1、BRITISH STANDARD BS EN ISO 10360-3:2001 Geometrical Products Specifications (GPS) Acceptance and reverification tests for coordinate measuring machines (CMM) Part 3: CMMs with the axis of a rotary table as the fourth axis The European Standard EN ISO 10360-3:2000 has the status of a British Standard
2、 ICS 17.040.30 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBS EN ISO 10360-3:2001 This British Standard, having been prepared under the direction of the Consumer Products and Services Sector Committee, was published under the authority of the Standards Committee and comes i
3、nto effect on 15 October 2001 BSI 08-2001 ISBN 0 580 38407 1 National foreword This British Standard is the official English language version of EN ISO 10360-3:2000. It is identical with ISO 10360-3:2000 The UK participation in its preparation was entrusted by Technical Committee TDW/4, Engineering
4、drawing, metrology, precision measurement and all related documentation, to Subcommittee TDW/4/-/4, Engineers precision measuring equipment, including limits and fits, which has the responsibility to: A list of organizations represented on this Subcommittee can be obtained on request to its secretar
5、y. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards El
6、ectronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to unde
7、rstand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document compris
8、es a front cover, an inside front cover, the EN ISO title page, the EN ISO foreword page, the ISO title page, pages ii to v, a blank page, pages 1 to 12, the Annex ZA page and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issu
9、ed since publication Amd. No. Date CommentsEUROPEANSTANDARD NORMEEUROPENNE EUROPISCHENORM ENISO103603 March2000 ICS17.040.30 Englishversion GeometricalProductSpecifications(GPS)Acceptanceand reverificationtestsforcoordinatemeasuringmachines(CMM) Part3:CMMswiththeaxisofarotarytableasthefourthaxis (IS
10、O103603:2000) Spcificationgometriquedesproduits(GPS)Essaisde rceptionetdevrificationpriodiquedesmachines mesurertridimensionnelles(MMT)Partie3:MMTayant laxederotationdunplateautournantcommequatrime axe(ISO103603:2000) GeometrischeProduktspezifikation(GPS) AnnahmeprfungundBesttigungsprfungfr Koordina
11、tenmessgerte(KMG)Teil3:KMGmitderAchse einesDrehtischesalsvierteAchse(ISO103603:2000) ThisEuropeanStandardwasapprovedbyCENon15March2000. CENmembersareboundtocomplywiththeCEN/CENELECInternalRegulationswhichstipulatetheconditionsforgivingthisEurope an Standardthestatusofanationalstandardwithoutanyalter
12、ation.Uptodatelistsandbibliographicalreferencesconcernings uchnational standardsmaybeobtainedonapplicationtotheCentralSecretariatortoanyCENmember. ThisEuropeanStandardexistsinthreeofficialversions(English,French,German).Aversioninanyotherlanguagemadebytra nslation undertheresponsibilityofaCENmemberi
13、ntoitsownlanguageandnotifiedtotheCentralSecretariathasthesamestatusast heofficial versions. CENmembersarethenationalstandardsbodiesofAustria,Belgium,CzechRepublic,Denmark,Finland,France,Germany,Greece, Iceland,Ireland,Italy,Luxembourg,Netherlands,Norway,Portugal,Spain,Sweden,SwitzerlandandUnitedKing
14、dom. EUROPEANCOMMITTEEFORSTANDARDIZATION COMITEUROPENDENORMALISATION EUROPISCHESKOMITEEFRNORMUNG CentralSecretariat:ruedeStassart,36B1050Brussels 2000CEN Allrightsofexploitationinanyformandbyanymeansreserved worldwideforCENnationalMembers. Ref.No.ENISO103603:2000EENISO103603:20011002:306301OSINE Ref
15、erence number ISO 10360-3:2000(E) INTERNATIONAL STANDARD ISO 10360-3 First edition 2000-03-15 Geometrical Product Specifications (GPS) Acceptance and reverification tests for coordinate measuring machines (CMM) Part 3: CMMs with the axis of a rotary table as the fourth axis Spcification gomtrique de
16、s produits (GPS) Essais de rception et de vrification priodique des machines mesurer tridimensionnelles (MTT) Partie 3: MMT ayant laxe de rotation dun plateau tournant comme quatrime axe ENISO103603:2001 ii ENISO103603:2001 iii Contents Page Foreword.iv Introduction.v 1 Scope 1 2 Normative reference
17、s 1 3 Terms and definitions .1 4 Requirements for metrological characteristics2 4.1 Error of indication2 4.2 Environmental conditions.2 4.3 Rotary table 2 4.4 Stylus system.2 4.5 Operating conditions.2 5 Acceptance test and reverification test.3 5.1 Principles3 5.2 Measuring equipment3 5.3 Procedure
