1、BSI Standards PublicationBS EN 50615:2015Household and similarelectrical appliances SafetyParticular requirements for devices for fireprevention and suppression for electric hobs(cooktops)BS EN 50615:2015 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 50615:201
2、5. The UK participation in its preparation was entrusted to TechnicalCommittee CPL/61/7, Safety of electrical appliances - Heated appliance group.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the nec
3、essary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2015.Published by BSI Standards Limited 2015ISBN 978 0 580 83160 7 ICS 97.040.20 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standar
4、d was published under the authority of the Standards Policy and Strategy Committee on 31 March 2015.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS EN 50615:2015EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 50615 March 2015 ICS 97.040.20 English Version Household
5、and similar electrical appliances - Safety - Particular requirements for devices for fire prevention and suppression for electric hobs (cooktops) Essais sur les dispositifs de prvention et dextinction du feu pour les plaques de cuisson (tables de cuisson) Prfungen fr Vorrichtungen zur Feuervermeidun
6、g und Feuerlschung auf Kochmulden This European Standard was approved by CENELEC on 2015-01-05. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-
7、to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by tr
8、anslation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic
9、, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. Euro
10、pean Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwid
11、e for CENELEC Members. Ref. No. EN 50615:2015 E BS EN 50615:2015EN 50615:2015 - 2 - Contents Foreword 4 Introduction 5 1 Scope . 6 2 Normative references. 6 3 Terms and definitions 6 4 General requirement 7 5 General conditions for the tests . 7 6 Classification 7 7 Marking and instructions 7 8 Prot
12、ection against access to live parts 8 9 Starting of motor-operated appliances 8 10 Power input and current 8 11 Heating . 8 12 Void 14 13 Leakage current and electric strength at operating temperature 14 14 Transient overvoltages 14 15 Moisture resistance 15 16 Leakage current and electric strength
13、. 15 17 Overload protection ot transformers and associated circuits . 15 18 Endurance . 15 19 Abnormal operation 15 20 Stability and mechanical hazards . 15 21 Mechanical strength . 15 22 Construction . 15 23 Internal wiring . 17 24 Components 17 25 Supply connection and external flexible cords . 17
14、 26 Terminals for external conductors . 17 BS EN 50615:2015- 3 - EN 50615:2015 27 Provision for earthing 17 28 Screws and connections . 17 29 Clearances, creepage distances and solid insulation 17 30 Resistance to heat and fire 17 31 Resistance to rusting . 18 32 Radiation, toxicity and similar haza
15、rds 18 BS EN 50615:2015EN 50615:2015 - 4 - Foreword This document (EN 50615:2015) has been prepared by CLC/TC 61 “Safety of household and similar electrical appliances“. The following dates are fixed: latest date by which this document has to be implemented at national level by publication of an ide
16、ntical national standard or by endorsement (dop) 2016-01-05 latest date by which the national standards conflicting with this document have to be withdrawn (dow) 2018-01-05 This document is intended to be used in conjunction with EN 60335-1:2012 and its amendments. Attention is drawn to the possibil
17、ity that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment Designed for Use within Ce
18、rtain Voltage Limits (LVD - 2006/95/EC). BS EN 50615:2015- 5 - EN 50615:2015 Introduction This European Standard has been prepared to provide a means of conforming to essential safety requirements of the Low Voltage Directive 2006/95/EC. Other requirements and other EU Directives may be applicable t
19、o the devices within the scope of this standard. This European Standard is a product family standard dealing with the safety of devices for fire prevention and suppression for hobs (cooktops). This European Standard recognizes the level of protection against fire hazards of stationary cooking ranges
20、, hobs and similar appliances. A device for fire prevention and suppression for hobs (cooktops) that complies with the text of this standard will not necessarily be considered to comply with the safety principles of the standard if, when examined and tested, it is found to have other features that i
21、mpair the level of safety covered by these requirements. This European Standard takes into account the requirements of the HD 384 Series as far as possible so that there is compatibility with the wiring rules when the device is connected to the supply mains. However, national wiring rules may differ
22、. This European Standard applies in conjunction with EN 60335-1:2012 and its amendments, which is referred to in this text as “Part 1”. This European Standard supplements or modifies the corresponding clauses of Part 1 as indicated in the text. Although from evidences available the main cause of pro
23、blems is fire, also production of dangerous amount of smoke or just smoke, that contains dangerous substances, was considered, but during the development of the standard it was not possible to develop a reproducible test for such detection. This subject is therefore under consideration. BS EN 50615:
24、2015EN 50615:2015 - 6 - 1 Scope The first sentence in the Scope of EN 60335-1 is replaced by: This European standard deals with the safety of electric devices used for detection, prevention and suppression of fire originated: from a cooking process, or from flammable material left on the hob. NOTE T
25、he provisions of this document, duly adapted to the specific installation and conditions of use, may be taken into consideration as guidance also for the protection from fire originated from the use of portable cooking appliances or from grills in the oven cavity. The devices covered by this Europea
26、n Standard may operate by interaction with, or integration of, other devices such as smoke detectors, fire detectors, motion detectors, CO detectors and fire extinguishers that are covered by their specific applicable standards. 2 Normative references The following documents, in whole or in part, ar
27、e normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 54-3:2001, Fire detection and fire alarm systems Par
28、t 3: Fire alarm devices Sounders EN 60335-1:2012, Household and similar electrical appliances Safety Part 1: General requirements (IEC 60335-1:2010, modified) EN 60335-2-6:2003, Household and similar electrical appliances Safety Part 2-6: Particular requirements for stationary cooking ranges, hobs,
29、ovens and similar appliances (IEC 60335-2-6:2000, modified) EN 60335-2-31:2003, Household and similar electrical appliances Safety Part 2-31: Particular requirements for range hoods and other cooking fume extractors (IEC 60335-2-31:2002) 3 Terms and definitions For the purposes of this document, the
30、 terms and definitions given in EN 60335-1:2012, EN 60335-2-6:2003 and the following apply. 3.1.9 Replacement The appliance is connected to the supply mains and operated as in normal use. Vessels, without lids, containing water are placed on each hob element. The diameter of the vessel is approximat
31、ely equal to that of the hob element. Hob elements are operated to maintain simmering. 3.101 Categories of fire protection devices 3.101.1 Category A BS EN 50615:2015- 7 - EN 50615:2015 Device for extinguishing and simultaneous power cut-off of the appliance. 3.101.2 Category B Device for preventive
32、 power cut-off of the appliance. 3.101.3 Category AB Device for preventive power cut-off of the appliance, followed by extinguishing, if flame occurs. 4 General requirement This clause of Part 1 is applicable. 5 General conditions for the tests This clause of Part 1 is applicable except as follows.
