1、BSI Standards PublicationSpecifications for particular types of winding wiresPart 53: Aromatic polyamide (aramid) tape wrapped rectangular copper wire, temperature index 220BS EN 60317-53:2014National forewordThis British Standard is the UK implementation of EN 60317-53:2014. It isidentical to IEC 6
2、0317-53:2014. It supersedes BS EN 60317-53:1999 which iswithdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee L/-/99, Winding wires.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to in
3、clude all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2014.Published by BSI Standards Limited 2014ISBN 978 0 580 81658 1ICS 29.060.10Compliance with a British Standard cannot confer immunity fromlegal obligations.This Br
4、itish Standard was published under the authority of theStandards Policy and Strategy Committee on 31 July 2014.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 60317-53:2014EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 60317-53 July 2014 ICS 29.060.10 Supe
5、rsedes EN 60317-53:1999 English Version Specifications for particular types of winding wires - Part 53: Aromatic polyamide (aramid) tape wrapped rectangular copper wire, temperature index 220 (IEC 60317-53:2014) Spcifications pour types particuliers de fils de bobinage - Partie 53: Fil de section re
6、ctangulaire en cuivre envelopp avec un ruban polyamide aromatique (aramide), dindice de temprature 220 (CEI 60317-53:2014) Technische Lieferbedingungen fr bestimmte Typen von Wickeldrhten - Teil 53: Flachdrhte aus Kupfer, umwickelt mit Band aus aromatischen Polyamiden, Temperaturindex 220 (IEC 60317
7、-53:2014) This European Standard was approved by CENELEC on 2014-05-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and biblio
8、graphical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the resp
9、onsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finl
10、and, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Elect
11、rotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. R
12、ef. No. EN 60317-53:2014 E BS EN 60317-53:2014EN 60317-53:2014 - 2 - Foreword The text of document 55/1396/CDV, future edition 2 of IEC 60317-53, prepared by IEC/TC 55 “Winding wires“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60317-53:2014. The following dates are
13、fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2015-02-01 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2017-05-01 This document supersede
14、s EN 60317-53:1999. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 6031
15、7-53:2014 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60264 Series NOTE Harmonized as EN 60264 Series (not modified). IEC 60317 Series NOTE Harmonized as EN 6
16、0317 Series (not modified). BS EN 60317-53:2014- 3 - EN 60317-53:2014 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable
17、 for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant E
18、N/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here: www.cenelec.eu. Publication Year Title EN/HD Year IEC 60172 - Test procedure for the determination of the temperature index of enamelled and tape wrapped winding wires
19、 FprEN 60172 - IEC 60819-3-3 2011 Non-cellulosic papers for electrical purposes - Part 3: Specifications for individual materials - Sheet 3: Unfilled aramid (aromatic polyamide) papers EN 60819-3-3 2011 IEC 60851 series Methods of test for winding wires HD 490.1 S1 series BS EN 60317-53:2014 2 IEC 6
20、0317-53:2014 IEC 2014 CONTENTS INTRODUCTION . 6 1 Scope 7 2 Normative references . 7 3 Terms, definitions, general notes and appearance 7 3.1 Terms and definitions 7 3.2 General notes . 8 3.2.1 Methods of test 8 3.2.2 Winding wire 8 3.3 Appearance . 9 4 Dimensions 9 4.1 Conductor dimensions . 9 4.2
21、Tolerance on conductor dimensions 11 4.3 Rounding of corners 11 4.4 Increase in dimensions due to tape covering 11 4.5 Maximum overall dimensions . 12 5 Electrical resistance . 12 6 Elongation . 13 7 Springiness 13 8 Flexibility and adherence 13 9 Heat shock 13 10 Cut-through . 13 11 Resistance to a
22、brasion . 13 12 Resistance to solvents . 13 13 Breakdown voltage. 13 14 Continuity of insulation . 13 15 Temperature index . 14 16 Resistance to refrigerants 14 17 Solderability . 14 18 Heat or solvent bonding . 14 19 Dielectric dissipation factor 14 20 Resistance to hydrolysis and to transformer oi
23、l . 14 21 Loss of mass . 14 23 Pin hole test . 14 30 Packaging 14 Annex A (informative) Example of tape wrapped wire 16 Bibliography 17 Figure A.1 Illustrations of overlap . 16 Table 1 Nominal cross-sectional areas of preferred sizes 10 Table 2 Conductor tolerances . 11 BS EN 60317-53:2014IEC 60317-
24、53:2014 IEC 2014 3 Table 3 Corner radii . 11 Table 4 Elongation requirements 13 BS EN 60317-53:2014 6 IEC 60317-53:2014 IEC 2014 INTRODUCTION This part of IEC 60317 is one of a series which deals with insulated wires used for windings in electrical equipment. The series has three groups describing:
25、1) Winding wires Test methods (IEC 60851); 2) Specifications for particular types of winding wires (IEC 60317); 3) Packaging of winding wires (IEC 60264). BS EN 60317-53:2014IEC 60317-53:2014 IEC 2014 7 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES Part 53: Aromatic polyamide (aramid) tape wr
26、apped rectangular copper wire, temperature index 220 1 Scope This part of IEC 60317 specifies requirements for tape wrapped rectangular copper winding wire of temperature index 220. The insulation consists of one or more wrappings of aromatic polyamide (aramid) tape of various thicknesses. NOTE The
27、heat shock test is inappropriate for this type of wire, and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified. The range of nominal conductor dimensions covered by this standa
28、rd is: width: min. 2,00 mm max. 16,00 mm; thickness: min. 0,80 mm max. 5,60 mm. The specified combinations of width and thickness as well as the specified ratio width/thick-ness are given in Table 1. 2 Normative references The following documents, in whole or in part, are normatively referenced in t
29、his document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60172, Test procedure for the determination of the temperature index of enamelle
