1、 g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58in optical fibre communication systems Product specifications Part 8-5: LSH-PC simplex terminated o
2、n IEC 60793-2-50 category B1.1 and B1.3 singlemode fibre, composite ferrule category UThe European Standard EN 50377-8-5:2007 has the status of a British StandardICS 33.180.20Connector sets and interconnect components to be used BRITISH STANDARDBS EN 50377-8-5:2007BS EN 50377-8-5:2007This British St
3、andard was published under the authority of the Standards Policy and Strategy Committee on 28 September 2007 BSI 2007ISBN 978 0 580 57565 5Amendments issued since publicationAmd. No. Date Commentscontract. Users are responsible for its correct application.Compliance with a British Standard cannot co
4、nfer immunity from legal obligations.National forewordThis British Standard is the UK implementation of EN 50377-8-5:2007.The UK participation in its preparation was entrusted by Technical Committee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnecting devices and passive compo
5、nents.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a EUROPEAN STANDARD EN 50377-8-5 NORME EUROPENNE EUROPISCHE NORM August 2007 CENELEC European Committee for Electrotech
6、nical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN
7、 50377-8-5:2007 E ICS 33.180.20 English version Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 8-5: LSH-PC simplex terminated on IEC 60793-2-50 category B1.1 and B1.3 singlemode fibre, composite ferrule category U Jeux de
8、connecteurs et composants dinterconnexion utiliser dans les systmes de communication par fibres optiques - Spcifications de produit - Partie 8-5: Type LSH-PC simplex cbl sur une fibre unimodale des catgories B1.1 et B1.3 de la CEI 60793-2-50, frule composite, catgorie U Steckverbinderstze und Verbin
9、dungsbauelemente fr Lichtwellenleiter-Datenbertragungssysteme - Produktnormen - Teil 8-5: Bauart LSH-PC-Simplex zum Anschluss an Einmodenfasern der Typen B1.1 und B1.3 nach IEC 60793-2-50 mit Komposit-Stift fr die Kategorie U This European Standard was approved by CENELEC on 2007-03-01. CENELEC memb
10、ers are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on applicati
11、on to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat h
12、as the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherl
13、ands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 50377-8-5:2007 - 2 - Foreword This European Standard was prepared by the Technical Committee CENELEC TC 86BXA, Fibre optic interconnect, passive and connectorised components. The text o
14、f the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as EN 50377-8-5 on 2007-03-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2008-03
15、-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2010-03-01 _ - 3 - EN 50377-8-5:2007 Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications Part 8-5: LSH-PC simplex terminated on IEC 607
16、93-2-50 category B1.1 and B1.3 singlemode fibre, composite ferrule category U Description Performance Coupling mechanism: Latched push-pull Configuration: Plug/adaptor/plug Fibre category: EN 60793-2-50 Types B1.1 and B1.3 Cable type: See Table 3 Application: Attenuation grades: (random mate) Return
17、 loss grades: For use in category U (uncontrolled environment) B: 0,12 dB mean 0,25 dB for 97 % of measurements C: 0,25 dB mean 0,50 dB for 97 % of measurements 2: 45 dB Related documents: EN 60794-2 Optical fibre cables - Part 2: Indoor cables - Sectional specification (IEC 60794-2) EN 61300 series
18、 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures (IEC 61300 series) EN 61753-1 Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards (IEC 61753-1) EN 61754-15 Fibre o
19、ptic connector interfaces - Part 15: Type LSH connector family (IEC 61754-15) EN 61755-1 Fibre optic connector optical interfaces - Part 1: Optical interfaces for single mode non-dispersion shifted fibres - General and guidance (IEC 61755-1) EN 61755-3-6 Fibre optic connector optical interfaces - Pa
20、rt 3-6: Optical interface - 2,5 mm and 1,25 mm diameter cylindrical 8 degrees angled-PC composite ferrule using Cu-Ni-alloy as fibre surrounding material, single mode fibre (IEC 61755-3-6) ETSI TS 100 671 Transmission and Multiplexing (TM); Passive optical components; Optical fibre connectors for si
21、ngle-mode optical fibre communication systems; Common requirements and conformance testing Outline and maximum dimensions: EN 50377-8-5:2007 - 4 - Contents 1 Scope .5 1.1 Product definition 5 1.2 Intermateability5 1.3 Operating environment5 1.4 Reliability.5 1.5 Quality assurance.5 2 Normative refer
22、ences6 3 Description .7 3.1 Plug.7 3.2 Adaptor.7 3.3 Materials.7 3.4 Dimensions 7 3.5 Colour and marking .7 4 Variants 8 4.1 Terminated plug.8 4.2 Adaptor.9 5 Dimensional requirements10 5.1 Outline dimensions10 5.2 Mating face and other limit dimensions .14 6 Tests 23 6.1 Sample size 23 6.2 Test and
23、 measurement methods 23 6.3 Test sequence.23 6.4 Pass/fail criteria23 7 Test report23 8 Testing requirements 24 8.1 Dimensional and marking requirements .24 8.2 Optical performance requirements24 8.3 Mechanical performance requirements.26 8.4 Environmental performance requirements31 Annex A (normati
24、ve) Adaptor matched reference plug details34 Annex B (informative) Reference connector details 35 Annex C (normative) Sample size and product sourcing requirements36 Bibliography.37 Figure 1 - Outline dimensions - Plug .10 Figure 2 - Outline dimensions - Adaptor11 Figure 3 - Mating face and other li
25、mit dimensions - Plug.14 Figure 4 - Ferrule end face geometry - After termination16 Figure 5 - Positioning of fibre core.17 Figure 6 - Ferrule end face geometry - Allowable undercut18 Figure 7 - Requirements for the attenuation grades for the plug fibre core connected to the ideal reference.19 Figur
26、e 8 - Mating face and other dimensions - Adaptor20 Figure 9 - Pin gauge for adaptor .22 Table 1 - Ensured level of random attenuation5 Table 2 - Preferred colour scheme7 Table 3 - Plug variants 8 Table 4 - Adaptor variants.9 Table 5 - Geometrical parameters.17 Table 6 - Optical performance requireme
