1、BSI Standards PublicationOptical fibre cablesPart 3-12: Outdoor cables Detailed specification for duct and directly buried optical telecommunication cables for use in premises cablingBS EN 60794-3-12:2013National forewordThis British Standard is the UK implementation of EN 60794-3-12:2013. It isiden
2、tical to IEC 60794-3-12:2012. It supersedes BS EN 60794-3-12:2006which is withdrawn.The UK participation in its preparation was entrusted by TechnicalCommittee GEL/86, Fibre optics, to Subcommittee GEL/86/1, Optical fibresand cables.A list of organizations represented on this committee can be obtain
3、ed onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2013Published by BSI Standards Limited 2013ISBN 978 0 580 60668 7ICS 33.180.10Compliance with a B
4、ritish Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 July 2013.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 60794-3-12:2013EUROPEAN STANDARD EN 6
5、0794-3-12 NORME EUROPENNE EUROPISCHE NORM June 2013 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2013 CENELEC - All rights of exp
6、loitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60794-3-12:2013 E ICS 33.180.10 Supersedes EN 60794-3-12:2006 English version Optical fibre cables - Part 3-12: Outdoor cables - Detailed specification for duct and directly buried optical telecommunication ca
7、bles for use in premises cabling (IEC 60794-3-12:2012) Cbles fibres optiques - Partie 3-12: Cbles extrieurs - Spcification particulire pour les cbles optiques de tlcommunication destins tre installs dans des conduites ou tre directement enterrs et utiliss dans le cblage de locaux (CEI 60794-3-12:201
8、2) Lichtwellenleiterkabel - Teil 3-12: LWL-Auenkabel - Produktspezifikation fr LWL-Fernmelde-Erd- und Rhrenkabel fr anwendungsneutrale Standortverkabelung (IEC 60794-3-12:2012) This European Standard was approved by CENELEC on 2013-01-16. CENELEC members are bound to comply with the CEN/CENELEC Inte
9、rnal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any
10、 CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the off
11、icial versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg,
12、 Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 60794-3-12:2013EN 60794-3-12:2013 - 2 - Foreword The text of document 86A/1471/FDIS, future edition 2 of IEC 60794-3-12, prepared by SC 86A, “Fibres and ca
13、bles“, of IEC TC 86, “Fibre optics“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60794-3-12:2013. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsemen
14、t (dop) 2013-12-28 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2016-01-16 This document supersedes EN 60794-3-12:2006. EN 60794-3-12:2013 includes the following significant technical changes with respect to EN 60794-3-12:2006: reference to ISO
15、/IEC 24702; reference to Fibre B6 (EN 60793-2-50); reference to Fibre A1a.3 (EN 60793-2-10); reference to the OS2 Fibre as defined by ISO/IEC 11801 reference to the OM4 Fibre as defined by ISO/IEC 11801. This International Standard is to be used in conjunction with EN 60794-1-1, EN 60794-1-2 and EN
16、60794-3-10. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 60794-3-12:2
17、012 was approved by CENELEC as a European Standard without any modification. BS EN 60794-3-12:2013- 3 - EN 60794-3-12:2013 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normativ
18、ely referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by commo
19、n modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60793-2-10 2011 Optical fibres - Part 2-10: Product specifications - Sectional specification for category A1 multimode fibres EN 60793-2-10 2011 IEC 60793-2-50 2012 Optical fibres - Part 2-50: Prod
20、uct specifications - Sectional specification for class B single-mode fibres EN 60793-2-50 2013 IEC 60794-1-1 - Optical fibre cables - Part 1-1: Generic specification - General EN 60794-1-1 - IEC 60794-1-2 - Optical fibre cables - Part 1-2: Generic specification - Basic optical cable test procedures
21、EN 60794-1-2- IEC 60794-3 - Optical fibre cables - Part 3: Sectional specification - Outdoor cables EN 60794-3 - IEC 60794-3-10 - Optical fibre cables - Part 3-10: Outdoor cables - Family specification for duct, directly buried and lashed aerial optical telecommunication cables EN 60794-3-10 - ISO/I
