1、BRITISH STANDARDBS EN 61300-2-18:2005Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-18: Tests Dry heat High temperature enduranceThe European Standard EN 61300-2-18:2005 has the status of a British StandardICS 33.180.20g49g50g3g38g50g51g60g44g
2、49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58Licensed Copy: Wang Bin, na, Thu Apr 20 03:15:04 BST 2006, Uncontrolled Copy, (c) BSIBS EN 61300-2-18:2005This British Stand
3、ard was published under the authority of the Standards Policy and Strategy Committee on 23 January 2006 BSI 23 January 2006ISBN 0 580 47717 7National forewordThis British Standard is the official English language version of EN 61300-2-18:2005. It is identical with IEC 61300-2-18:2005. It supersedes
4、BS EN 61300-2-18:1997 which is withdrawn.The UK participation in its preparation was entrusted by Technical Committee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnecting devices and passive components, which has the responsibility to: A list of organizations represented on th
5、is subcommittee can be obtained on request to its secretary.Cross-referencesThe British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by usi
6、ng the “Search” facility of the BSI Electronic Catalogue or of British Standards Online.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity fr
7、om legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related international and European developments and promulgate them in the UK.
8、Summary of pagesThis document comprises a front cover, an inside front cover, the EN title page, pages 2 to 8, an inside back cover and a back cover.The BSI copyright notice displayed in this document indicates when the document was last issued.Amendments issued since publicationAmd. No. Date Commen
9、tsLicensed Copy: Wang Bin, na, Thu Apr 20 03:15:04 BST 2006, Uncontrolled Copy, (c) BSIEUROPEAN STANDARD EN 61300-2-18 NORME EUROPENNE EUROPISCHE NORM September 2005 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr
10、 Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61300-2-18:2005 E ICS 33.180.20 Supersedes EN 61300-2-18:1997English version Fibre optic in
11、terconnecting devices and passive components Basic test and measurement procedures Part 2-18: Tests Dry heat High temperature endurance (IEC 61300-2-18:2005) Dispositifs dinterconnexion et composants passifs fibres optiques - Mthodes fondamentales dessais et de mesures Partie 2-18: Essais Chaleur sc
12、he Rsistance haute temprature (CEI 61300-2-18:2005) Lichtwellenleiter-Verbindungselemente und passive Bauteile Grundlegende Prf- und Messverfahren Teil 2-18: Prfungen Trockene Wrme, Dauerprfung (IEC 61300-2-18:2005) This European Standard was approved by CENELEC on 2005-08-01. CENELEC members are bo
13、und to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the
14、Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the sam
15、e status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portug
16、al, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Licensed Copy: Wang Bin, na, Thu Apr 20 03:15:04 BST 2006, Uncontrolled Copy, (c) BSIForeword The text of document 86B/2136/FDIS, future edition 2 of IEC 61300-2-18, prepared by SC 86B, Fibre optic interconnecting devices and pas
17、sive components, of IEC TC 86, Fibre optics, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61300-2-18 on 2005-08-01. This European Standard supersedes EN 61300-2-18:1997. Specific technical changes in this European Standard involve simplification of the combination
18、 of temperature and exposure time. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2006-05-01 latest date by which the national standards conflicting with the EN have to be wi
19、thdrawn (dow) 2008-08-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61300-2-18:2005 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for th
20、e standards indicated: IEC 61300-1 NOTE Harmonized as EN 61300-1:2003 (not modified). IEC 61300-2-22 NOTE Harmonized as EN 61300-2-22:1995 (not modified). _ EN 61300-2-18:2005 2 Licensed Copy: Wang Bin, na, Thu Apr 20 03:15:04 BST 2006, Uncontrolled Copy, (c) BSI 3 CONTENTS 1 Scope 4 2 Normative ref
21、erences .4 3 General description 4 4 Apparatus 5 4.1 Chamber .5 4.2 Optical source and detector.5 5 Procedure 5 5.1 Preconditioning .5 5.2 Initial examinations and measurements5 5.3 Conditioning 5 5.4 Recovery.65.5 Final examinations and measurements 6 6 Severity6 7 Details to be specified 6 Bibliog
22、raphy .7 Annex ZA (normative) Normative references to international publications with theircorresponding European publications.8EN 61300-2-18:2005Licensed Copy: Wang Bin, na, Thu Apr 20 03:15:04 BST 2006, Uncontrolled Copy, (c) BSIFIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS BASIC TEST
23、 AND MEASUREMENT PROCEDURES Part 2-18: Tests Dry heat High temperature endurance 1 Scope This part of IEC 61300 details a procedure to determine the suitability of a fibre optic device or closure to withstand the environmental condition of extended high temperature that may occur during operation, s
24、torage and/or transport. The test is intended to indicate the performance of such devices when exposed to heat of constant temperature over a given period. In general terms, this test provides a high temperature to induce potential failures due to softening and expansions. This procedure does not as
25、sess the ability of a device to operate during temperature variations; in this case, IEC 61300-2-22 would be used. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated refer
26、ences, the latest edition of the referenced document (including any amendments) applies. IEC 60068-2-2, Environmental testing Part 2: Tests Tests B: Dry heat IEC 61300-3-1, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-1: Examinations and mea
27、surements Visual examination IEC 61300-3-3, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-3: Examinations and measurements Active monitoring of changes in attenuation and return loss IEC 61300-3-4, Fibre optic interconnecting devices and pass
28、ive components Basic test and measurement procedures Part 3-4: Examinations and measurements Attenuation 3 General description This procedure is conducted in accordance with IEC 60068-2-2, test Bb. The specimen is placed in an environmental chamber and subjected to a dry heat environment, which is m
