1、Electrolyte and water for vented lead acid accumulatorsPart 1: Requirements for electrolyteBS EN 62877-1:2016BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06National forewordThis British Standard is the UK implementation of EN 62877-1:2016. It isidentical to IEC 6287
2、7-1:2016.The UK participation in its preparation was entrusted to TechnicalCommittee PEL/21, Secondary cells and batteries.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa co
3、ntract. Users are responsible for its correct application. The British Standards Institution 2016.Published by BSI Standards Limited 2016ISBN 978 0 580 87297 6ICS 29.220.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the au
4、thority of theStandards Policy and Strategy Committee on 31 December 2016.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 62877-1:2016EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 62877-1 May 2016 ICS 29.220.20 English Version Electrolyte and water for ve
5、nted lead acid accumulators - Part 1: Requirements for electrolyte (IEC 62877-1:2016) Electrolyte et eau pour accumulateurs plomb-acide ouverts - Partie 1: Exigences pour llectrolyte (IEC 62877-1:2016) Elektrolyte und Wasser fr geschlossene Blei-Sure-Batterien - Teil 1: Anforderungen an Elektrolyte
6、(IEC 62877-1:2016) This European Standard was approved by CENELEC on 2016-03-02. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists a
7、nd bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under
8、 the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Esto
9、nia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee
10、for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC M
11、embers. Ref. No. EN 62877-1:2016 E BS EN 62877-1:2016EN 62877-1:2016 2 European foreword The text of document 21/874/FDIS, future edition 1 of IEC 62877-1, prepared by IEC/TC 21 “Secondary cells and batteries“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 62877-1:2016.
12、 The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2016-12-02 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2019-03-0
13、2 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 62877-1:2016 was appro
14、ved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following note has to be added for the standard indicated : IEC 62485-3 NOTE Harmonized as EN 62485-3. BS EN 62877-1:2016EN 62877-1:2016 3 Annex ZA (normative) Normative references to inter
15、national publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition o
16、f the referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is ava
17、ilable here: www.cenelec.eu. Publication Year Title EN/HD Year IEC 62877-2 - Electrolyte and water for vented lead acid accumulators - Part 2: Requirements for water EN 62877-2 - BS EN 62877-1:2016 2 IEC 62877-1:2016 IEC 2016 CONTENTS FOREWORD . 3 1 Scope 5 2 Normative references. 5 3 Terms and defi
18、nitions 5 4 Preparation of electrolyte for lead-acid accumulators 7 5 Physical properties of diluted sulfuric acid as electrolyte . 7 5.1 Dependence of acid density on temperature 7 5.2 Relationship of electrolyte density on the content of sulfuric acid at 25 C 8 5.3 Electrolyte density compared to
19、the state of discharge . 8 6 Requirements of sulfuric acid used as electrolyte . 8 6.1 Impurities of sulfuric acid of higher concentration degrees . 8 6.2 Impurities of filling acid 8 6.3 Impurities of operating electrolyte 9 7 Storage of electrolyte . 10 8 Remedy in the event of damage due to elect
20、rolyte 10 Bibliography . 12 Table 1 Correction of density from measuring temperature to reference/specified temperature 7 Table 2 Acid density versus percentage of sulphuric acid at 25 C 8 Table 3 Maximum allowed impurities of diluted sulfuric acid as filling electrolyte for lead-acid batteries in t
21、he density range 1,30 kg/l . 9 Table 4 Maximum allowed impurity of diluted acid as operating electrolyte for lead-acid batteries in the density range 1,30 kg/l . 10 BS EN 62877-1:2016IEC 62877-1:2016 IEC 2016 3 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ ELECTROLYTE AND WATER FOR VENTED LEAD ACID AC
22、CUMULATORS Part 1: Requirements for electrolyte FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on
23、 all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Pu
24、blication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation.
