1、BRITISH STANDARD BS IEC 60874-14-3:1997 Connectors for optical fibres and cables Part 14-3: Detail specification for fibre optic adaptor (simplex) type SC for single-mode fibre ICS 33.180.20BSIEC 60874-14-3:1997 This British Standard, having been prepared under the directionof the Electrotechnical S
2、ector Committee, was published under the authority of the Standards Committee and comesinto effect on 15 December 1998 BSI 05-1999 ISBN 0 580 30914 2 National foreword This British Standard reproduces verbatim IEC 60874-14-3:1997 and implements it as the UK national standard. The UK participation in
3、 its preparation was entrusted by Technical Committee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Interconnecting devices and passive components, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on th
4、e interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented on this subcommittee can be obtained on request to its secretary. From 1 January 1997, all IEC pub
5、lications have the number 60000 added to the old number. For instance, IEC 27-1 has been renumbered as IEC 60027-1. For a period of time during the change over from one numbering system to the other, publications may contain identifiers from both systems. Cross-references The British Standards which
6、 implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not
7、 purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside fr
8、ont cover, pages i and ii, theIEC title page, page ii, pages 1 to 12 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. D
9、ate CommentsBSIEC 60874-14-3:1997 BSI 05-1999 i Contents Page National foreword Inside front cover Figure 1 Adaptor mating face dimensions 2 Figure 2 Adaptor dimensions 4 Figure 3 Panel piercing and mounting detail 5 Figure 4 Dimension of a pin gauge for an adaptor 5 Figure 5 Example of component ma
10、rking 6 Table 1 Fixed sample test schedule for qualification approval 7 Table 2 Lot-by-lot quality conformance inspection schedule 7 Table 3 Periodic quality conformance inspection schedule 8 Table 4 Details, measurements and performance requirements 9ii blankii blankBSIEC 60874-14-3:1997 BSI 05-199
11、9 1 CONNECTORS FOR OPTICAL FIBRES AND CABLES Part 14-3: Detail specification for fibre optic adaptor (simplex) type SC for single-mode fibre NATIONAL STANDARDS ORGANIZATION:Date: DETAIL SPECIFICATION IEC QC 910004XX0003. FIBRE OPTIC COMPONENT OF ASSESSED QUALITY IN ACCORDANCE WITH GENERIC SPECIFICAT
12、ION: QC 910000 (IEC 60874-1) BLANK DETAIL SPECIFICATION: QC 910001 (IEC 60874-1-1) FIBRE OPTIC ADAPTOR CLASSIFICATION: Type: Name: SC For use in datacom applications as specified in ISO/IEC International Standard 11801: “Generic cabling for customer premises” Configuration: plug-adaptor-plug Couplin
13、g: push-pull Control dimensions: Plug: see Figure 1, Figure 2 and Figure 3 Gauge: see Figure 4 Variants: see page 6 Climatic category: 10/60/4 Environmental category: 4 Assessment level: A QUALIFICATION PROCEDURE: Fixed sample procedure SAFETY WARNING: Take care when handling small diameter optical
14、fibre to prevent puncturing the skin, especially in the eye area. Direct viewing of the end of an optical fibre when it is propagating energy is not recommended unless prior assurance is obtained as to the safe energy output level.BSIEC 60874-14-3:1997 2 BSI 05-1999 Figure 1 Adaptor mating face dime
15、nsionsBSIEC 60874-14-3:1997 BSI 05-1999 3 Reference Dimensions Notes Minimum Maximum A 1 B 4,69mm 4,79mm D 4,9mm 5,5mm H 6,9mm 7,1mm I 0,4mm 0,8mm J 5,51mm 5,9mm K 0,06mm 1mm L 1,9mm 2,1mm O 2,0mm 2,2mm 2 P 9,0mm 9,1mm R 7,4mm 7,5mm rS 1,0mm 1,1mm radius T 3,80mm 4,04mm U 5,0mm 5,3mm V 0,6mm 1,6mm A
16、A 27 33 degrees AB 0,9mm 1,0mm rAC 0,4mm 0,6mm radius AD 0,7mm 0,8mm AE 0,4mm 0,6mm NOTE 1The connector alignment feature is an alignment sleeve. The gauge retention force shall be measured with two gauge pins, each inserted to the middle of the alignment feature. The gauge retention force shall be
17、from 2,0 N to5,9 N. NOTE 2For the angled PC variants (Nos. 1005 to 1008) the two slots “O” shall be symmetric within 0,03mm. NOTE 3Where a tolerance of form is not specified, the limits of the dimensions for a feature control the form as well as the size. NOTE 4Where interrelated features of size (f
18、eatures shown with a common axis or centre plane) have no geometric tolerance of location or run out specified, the limits of the dimensions for a feature control the location tolerance as well as the size. NOTE 5Where perpendicular features (features shown at right angles) have no geometric toleran
