1、BRITISH STANDARD BS EN 61076-3-101:1997IncorporatingcorrigendumApril 2010Connectors with assessed quality, for use in d.c., low-frequency analogue and in digital high-speed data applications Part 3: Rectangular connectors Section 101: Detail specification for a range of shielded connectors with trap
2、ezoidal shaped shells and non-removable rectangular contacts on a1,27 2,54mm centre-lineICS 31.220.10Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 27/10/2010 07:31, Uncontrolled Copy, (c) BSINational forewordThis British Standard is the UK implementation of EN 61076-3-101:1997. It is identi
3、cal to IEC 61076-3-101:1997, incorporating corrigendum April 2010. It supersedes BS EN 61076-3-101:1998 which is withdrawn.The UK participation in its preparation was entrusted by Technical Committee EPL/48, Electromechanical components for electronic equipment, to Subcommittee EPL/48/2, Connectors
4、for electronic equipment.A list of organizations represented on this subcommittee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard
5、cannot confer immunity from legal obligations.BS EN 61076-3-101:1997This British Standard, having been prepared under the direction of the Electrotechnical Sector Board, was published under the authority of the Standards Board and comesinto effect on 15 January 1998 BSI 2010Amendments/corrigenda iss
6、ued since publicationDate Comments 31 July 2010 Implementation of IEC corrigendum April 2010; Table in Figure 25 replaced. BSI and CENELEC publication dates alignedISBN 978 0 580 71378 1Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 27/10/2010 07:31, Uncontrolled Copy, (c) BSIEUROPEAN STANDA
7、RDNORME EUROPENNEEUROPISCHE NORMEN 61076-3-101October 1997ICS 31.220.10English versionConnectors with assessed quality, for use in d.c. low-frequency analogue and in digital high-speed data applications Part 3: Rectangular connectors Section101:Detail specification for a range of shielded connectors
8、 with trapezoidal shaped shells and non-removable rectangular contacts on a1,27mm2,54mmcentre-line(IEC 61076-3-101:1997)Connecteurs sous assurance de la qualit, pour utilisation dans le cadre dapplications analogiques en courant continu et basse frquence et dans le cadre dapplications numriques util
9、isant des dbits lvs pour le transfert des donnes Partie 3: Connecteurs rectangulaires Section 101: Spcification particulire pour une famille de connecteurs blinds avec botiers trapzodaux et contacts non-dmontables de section rectangulaire au pas de1,27mm2,54mm (CEI 61076-3-101:1997)Steckverbinder mi
10、t bewerteter Qualitt fr Gleichspannungs- undNiederfrequenz-anwendungen sowie digitale Anwendungen mit hoher bertragungsrate Teil 3: Rechteckige Steckverbinder Hauptabschnitt101: Bauartspezifikation fr eine Reihe von geschirmten Steckverbindern mit trapezfrmigen Kragen und nicht auswechselbaren recht
11、eckigen Kontakten im Raster von 1,27mm 2,54mm (IEC61076-3-101:1997)This European Standard was approved by CENELEC on 1997-10-01.CENELEC members are bound to comply with the CEN/CENELEC InternalRegulations which stipulate the conditions for giving this European Standardthe status of a national standa
12、rd without any alteration.Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to anyCENELEC member.This European Standard exists in three official versions (English, French,German). A version in any other lang
13、uage made by translation under theresponsibility of a CENELEC member into its own language and notified to theCentral Secretariat has the same status as the official versions.CENELEC members are the national electrotechnical committees of Austria,Belgium, Denmark, Finland, France, Germany, Greece, I
14、celand, Ireland, Italy,Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland andUnited Kingdom.CENELECEuropean Committee for Electrotechnical StandardizationComit Europen de Normalisation ElectrotechniqueEuropisches Komitee fr Elektrotechnische NormungCentral Secretariat: rue de Stas
15、sart 35, B-1050 Brussels 1997 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61076-3-101:1997 ELicensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 27/10/2010 07:31, Uncontrolled Copy, (c) BSI BSI 20102ForewordThe text of documen
16、t48B/531/FDIS, future edition1 of IEC61076-3-101, prepared by SC48B, Connectors, of IECTC48, Electromechanical components and mechanical structures for electronic equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN61076-3-101on1997-10-01.The following dates we
17、re fixed:Annexes designated “normative” are part of the body of the standard.In this standard, Annex A,Annex B, Annex CandAnnex ZA are normative.Annex ZA has been added by CENELEC.Endorsement noticeThe text of the International Standard IEC61076-3-101:1997 was approved by CENELEC as a European Stand
