1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 50411-3-6:2013Fibre organisers and closures to be used in optical fibre communication systems Product specificationsPart 3-6: Multimode mechanical fibre splice for use in a
2、n outdoor protected environment (Cat U)BS EN 50411-3-6:2013 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 50411-3-6:2013.The UK participation in its preparation was entrusted to TechnicalCommittee GEL/86/2, Fibre optic interconnecting devices and passivecompon
3、ents.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2013.Published by BSI Stan
4、dards Limited 2013 ISBN 978 0 580 74168 5 ICS 33.180.20 Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 March 2013. Amendments issued since publicationDate T e
5、x t a f f e c t e dBS EN 50411-3-6:2013EUROPEAN STANDARD EN 50411-3-6 NORME EUROPENNE EUROPISCHE NORM March 2013 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue
6、Marnix 17, B - 1000 Brussels 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50411-3-6:2013 E ICS 33.180.20 English version Fibre organisers and closures to be used in optical fibre communication systems - Product specificati
7、ons - Part 3-6: Multimode mechanical fibre splice for use in an outdoor protected environment (Cat U) Organiseurs et botiers de fibres destins tre utiliss dans les systmes de communication par fibres optiques - Spcifications de produits - Partie 3-6: Epissure mcanique de fibres multimodales installe
8、 en environnement extrieur protg (Cat U) LWL-Spleikassetten und -Muffen fr die Anwendung in LWL Kommunikationssystemen - Produktnorm - Teil 3-6: Mechanische Spleie von Mehrmoden-Faser fr geschtzte Freiluftanwendungen (Kategorie U) This European Standard was approved by CENELEC on 2012-12-24. CENELEC
9、 members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on appl
10、ication to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CE
11、NELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, I
12、celand, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 50411-3-6:2013EN 50411-3-6:2013 2 Contents Foreword 3 1 Scope . 5 1.1 Product definition . 5 1.2 Inte
13、roperability . 5 1.3 Expected performance . 5 1.4 Operating environment . 5 1.5 Reliability . 5 1.6 Quality assurance 5 2 Normative references 5 3 Description 6 3.1 General 6 3.2 Mechanical splice 7 3.3 Materials 7 3.4 Dimensions 7 3.5 Colour and marking 7 4 Variants . 8 5 Dimensional requirements 8
14、 6 Tests 9 6.1 Introduction 9 6.2 Test sample preparation 9 6.3 Test and measurement methods 9 6.4 Pass/fail criteria . 9 7 Test report . 9 8 Performance requirements . 9 8.1 Dimensional and marking requirements 9 8.2 Assembly yield requirement . 9 8.3 Optical performance requirements . 10 Annex A (
15、normative) Fibre type 16 Annex B (normative) Sample size and product sourcing requirements 17 Figures Figure 1 Outline and maximum dimensions. 8 Tables Table 1 Optical fibre mechanical splice, for category U variants 8 Table 2 Test details and requirements 10 Table A.1 Fibre type characteristics 16
16、Table B.1 Sample size per test . 17 BS EN 50411-3-6:2013 3 EN 50411-3-6:2013 Foreword This document (EN 50411-3-6:2013) has been prepared by CLC/TC 86BXA “Fibre optic interconnect, passive and connectorised components“. The following dates are fixed: latest date by which this document has to be impl
17、emented at national level by publication of an identical national standard or by endorsement (dop) 2013-12-24 latest date by which the national standards conflicting with this document have to be withdrawn (dow) 2015-12-24 Attention is drawn to the possibility that some of the elements of this docum
18、ent may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. BS EN 50411-3-6:2013EN 50411-3-6:2013 4 Fibre organisers and closures to be used in optical fibre communication systems Product specifications Part 3-6: Multimode
19、mechanical fibre splice for use in an outdoor protected environment (Cat U) Description Performance Type: Fibre splice Application: EN 61753-1, Category U with extension of lower temperature to -40 C Style: Mechanical Operating wavelength: 850 nm and 1 300 nm Attenuation grades 0,25 dB maximum (97 %
20、) Fibre category EN 60793-2-10 type A1a.1, A1a.2, A1a.3 and A1b Return loss grades 20 dB Related documents: EN 60793-2-10 Optical fibres Part 2-10: Product specifications Sectional specification for category A1 multimode fibres (IEC 60793-2-10) EN 60794-2-50 Optical fibre cables Part 2-50: Indoor ca
21、bles Family specification for simplex and duplex cables for use in terminated cable assemblies (IEC 60794-2-50) EN 61300 series Fibre optic interconnecting devices and passive components Basic test and measurement procedures (IEC 61300 series) EN 61753-1 Fibre optic interconnecting devices and passi
22、ve components performance standard Part 1: General and guidance for performance standards (IEC 61753-1) Outline and maximum dimensions: Variant Dimension W mm Dimension H mm Dimension L mm Type M1 3,8 6,4 38 Type M2 4,0 4,0 36 Type M3 3,2 3,2 45 Type M4 4,2 4,2 44 Type M5 4,0 4,0 40 Type M6 5,0 65 B
23、S EN 50411-3-6:2013 5 EN 50411-3-6:2013 1 Scope 1.1 Product definition This European Standard contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements which a multimode mechanical splicewill meet in order for it to be categorised as an EN standa
24、rd product. Since different variants and grades of performance are permitted, product marking and identification details are given in 3.5. Although in this document the product is qualified for EN 60793-2-10 type A1a.1, A1a.2, A1a.3 and A1b multimode fibres, it may also be suitable for other fibre t
25、ypes. 1.2 Interoperability The installed mechanical splice fits into a fibre management system with optical fibre splice cassettes or splice trays. This European Standard specifies the following two physical interface dimensions: cross sectional profile with width, height or diameter (in millimetres
26、); length (in millimetres). 1.3 Expected performance In this document, the performance of a mechanical splice is given with identical fibres only. Losses associated with fibre cladding diameter and mode field mismatch are not taken into account. The measured attenuation is a function of the core con