30、d winding wires IEC 60819-3-3:2011, Non-cellulosic papers for electrical purposes Part 3: Specifications for individual materials Sheet 3: Unfilled aramid (aromatic polyamide) papers IEC 60851 (all parts), Winding wires Test methods 3 Terms, definitions, general notes and appearance 3.1 Terms and de
31、finitions For the purpose of this document, the following terms and definitions apply. 3.1.1 class thermal performance of a wire expressed by the temperature index and the heat shock temperature BS EN 60317-53:2014 8 IEC 60317-53:2014 IEC 2014 3.1.2 conductor bare metal after removal of the insulati
32、on 3.1.3 covering material which is wound, wrapped or braided around a bare or insulated conductor 3.1.4 insulation coating or covering on the conductor with the specific function of withstanding voltage 3.1.5 winding wire wire used for winding a coil to provide a magnetic field 3.1.6 wire conductor
33、 coated or covered with an insulation 3.2 General notes 3.2.1 Methods of test All methods of test used in this part of IEC 60317 are given in IEC 60851. The clause numbers used in this standard are identical to the corresponding test numbers in the IEC 60851 series of standards. In case of inconsist
34、encies between the publication on methods of test and this standard, IEC 60317-53 shall prevail. Where no specific range of nominal conductor dimensions is given for a test, the test applies to all nominal conductor dimensions covered by the specification sheet. Unless otherwise specified, all tests
35、 shall be carried out at a temperature from 15 C to 35 C and a relative humidity from 45 % to 75 %. Before measurements are made, the specimens shall be preconditioned under these atmospheric conditions for a time sufficient to allow the specimens to reach stability. The wire to be tested shall be r
36、emoved from the packaging in such a way that the wire will not be subjected to tension or unnecessary bends. Before each test, sufficient wire should be discarded to ensure that any damaged wire is not included in the test specimens. 3.2.2 Winding wire One or more tape layers may be applied. Combina
37、tions of different types, different thickness and degree of overlap shall be agreed between the purchaser and the supplier. Where adhesive is used to secure the loose ends of the tape, it shall be compatible with the insulation system in use. The temperature in degrees Celsius corresponding to the t
38、emperature index is not necessarily that at which the wire is recommended to be operated and this will depend on many factors, including the types of equipment involved. BS EN 60317-53:2014IEC 60317-53:2014 IEC 2014 9 When reference is made to winding wire according to this standard, the following i
39、nformation should be given: reference to IEC 60317-53; dimensions of the conductor; reference should also be made to the number and thickness of the papers used and to the degree of overlap, as agreed between purchaser and supplier. 3.3 Appearance Before wrapping, the conductor shall be completely f
40、ree from copper dust and other extraneous matter. The tape covering shall be essentially smooth and continuous, wrapped around the conductor tightly, evenly and free from creases, wrinkles and foreign material when examined with normal vision, as wound on the original spool or reel. 4 Dimensions 4.1
41、 Conductor dimensions The dimensions for widths and thicknesses of conductors of winding wires with rectangular cross-section recommended in this standard are taken from the R 20 and R 40 series according to ISO 3. Preferred sizes are combinations of width and thickness both according to the R 20 se
42、ries. Intermediate sizes are combinations of width or thickness according to the R 20 series with the other dimension according to the R 40 series. This standard covers: widths from 2,00 mm up to and including 16,00 mm; thicknesses from 0,80 mm up to and including 5,60 mm.*The ratio width/thickness
43、shall be greater than or equal to 1,4:1 and shall not exceed 8:1. The actual values of dimensions are given in Table 1.*The nominal cross-sectional areas for preferred sizes are given in Table 1. _ *For thicknesses over 5,60 mm up to and including 10 mm and for widths over 16 mm up to and including
44、25 mm where, for technical reasons, additional sizes may be needed, the R 40 series shall be used. The ratio width/thickness shall be within the specified limits and combinations of R 40 and R 40 are not allowed in the case of additional sizes. *Dimensions according to R 20 series are printed in lar
45、ger type. BS EN 60317-53:2014 10 IEC 60317-53:2014 IEC 2014 Table 1Nominalcross-sectionalareas ofpreferredsizesBS EN 60317-53:2014IEC 60317-53:2014 IEC 2014 11 4.2 Tolerance on conductor dimensions The conductor dimensions shall not differ from the nominal values by more than the tolerance given in
46、Table 2. Table 2 Conductor tolerances Nominal width or thickness of the conductor mm Tolerance mm Over Up to and including 3,15 0,030 3,15 6,30 0,050 6,30 12,50 0,070 12,50 16,00 0,100 4.3 Rounding of corners The arc shall merge smoothly into the flat surfaces of the conductor and the strip shall be
47、 free from sharp, rough and projecting edges. The conductor shall have radiused corners complying with Table 3. The specified radii shall be maintained within 25 %. Table 3 Corner radii Nominal thickness of conductor mm Corner radius mm Over Up to and including 1,00 0,5 nominal thickness 1,00 1,60 0
48、,50* 1,60 2,24 0,65* 2,24 3,55 0,80 3,55 5,60 1,00 NOTE If agreed between purchaser and supplier, the corner radii for wires with a width greater than 4,8 mm may be: * 0,5 nominal thickness * 0,8 mm 4.4 Increase in dimensions due to tape covering As there are many varied constructions of this type o
49、f wire, the dimensions due to the insulation are subject to agreement between purchaser and supplier and shall be clearly stated in the purchase order. If there is no agreement, the minimum increase in width or thickness due to the tape covering shall not be less than the values calculated using the following formula: 2 Tmin.iniwhere Tmin.iis the minimum thickness of the paper in the layer number i and niis determined by the degree of overlap in th
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1