1、BSI Standards PublicationCoupling capacitors and capacitor dividersPart 2: AC or DC single-phase coupling capacitor connected between line and ground for power line carrier-frequency (PLC) applicationBS EN 60358-2:2013Copyright British Standards Institution Provided by IHS under license with BSI - U
2、ncontrolled Copy Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-National forewordThis British Standard is the UK implementation of EN 60358-2:2013. It isidentical to IEC 60358-2:2013. Together with BS EN 60358-1:2012, BS EN60358-3 and BS EN 60358-4 it supersedes B
3、S 7578:1992 (dual numbered asIEC 60358:1990), which will be withdrawn on publication of all parts of theBS EN 60358 series.The UK participation in its preparation was entrusted to TechnicalCommittee PEL/33, Power capacitors.A list of organizations represented on this committee can be obtained onrequ
4、est to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2014.Published by BSI Standards Limited 2014ISBN 978 0 580 71591 4ICS 29.120.99; 29.240.99; 31.060.70Compl
5、iance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 January 2014.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 60358-2:2013Copyri
6、ght British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-EUROPEAN STANDARD EN 60358-2 NORME EUROPENNE EUROPISCHE NORM December 2013 CENELEC European Committee for Electrotechnical S
7、tandardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. E
8、N 60358-2:2013 E ICS 29.120.99; 29.240.99; 31.060.70 Supersedes HD 597 S1:1992 (partially) English version Coupling capacitors and capacitor dividers - Part 2: AC or DC single-phase coupling capacitor connected between line and ground for power line carrier-frequency (PLC) application (IEC 60358-2:2
9、013) Condensateurs de couplage et diviseurs capacitifs - Partie 2: Condensateur de couplage monophas courant alternatif ou courant continu connect entre la ligne et la terre pour application aux liaisons courant porteur sur lignes dnergie (CPL) (CEI 60358-2:2013) Kopplungskondensatoren und kapazitiv
10、e Teiler - Teil 2: Einphasen-Kopplungskondensatoren fr Wechsel- oder Gleichstrom, die fr Trgerfrequenzbertragungen auf Hochspannungsleitungen (TFH-bertragung) zwischen Auenleiter und Erde geschaltet sind (IEC 60358-2:2013) This European Standard was approved by CENELEC on 2013-09-16. CENELEC members
11、 are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application
12、to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Ma
13、nagement Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland,
14、Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 60358-2:2013Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Cop
15、y Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-EN 60358-2:2013 - 2 - Foreword The text of document 33/531/FDIS, future edition 1 of IEC 60358-2, prepared by IEC/TC 33, “Power capacitors and their applications“ was submitted to the IEC-CENELEC parallel vote and a
16、pproved by CENELEC as EN 60358-2:2013. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2014-06-16 latest date by which the national standards conflicting with the documen
17、t have to be withdrawn (dow) 2016-09-16 This document supersedes HD 597 S1:1992 (partially). This European Standard is to be used in conjunction with the latest edition of EN 60358-1 and its amendments. It was established on the basis of the first edition (2012) of that standard. This Part 2 supplem
18、ents or modifies the corresponding clauses in EN 60358-1. When a particular subclause of Part 1 is not mentioned in this Part 2, that subclause applies as far as is reasonable. Where this Part 2 states “addition” or “replacement”, the relevant text in Part 1 is to be adapted accordingly. For additio
19、nal clauses, subclauses, figures, tables or annexes, the following numbering system is used: subclauses, tables and figures which are additional to those in Part 1 are numbered starting from 200; additional annexes are lettered AA, BB etc. as the notes are integrated into the clauses, their numberin
20、g starts from 1 as usual. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IE
21、C 60358-2:2013 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60085 NOTE Harmonized as EN 60085. IEC 60721 Series NOTE Harmonized in EN 60721 series. IEC 61462 N
22、OTE Harmonized as EN 61462. CISPR 16-1-1 NOTE Harmonized as EN 55016-1-1. BS EN 60358-2:2013Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo reproduction or networking permitted without license from IHS-,-,- 3 - EN 60358-2:2013 Annex
23、 ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies.
24、 For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60060-1 High-voltage test
25、 techniques - Part 1: General definitions and test requirements EN 60060-1 IEC 60060-2 High-voltage test techniques - Part 2: Measuring systems EN 60060-2 IEC 60358-1 + corr. July 2012 2013 Coupling capacitors and capacitor dividers - Part 1: General rules EN 60358-1 + AC:2013 2012 2013 IEC 60481 Co
26、upling devices for power line carrier systems - - IEC 61869-5 Instrument transformers - Part 5: Additional requirements for capacitor voltage transformers BS EN 60358-2:2013Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo reproductio
27、n or networking permitted without license from IHS-,-,- 2 60358-2 IEC:2013 CONTENTS INTRODUCTION . 6 1 Scope . 7 2 Normative references . 7 3 Terms and definitions . 7 3.200 Carrier-frequency accessories definitions . 8 4 Service conditions 8 5 Ratings . 8 6 Design requirements 8 6.200 Design requir
28、ements for coupling capacitor and carrier-frequency accessories 8 6.200.1 Design requirements for coupling capacitor 8 6.200.2 Design requirements for carrier-frequency accessories . 9 7 Test conditions . 10 8 Classification of tests . 10 8.1 General . 10 8.2 Routine tests . 10 8.2.200 General 10 8.
