1、| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BRITISH STANDARD BS ISO 10294-2:1999 ICS 1
2、3.220.50: 91.140.30 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Fire resistance tests Fire dampers for air distribution systems Part 2: Classification, criteria and field of application of test resultsThis British Standard, having been prepared under the direction of the H
3、ealth and Environment Sector Committee, was published under the authority of the Standards Committee and comes into effect on 15 November 1999 BSI 11-1999 ISBN 0 580 35280 3 BS ISO 10294-2:1999 Amendments issued since publication Amd. No. Date Comments National foreword This British Standard reprodu
4、ces verbatim ISO 10294-2:1999 and implements it as the UK national standard. The UK participation in its preparation was entrusted by Technical Committee FSH/22, Fire resistance tests, to Subcommittee FSH/22/4, Test procedures for dampers, which has the responsibility to: aid enquirers to understand
5、 the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented on this
6、subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using
7、the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity fr
8、om legal obligations. Summary of pages This document comprises a front cover, an inside front cover, the ISO title page, page ii, pages 1 to 4, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued.A Referencenumbe r IS
9、O102942:1999 (E) INTERNATIONAL STANDARD ISO 102942 Firstedition 19990415 FireresistancetestsFiredampersforair distributionsystems Part2: Classification,criteriaandfieldofapplication oftestresults EssaisdersistanceaufeuClapetsrsistantaufeupoursystmesde distributiondair Partie2:Classification,critrese
10、tdomainedapplicationdesrsultats dessaiISO102942:1999(E) ii Foreword ISO (the InternationalOrganizationforStandardization)isaworldwidefederationofnationalstandardsbodies(ISO memberbodies).TheworkofpreparingInternationalStandardsisnormallycarriedoutthroughISOtechnical committees.Eachmemberbodyinterest
11、edinasubjectforwhichatechnicalcommitteehasbeenestablishedhas therighttoberepresentedonthatcommittee.Internationalorganizations,governmentalandnongovernmental,in liaisonwithISO,alsotakepartinthework.ISOcollaboratescloselywiththeInternationalElectrotechnical Commission(IEC)onallmattersofelectrotechnic
12、alstandardization. InternationalStandardsaredraftedinaccordancewiththerulesgivenintheISO/IECDirectives,Part3. DraftInternationalStandardsadoptedbythetechnicalcommitteesarecirculatedtoth ememberbodiesforvoting. PublicationasanInternationalStandardrequiresapprovalbyatleast75%ofthememberbodiescastingav
13、ote. InternationalStandardISO102942waspreparedbyTechnicalCommitteeISO/TC 92,Firesafety,Subcommittee SC2, Fireresistance . PreparationofthispartofISO 10294wasnecessarybecauseoftheneedtoprovideclassification,criteriaan d field of applicationforthetestmethodgiveninISO 102941:1996. ISO10294consistsofthe
14、followingparts,underthegeneraltitleFireresistancetestsFiredampersforair distributionsystems: Part1:Testmethod Part2:Classification,criteriaandfieldofapplicationoftestresults Part3:Guidanceonthetestmethod Part4:ThermalreleasemechanismtestINTERNATIONALSTANDARD ISO102942:1999(E) 1 FireresistancetestsFi
15、redampersforairdistributionsystems Part2: Classification,criteriaandfieldofapplicationoftestresults 1Scope ThispartofISO 10294providestheclassificationandappropriatecriteriaforthetestproceduredescribedin ISO102941:1996,fortheassessmentofafiredampertopreventthespreadoffirean dhotgasesfromone compartm
16、enttoanother.Italsospecifiesthesizeofthedamperstobetested. 2Normativereferences The followingnormativedocumentscontainprovisionswhich,throughreferenceinthistext,constituteprovisionsof thispartofISO 10294.Fordatedreferences,subsequentamendments to, or revisions of, any of these publications donotappl
17、y.However,partiestoagreementsbasedonthispartofISO 10294areencouragedtoinvestigatethe possibilityofapplyingthemostrecenteditionsofthenormativedocumentsindicatedbelow .Forundated references,thelatesteditionofthenormativedocumentreferredtoapplies.MembersofISOan dIECmaintain registersofcurrentlyvalidInt