19、ce of orientation or run out specified, the limits of the dimensions for a feature control the orientation tolerance as well as the size. Figure 1 Adaptor mating face dimensions (continued)BSIEC 60874-14-3:1997 4 BSI 05-1999 Reference Dimensions mm Notes Minimum Maximum AF 21,5 22,5 1 AG 17,5 18,5 A
20、H 12,6 13,0 AI 9,2 9,4 1 AJ 2,2 2,5 AK 27,0 27,8 AL 2,8 3,2 AM 14,4 16,4 AN 7,7 8,0 AO 1,7 2,0 2 NOTE 1The dotted lines indicate an example of the shape of the mounting flange. The mounting flange shall be within these dimensions. NOTE 2If the adaptor is mounted using this hook, the thickness of the
21、 panel shall be 1,6mm. Figure 2 Adaptor dimensionsBSIEC 60874-14-3:1997 BSI 05-1999 5 Reference Dimensions mm Notes Minimum Maximum W 2,4 2,6 X 13,1 13,6 Y 17,9 18,1 Z 9,5 10,0 Figure 3 Panel piercing and mounting detail Reference Dimensions mm Notes Minimum Maximum CK 2,4985 2,4995 1 CL 2,8 4,8 CN
22、7 15 NOTE 1Surface roughness grade N4 (0,2 4m Ra). Figure 4 Dimension of a pin gauge for an adaptorBSIEC 60874-14-3:1997 6 BSI 05-1999 VARIANT IDENTIFICATION NUMBERS Number: QC 910X01/0003-ZZZZ Variant feature ZZZZ Component name Housing part material Sleeve material Preferred housing colour/indicat
23、or 1001 Adaptor SMF Plastic Zirconia Blue 1002 Adaptor SMF Plastic Phosphor bronze Blue 1003 Adaptor SMF Metal Zirconia Blue 1004 Adaptor SMF Metal Phosphor bronze Blue 1005 Adaptor APC Plastic Zirconia Green 1006 Adaptor APC Plastic Phosphor bronze Green 1007 Adaptor APC Metal Zirconia Green 1008 A
24、daptor APC Metal Phosphor bronze Green SUPPLEMENTARY INFORMATION Preferred colour: For SMF: blue according to: RAL 5015. For APC: green according to RAL 6029 NOTEThe variants 1001, 1003, 1005 and 1007 are recommended for APC connectors Component marking: The name and/or manufacturers identification
25、mark may be permanently identified. Figure 5 shows an example of the location of the component marking. Figure 5 Example of component markingBSIEC 60874-14-3:1997 BSI 05-1999 7 Table 1 Fixed sample test schedule for qualification approval Table 2 Lot-by-lot quality conformance inspection schedule Gr
26、oups A and B Test sequence Reference IEC 60874-1 (IEC 61300) n Group 0 Visual examination 4.4.1 (3-1) 20 Dimensions 4.4.2 (3-1) Gauge retention force (3-33) Group 1 Attenuation 4.4.7 (3-4) 20 Group 2 Cold 4.5.17 (2-17) Dry heat 4.5.18 (2-18) 6 Damp heat (steady state) 4.5.19 (2-19) Group 3 Engagemen
27、t and separation force 4.4.5 (3-11) Mechanical endurance 4.5.32 (2-2) 6 Group 4 Vibration 4.5.1 (2-1) 4 Change of temperature (test Nb) 4.5.22 (2-22) Group 5 Strength of coupling mechanism 4.5.6 (2-6) 4 NOTE 1n = sample size (number of plugs). NOTE 2To satisfy the qualification approval requirements
28、 of the detail specification there shall be no failures of any in the sample groups for any test parameter. If a failure does occur this shall be investigated and the cause of failure identified and corrected. The test which is affected shall then be repeated using the minimum sample size stated in
29、this detail specification. A fully documented test report and supporting data shall be prepared and shall be available for inspection. Failures and the corrective action taken to eliminate failures shall be documented and evidence shall be presented to show that the corrective action will have no de
30、trimental effect on the performance in any of the other tests. Design changes, as opposed to improvements in quality control, will usually be deemed to necessitate a repeat of the full qualification programme. NOTE 3Unless otherwise indicated, the test details, measurements and performance requireme
31、nts are given in Table 4. NOTE 4Only group 1 tests shall be carried out using a reference connector. All other tests shall be carried out using the samples from the relevant group at random. Test sequence Reference IEC 60874-1 (IEC 61300) Assessment level A IL AQL Group A Visual examination 4.4.1 (3
32、-1) II 4 % Gauge retention force 4.4.2 (3-33) Group B Attenuation 4.4.7 (3-4) II 4 % NOTE 1Unless otherwise indicated, the details, measurements and performance requirements are given in Table 4. NOTE 2IL = Inspection level; AQL = Acceptable quality level. NOTE 3Only group B tests shall be carried o
33、ut using a reference connector. All other tests shall be carried out using the samples from the relevant group at random.BSIEC 60874-14-3:1997 8 BSI 05-1999 Table 3 Periodic quality conformance inspection schedule Groups C and D Test sequence Reference IEC 60874-1 (IEC 61300) Assessment level A n p
34、Group C0 Visual examination 4.4.1 (3-1) 18 24 Dimensions 4.4.2 (3-1) Gauge retention force (3-33) Group C1 Attenuation 4.4.7 (3-4) 18 24 Group C2 Cold 4.5.17 (2-17) Dry heat 4.5.18 (2-18) 6 24 Damp heat (steady state) 4.5.19 (2-19) Group D0 Visual examination 4.4.1 (3-1) 20 48 Dimensions 4.4.2 (3-1)