25、 IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of
26、 opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made
27、 to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transpar
28、ently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any attestation of conformity. Independent cert
29、ification bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All users should ensure that they have the latest edition of this publication. 7) No liability sh
30、all attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including le
31、gal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this pu
32、blication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 62877-1 has been prepared by IEC technical committee
33、21: Secondary cells and batteries. The text of this standard is based on the following documents: FDIS Report on voting 21/874/FDIS 21/881/RVD Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. This publication has been
34、 drafted in accordance with the ISO/IEC Directives, Part 2. BS EN 62877-1:2016 4 IEC 62877-1:2016 IEC 2016 A list of all parts of the IEC 62877 series can be found, under the general title Electrolyte and water for vented lead acid accumulators, on the IEC website. The committee has decided that the
35、 contents of this publication will remain unchanged until the stability date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended. BS EN 628
36、77-1:2016IEC 62877-1:2016 IEC 2016 5 ELECTROLYTE AND WATER FOR VENTED LEAD ACID ACCUMULATORS Part 1: Requirements for electrolyte 1 Scope This part of IEC 62877 applies to electrolyte and their components used for filling vented lead-acid batteries, for example dry charged cells or batteries, and fo
37、r electrolyte replacement or electrolyte density adjustment of batteries in operation. This international standard defines the composition, purity and properties of electrolyte to be applied where specific instructions from the battery manufacturer are not available. 2 Normative references The follo
38、wing documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 62877-2, Ele
39、ctrolyte and water for vented lead acid accumulators Part 2: Requirements for water 3 Terms and definitions For the purposes of this document, the following terms and definitions apply 3.1 electrolyte diluted sulfuric acid (H2SO4) for lead-acid accumulators Note 1 to entry: The electrolyte is prepar
40、ed by mixing concentrated sulfuric acid or sulfuric acid with high density of d 1,30 kg/l and purified water to achieve the density values specified by the battery manufacturer or specified in standards related to the type and battery design in question for a defined state of charge. Its purity meet
41、 the requirements laid down in Table 3. Note 2 to entry: Concentrated sulfuric acid is a colorless, highly corrosive and etching liquid with a density 1,84 kg/l. 3.2 water purified water (H2O) used for the preparation of electrolyte for batteries and for the replacement (topping up) of water loss in
42、 the operating electrolyte due to decomposition of water by overcharging and evaporation Note 1 to entry: Purified water meet the requirements specified in IEC 62877-2. 3.3 filling electrolyte diluted sulfuric acid to be used for the first filling of batteries or for the replacement of contaminated
43、operating electrolyte BS EN 62877-1:2016 6 IEC 62877-1:2016 IEC 2016 3.4 first filling original filling of a battery carried out by the battery manufacturer or the user in accordance with the applicable manufacturers instructions 3.5 operating electrolyte electrolyte present in the battery following
44、 the first filling Note 1 to entry: The density values and the degree of purity of the operating electrolyte may deviate from the values of the filling electrolyte due to impurity input from replenishment by water and to elution from e.g. separators, active material and electrode grids. 3.6 electrol
45、yte density value for the mass per volume expressed in kg/l Note 1 to entry: The density varies with the batterys state of charge, the electrolyte volume variation due to water loss and the temperature. 3.7 specified density density of the battery to be stated by the battery manufacturer valid at th
46、e maximum electrolyte level (see 3.10 ) at full state of charge of the battery at the reference temperature Note 1 to entry: It is related to the application and design of the battery. 3.8 reference temperature for analytical results reference temperature for analytical results of electrolyte impuri
47、ties which is 25 C 1 C Note 1 to entry: Density values measured at temperatures deviating from this reference temperature are adjusted accordingly. 3.9 measurement of the electrolyte density measurement is carried out by densimeters, in which areometers (hydrometers) are used, or by electronic devic
48、es based on e.g. on ultrasonic measurements Note 1 to entry: The accuracy of the instrument is better than 0,001 kg/l. 3.10 electrolyte level position of the electrolyte surface in the cell/battery, where the recommended tidal movements are indicated by maximum and minimum electrolyte level marks to
49、 assist in water replenishment Note 1 to entry: Water replenishment should take place in a fully charged state to the upper limit, to avoid over topping and electrolyte loss. 3.11 reference temperature value specified by the battery manufacturer for the indication of properties, such as the nominal electrolyte density, the maximum electrolyte level and the nominal capacity of the battery Note 1 to entry: The value of the nominal temperature for the indication of parameters may differ
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1