18、ard without any modification.ContentsPageForeword 21 General data 51.1 Recommended method of mounting 51.2 Ratings and characteristics 51.3 Reference documents 61.4 Marking 61.4.1 On the connector 61.4.2 On the package 61.5 IEC type designation 71.6 Ordering information 82 Technical data 82.1 Defini
19、tions 82.2 Survey of styles and variants 82.3 Information on application 93 Dimensional information 93.1 General 93.2 Isometric view and common features 93.2.1 Common features 93.3 Mating information 103.3.1 Contact arrangement for fixed and free connectors 103.4 Fixed connectors 123.4.1 Dimensions
20、123.4.2 Contact arrangement 243.4.3 Termination 243.5 Free connectors 243.5.1 Dimensions 243.5.2 Contact arrangement 313.5.3 Termination 313.6 Accessories 323.7 Mounting information for fixed connectors with male or female contacts 323.7.1 Printed boards 323.7.2 Mounting on panel 403.8 Mounting info
21、rmation for free connectors 423.9 Gauges 423.9.1 Sizing and retention force gauges 423.9.2 Endurance, engaging/separating, insertion/withdrawal force gauges 433.9.3 Probes 433.9.4 Test panel (for voltage proof test) 434 Characteristics 434.1 Climatic category 43 latest date by which the EN has to be
22、 implemented at national level by publication of an identical national standard or by endorsement (dop) 1998-07-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 1998-07-01BS EN 61076-3-101:1997EN 61076-3-101:1997 (E)Licensed Copy: Wang Bin, ISO/EXCHAN
23、GE CHINA STANDARDS, 27/10/2010 07:31, Uncontrolled Copy, (c) BSI BSI 2010 3Page4.2 Electrical 434.2.1 Creepage and clearance distances 434.2.2 Voltage proof 444.2.3 Current-carrying capacity 444.2.4 Initial contact resistance 444.2.5 Initial insulation resistance 454.3 Mechanical 454.3.1 Mechanical
24、operation 454.3.2 Insertion and withdrawal forces 454.3.3 Contact retention in insert 464.3.4 Static load, axial 465 Test schedule 465.1 General 465.1.1 Arrangement for contact resistancemeasurement 475.1.2 Arrangement for dynamic stress tests 475.1.3 Arrangement for testing static load, axial 475.1
25、.4 Wiring of specimens 475.2 Test schedule tables 475.2.1 Basic test schedule 475.2.2 Preliminary group P 475.2.3 Group AP 485.2.4 Group BP 505.2.5 Group CP 515.2.6 Group DP 515.2.7 Group EP 525.2.8 Group FP 525.2.9 Group GP 525.2.10 Group HP 525.2.11 Group JP 525.2.12 Group KP 536 Quality assessmen
26、t procedures 536.1 Qualification approval testing 536.1.1 Method 1 536.1.2 Method 2 536.2 Quality conformance inspection 536.2.1 Lot-by-lot tests 536.2.2 Periodic tests 546.3 Delayed delivery, re-inspection 54Annex A (normative) Mixed industrial gastestprocedure 56Annex B (normative) Mechanical test
27、s 60Annex C (normative) Microsection 61PageAnnex ZA (normative) Normative references to international publications with their corresponding Europeanpublications 62Figure 1 Connectors with latch blocks and latches 9Figure 2 Connectors with screw locks and jack-screws 9Figure 3 Contact arrangement for
28、 fixed and free connectors 11Figure 4 Straight fixed connector with male contacts and latch blocks Style A 12Figure 5 Straight fixed connector with female contacts and latch blocks Style B 13Figure 6 Straight fixed connector with male contacts and male screw locks Style C 14Figure 7 Straight fixed c
29、onnector with female contacts and female screw locks Style D 16Figure 8 Right-angle fixed connector with male contacts and latch blocks Style E 18Figure 9 Right-angle fixed connector with female contacts and latch blocks Style G 19Figure 10 Right-angle fixed connector with male contacts and male scr
30、ew locks Style I 21Figure 11 Right-angle fixed connector with female contacts and female screw locks Style K 23Figure 12 Right-angle fixed connectors with board locks Styles F, H, J and L 24Figure 13 Free connector with male contacts and latching backshell Style M 25Figure 14 Free connector with fem
31、ale contacts and latching backshell Style N 27Figure 15 Free connector with male contacts and male jack-screw backshell Style O 28Figure 16 Free connector with female contacts and female jack-screw backshell Style P 30Figure 17 Insulation displacement connection 31Figure 18 Accessories 32Figure 19 S
32、traight fixed connector with male contacts Styles A and C 33BS EN 61076-3-101:1997EN 61076-3-101:1997 (E)Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 27/10/2010 07:31, Uncontrolled Copy, (c) BSI4 BSI 2010PageFigure 20 Right-angle fixed connector with male contacts Styles E, F, I and J 35Fi
33、gure 21 Straight fixed connector with female contacts Style B and D 37Figure 22 Right-angle fixed connector with female contacts Styles G, H, K and L 39Figure 23 Panel cut-out for connectors with latch blocks Styles A, B, E, F, G, H, Q and R 40Figure 24 Panel cut-out for connectors with screw locks
