part 2-7-3: Intrusion detectors - Gl
9、ass break detectors (active) Systmes dalarme - Systmes dalarme contre lintrusion et les hold-up - Partie 2-7-3: Dtecteurs dintrusion - Dtecteurs bris de glace (actifs) Alarmanlagen - Einbruch- und berfallmeldeanlagen - Teil 2-7-3: Einbruchmelder - Glasbruchmelder (Aktiv) This European Standard was a
10、pproved by CENELEC on 2012-08-13. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such n
11、ational standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into it
12、s own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Maced
13、onia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 50131-2-7-3:2012Copyright European Committee for Electrotech
14、nical Standardization Provided by IHS under license with CENELECNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-EN 50131-2-7-3:2012 - 2 - Contents Foreword . 51 Scope . 62 Normative references . 63 Terms, definitions and abbreviations 63.1 Terms and definitions. 63
15、.2 Abbreviations . 74 Functional Requirements 74.1 Event Processing . 74.2 Operational requirements 94.2.1 Time interval between intrusion signals or messages . 94.2.2 Switch on delay 94.2.3 Self tests 94.3 Detection 94.3.1 Detection performance 94.3.2 Indication of detection 104.4 Immunity to false
16、 alarm sources 104.4.1 General 104.4.2 Immunity to Small objects hitting the glass104.4.3 Immunity to Soft objects hitting the glass 104.4.4 Immunity to Hard objects hitting the glass .104.4.5 Immunity to Static pressure .104.4.6 Immunity to Dynamic pressure 114.4.7 Immunity to wide band noise .114.
17、5 Tamper security .114.5.1 Resistance to and detection of unauthorised access to the inside of the detector through covers and existing holes .114.5.2 Detection of removal from the mounting surface .114.5.3 Detection of masking .114.5.4 Immunity to magnetic field interference .124.6 Electrical requi
18、rements 124.6.1 General 12BS EN 50131-2-7-3:2012Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELECNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- 3 - EN 50131-2-7-3:2012 4.6.2 Detector current consumption .
19、124.6.3 Slow input voltage rise and voltage range limits .124.6.4 Input voltage ripple 124.6.5 Input voltage step change .124.7 Environmental classification and conditions 124.7.1 Environmental classification 124.7.2 Immunity to environmental conditions .135 Marking, identification and documentation
20、 .135.1 Marking and/or identification 135.2 Documentation .136 Testing .136.1 General 136.2 General test conditions 136.2.1 Standard laboratory conditions for testing .136.2.2 General detection testing environment and procedures 146.3 Basic Detection Test 146.3.1 General 146.3.2 Basic Test Source 14
21、6.3.3 Basic Detection Test Method .146.4 Performance tests 156.4.1 General 156.4.2 Verification of detection performance 156.4.3 Hole drilling with a diamond hole saw .166.4.4 Glass cutting 166.5 Switch-on delay, time interval between signals, and indication of detection .176.6 Fault condition signa
22、ls or messages: self tests .176.7 Tests of immunity to false alarm sources 186.7.1 General 186.7.2 Immunity to Small objects hitting the glass186.7.3 Immunity to Soft objects hitting the glass 186.7.4 Immunity to Hard objects hitting the glass .196.7.5 Immunity to Static pressure .196.7.6 Immunity t
23、o Dynamic pressure 20BS EN 50131-2-7-3:2012Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELECNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-EN 50131-2-7-3:2012 - 4 - 6.7.7 Immunity to wide band noise based
24、using Flat steel rulers .206.7.8 Immunity to wide band noise based using ICs .216.8 Tamper security .216.8.1 Prevention of unauthorised access to the inside of the detector through covers and existing holes .216.8.2 Detection of removal from the mounting surface .216.8.3 Resistance to magnetic field
25、 interference226.8.4 Detection of masking .226.9 Electrical tests 226.9.1 General 226.9.2 Detector current consumption .226.9.3 Slow input voltage change and input voltage range limits .226.9.4 Input voltage ripple 236.9.5 Input voltage step change .236.9.6 Total loss of power supply .236.10 Environ
26、mental classification and conditions 246.11 Marking, identification and documentation 256.11.1 Marking and/or identification 256.11.2 Documentation 25Annex A (normative) Catalogue of standard glass types .26Annex B (informative) List of small tools suitable for testing immunity of casing to attack 2
27、7Annex C (normative) Dimensions b) Any disallowed field adjustable control settings or combinations of these; c) Where alignment adjustments are provided, these shall be labelled as to their function; d) The manufacturers quoted nominal operating voltage and the maximum and quiescent current consump
28、tion at that voltage; e) The detection range (minimum and maximum) and coverage diagram. The installation instructions shall be clear and concise that the maximum range will include the farthest point from the sensor input to any point of the monitored glass; f) All types, maximum size, minimum and
29、maximum thickness of glass for which the detector is claimed to detect; g) Any restrictions according to the mounting location of the detector, or any other restrictions which apply to the performance of the detector; h) Any specific settings needed to meet the requirements of this document at the c