22、EC 11801 - Information technology - Generic cabling for customer premises - - ISO/IEC 24702 - Information technology - Generic cabling - Industrial premises - - BS EN 60794-3-12:2013 2 60794-3-12 IEC:2012 CONTENTS 1 Scope . 5 2 Normative references . 5 3 General requirements . 6 4 Particular require
23、ments 6 General . 6 4.1MICE (mechanical, ingress, climatic and chemical and electromagnetic) 4.2characteristics . 6 Transmission requirements 7 4.3Attenuation of cabled fibre . 7 4.3.1Fibre bandwidth requirements 7 4.3.2Polarization mode dispersion (PMD) requirements . 8 4.3.3Bibliography 9 Table 1
24、Multimode maximum cable attenuation coefficient (dB/km) 7 Table 2 Single-mode maximum cable attenuation coefficient (dB/km) 7 Table 3 Minimum multimode fibre bandwidth (MHz km) . 8 BS EN 60794-3-12:201360794-3-12 IEC:2012 5 OPTICAL FIBRE CABLES Part 3-12: Outdoor cables Detailed specification for du
25、ct and directly buried optical telecommunication cables for use in premises cabling 1 Scope This part of IEC 60794 is a detailed specification for duct and directly buried optical telecommunication cables for use in premises cabling to ensure compatibility with ISO/IEC 11801 and ISO/IEC 24702. Those
26、 standards have requirements to ensure that models work for generic cabling and system performances. Values in this standard support these models. The requirements of the family specification IEC 60794-3-10 are applicable to cables covered by this standard. Particular requirements detailed in Clause
27、 4 of this standard either define a specific option relative to the requirements of IEC 60794-3-10 or define additional requirements. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated
28、references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE These references complete the normative references already listed in the generic specifications IEC 60794-1-1 and IEC 60794-1-2, in the sectional
29、 specification IEC 60794-3 and in the family specification IEC 60794-3-10. IEC 60793-2-10:2011, Optical fibres Part 2-10: Product specifications Sectional specification for category A1 multimode fibres IEC 60793-2-50:2012, Optical fibres Part 2-50: Product specifications Sectional specification for
30、class B single-mode fibres IEC 60794-1-1, Optical fibre cables Part 1-1: Generic specification Cross reference table for optical cable test procedures IEC 60794-1-2, Optical fibre cables Part 1-2: Generic specification Cross reference table for optical cable test procedures1IEC 60794-3, Optical fibr
31、e cables Part 3: Sectional specification Outdoor cables IEC 60794-3-10, Optical fibre cables Part 3-10: Outdoor cables Family specification for duct, directly buried and lashed aerial optical telecommunication cables ISO/IEC 11801, Information technology Generic cabling for customer premises _ 1IEC
32、60794-1-2:2003, Second edition has been withdrawn. A third edition, with the revised title Optical fibre cables - Part 1-2: Generic specification - Cross reference table for optical cable test procedures, is currently in preparation. BS EN 60794-3-12:2013 6 60794-3-12 IEC:2012 ISO/IEC 24702, Informa
33、tion technology Generic cabling Industrial premises 3 General requirements The cable shall comply with the family specification, IEC 60794-3-10, and meet the requirements which are defined in it, including requirements in the sectional specification, 60794-3. Particular requirements detailed in Clau
34、se 4 are optional, relative to the requirements of IEC 60794-3-10, or define additional requirements. The optical fibre contained in cables covered by this standard shall comply with one of the following standards, and meet the normative requirements defined within them as applicable: IEC 60793-2-50
35、:2008, Annex A (Single-mode fibre category B1.1); IEC 60793-2-50:2008, Annex C (Single-mode fibre category B1.3) ; IEC 60793-2-50:2008, Annex G (Single-mode fibre sub-categories B6 a1 and B6 a2) IEC 60793-2-10:2011, Annex A (Multimode fibre sub-category A1a, 50 m core diameter); IEC 60793-2-10:2011,