34、Styles C, D, I, J, K, L, S and T 41Figure 25 Gauges for female contacts 43Figure 26 Receptacle 44Figure 27 Contact resistance circuit 45Figure A.1 Test chamber zone configuration 59Figure A.2 Control coupon placement 59Figure A.3 Environmental test chamber 60Table 1 Contact positioning 10Table 2 Dim
35、ensions for style A 12Table 3 Dimensions for style B 14Table 4 Dimensions for style C 15Table 5 Dimensions for style D 17Table 6 Dimensions for style E 18Table 7 Dimensions for style G 20Table 8 Dimensions for style I 22Table 9 Dimensions for style K 24Table 10 Dimensions for style M 26Table 11 Dime
36、nsions for style N 28Table 12 Dimensions for style O 29Table 13 Dimensions for style P 31Table 14 Dimensions for straight fixed connector with male contacts 34Table 15 Dimensions for right-angle fixed connector with male contacts 36Table 16 Dimensions for straight fixed connector with female contact
37、s 38Table 17 Dimensions for right-angle fixed board connector with female contacts 40Table 18 Dimensions for panel cut-out for connectors with latch blocks 41Table 19 Dimensions for panel cut-out for connectors with screw locks 42PageTable 20 Insertion and withdrawal forces 46Table 21 Number of spec
38、imens 46Table 22 Number of specimens and permitted defectives 53Table 23 Lot-by-lot tests 54Table 24 Periodic tests 54Table 25 Re-inspection of delayed delivery 55Table A.1 Humidity, temperature and concentration adjustment 58Table B.1 Contact resistance values 61BS EN 61076-3-101:1997EN 61076-3-101
39、:1997 (E)Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 27/10/2010 07:31, Uncontrolled Copy, (c) BSI BSI 2010 51 General data1.1 Recommended method of mountingA complete connector which can have the fixed connector mounted on a printed board and/or panel-mounted. The fixed connector can have
40、 male or female contacts and be soldered or press-in terminated to the printed board.1.2 Ratings and characteristicsIEC SC 48B/TC 48: Connectors/Electromechanical components and mechanical structures to electronic equipment.QC 480201XX0002Electronic components of assessed qualityDetail specification
41、 in accordance with IEC 61076-1Connectors for printed boards, panel mounting, and cable-to-board applicationsRight-angle fixed connector with female contacts and latch blocksFree connectors with male contacts and latchesTrapezoidal shaped 10to120 pole shielded connector. Straight and right-angle fix
42、ed and free connectors. Fixed is mounted on printed boards. Free connectors terminated via insulation displacement.Performance level: 1Assessment level: GCombination of performance and assessment levels: 1GStraight fixed connector with femalecontacts and screw locksFree connector with male contacts
43、and jack-screwsRated voltage:Current rating:Insulation resistance:Climatic category:Printed board thickness:Contact spacing:Minimum/maximumnumber of contacts:250 V a.c.1 A at 30 C (maximum temperature rise) (50% energized)1 G7 minimum55/100/211,6mm (0,062 in)2,4mm (0,093 in)3,2mm (0,125 in)1,27mm 2,
44、54mm (0,050 in 0,100 in)10min. to 120max.Information on the availability of components qualified according to this detail specification is given in the qualified products list (QPL).BS EN 61076-3-101:1997EN 61076-3-101:1997 (E)Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 27/10/2010 07:31,
45、Uncontrolled Copy, (c) BSI6 BSI 20101.3 Reference documentsIEC 60050(581):1978, International Electrotechnical Vocabulary (IEV) Chapter 581: Electromechanical components for electronic equipment. IEC 60326-2:1990, Printed boards Part 2: Test methods. IEC 60352-4:1994, Solderless connections Part 4:
46、Solderless non-accessible insulation displacement connections General requirements, test methods and practical guidance. IEC 60410:1973, Sampling plans and procedures for inspection by attributes. IEC 60512, Electromechanical components for electronic equipment; basic testing procedures and measurin
47、g methods. IEC 60512-1:1994, Electromechanical components for electronic equipment; basic testing procedures and measuring methods Part 1: General. IEC 60512-2:1985, Electromechanical components for electronic equipment; basic testing procedures and measuring methods Part 2: General examination, ele
48、ctrical continuity and contact resistance tests, insulation tests and voltage stress tests. IEC 60512-3:1976, Electromechanical components for electronic equipment; basic testing procedures and measuring methods Part 3: Current-carrying capacity tests. IEC 60512-4:1976, Electromechanical components
49、for electronic equipment; basic testing procedures and measuring methods Part 4: Dynamic stress tests. IEC 60512-5:1992, Electromechanical components for electronic equipment; basic testing procedures and measuring methods Part 5: Impact tests (free components), static load tests (fixed components), endurance tests and overload tests. IEC 60512-7:1993, Electromechanical c