35、 Gauge retention force (3-33) Group D1 Attenuation 4.4.7 (3-4) 20 48 Group D2 Cold 4.5.17 (2-17) Dry heat 4.5.18 (2-18) 6 48 Damp heat (steady state) 4.5.19 (2-19) Group D3 Engagement and separation force 4.4.5 (3-11) Mechanical endurance 4.5.2 (2-2) 6 48 Group D4 Vibration 4.5.1 (2-1) 4 48 Change o
36、f temperature (test Nb) 4.5.22 (2-22) Group D5 Strength of coupling mechanism 4.5.6 (2-6) 4 48 NOTE 1Unless otherwise indicated, the details, measurements and performance requirements are given in Table 4. NOTE 2To satisfy the qualification approval requirements of the detail specification there sha
37、ll be no failures of any in the sample groups for any test parameter. If a failure does occur this shall be investigated and the cause of failure identified and corrected. The test which is affected shall then be repeated using the minimum sample size stated in this detail specification. A fully doc
38、umented test report and supporting data shall be prepared and shall be available for inspection. Failures and the corrective action taken to eliminate failures shall be documented and evidence shall be presented to show that the corrective action will have no detrimental effect on the performance in
39、 any of the other tests. Design changes, as opposed to improvements in quality control, will usually be deemed to necessitate a repeat of the full qualification programme. NOTE 3n = sample size (number of plugs); p = periodicity in months. NOTE 4Only group C1 and D1 tests shall be carried out using
40、a reference connector. All other tests shall be carried out using the samples from the relevant group at random.BSIEC 60874-14-3:1997 BSI 05-1999 9 Table 4 Details, Measurements and performance requirements Visual examination 4.4.1 (61300-3-1) Requirements: Marking shall be clear Dimensions 4.4.2 (6
41、1300-3-1) Gauge retention force (61300-3-33) Requirements: All size dimensions shall be in accordance with this specification Attenuation 4.4.7 (61300-3-4) Details: Method No. 8 Definitions of reference components are as follows: Reference plug Reference plug shall be in accordance with IEC 60874-14
42、-5 (SC PC untuned) for variants 1001 to 1004 IEC 60874-14-6 (SC APC 9 untuned) IEC 60874-14-10 (SC APC 8 untuned) for variants 1005 to 1008 Reference adaptor The reference adaptor is a selected low-loss adaptor. The selection criterion that must be met is: using two reference plugs and the adaptor,
43、10 repeated measurements of attenuation with direction insertion of the plugs alternated between measurements will give a maximum attenuation less than 0,1 dB. Number of measurements to be averaged: 5 Source: LD Peak wavelength: 1,3 4m Preconditioning procedure: clean ferrule endface and inside of a
44、lignment sleeve using lint free material Length L1: 2 m Length L2: 2 m Recovery procedure: none Requirements: Allowable attenuation: less than 0,2 dB against two reference plugs Cold 4.5.17 (61300-2-17) Details: Temperature: 10 C Duration: 96 h Specimen optically functioning Conditioning procedure:
45、specimen lowered to test temperature and returned to room temperature at a rate not to exceed 1 /min Deviations: none Plug shall be in accordance with: IEC 60874-14-5 (SC-PC untuned) for variants 1001 to 1004 IEC 60874-14-6 (SC-APC 9 untuned) or IEC 60874-14-10 (SC-APC 8 untuned) for variants 1005 t
46、o 1008 Monitoring method of attenuation and return loss shall be in accordance with IEC 61300-3-20 Preconditioning procedure: clean ferrule endface and inside of alignment sleeve using lint free material Recovery procedure: after tests, specimens shall be maintained at room temperature condition for
47、 2 h Clean ferrule endface and inside of alignment sleeve using lint free material before final measurement Initial measurements and performance requirements: Attenuation: less than 0,75 dB Measurements and performance requirements during test: Attenuation: less than 0,75 dB Change in attenuation: l
48、ess than 0,2 dB Final measurements and performance requirements: Attenuation: less than 0,75 dB Change in attenuation: less than 0,2 dBBSIEC 60874-14-3:1997 10 BSI 05-1999 Table 4 Details, measurements and performance requirements Dry heat 4.5.18 (61300-2-18) Details: Temperature: 60 C Duration: 96
49、h Specimen optically functioning. Conditioning procedure: specimen raised to test temperature and returned to room temperature at a rate not to exceed 1 /min. Deviations: none Plug shall be in accordance with: IEC 60874-14-5 (SC-PC untuned) for variants 1001 to 1004 IEC 60874-14-6 (SC-APC 9 untuned) or IEC 60874-14-10 (SC-APC 8 untuned) for variants 1005 to 1008