1、BRITISH STANDARD BS EN 61169-33:1997 IEC 1169-33: 1996 QC 222800:1996 Radio-frequency connectors Part 33: Sectional specification for series BMA r.f.connectors The European Standard EN 61169-33:1997 has the status of a British Standard ICS 33.120.30BSEN 61169-33:1997 This British Standard, having be
2、en prepared under the direction of the Electrotechnical Sector Board, was published under the authority of the Standards Board and comes into effect on 15 July 1997 BSI 07-1999 ISBN 0 580 27754 2 National foreword This British Standard is the English language version of EN 61169-33:1997. It is ident
3、ical with IEC 1169-33:1996. This standard is a harmonized specification within the IEC quality assessment system for electronic components (IECQ). In the IECQ System, this specification is numbered QC222800. The UK participation in its preparation was entrusted by Technical Committee EPL/46, Cables,
4、 wires, waveguides, RF connectors and accessories for communication and signalling, to Subcommittee EPL/46/2, RF connectors and waveguides, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpre
5、tation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards whi
6、ch implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not
7、purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside fro
8、nt cover, pages i and ii, theEN title page, pages 2 to 22 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date Comment
9、sBSEN 61169-33:1997 BSI 07-1999 i Contents Page National foreword Inside front cover Foreword 2 Text of EN 61169-33 3ii blankEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 61169-33 May 1997 ICS 33.120.30 Descriptors: Electronic components, R.F.connectors, series BMA English version Radio-frequ
10、ency connectors Part 33: Sectional specification for series BMA r.f. connectors (IEC 1169-33:1996) Connecteurs pour frquences radiolectriques Partie 33: Spcification intermdiaire pour les connecteurs de type BMA h.f. (CEI 1169-33:1996) Hochfrequenz-Steckverbinder Teil 33: Rahmenspezifikation fr HF-S
11、teckverbinder der Baureihe BMA (IEC 1169-33:1996) This European Standard was approved by CENELEC on 1997-03-11. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any
12、 alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made
13、 by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Icelan
14、d, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and UnitedKingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Sta
15、ssart 35, B-1050 Brussels 1997 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61169-33:1997 EEN61169-33:1997 BSI 07-1999 2 Foreword The text of the International Standard IEC 1169-33:1996, prepared by SC 46D, RF connectors, of IEC
16、TC 46, Cables, wires, waveguides, R.F.connectors, and accessories for communication and signalling, was submitted to the Unique Acceptance Procedure and was approved by CENELEC as EN 61169-33 on 1997-03-11 without any modification. The following dates were fixed: This part 33 of EN 61169 is to be us
17、ed in conjunction with EN 61169-1:1994 and its amendment A1:1996. Endorsement notice The text of the International Standard IEC 1169-33:1996 was approved by CENELEC as a European Standard without any modification. Contents Page Foreword 2 Introduction 3 1 Scope 3 2 Mating face and gauge information
18、3 2.1 Dimensions High-performance connectors Grade 1 3 2.2 Gauges 5 2.3 Dimensions Standard test connectors Grade 0 6 2.4 General requirements for connector mounting in modules and on panels 8 3 Quality assessment procedure 9 3.1 General 9 3.2 Ratings and characteristics (see clause 6 of IEC 1169-1/
19、QC 220000) 9 3.3 Test schedule and inspection requirements Acceptance tests 11 3.4 Instructions for preparation of detailspecifications 13 3.5 Blank detail specification pro forma for series BMA connectors 15 Figure 1a 4 Figure 1b 4 Figure 2 Gauge pins for center contact ofsocketconnectors 5 Figure
20、3 Gauge for outer contact of socket connectors 5 Figure 4 Female center contact 6 Figure 5 Male center contact 7 Table 1 4 Table 2 5 Table 3 6 Table 4 7 Table 5 Standard test connectors, plug (Grade 0) 8 Table 6 Rating and characteristics 9 Table 7 Acceptance tests 11 Table 8 Periodic tests 12 lates
