1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationGeotechnical investigation and testing Field testingPart 4: Mnard pressuremeter testBS EN ISO 22476-4:2012Copyright European Committee for Standardization Provided by IHS under l
2、icense with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-National forewordThis British Standard is the UK implementation of EN ISO 22476-4:2012. It partially supersedes BS 5930:1999+A2:2010, which is currently being revised in order to remove conflicting mate
3、rial. The tests included in BS 5930:1999 (Clauses 25.7.2.1 and 25.7.4.1, and more generally in clauses 27.7.3, 25.7.5 and 25.7.6) are also provided in this standard. In the meantime, where conflict arises between these documents, the provisions of BS EN ISO 22476-4:2012 take precedence.The UK partic
4、ipation in its preparation was entrusted by Technical Committee B/526, Geotechnics, to Subcommittee B/526/3, Site investigation and ground testing.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the ne
5、cessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2013.Published by BSI Standards Limited 2013ISBN 978 0 580 77220 7ICS 93.020Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard wa
6、s published under the authority of the Standards Policy and Strategy Committee on 31 March 2013.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN ISO 22476-4:2012Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleN
7、o reproduction or networking permitted without license from IHS-,-,-EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN ISO 22476-4 December 2012 ICS 93.020 English Version Geotechnical investigation and testing - Field testing - Part 4: Mnard pressuremeter test (ISO 22476-4:2012) Reconnaissance et
8、 essais gotechniques - Essais en place - Partie 4: Essai au pressiomtre Mnard (ISO 22476-4:2012) Geotechnische Erkundung und Untersuchung - Felduntersuchungen - Teil 4: Pressiometerversuch nach Mnard (ISO 22476-4:2012) This European Standard was approved by CEN on 30 November 2012. CEN members are b
9、ound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the
10、 CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centr
11、e has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania
12、, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 20
13、12 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN ISO 22476-4:2012: EBS EN ISO 22476-4:2012Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitte
14、d without license from IHS-,-,-EN ISO 22476-4:2012 (E) 2 Contents Page Foreword 3BS EN ISO 22476-4:2012Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-EN ISO 22476-4:2012 (E) 3 F
15、oreword This document (EN ISO 22476-4:2012) has been prepared by Technical Committee CEN/TC 341 “Geotechnical Investigation and Testing”, the secretariat of which is held by ELOT, in collaboration with Technical Committee ISO/TC 182 “Geotechnics“. This European Standard shall be given the status of
16、a national standard, either by publication of an identical text or by endorsement, at the latest by June 2013, and conflicting national standards shall be withdrawn at the latest by June 2013. Attention is drawn to the possibility that some of the elements of this document may be the subject of pate
17、nt rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cro
18、atia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
19、the United Kingdom. BS EN ISO 22476-4:2012Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ISO 22476-4:2012(E) ISO 2012 All rights reserved iiiContents Page1 Scope 12 Normative re
20、ferences . 23 Terms, definitions and symbols 23.1 Terms and definitions . 23.2 Symbols . 44 Equipment . 64.1 General description 64.2 Pressuremeter probe 74.3 Pressure and volume control unit (CU) . 114.4 Connecting lines 114.5 Injected liquid . 114.6 Measurement and control . 114.7 Data logger 125
21、Test procedure .125.1 Assembling the parts .125.2 Calibration and corrections 125.3 Pressuremeter pocket and probe placing 125.4 Preparation for testing .135.5 Establishing the loading programme .135.6 Establishing the differential pressure .145.7 Expansion 155.8 Back-filling of the pockets 155.9 Sa
22、fety requirements .156 Test results 166.1 Data sheet and field print-out .166.2 Corrected pressuremeter curve 176.3 Calculated results .177 Reporting .187.1 General .187.2 Field report 187.3 Test report .18Annex A (normative) Geometrical features of pressuremeter probes .20Annex B (normative) Calibr
23、ation and corrections .23Annex C (normative) Placing the pressuremeter probe in the ground 31Annex D (normative) Obtaining pressuremeter parameters .38Annex E (normative) Resolution and uncertainties 46Annex F (normative) Pressuremeter test records .47Bibliography .51BS EN ISO 22476-4:2012Copyright
24、European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-INTERNATIONAL STANDARD ISO 22476-4:2012(E)Geotechnical investigation and testing Field testing Part 4: Mnard pressuremeter test1 ScopeThis p
25、art of ISO 22476 specifies the equipment requirements, execution of and reporting on the Mnard pressuremeter test.NOTE 1 This part of ISO 22476 fulfils the requirements for the Mnard pressurermeter test, as part of the geotechnical investigation and testing according to EN 1997-1 and EN 1997-2.This
26、part of ISO 22476 describes the procedure for conducting a Mnard pressuremeter test in natural soils, treated or untreated fills and in weak rocks, either on land or off-shore.The pressuremeter test results of this part of ISO 22476 are suited to a quantitative determination of ground strength and d
27、eformation parameters. They may yield lithological information. They can also be combined with direct investigation (e.g. sampling according to ISO 22475-1) or compared with other in situ tests (see EN 1997-2:2007, 2.4.1.4(2) P, 4.1 (1) P and 4.2.3(2) P).The Mnard pressuremeter test is performed by
28、the radial expansion of a tricell probe placed in the ground (see Figure 1). During the injection of the liquid volume in the probe, the inflation of the three cells first brings the outer cover of the probe into contact with the pocket wall and then presses on them resulting in a soil displacement.