18、 .3 5.4 Obtention of test results .5 6 Compliance with specifications .8 6.1 Acceptance test .8 6.2 Reverification test8 7 Applications .8 7.1 Acceptance test .8 7.2 Reverification test8 7.3 Interim check8 Annex A (informative) Interim check.9 Annex B (informative) Relation to the GPS matrix model.1
19、0 Bibliography12 ENISO103603:2001iv Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body i
20、nterested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechn
21、ical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 3. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Public
22、ation as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this part of ISO 10360 may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such
23、patent rights. International Standard ISO 10360-3 was prepared by Technical Committee ISO/TC 213, Dimensional and geometrical product specifications and verification. ISO 10360 consists of the following parts, under the general title Geometrical Product Specifications (GPS) Acceptance and reverifica
24、tion tests for coordinate measuring machines (CMM): Part 1: Vocabulary Part 2: CMMs used for measuring linear dimensions Part 3: CMMs with the axis of a rotary table as the fourth axis Part 4: CMMs used in scanning measuring mode Part 5: CMMs using multiple stylus probing systems Part 6: Estimation
25、of errors in computing Gaussian associated features Annexes A and B of this part of ISO 10360 are for information only. ENISO103603:2001v Introduction This part of ISO 10360 is a geometrical product specification (GPS) standard and is to be regarded as a general GPS standard (see ISO/TR 14638). It i
26、nfluences link 5 of the chains of standards on size, distance, radius, angle, form, orientation, location, run-out and datums. For more detailed information on the relationship of this part of ISO 13060 to other standards and the GPS matrix model, see annex B. The acceptance test and reverification
27、test of this part of ISO 10360 are applicable to CMMs which use a rotary table for the orientation of a workpiece being measured. The tests specified in this part of ISO 10360 are performed in addition to the size measuring tests according to ISO 10360-2, which are conducted with the rotary table st
28、ationary. They are designed to detect the system measuring errors relative to an axis system fixed to the rotary table. It is normally not useful to isolate the rotary table errors from other sources of machine error. ENISO103603:2001ENISO103603:2001 INTENRATIONAL TSANDADR ISO -063013:(0002E) ISO 00
29、02 All irhgts seredevr 1 Geometrical Product Specifications (GPS) Acceptance and reverification tests for coordinate measuring machines (CMM) Part 3: CMMs with the axis of a rotary table as the fourth axis 1 Scope This part of ISO 10360 specifies the acceptance test which verifies that the performan
30、ce of four-axis coordinate measuring machines (CMM) is in accordance with that stated by the manufacturer. It also specifies the reverification test, which enables the user to reverify the performance of a four-axis CMM periodically. The acceptance test and reverification test described in this part
31、 of ISO 10360 are applicable only to four-axis machines with three axes for measuring workpiece coordinates, plus a rotary table for orienting the workpiece. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of th
32、is part of ISO 10360. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this part of ISO 10360 are encouraged to investigate the possibility of applying the most recent editions of the normative documents
33、indicated below. For undated references, the latest edition of the normative document referred to applies. Members of ISO and IEC maintain registers of currently valid International Standards. ISO 10360-1: 1) , Geometrical Product Specifications (GPS) Acceptance and reverification tests for coordina
34、te measuring machines (CMM) Part 1: Vocabulary. ISO 14253-1:1998, Geometrical Product Specifications (GPS) Inspection by measurement of workpieces and measuring equipment Part 1: Decision rules for proving conformance or non-conformance with specifications. International Vocabulary of Basic and Gene