33、Addition: The tests shall be carried out in a test room having a volume between 20 m and 30 m. For the tests of 11.104.1 and 11.104.2, devices that only depend on ambient temperature for their operation shall be tested at an ambient temperature of 4005+C. Verification of the type of operation shall
34、be done by examination of the technical documentation delivered by the manufacturer. 6 Classification This clause of part 1 is applicable except as follows: 6.101 With reference to the type of intervention the devices shall be of one of the following categories: Category A, Category B, Category AB C
35、ompliance is checked by inspection and by the relevant tests. 7 Marking and instructions This clause of Part 1 is applicable except as follows. 7.1 Addition: Devices shall be marked with the reference to their category. 7.12 Addition: Instructions shall give information to the user with regard to th
36、e meaning/function of the marked category. In case the device is suitable only for given types of cooking appliances or for hobs with a maximum width this shall be stated in the instructions. BS EN 50615:2015EN 50615:2015 - 8 - Devices for fire prevention, detection and suppression will not detect a
37、ll possible hazards due to different cooking habits. Whenever relevant, the details on the interval for technical check and maintenance done by the manufacturer of the device or his authorized representatives shall be stated. Specific instructions for user maintenance (e.g. cleaning of the detection
38、 device, periodical verification of functionality, etc.) shall be given. For Category B devices: this device may not be suitable for fires originating from flammable materials left in proximity of the hob or on the hob For Category A devices: this device is not suitable to control fires originating
39、in an oven or in an oven grill. 7.12.1 Addition: Instructions shall state the specific installation conditions and, if relevant, the limitations of use (e.g. in case when no range hood is foreseen in the installation or in case of cooking appliances not installed against the walls of the kitchen or
40、the reference to the specific products for which the device is designed). 8 Protection against access to live parts This clause of Part 1 is applicable. 9 Starting of motor-operated appliances This clause of Part 1 is not applicable. 10 Power input and current This clause of Part 1 is applicable. 11
41、 Heating This clause of Part 1 is applicable except as follows. 11.1 Addition Compliance is checked with the tests in 11.104. 11.2 Addition: The devices shall be installed according to the instructions given by the manufacturer. If the instruction manual provides multiple ways or positions for insta
42、llation of the device(s) the device(s) shall be installed in the most unfavourable position. Based on the specific instructions given by the manufacturer, a hob having six hob elements as defined in EN 60335-2-31:2003, 11.2, is installed in a base cabinet having the following dimensions: BS EN 50615
43、:2015- 9 - EN 50615:2015 Width: 119,8 2 cm, Depth: 60,0 2 cm, Height: 86,0 cm 2 cm. One cabinet with dimensions Width: 59,8 cm 2 cm, Depth: 60,0 cm 2 cm, Height: 86,0 cm 2 cm is installed on both sides of the base cabinet supporting the hob. In case the manufacturer limits the use of the device to a
44、 hob having four elements, the hob as defined in EN 60335-2-31:2003, 11.2, is installed in a base cabinet having the following dimensions Width: 59,8 cm 2 cm, Depth: 60,0 cm 2 cm, Height: 86,0 cm 2 cm If the instructions for use foresee the use of a range hood, a cabinet with dimensions Width: 59,8
45、cm 2 cm, Depth: 37,0 cm 2 cm, Height: 70,0 cm 2 cm is installed on both sides of the range hood. If the device is foreseen to be installed with hobs with less than 4 or more than 6 hob elements, the hob indicated by the manufacturer of the device shall be used, choosing the one giving the most unfav
46、ourable results. The tests can also be performed with the suitable hobs specified in the instructions by the manufacturer choosing the one giving the most unfavourable results. If no specification is available in the instructions, then the hobs required by EN 60335-2-31 shall be used. If devices of
47、Category A, or Category B or Category AB are integrated in the range hood or in the hob, the range hood or the hob are subjected to the tests as delivered. In case of devices foreseen to be integrated or mounted on a specific model of range hood, the range hood foreseen by the manufacturer of the de
48、vice is installed in a cabinet having suitable dimensions. The test shall be carried out with the range hood operating on both conditions: switched-off and switched on at maximum air flow. The bottom level of the cabinets shall be at 55 cm 2 cm from the top of the base cabinet supporting the hob. A
49、typical installation for a 4 hob elements is given in Figure 101 Figure 101 Addition During this test there shall be no activation of the alarm. Add the following new sub clauses: BS EN 50615:2015EN 50615:2015 - 10 - 11.101 Verification of correct operation of devices for fire detection and suppression The device shall take measures to ensure that, as a result of unattended operation or excessive temperature, fires caused by the cooking process are avoided. For category A and AB devices, in addition, the risk of dangerou