27、nts24 Table 7 - Mechanical performance requirements 26 - 5 - EN 50377-8-5:2007 1 Scope 1.1 Product definition This European Standard contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements which a terminated and assembled singlemode resilient a
28、lignment sleeve LSH-PC simplex connector set (plug/adaptor/plug), adaptor and patchcord must meet in order for it to be categorised as an EN standard product. Since different variants and grades of performance are permitted, product marking details are given in 3.5. 1.2 Intermateability Although all
29、 products conforming to the requirements of this standard will intermate, the resulting level of random attenuation performance will only be ensured in accordance with Table 1. The intention is that this will be true irrespective of the manufacturing source(s) of the product. When intermating plug v
30、ariants having different attenuation grades, the resulting level of attenuation can not be assured to be any better than the worst attenuation grade. The intermating of a grade C plug with a grade B plug will result in an uncertain level of random attenuation performance. Table 1 - Ensured level of
31、random attenuation Plug variant/Attenuation grade C B C C C B C B 1.3 Operating environment The tests selected combined with the severities and durations are representative of a category U environment as defined in EN 61753-1. 1.4 Reliability Whilst the anticipated service life expectancy of the pro
32、duct in this environment is 20 years, compliance with this standard does not guarantee the reliability of the product. This should be predicted using a recognised reliability assessment programme. 1.5 Quality assurance Compliance with this standard does not guarantee the manufacturing consistency of
33、 the product. This should be maintained using a recognised quality assurance programme. EN 50377-8-5:2007 - 6 - 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated referenc
34、es, the latest edition of the referenced document (including any amendments) applies. EN 60793-2-50 Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres (IEC 60793-2-50) EN 61300-2-1 Fibre optic interconnecting devices and passive components - B
35、asic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) (IEC 61300-2-1) EN 61300-2-2 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-2: Tests - Mating durability (IEC 61300-2-2) EN 61300-2-4 Fibre optic interconnecti
36、ng devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention (IEC 61300-2-4) EN 61300-2-5 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion/twist (IEC 61300-2-5) EN 613
37、00-2-6 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-6: Tests - Tensile strength of coupling mechanism (IEC 61300-2-6) EN 61300-2-7 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part
38、2-7: Tests - Bending moment (IEC 61300-2-7) EN 61300-2-12 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-12: Tests - Impact (IEC 61300-2-12) EN 61300-2-17 Fibre optic interconnecting devices and passive components - Basic test and measurem
39、ent procedures - Part 2-17: Tests - Cold (IEC 61300-2-17) EN 61300-2-18 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests - Dry heat - High temperature endurance (IEC 61300-2-18) EN 61300-2-22 Fibre optic interconnecting devices and
40、 passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature (IEC 61300-2-22) EN 61300-2-26 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-26: Tests - Salt mist (IEC 61300-2-26) EN 61300-2-42 Fibre
41、 optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-42: Tests - Static side load for connectors (IEC 61300-2-42) EN 61300-2-44 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-44: Tests - Fl
42、exing of the strain relief of fibre optic devices (IEC 61300-2-44) EN 61300-2-46 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-46: Tests - Damp heat cyclic (IEC 61300-2-46) EN 61300-3-4 Fibre optic interconnecting devices and passive comp
43、onents - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation (IEC 61300-3-4) EN 61300-3-6 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss (IEC 61300-3-
44、6) EN 61300-3-10 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-10: Examinations and measurements - Gauge retention force (IEC 61300-3-10) EN 61300-3-15 Fibre optic interconnecting devices and passive components - Basic test and measuremen
45、t procedures - Part 3-15: Examinations and measurements - Eccentricity of a convex polished ferrule endface (IEC 61300-3-15) EN 61300-3-16 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-16: Examinations and measurements - Endface radius of
46、 spherically polished ferrules (IEC 61300-3-16) EN 61300-3-23 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-23: Examinations and measurements - Fibre position relative to ferrule endface (IEC 61300-3-23) - 7 - EN 50377-8-5:2007 3 Descript
47、ion The LSH-PC connector is a single position plug connector set of plug/adaptor/plug configuration characterised by a cylindrical, spring loaded butting ferrule of 2,5 mm nominal diameter and a latched push-pull coupling mechanism. The optical alignment mechanism of the connectors is of a resilient
48、 sleeve style. 3.1 Plug The plug features a cylindrical composite ferrule using Cu-Ni-alloy as fibre surrounding material and a push-pull mechanism. It has a single male key which is used to limit and may be used to orientate, the relative rotation between mated connectors. The plug has mechanical a
49、nd colour coding. Alternative materials may be used for the ferrule that have directly compatible material properties to the specified materials but the end face and performance requirements must be met under all conditions. 3.2 Adaptor The adaptor has a zirconia ceramic resilient alignment sleeve. The mounting style can be: i square flange - 2 hole fixing; ii square flange - side clip fixing ; iii square flange - top bottom clip fixing. Covers (dust caps) shall be provided to protect each port of the adapt