35、ral Terms in Metrology (VIM). BIPM, IEC, IFCC, ISO, IUPAC, IUPAP, OIML, 2nd edition, 1993. 3 Terms and definitions For the purposes of this part of ISO 10360, the terms and definitions given in ISO 10360-1, ISO 14253-1 and VIM apply. 1) To be published. ENISO103603:20011ISO -063013:(0002E) 2 ISO 000
36、2 All irhgts seredevr 4 Requirements for metrological characteristics 4.1 Error of indication The errors of indication, FR, FT, FA, as defined in ISO 10360-1, for the three four-axis errors shall not exceed the maximum permissible errors, MPE FR ,MP E FT ,MPE FA , as defined in ISO 10360-1, as state
37、d by: the manufacturer, in case of acceptance tests; the user, in case of reverification tests. The errors of indication (FR, FT, FA) and the maximum permissible errors (MPE FR ,M P E FT ,M P E FA ) are expressed in micrometres. 4.2 Environmental conditions Limits to be respected for permissible env
38、ironmental conditions such as temperature conditions, air humidity and vibration at the site of installation that influence the measurements shall be specified by: the manufacturer, in case of acceptance tests; the user, in case of reverification tests. In both cases, the user is free to choose the
39、conditions within the specified limits. 4.3 Rotary table The maximum permissible errors (MPE FR ,MPE FT ,M P E FA ) apply for any permitted loading, location and orientation of the rotary table on the CMM and for any locations of the test spheres on the rotary table within specified limits. 4.4 Styl
40、us system Limits to be respected for the stylus system configuration, to which the stated values of MPE FR ,M P E FT ,M P E FA apply, shall be specified by: the manufacturer, in case of acceptance tests; the user, in case of reverification tests. In both cases, the user is free to choose the stylus
41、system configuration within the specified limits. The form deviation of the stylus tip will influence the measurement results and shall be considered when proving conformance or non-conformance with specifications. 4.5 Operating conditions The CMM shall be operated using the procedures given in the
42、manufacturers operating manual when conducting the tests given in clause 5. Specific areas in this manual to be adhered to are, for example: a) machine start up/warm up cycles; b) stylus system configuration; c) cleaning procedures for stylus tip and reference sphere; d) probing system qualification
43、; e) rotary table set-up and qualification. NOTE The stylus tip and the reference sphere should be cleaned before the probing system qualification so as to leave no residual film which could affect the measuring or test result. ENISO103603:20012ISO -063013:(0002E) ISO 0002 All irhgts seredevr 3 5 Ac
44、ceptance test and reverification test 5.1 Principles The principle of the assessment method is to establish whether the CMM is capable of measuring within the stated maximum permissible errors (MPE FR ,M P E FT ,MP E FA ) by determining the variation of the measured coordinates of the centres of two
45、 test spheres mounted on the rotary table. It is noted that on a perfect four-axis CMM, the location of the measured centres of the test spheres would remain fixed in the workpiece coordinate system while the table is rotated. Each test sphere centre is determined in three directions: radial, tangen
46、tial and axial. The position of each test sphere centre is represented in the workpiece coordinate system on a rotary table. The centre of each test sphere, mounted on a rotary table, is measured in a series of measurements with different angular positions of the rotary table. The errors of indicati
47、on (FR, FT, FA) are calculated separately for each test sphere as the range between the maximum and minimum measurement results for each of the three directions. In the following: acceptance tests are executed according to the manufacturers specifications and procedures; reverification tests are exe
48、cuted according to the users specifications and the manufacturers procedures. 5.2 Measuring equipment 5.2.1 Two test spheres (A and B), with diameters no less than 10 mm and no greater than 30 mm and with certified form. The diameters of the two test spheres, used in these tests as the corresponding input quantities, need not be calibrated since only the centres of the test spheres are used to determine the three four-axis errors. The form of the test spheres must be calibrated since t