27、centricity, cladding non-circularity and alignment capability. The optical return loss performance is a function of the index matching gel and the fibre end face preparation. 1.4 Operating environment The tests selected combined with the severities and durations are representative of an outdoor encl
28、osed environment defined as category U in EN 61753-1. To ensure that the product can be used in closures, boxes or street cabinet for categories A, G and S (as defined EN 61753-1) the specified lower temperature is extended to -40 C and requirements for temporary flooding have been added. 1.5 Reliab
29、ility Whilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with this specification does not guarantee the reliability of the product. This should be predicted using a recognised reliability assessment programme. 1.6 Quality assurance Compliance wi
30、th this specification does not guarantee the manufacturing consistency of the product. This should be maintained using a recognised quality assurance programme. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for
31、its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 60793-2-10, Optical fibres Part 2-10: Product specifications Sectional specification for category A1 multimode fibres (I
32、EC 60793-2-10) EN 61753-1, Fibre optic interconnecting devices and passive components performance standard Part 1: General and guidance for performance standards (IEC 61753-1) EN 61300-2-1, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-1: Tes
33、ts Vibration (sinusoidal) (IEC 61300-2-1) BS EN 50411-3-6:2013EN 50411-3-6:2013 6 EN 61300-2-4, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-4: Tests Fibre/cable retention (IEC 61300-2-4) EN 61300-2-5, Fibre optic interconnecting devices and
34、 passive components Basic test and measurement procedures Part 2-5: Tests Torsion/twist (IEC 61300-2-5) EN 61300-2-7, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-7: Tests Bending moment (IEC 61300-2-7) EN 61300-2-9, Fibre optic interconnect
35、ing devices and passive components Basic test and measurement procedures Part 2-9: Tests Shock (IEC 61300-2-9) EN 61300-2-17, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-18: Tests Cold (IEC 61300-2-17) EN 61300-2-18, Fibre optic interconnec
36、ting devices and passive components Basic test and measurement procedures Part 2-18: Tests Dry heat High temperature endurance (IEC 61300-2-18) EN 61300-2-22, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-22: Tests Change of temperature (IEC
37、61300-2-22) EN 61300-2-26, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-26: Tests Salt mist (IEC 61300-2-26) EN 61300-2-27, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-27: Tests Dus
38、t Laminar flow (IEC 61300-2-27) EN 61300-2-33, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-33: Tests Assembly and disassembly of closures (IEC 61300-2-33) EN 61300-2-45, Fibre optic interconnecting devices and passive components Basic test
39、and measurement procedures Part 2-45: Tests Durability test by water immersion (IEC 61300-2-45) EN 61300-2-46, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-46: Tests Damp heat cyclic (IEC 61300-2-46) EN 61300-3-3, Fibre optic interconnecting
40、 devices and passive components Basic test and measurement procedures Part 3-3: Examinations and measurements Active monitoring of changes in attenuation and return loss (IEC 61300-3-3) EN 61300-3-4, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Par
41、t 3-4: Examinations and measurements Attenuation (IEC 61300-3-4) EN 61300-3-6, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-6: Examinations and measurements Return loss (IEC 61300-3-6) EN 61300-3-28, Fibre optic interconnecting devices and p
42、assive components Basic test and measurement procedures Part 3-28: Examinations and measurements Transient loss (IEC 61300-3-28) 3 Description 3.1 General A multimode mechanical fibre splice is a passive optical interconnection component which provides optical and mechanical continuity between two o
43、ptical fibres. The products described in this specification are based on mechanical alignment of two cleaved fibres. The fibres are protected against ingress of dust or water by a sealing material, generally an index matching gel, to both minimise reflections and to improve attenuation at the glass/
44、gel/glass interface. BS EN 50411-3-6:2013 7 EN 50411-3-6:2013 Some splices may have a limited reinstallation capability. In this case the re-installability shall be clearly stated and the re-installation test 9 in 8.3 shall be conducted. 3.2 Mechanical splice An optical fibre mechanical splice body
45、contains the following pre-assembled elements: null an alignment device; null a sealing and index matching gel inside; null a fibre alignment activation device like a spring, wedge or plunger; null a fibre clamping or fixing able to withstand axial fibre loads. Mechanical splices designed for use wi
46、th cables shall contain strain relief fixing. 3.3 Materials Materials which are not specified or which are not specifically described are left to the discretion of the manufacturer. However, the following requirements shall be met. null All materials that are likely to come in contact with personnel
47、 shall meet appropriate health and safety regulations. null The sealing and index matching materials shall be compatible with the materials of the fibres and the mechanical splice parts. null All components of the splice shall be resistant to solvents and degreasing agents that are typically used to
48、 clean and degrease fibres and cables. null Metallic parts shall be resistant to the corrosive influences they may encounter during the lifetime of the product. null Exterior polymer materials shall be resistant to mould growth. 3.4 Dimensions Outline dimensions are specified. All other dimensions a
49、re left to the discretion of the manufacturer. 3.5 Colour and marking Marking of the product or packaging shall be in the following order of precedence: a) identification of manufacturer; b) manufacturing date code: year/week; c) manufacturers part number; d) variant identification number. There is no preferred colour specified. BS EN 50411-3-6:2013EN 50411-3-6:2013 8 4 Variants Table