1、BSI Standards PublicationAlarm and electronicsecurity systemsPart 11-1: Electronic access controlsystems System and componentsrequirementsBS EN 60839-11-1:2013Incorporating corrigenda November 2013 and February 2015BS EN 60839-11-1:2013 BRITISH STANDARDNational forewordThis British Standard is the U
2、K implementation of EN 60839-11-1:2013,incorporating corrigenda November 2013 and February 2015. It isidentical to IEC 60839-11-1:2013. It supersedes BS EN 50133-1:1997and BS EN 50133-2-1:2000, which are withdrawn.The UK participation in its preparation was entrusted by TechnicalCommittee GW/1, Elec
3、tronic security systems, to Subcommittee GW/1/8,Access control.A list of organizations represented on this subcommittee can beobtained on request to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application
4、. The British Standards Institution 2015.Published by BSI Standards Limited 2015ISBN 978 0 580 89897 6ICS 13.320Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Committee on 30
5、November 2013.Amendments/corrigenda issued since publicationDate Text affected31 January 2014 Implementation of CENELEC corrigendumNovember 2013: supersession information updatedon CENELEC title page and in CENELEC foreword31 March 2015 Implementation of CENELEC corrigendum February 2015: supersessi
6、on information updatedin National foreword and CENELEC forewordEUROPEAN STANDARD EN 60839-11-1 NORME EUROPENNE EUROPISCHE NORM June 2013 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Ma
7、nagement Centre: Avenue Marnix 17, B - 1000 Brussels 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60839-11-1:2013 E ICS 13.320 English version Alarm and electronic security systems - Part 11-1: Electronic access control sy
8、stems - System and components requirements (IEC 60839-11-1:2013) Systmes dalarme et de scurit lectroniques - Partie 11-1: Systmes de contrle daccs lectronique - Exigences systme et exigences concernant les composants (CEI 60839-11-1:2013) Alarmanlagen - Teil 11-1: Elektronische Zutrittskontrollanlag
9、en - Anforderungen an Anlagen und Gerte (IEC 60839-11-1:2013) This European Standard was approved by CENELEC on 2013-06-11. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard
10、 without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in a
11、ny other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia
12、, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey
13、and the United Kingdom. Supersedes EN 50133-1:1996Supersedes EN 50133-1:1996 and EN 50133-2-1:2000EN 60839-11-1:2013 - 2 - Foreword The text of document 79/410/FDIS, future edition 1 of IEC 60839-11-1, prepared by IEC TC 79 “Alarm and electronic security systems“ was submitted to the IEC-CENELEC par
14、allel vote and approved by CENELEC as EN 60839-11-1:2013. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2014-03-11 latest date by which the national standards conflicti
15、ng with the document have to be withdrawn (dow) 2016-06-11 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text
16、 of the International Standard IEC 60839-11-1:2013 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60950-1 NOTE Harmonised as EN 60950-1. IEC 61000-6-1 NOTE Harmo
17、nised as EN 61000-6-1. IEC 61000-6-3 NOTE Harmonised as EN 61000-6-3. BS EN 60839-11-1:2013This document supersedes EN 50133-1:1996. and EN 50133-2-1:2000.EN 60839-11-1:2013 - 2 - Foreword The text of document 79/410/FDIS, future edition 1 of IEC 60839-11-1, prepared by IEC TC 79 “Alarm and electron
18、ic security systems“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60839-11-1:2013. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2014-03
19、-11 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2016-06-11 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying a
20、ny or all such patent rights. Endorsement notice The text of the International Standard IEC 60839-11-1:2013 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60950-
21、1 NOTE Harmonised as EN 60950-1. IEC 61000-6-1 NOTE Harmonised as EN 61000-6-1. IEC 61000-6-3 NOTE Harmonised as EN 61000-6-3. BS EN 60839-11-1:2013This document supersedes EN 50133-1:1996.- 3 - EN 60839-11-1:2013 Annex ZA (normative) Normative references to international publications with their cor