21、t date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 1998-03-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 1998-03-01EN61169-33:1997 BSI 07-1999 3 Introduction The c
22、onnector interface specified by this part of IEC 1169 includes patented matter which is contained in a United States patent assigned to the manufacturer. The International Electrotechnical Commission calls attention to the fact that certain interface dimensions and features of the BMA connector are
23、the subject of the United States patent no. 4,426,127 now issued and owned by M/A-Com Omni Spectra, Inc. The IEC takes no position with respect to patent validity. M/A-Com Omni Spectra has assured the IEC that it is willing to grant a licence under these patents on reasonable and non-discriminatory
24、terms and conditions to anyone wishing to obtain such a licence. M/A-Com Omni Spectras undertakings (policy letter on licensing, the licence offer, and the form of licence) in this respect are on file with the International Electrotechnical Commission and are available for inspection by all interest
25、ed parties at the IEC Central Office. The licence details may be obtained from the legal department of M/A-Com Omni Spectra, Incorporated whose address is: 1 Scope Series BMA connectors have a characteristic impedance of 50 7 and are normally used for blind-entry low-power microwave applications in
26、conjunction with flexible and semi-rigid cables having a dielectric diameter of up to 3,00mm. The connectors are usable up to a frequency of at least 18GHz. This sectional specification provides information and rules for the preparation of detail specifications for series BMA r.f.connectors together
27、 with the pro forma blank detail specification (BDS). It also prescribes mating face dimensions for general purpose connectors, dimensional details of standard test connectors grade 0, gauging information and tests selected from QC 220000 (IEC 1169-1) applicable to all detail specifications relating
28、 to series BMA connectors. This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H 2 Mating face and gauge Information 2.1 Dimensions High-performa
29、nce connectors Grade 1 Inch dimensions are original dimensions. All undimensioned pictorial configurations are for reference purposes only. 21 Continental Boulevard Merrimack, NH 03054 U.S.A.EN61169-33:1997 4 BSI 07-1999 Table 1 Figure 1a Figure 1b Reference mm in Notes Min. Max. Min. Max. A 0,38 0,
30、51 0,015 0,020 Chamfer B 2,845 0,112 4, 6 D 4,090 nominal 0,161 nominal Diameter E 2 Diameter F 4,880 nominal 0,192 nominal Diameter G 5,309 5,359 0,209 0,211 Diameter H 7,620 nominal 0,300 nominal Diameter K 3,048 3,225 0,120 0,127 3 M 2,921 0,115 P 5,055 0,199 Q 5,029 0,198 S 7,370 0,290 Diameter
31、T 5,720 0,225 Diameter U 4 Diameter V 0,380 0,015 Diameter W 0,9017 0,9398 0,0355 0,0370 Diameter X 3,252 3,429 0,128 0,135 Z 2,159 2,413 0,085 0,095 AA 1,346 0,053 1 Reference plane, mechanical and electrical. 2 Bore diameter closed to meet electrical and mechanical requirements when mated with a 0
32、,0355/0,0370 in (0,9017/0,9398 mm) diameter. 3 With spring finger bottomed. 4 To meet electrical and mechanical requirements. 5 Design and location of the sealing feature is optional but shall ensure the environmental performance requirements are met with up to 0,015 in (0,38 mm) interface separatio
33、n. 6 Location of point of electrical and mechanical contact from the reference plane.EN61169-33:1997 BSI 07-1999 5 2.2 Gauges Inch dimensions are original dimensions. All undimensioned pictorial configurations are for reference purposes only. 2.2.1 Gauges for female center contact Table 2 Test proce
34、dure Gauge A shall be inserted once only into the female center contact. This is a sizing operation. After this, gauge B shall be inserted into the female center contact. The contact shall support the mass of the gauge in a vertical downward position. NOTEThe minimum diameter of gauge A corresponds
35、to the maximum diameter of a male contact. 2.2.2 Gauges for female outer contacts Figure 2 Gauge pins for center contact of socket connectors Ref. Gauge A Maximum material for sizing purposes Gauge B Minimum material for sizing purposes Mass of gauge: 28 g min. mm in mm in Min. Max. Min. Max. Min. M