29、aintained at a given temperature for a specified duration, as defined in the relevant specification. If required, the attenuation of the specimen is monitored throughout the duration of the test. EN 61300-2-18:2005 4 Licensed Copy: Wang Bin, na, Thu Apr 20 03:15:04 BST 2006, Uncontrolled Copy, (c) B
30、SI4 Apparatus 4.1 Chamber The apparatus shall consist of an environmental chamber in accordance with IEC 60068-2-2, test Bb. The chamber shall be capable of housing the specimen and of allowing access for measurement during conditioning, if required. It shall also be capable of maintaining the speci
31、fied temperature and humidity within the specified tolerances. Forced air circulation may be used to maintain homogeneous conditions. Care shall be taken to ensure that the specimen is not directly exposed to the heating or cooling elements. 4.2 Optical source and detector The optical source and det
32、ector used to measure changes in attenuation shall comply with those specified in IEC 61300-3-4. NOTE A device to record attenuation over time (X, t) should be used where the optical detector does not have the capability to monitor continuously. 5 Procedure Conduct the procedure in accordance with I
33、EC 60068-2-2, test Bb. Unless otherwise stated: if the component construction includes optical leads, include 1,5 m of cable in the climatic chamber for each port monitored during the test; If optical measurements are requested during the test, these measurements shall be performed at a maximum inte
34、rval of 1 h. 5.1 Preconditioning Clean the mechanical and optical alignment parts of the specimen according to the manufacturers instructions. Unless otherwise stated, maintain the specimen under standard atmospheric condition (room temperature condition) for 2 h minimum. 5.2 Initial examinations an
35、d measurements If specified, perform initial examinations and measurements as required by the relevant specification. 5.3 Conditioning 5.3.1 Set the chamber and the specimen to standard atmospheric conditions. Place the specimen in the chamber in its normal operating position including hook-ups to p
36、eripheral equipment (when required). 5.3.2 Adjust the chamber temperature and humidity to the specified severity. The rate of change of temperature shall not exceed 1 C/min, averaged over a maximum period of 5 min. Allow the specimen to reach temperature stability and maintain the temperature for th
37、e duration specified. 5.3.3 At the completion of the test, allow the specimen to remain in the chamber while the temperature is gradually reduced to standard atmospheric conditions. EN 61300-2-18:2005 5 Licensed Copy: Wang Bin, na, Thu Apr 20 03:15:04 BST 2006, Uncontrolled Copy, (c) BSI5.3.4 Where
38、optical measurements are required during the test, measurements shall be made at a maximum interval of 1 h. Measurements shall be made in accordance with IEC 61300-3-3 regarding monitoring change in attenuation and return loss. 5.4 Recovery Allow the specimen to remain under standard atmospheric con
39、ditions for a period of greater than 2 h. 5.5 Final examinations and measurements On completion of the test, remove all fixtures and make final measurements, as defined by the relevant specification, to ensure that there is no permanent damage to the specimen. The results of the final measurement sh
40、all be within the limit established in the relevant specification. Unless otherwise specified, visually examine the specimen in accordance with IEC 61300-3-1. Check for evidence of any degradation in the specimen. This may include, for example broken, loose or damaged parts or accessories; breaking
41、or damage to the cable jacket, seals, strain relief, or fibres; displaced, bent, or broken parts. 6 Severity The severity consists of the combination of the temperature and exposure time. The severity shall be specified in the relevant specification. One of the severities indicated in Table 1 shall
42、be specified for this procedure: Table 1 Severities Temperature C Duration of exposure h + 60 +70 +85 96 7 Details to be specified The following details, as applicable, shall be specified in the relevant specification: temperature; duration of exposure; initial examinations and measurements and perf
43、ormance requirements; examinations and measurements during test and performance requirements; final examinations and measurements and performance requirements; deviations from test procedure; additional pass/fail criteria. EN 61300-2-18:2005 6 Licensed Copy: Wang Bin, na, Thu Apr 20 03:15:04 BST 200
44、6, Uncontrolled Copy, (c) BSIBibliography IEC 61300-1, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 1: General and guidance IEC 61300-2-22, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2
45、-22: Tests Change of temperature _ EN 61300-2-18:2005 7 Licensed Copy: Wang Bin, na, Thu Apr 20 03:15:04 BST 2006, Uncontrolled Copy, (c) BSIAnnex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are i
46、ndispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE Where an international publication has been modified by common modifications, indica
47、ted by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60068-2-2 - 1)Basic environmental testing procedures Part 2: Tests - Tests B: Dry heat EN 60068-2-2 1993 2)IEC 61300-3-1 - 1)Fibre optic interconnecting devices and passive components - Basic test and measurement procedu
48、res Part 3-1: Examinations and measurements - Visual examination EN 61300-3-1 1997 2)IEC 61300-3-3 - 1)Part 3-3: Examinations and measurements - Active monitoring of changes in attenuation and return loss EN 61300-3-3 2003 2)IEC 61300-3-4 - 1)Part 3-4: Examinations and measurements - Attenuation EN
49、61300-3-4 2001 2)1)Undated reference. 2)Valid edition at date of issue. EN 61300-2-18:2005 8 Licensed Copy: Wang Bin, na, Thu Apr 20 03:15:04 BST 2006, Uncontrolled Copy, (c) BSIblankLicensed Copy: Wang Bin, na, Thu Apr 20 03:15:04 BST 2006, Uncontrolled Copy, (c) BSIBS EN 61300-2-18:2005BSI389 Chiswick High RoadLondonW4 4ALBSI British Standards InstitutionBSI is the independent national body responsible for preparing British S
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1