22、responding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including
23、 any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60068-1 - Environmental testing - Part 1: General and guidance EN 60068-1 - IEC 60529 - Degrees of protect
24、ion provided by enclosures (IP Code) - - IEC 62262 - Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) EN 62262 - IEC 62599-1 - Alarm systems - Part 1: Environmental test methods - - IEC 62599-2 - Alarm systems - Part 2: Electromagnet
25、ic compatibility - Immunity requirements for components of fire and security alarm systems - - IEC 62642-1 - Alarm systems - Intrusion and hold-up systems - Part 1: System requirements - - IEC 62642-6 - Alarm systems - Intrusion and hold-up systems - Part 2-6: Intrusion detectors - Opening contacts
26、(magnetic) - - BS EN 60839-11-1:2013 2 60839-11-1 IEC:2013 CONTENTS INTRODUCTION . 7 1 Scope . 8 2 Normative references . 8 3 Terms and definitions . 9 4 Abbreviations . 20 5 Conceptual models and system architecture . 20 6 System performance functionality requirements 23 6.1 Classification methodol
27、ogy and functionalities Determining the levels of protection 23 6.2 Access point interface requirements 25 6.2.1 Portal release timing 25 6.2.2 Access control . 25 6.2.3 Portal status 25 6.3 Indication and annunciation (display, alert, logging) requirements . 26 6.3.1 Annunciation . 26 6.3.2 Display
28、 26 6.3.3 Alert 26 6.3.4 Logging . 27 6.4 Recognition requirements 29 6.5 Duress signalling requirements . 32 6.6 Overriding requirements 32 6.7 Communication requirements 33 6.8 System self-protection requirements 33 6.9 Power supply requirements . 35 7 Environmental and EMC (immunity) requirements
29、. 36 8 Test methods 38 8.1 General conditions 38 8.1.1 Atmospheric conditions for tests 38 8.1.2 Operating conditions for tests 38 8.1.3 Specimen configuration . 38 8.1.4 Mounting arrangements . 39 8.1.5 Tolerances 39 8.1.6 Provisions for tests 39 8.1.7 Optional functions 39 8.2 Reduced functional t
30、est . 41 8.3 Functional tests for access point interface . 41 8.3.1 Object of the test . 41 8.3.2 Principle 41 8.3.3 Procedure 41 8.3.4 Criteria for compliance . 43 8.4 Functional tests for indication/annunciation (displaying, alert and logging) 43 8.4.1 Object of the test . 43 8.4.2 Principles 43 8
31、.4.3 Test procedure 43 8.4.4 Criteria for compliance . 46 BS EN 60839-11-1:2013 2 60839-11-1 IEC:2013 CONTENTS INTRODUCTION . 7 1 Scope . 8 2 Normative references . 8 3 Terms and definitions . 9 4 Abbreviations . 20 5 Conceptual models and system architecture . 20 6 System performance functionality
32、requirements 23 6.1 Classification methodology and functionalities Determining the levels of protection 23 6.2 Access point interface requirements 25 6.2.1 Portal release timing 25 6.2.2 Access control . 25 6.2.3 Portal status 25 6.3 Indication and annunciation (display, alert, logging) requirements
33、 . 26 6.3.1 Annunciation . 26 6.3.2 Display 26 6.3.3 Alert 26 6.3.4 Logging . 27 6.4 Recognition requirements 29 6.5 Duress signalling requirements . 32 6.6 Overriding requirements 32 6.7 Communication requirements 33 6.8 System self-protection requirements 33 6.9 Power supply requirements . 35 7 En
34、vironmental and EMC (immunity) requirements. 36 8 Test methods 38 8.1 General conditions 38 8.1.1 Atmospheric conditions for tests 38 8.1.2 Operating conditions for tests 38 8.1.3 Specimen configuration . 38 8.1.4 Mounting arrangements . 39 8.1.5 Tolerances 39 8.1.6 Provisions for tests 39 8.1.7 Opt
35、ional functions 39 8.2 Reduced functional test . 41 8.3 Functional tests for access point interface . 41 8.3.1 Object of the test . 41 8.3.2 Principle 41 8.3.3 Procedure 41 8.3.4 Criteria for compliance . 43 8.4 Functional tests for indication/annunciation (displaying, alert and logging) 43 8.4.1 Ob
36、ject of the test . 43 8.4.2 Principles 43 8.4.3 Test procedure 43 8.4.4 Criteria for compliance . 46 BS EN 60839-11-1:201360839-11-1 IEC:2013 3 8.5 Test methods for recognition functionalities . 46 8.5.1 Object of the test . 46 8.5.2 Principles 47 8.5.3 Test procedure 47 8.5.4 Criteria for complianc