30、laimed grade. 6 Testing 6.1 General The tests are intended to be primarily concerned with verifying the correct operation of the detector to the specification provided by the manufacturer. All the test parameters specified shall carry a general tolerance of 10 % unless otherwise stated. A list of te
31、sts appears as a general test matrix in Annex I. 6.2 General test conditions 6.2.1 Standard laboratory conditions for testing The general atmospheric conditions in the measurement and tests laboratory shall be those specified in EN 60068-1:1994, 5.3.1, unless stated otherwise. BS EN 50131-2-7-3:2012
32、Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELECNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-EN 50131-2-7-3:2012 - 14 - Temperature 15 C to 35 C Relative humidity 25 % RH to 75 % RH Air pressure 86 kPa
33、to 106 kPa 6.2.2 General detection testing environment and procedures Manufacturers documented instructions regarding mounting and operation shall be read and applied to all tests. 6.2.2.1 Testing environment The detectors or sensor elements will be mounted according to the manufacturers description
34、 on the monitored object (glass window or door glass pane). Some tests will be performed on the monitored object, others will be performed on panes (unframed window), where the detectors are mounted directly on. 6.2.2.2 Test procedures The tests will be performed with the types of glass claimed by t
35、he manufacturer. These tests will be performed with the sizes and thicknesses of glass as specified in Annex A. Additionally, tests will be performed with the maximum size claimed by the manufacturer if this is greater than the maximum size specified in Annex A. Additional test will be performed wit
36、h the thinnest glass claimed by the manufacturer, if this is thinner than the minimum thickness specified in Annex A. The detector shall be connected to the nominal supply voltage and connected to the monitoring system that is appropriate to the test. The detector shall be allowed to stabilise for 1
37、80 s. The intrusion signal or message output shall be monitored. If multiple sensitivity modes are available, any non-compliant modes shall be identified by the manufacturer. All compliant modes shall be tested. 6.3 Basic Detection Test 6.3.1 General The purpose of the Basic Detection Test is to ver
38、ify that a detector is still operational after a test or tests has/have been carried out. The Basic Detection Test verifies only the qualitative performance of the detector. The Basic Detection Test is performed using the BTS. 6.3.2 Basic Test Source For functional verification there shall be a devi
39、ce available which will simulate a glass breakage or destruction, without breaking the glass (BTS), alternatively a pane of standard sized glass (see Annex A) can be broken to verify the detection. The Basic Test Source (BTS) which is specified by the manufacturer simulates the breaking of a standar
40、d glass window by the low energy attack test. This device should be a test device, which is specified for testing through simulation of a glass break from or recommended by the manufacturer. This device should simulate a glass breakage or destruction, by pressing the device onto the monitored glass
41、and simulating a sound, frequency or condition, which needs to be detected. 6.3.3 Basic Detection Test Method The detector shall generate an intrusion signal or message when a test device (BTS) is used to simulate a glass breakage. The test will be performed according to the manufacturers instructio
42、ns after the first installation, to verify, that all detectors are installed properly. It will be performed again, BS EN 50131-2-7-3:2012Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELECNot for ResaleNo reproduction or networking permitted w
43、ithout license from IHS-,-,- 15 - EN 50131-2-7-3:2012 after or / and during the environmental tests under the same conditions the tests had been performed the first time, to verify that the detectors will still function the way, the manufacturer claims to support (e.g. detection range) and to compar
44、e this results with the results of the initial test. If the test is not compatible with the detector, use the manufacturers information to generate the correct algorithm. The detector(s) shall produce an intrusion signal or message when exposed to an alarm stimulus both before and after being subjec
45、ted to any test that may adversely affect its performance. 6.4 Performance tests 6.4.1 General The general test conditions of 6.2.2 shall apply to all tests in this series. Detection performance shall be tested against the manufacturers documented claims. Any variable controls shall be set to the va
46、lues recommended by the manufacturer to achieve the claimed performance. The detectors shall be assessed in the specified test environment. 6.4.2 Verification of detection performance 6.4.2.1 General All performance tests are based on physical destruction characteristics (e.g. the sound of breakage)
47、 of the size, thickness and types of glass claimed to be supported by the manufacturer including the standard glass types listed in Annex A, if claimed to be supported by the manufacturer. 6.4.2.2 Sensitivity performance test The test will be performed for each glass type claimed to be supported by
48、the manufacturer. Each glass pane will be positioned on top of the support / distance pieces, to ensure that the glass break signal can reach the detectors undampened. Three sender and receiver pairs (or combined sensor elements) shall be mounted according to the manufacturers installation instructions on the monito