29、2.201 Routine tests for carrier frequency accessories . 10 8.3 Type tests . 10 8.3.200 Type test for coupling capacitor and carrier-frequency accessories 10 8.4 Special tests 11 9 Routine tests 11 9.1 Tightness of the liquid-filled equipment 11 9.2 Electrical routine tests . 11 9.2.200 Electrical te
30、sts for coupling capacitor and carrier frequency accessories 11 10 Type tests 12 10.200 Test on capacitor 12 10.200.1 High frequency capacitance and equivalent series resistance . 12 10.200.2 Measurement of the stray capacitance and stray conductance of the low voltage terminal 12 10.201 Type test o
31、n carrier frequency accessories . 13 10.201.1 General 13 10.201.2 Type tests for drain coil 13 10.201.3 Type test for voltage limitation device together with drain coil: Impulse voltage test 14 11 Special tests . 14 12 Marking 15 12.1 General 15 12.2 Marking of capacitor . 15 12.200 Marking of the c
32、arrier-frequency accessories . 15 Annexes . 15 Annex A (informative) Typical diagram of an equipment . 16 BS EN 60358-2:2013Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo reproduction or networking permitted without license from IH
33、S-,-,-60358-2 IEC:2013 3 Annex AA (informative) High-frequency characteristics of coupling capacitors for power line carrier circuits 17 Bibliography 19 Figure A.200.1 Example of a diagram for a coupling capacitor with carrier-frequency accessories (see IEC 60481) 16 Figure AA.1 Wiring diagram of th
34、e measuring circuit for the high-frequency capacitance and equivalent series resistance of a coupling capacitor . 18 Figure AA.2 Relation between length and capacitance where capacitive deviation 20 % to +50 % can be fulfilled up to 500 kHz 18 Table 200 Limits of temperature rise of windings 14 BS E
35、N 60358-2:2013Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo reproduction or networking permitted without license from IHS-,-,- 6 60358-2 IEC:2013 INTRODUCTION This series consists of the following parts: IEC 60358-1, Coupling capa
36、citors and capacitor dividers Part 1: General rules IEC 60358-2, Coupling capacitors and capacitor dividers Part 2: AC or DC single-phase coupling capacitor connected between line and ground for power line carrier-frequency (PLC) application IEC 60358-31, Coupling capacitors and capacitor dividers P
37、art 3: AC or DC single-phase coupling capacitor connected between line and ground for harmonic-filters applications IEC 60358-42, Coupling capacitors and capacitor dividers Part 4: AC or DC single-phase capacitor-divider and RC-divider connected between line and ground (except for CVTs which belong
38、to IEC 61869 series) 1Under consideration. 2Under consideration. BS EN 60358-2:2013Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-60358-2 IEC:2013 7 COUPLING CAPACIT
39、ORS AND CAPACITOR DIVIDERS Part 2: AC or DC single-phase coupling capacitor connected between line and ground for power line carrier-frequency (PLC) application 1 Scope Clause 1 of IEC 60358-1:2012 is applicable with the following additions: This part of the IEC 60358 series applies to AC or DC sing
40、le-phase coupling capacitors, with rated voltage 1 000 V, connected between line and ground with a low voltage terminal either permanently earthed or connected to a device for power line carrier-frequency (PLC) applications at frequencies from 30 kHz to 500 kHz or similar applications (DC or AC) at
41、power frequencies from 15 Hz to 60 Hz. The transmission requirements for coupling devices for power line carrier (PLC) systems are defined in IEC 60481. NOTE Diagrams of coupling capacitors to which this standard applies are given in Figure A.1. 2 Normative references Clause 2 of IEC 60358-1:2012 is
42、 replaced by the following: The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any
43、amendments) applies. IEC 60060-1, High-voltage test techniques Part 1: General definitions and test requirements IEC 60060-2, High-voltage test techniques Part 2: Measuring systems IEC 60358-1:2012, Coupling capacitors and capacitor dividers. Part 1: General rules IEC 60481, Coupling devices for pow
44、er line carrier systems IEC 61869-5, Instrument transformers Part 5: Additional requirements for capacitor voltage transformers 3 Terms and definitions Clause 3 of IEC 60358-1:2012 is applicable with the following additions: For the purposes of this document, the terms and definitions given in Claus
45、e 3 of IEC 60358-1:2012, as well as the following apply. BS EN 60358-2:2013Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo reproduction or networking permitted without license from IHS-,-,- 8 60358-2 IEC:2013 3.200 Carrier-frequency
46、 accessories definitions 3.200.1 coupling device arrangement of elements which contribute to ensure, together with one or more associated coupling capacitors, the transmission, under prescribed conditions, of carrier-frequency signals between one or more conductors of the power line and the carrier-
47、frequency connection 3.200.2 carrier-frequency accessories circuit element intended to permit the injection of carrier frequency signal and which is connected between the low voltage terminal of a coupling capacitor unit and earth, and having an impedance which is insignificant at the power frequenc
48、y, but appreciable at carrier frequency Note 1 to entry: See Figure A.1. 3.200.3 drain coil inductance which is connected between the low voltage terminal of a coupling capacitor and earth, and whose impedance is insignificant at the power frequency, but has a high value at the carrier frequency 3.200.4 voltage limitation device element connected between the coupling capacitor and earth to limit the overvoltages which appear across the coupling device. Note 1 to entry: Overvoltages appear in case of: a) a short circ