29、 Pressure applied to and the associated volume expansion of the probe are measured and recorded so as to obtain the stress-strain relationship of the soil as tested.Together with results of investigations with ISO 22475-1 being available, or at least with identification and description of the ground
30、 according to ISO 14688-1 and ISO 14689-1 obtained during the pressuremeter test operations, the test results of this part of ISO 22476 are suited to the quantitative determination of a ground profile, including the Mnard EMmodulus, the Mnard limit pressure pLMand the Mnard creep pressure pfM.This p
31、art of ISO 22476 refers to a probe historically described as the 60 mm G type probe. This part of ISO 22476 applies to test depths limited to 50 m and test pressure limited to 5 MPa.NOTE 2 Mnard pressuremeter tests are carried out with other probe diameters and pocket dimensions such as shown below.
32、Probe Drilling diameter (mm)Designation Diameter (mm) min maxAX 44 46 52BX 58 60 66NX 70/74 74 80Two alternative methods of measurement are provided as follows. Procedure A: data are recorded manually. Procedure B: data are recorded automatically. ISO 2012 All rights reserved 1BS EN ISO 22476-4:2012
33、Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ISO 22476-4:2012(E)2 Normative referencesThe following referenced documents are indispensable for the application of this document
34、. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.ISO 14688-1, Geotechnical investigation and testing Identification and classification of soil Part 1: Identification and descriptionISO 146
35、89-1, Geotechnical investigation and testing Identification and classification of rock Part 1: Identification and descriptionISO 22475-1, Geotechnical investigation and testing Sampling methods and groundwater measurements Part 1: Technical principles for executionENV 13005:1999, Guide to the expres
36、sion of uncertainty in measurement3 Terms, definitions and symbols3.1 Terms and definitionsFor the purposes of this document, the following terms and definitions apply.3.1.1pressuremeterwhole equipment which is used to carry out a Mnard pressuremeter test, excluding the means necessary to place the
37、pressuremeter probe into the groundNOTE 1 A pressuremeter includes a pressuremeter probe, a pressure and volume control unit, called CU, lines to connect the probe to the CU and, in the case of procedure B, a data logger which is either built into the CU or linked to it.NOTE 2 See Figure 2.3.1.2pres
38、suremeter test pocketcircular cylindrical cavity formed in the ground to receive a pressuremeter probe3.1.3pressuremeter boreholeborehole in which pressuremeter pockets with circular cross sections are made in the ground, and into which the pressuremeter probe is to be placed3.1.4pressuremeter testp
39、rocess during which a pressuremeter probe is inflated in the ground and the resulting pocket expansion is measured by volume as a function of time and pressure increments according to a defined programme NOTE See Figure 4 and F.1.3.1.5pressuremeter soundingwhole series of sequential operations neces
40、sary to perform Mnard pressuremeter testing at a given location, i.e. forming pressuremeter test pockets and performing pressuremeter tests in them NOTE See F.2.3.1.6pressuremeter pressure reading, prpressure pras read at the CU elevation in the liquid circuit supplying the central measuring cell2 I
41、SO 2012 All rights reservedBS EN ISO 22476-4:2012Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ISO 22476-4:2012(E)3.1.7pressure lossdifference between the pressure inside the p
42、robe and the pressure applied to the pocket wall3.1.8volume lossdifference between the volume actually injected into the probe and the volume read on the measuring device3.1.9raw pressuremeter curvegraphical plot of the injected volumes recorded at time 60 s, V60, versus the applied pressure at each
43、 pressure hold, pr3.1.10corrected pressuremeter curvegraphical plot of the corrected volume V versus the corrected pressure p NOTE See Figure 5.3.1.11Mnard creepdifference in volumes recorded at 60 s and at 30 s at each pressure hold: V60 V30= V60/303.1.12corrected Mnard creep curvegraphical plot of
44、 the corrected Mnard creep versus the corrected applied pressure at each pressure holdNOTE See Figure 5.3.1.13pressuremeter loggraphical report of the results of the pressuremeter tests performed in pockets at a succession of depths in the same pressuremeter borehole, together with all the informati
45、on gathered during the drilling NOTE See Annex F.3.1.14Mnard pressuremeter modulus, EME-modulus obtained from the section between (p1,V1) and (p2,V2) of the pressuremeter curve NOTE See Figure 5 and Annex D.3.1.15Mnard pressuremeter limit pressure, pLMpressure at which the volume of the test pocket
46、at the depth of the measuring cell has doubled its original volume NOTE See Annex D.3.1.16pressuremeter creep pressure, pfMpressure derived from the creep curve NOTE See Annex D.3.1.17operatorqualified person who carries out the test3.1.18casinglengths of tubing inserted into a borehole to prevent t
47、he hole caving in or to prevent the loss of flushing medium to the surrounding formation, above pocket location ISO 2012 All rights reserved 3BS EN ISO 22476-4:2012Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permi
48、tted without license from IHS-,-,-ISO 22476-4:2012(E)3.2 SymbolsFor the purposes of this document, the symbols given in Table 1 apply.Table 1 SymbolsSymbol Description Unita Apparatus volume loss coefficient cm3/MPadciOutside diameter of the inner part of the probe with slotted tube mmdiInside diameter of the calibration cylinder used for the volume loss calibration mmdcOutside diameter of the central measuring cell, including any additional protection such as a slotted tubemmdtDrilling tool diameter mme Wall thickness of the calibration cylinder u
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1