36、 Annex B (Multimode fibre sub-category A1b, 62,5 m core diameter). To ensure compatibility with ISO/IEC 11801 and ISO/IEC 24702, optical performance level requirements are presented in terms of the performance classification codes as follows: OS1 Single-mode fibre categories B1.1, B1.3 or sub-catego
37、ries B6 a1, B6 a2; OS2 Single-mode fibre category B1.3 or sub-categories B6 a1, B6 a2; OM1 Multimode fibre sub-categories A1a, A1b; OM2 Multimode fibre sub-categories A1a, A1b; OM3 Multimode fibre model A1a.2; OM4 Multimode fibre model A1a.3. NOTE These codes are informative from the perspective of
38、the requirements defined in this detailed specification. 4 Particular requirements General 4.1These requirements either define a specific option relative to the requirements of IEC 60794-3-10 or define additional requirements. MICE (mechanical, ingress, climatic and chemical and electromagnetic) 4.2
39、characteristics Cables intended for installation in conformity with ISO/IEC 24702,and related standards, may require the specification of additional tests to ensure their suitability in the applicable environments defined by the mechanical, ingress, climatic and chemical and electromagnetic (MICE) c
40、lassification. Such tests are outside the scope of IEC 60794 cable specifications, and MICE criteria are not part of the requirements for IEC 60794 specifications. The MICE tests may be the same as, similar to, or substantially different from, the tests required by IEC 60794 specifications. Cables m
41、anufactured per IEC 60794 specifications may or may not meet the MICE criteria. For supplemental discussion see IEC/TR 62362 12. _ 2Numbers in square brackets refer to the Bibliography. BS EN 60794-3-12:201360794-3-12 IEC:2012 7 Transmission requirements 4.3Attenuation of cabled fibre 4.3.1Depending
42、 on the fibre type, the attenuation coefficient of the cabled fibre shall be less than the maximum values in Table 1 for multimode fibres, and less than the maximum values in Table 2 for single-mode fibres, for the wavelengths as stated in Tables 1 and 2. The fibre category, sub-category or model as
43、 applicable shall be agreed between customer and supplier. Table 1 Multimode maximum cable attenuation coefficient (dB/km) Fibre Attenuation coefficient at 850 nm Attenuation coefficient at 1 300 nm Performance code IEC 60793-2-10:2011, A1a.1 3,5 1,5 OM1, OM2 IEC 60793-2-10:2011, A1a.2 3,5 1,5 OM1,
44、OM2, OM3 IEC 60793-2-10:2011, A1a.3 3,5 1,5 OM1, OM2, OM3, OM4 IEC 60793-2-10:2011, A1b 3,5 1,5 OM1, OM2 Table 2 Single-mode maximum cable attenuation coefficient (dB/km) Fibre Wavelengths nm Maximum attenuation coefficient Performance code IEC 60793-2-50:2008, B1.1, B1.3, B6 a1 or B6 a2 1 310, 1 55
45、0 1,0 OS1 IEC 60793-2-50:2008, B1.3, B6 a1 or B6 a2 1 310, 1 383, 1 550 0,4 OS2 NOTE Optical fibre B6 a is recommended when it is expected that the optical fibre or the cable will have to support smaller bend radii than 25 mm. Fibre bandwidth requirements 4.3.2There are no bandwidth requirements on
46、single-mode fibre. For cables containing multimode fibres, the uncabled fibre shall be specified at one of performance levels defined in Table 3 in terms of minimum bandwidth (MHz km), wavelength, and type of measurement. The fibre category, sub-category or model as applicable and performance level
47、shall be agreed between customer and supplier. BS EN 60794-3-12:2013 8 60794-3-12 IEC:2012 Table 3 Minimum multimode fibre bandwidth (MHz km) Fibre Nominal core diameter m Overfilled bandwidth at 850 nm Overfilled bandwidth at 1 300 nm Effective modal bandwidth at 850 nm Performance code IEC 60793-2
48、-10:2011, A1a.1 50 200 500 N/A OM1 IEC 60793-2-10:2011, A1a.1 50 500 500 N/A OM2 IEC 60793-2-10:2011, A1a.2 50 1 500 500 2 000 OM3 IEC 60793-2-10:2011, A1a.3 50 3 500 500 4 700 OM4 IEC 60793-2-10:2011, A1b 62,5 200 500 N/A OM1 IEC 60793-2-10:2011, A1b 62,5 500 500 N/A OM2 N/A Not applicable. Polariz
49、ation mode dispersion (PMD) requirements 4.3.3Cables containing single-mode fibres shall meet the PMD requirement of IEC 60794-3. This is given as a link design value, PMDQ, with a maximum of 0,5 ps/km1/2allowed. BS EN 60794-3-12:201360794-3-12 IEC:2012 9 Bibliography 1 IEC/TR 62362, Selection of optical fibre cable specifications relative to mechanical, ingress, climatic or electromagnetic c