36、ax. Min. Max. A 0,9398 0,9448 0,0370 0,0372 0,8967 0,9017 0,0353 0,0355 B 0,762 1,143 0,0300 0,045 1,270 1,905 0,050 0,0750 C 0,380 0,015 Material: polished steel. Surface roughness Ra: 0,4 4m (16 4in) maximum. Figure 3 Gauge for outer contact of socket connectors (for dimensions seeTable 3)EN61169-
37、33:1997 6 BSI 07-1999 Table 3 Test procedure The gauge C shall be placed once inside the outer contact. This is a sizing operation. The gauge D is placed inside the outer contact. The retention force of the gauge shall be 0,56Nminimum 2.3 Dimensions Standard test connectors Grade 0 Inch dimensions a
38、re original dimensions. 2.3.1 Socket (female contact) Ref. Gauge C Maximum material for sizing purposes Gauge D Minimum material for measurement ofgaugeretentionforce Mass of gauge: 56 g min. mm in mm in Min. Max. Min. Max. Min. Max. Min. Max. A? 5,3594 5,3644 0,2110 0,2112 5,3036 5,3086 0,2088 0,20
39、90 B? 4,9124 4,9352 0,1934 0,1943 4,8133 4,8234 0,1895 0,1899 C? 2,540 4,064 0,100 0,160 2,540 4,064 0,100 0,160 D 5,3086 5,6616 0,2090 0,2229 5,3086 5,3644 0,2090 0,2112 E 11 30 9 30 Material: polished steel. Surface roughness Ra: 0,4 4m (16 4in) maximum. Figure 4 Female center contactEN61169-33:19
40、97 BSI 07-1999 7 Table 4 2.3.2 Plug (male contact) Reference mm in Notes Min. Max. Min. Max. a 5,029 0,1980 5 b 2,921 0,1150 c 2,540 2,794 0,1000 0,1100 d 3,125 3,225 0,1230 0,1270 5 e 4,064 4,102 0,1600 0,1615 4 f? 4 g? 5,715 0,2250 4 h? 7,366 0,2900 j? 0,9525 0,9779 0,0375 0,0385 3 et 4 k 0,1778 0
41、,2286 0,0070 0,0090 6 m? 1,778 nominal 0,070 nominal 2 n 1,270 nominal 0,070 nominal 2 For dimensions not included in this table, see2.1. 1 Reference plane, mechanical and electrical. 2 Chosen to give the required performance 50 0,5 7. The given nominal diameter in the table is on the assumption of
42、the air dielectric having a dielectric constant of 1,00. 3 Diameter before slotting and closing. 4 On MMC diameters e, f, g and j, shall be on or capable of taking up a common axis. 5 With spring fingers bottomed. 6 Four slots. Figure 5 Male center contactEN61169-33:1997 8 BSI 07-1999 Table 5 Standa
43、rd test connectors, plug (Grade 0) 2.4 General requirements for connector mounting in modules and on panels 2.4.1 Limits of permissible connector radial misalignment and axial misalignment When designing the mounting arrangements for series BMA connectors, it is essential that the disposition of ind
44、ividual pairs of connectors and their engagement is controlled within the following general limiting conditions. 2.4.1.1 Radial misalignment The radial misalignment between engaging connectors refers to the concentricity error between diameterg of the plug and diameter f of the socket at the beginni
45、ng and during the engagement (see2.1 for dimensionsg and f of the plug and socket. A rigidly mounted plug and socket shall accept a radial misalignment within at the beginning and during the engagement. A rigidly mounted plug and float-mounted socket shall accept a radial misalignment within at the
46、beginning of the engagement. During the engagement, the floating connector shall be able to align itself with the rigidly mounted connector within 2.4.1.2 Axial misalignment a) Rigidly mounted plug and socket To maintain the electrical and environmental performance, the connector reference planes sh
47、ould be within 0,015 in (0,38mm). Further separation up to 0,030 in (0,76mm) will degrade electrical performance and negate the environmental performance. b) Rigidly mounted plug and float-mounted socket The float mounting allows a total of 0,060 in (1,52mm) axial travel. The mounting arrangements s
48、hould, however, ensure a minimum length of travel of 0,010 in (0,26mm) 0,030 in (0,76mm) preferred to ensure that full length of engagement is maintained under operational conditions. Reference mm in Notes min. max. min. max. a 5,055 0,199 b 3,252 3,352 0,128 0,132 d 2,159 2,413 0,0850 0,095 e? 7,62
49、 nominal 0,300 nominal f? 5,309 5,359 0,209 0,2110 4 g? 4,877 nominal 0,192 nominal h? 4,064 0,102 0,1600 0,1615 4 j? 1,778 nominal 0,700 nominal 3 and 4 k? 0,9017 0,9347 0,0355 0,0368 4 l? 0,2540 nominal 0,0100 nominal For dimensions not included in this table, see2.1. 1 Reference plane, mechanical and electrical. 2 Surface roughness 0,8 4m (32 4in minimum). 3 Chosen to give the required performanc