37、e . 48 8.6 Functional tests for duress signalling . 48 8.6.1 Object of the test . 48 8.6.2 Principles 48 8.6.3 Test procedure (ref. Table 5, lines 1 to 3) 48 8.6.4 Criteria for compliance . 49 8.7 Functional tests for overriding . 49 8.7.1 Object of the test . 49 8.7.2 Principles 49 8.7.3 Test proce
38、dure (ref. Table 6, lines 1 to 7) 49 8.7.4 Criteria for compliance . 49 8.8 Functional tests for communication and self-protection 50 8.8.1 Object of the test . 50 8.8.2 Principles 50 8.8.3 Test procedure (ref. Table 7, lines 1 to 28) 50 8.8.4 Criteria for compliance . 51 8.9 Power supply requiremen
39、ts . 51 8.9.1 Test of standby power duration 51 8.9.2 Test of charger and standby power source capacity . 52 8.9.3 Test for low or missing battery condition 53 8.10 Environmental and EMC (immunity) tests 53 8.10.1 Test procedure 53 8.10.2 Initial measurements . 54 8.10.3 State of the specimen during
40、 conditioning . 54 8.10.4 Conditioning 54 8.10.5 Measurement during conditioning 54 8.10.6 Final measurements 54 8.10.7 Criteria for compliance . 54 8.11 Test report 54 9 Documentation and marking . 55 9.1 Documentation 55 9.2 Marking . 55 Annex A (normative) Timing diagram . 57 Bibliography 58 Figu
41、re 1 Conceptual model 22 Figure 2 Typical architecture of an electronic access control system 23 Figure 3 Example of system test configuration . 40 Figure A.1 Timing diagram . 57 Table 1 Grade classification . 24 Table 2 Access point interface requirements . 25 Table 3 Indication and annunciation re
42、quirements . 27 BS EN 60839-11-1:2013 4 60839-11-1 IEC:2013 Table 4 Recognition requirements . 30 Table 5 Duress signalling requirements . 32 Table 6 Overriding requirements 32 Table 7 System self-protection requirements 34 Table 8 Power supply requirements . 36 Table 9 Environmental and EMC (immuni
43、ty) requirements 37 BS EN 60839-11-1:2013 4 60839-11-1 IEC:2013 Table 4 Recognition requirements . 30 Table 5 Duress signalling requirements . 32 Table 6 Overriding requirements 32 Table 7 System self-protection requirements 34 Table 8 Power supply requirements . 36 Table 9 Environmental and EMC (im
44、munity) requirements 37 BS EN 60839-11-1:201360839-11-1 IEC:2013 7 INTRODUCTION This standard is part of the IEC 60839 series, written to include the following parts: Part 11-1 Electronic access control systems System and components requirements Part 11-2 Electronic access control systems Applicatio
45、n guidelines This part of IEC 60839 describes the general requirements for functionalities of electronic access control systems (EACS) for use in security applications. The design, planning, installation, operation, and maintenance are part of the application guidelines in IEC 60839-11-21. The risk
46、analysis is not part of this standard and the risk levels are for informational purposes only. An electronic access control system consists of one or more components that when interconnected meet the functionality criteria stated in this standard. This standard defines different security grades and
47、the functionalities of the access control system associated with each of these grades. It includes also the minimum environmental and EMC compliance criteria as applicable for components of the electronic access control system in every grade. When a part of an electronic access control system (e.g.
48、access point interface) forms a part of an alarm system (intrusion, hold-up, VSS Video Surveillance Systems, etc.) that part shall also fulfil the relevant requirements of the applicable IEC standards. Functions additional to the mandatory functions specified in this standard may be included in the
49、electronic access control system providing they do not prevent the requirements of this standard from being met. This International standard also applies to access control systems sharing means of recognition, detection, triggering, interconnection, control, communication, alert signalling and power supplies with other applications. The operation of an access control system should not be adversely influenced by other applications. An electronic access control system may