18、ernationalStandards. ISO102941:1996 ,FireresistancetestsFiredampersforairdistributionsystemsPart2:Classification,criteria andfieldofapplicationoftestresults. ISO102943:1999 ,FireresistancetestsFiredampersforairdistributionsystemsPart3:Guidanceonthetest method. 3Classificationandcriteria Dependingont
19、heclassificationrequired,thesizeofthefiredamper tobetestedandthecriteriatobeappliedare giveninTable1.ISO102942:1999(E) 2 Table1Firetestperformancecriteria Classification a Sizetobetested Leakageatambient temperature m 3 /(h m 2 ) Firetest (Seeclause9ofISO102941:1996) (Seeclause8of ISO102941:1996) Le
20、akageli mited m 3 /(h m 2 ) Temperaturerise limit,C mean/max. Perimeter integrity b E max. notrequired 360 c notrequired GG/SF ES max. 200 200 c notrequired GG/SF min. 200 notrequired notrequired notrequired EI max. notrequired 360 c 140/180 CP/GG/SF EIS max. 200 200 c 140/180 CP/GG/SF min. 200 notr
21、equired notrequired notrequired Inrelationtothecriteriaforleakage(S),thevaluesgivenshallbesatisfiedinboththeambienttemperature(smallestdamp erand largestdamperintherange)andthefiretest(largestdamperintherange). NOTE1Themaximumtemperatureriselimit(18 0C)canbedeterminedatanyofthethermo couplesT 1 ,T 2
22、 andT s s (orthero ving thermocouplede scribedinIS O 8341)andthemean(a verage)temperatureri se(14 0 C)willbedetermine d from thermocouples T 2 .Locationsof thethermocouplesareshowninFigures3to8ofI SO 102941:1996. NOTE2Forthepurpo sesof calculatingcompliancewiththelea kagecriteriainthistable,theareao
23、fadampermaybeta kentobeth ecross sectionalareaoftheducttowhichthedamperisconnected. NOTE3Classificationofintegrityisa ccordingtowhetherornotthedamperis alsoclassifiedforinsulation.Wherea damperisclassifiedfor integrityEandin sulationI,theintegrityisthatdeterminedbywhi cheverofthethree criteriafailsf
24、ir st.Whereadamperi scl assifiedE but without anIclassification,theintegrityvalueisdefinedasthetimetofailureofonlythecracks/openingsorsustainedflamingcriteria,whicheverfailsfirst. a E istheintegrity(gasflowcorrectedto20C); I isthein sulation( seenote1); S isthelea kage classification( seenote2)(gasl
25、ea kage correctedto20C). b CP isthecottonpad(seenote3); GG is thegapgauge( see note 3); SF is the sustainedflaming( see note3 ). c Leakagelimitsonlyapplyafter5minfromthestartofthetest. 4Fieldofapplicationoftestresults 4.1Sizeoffiredamper IftheSclassificationisnotrequired,atestresultobtainedforthelar
26、gestfiredamperintherangeisapplicabletoall dampersofthesametype(includinganyaspectratio)providedthatthemaximumdimensionsd onotexceedthose testedandthatthecomponentsremaininthesameorientationasthattested. IftheSclassificationisrequired,anadditionalfiredamper,representingthesmallestsizeinth e range, sh
27、all satisfy the smokeleakagecriteriawhentestedaccordingtotheproceduredescribedinclause8ofISO102941:1996. 4.2Firedampersinstalledwithinstructuralopenings Atestresultobtainedforaninstalledfiredamperisonlyapplicabletodampersinstalle d in the same orientation as that tested(seealso6.1.2ofISO102943:1999)
28、. 4.3Firedampersmountedontothefaceofawallorfloor Atestresultobtainedforafiredamperinstalledontothefaceofawallorflooris onlyapplicabletodampersinstalled ontothefaceofaseparatingelementinthesameorientationasthattested(seealso6.1.4ofISO102943:1999). ISO102942:1999(E) 3 4.4Firedampersremotefromawallorfl
29、oor See6.1.5ofISO102943:1999. Atestresultobtainedforafiredamperremotefromawallorfloor(ofthesamefireresistanceasthedamper)is applicabletothefollowingdampers: a) formountingremotefromawallandattachedtoalengthofahorizontalfireresistingductworkwhentested remotefromawall(twotests,seeFigures7and8ofISO1029
30、41:1996); b) formountingremotefromafloorandattachedtoalengthofverticalfireresistingductworkonthesideabove thefloorwhentestedabovethefloor; c) formountingremotefromafloorandattachedtoalengtho fverticalfireresistingductworkonthesidebelow thefloorwhentestedbelowthefloor. 4.5Separationbetweenfiredampers
31、andbetweenfiredampersandconstructionelements Atestresultobtainedforonlyonefiredamperorfortwofiredamperswithaminimumclearseparationof20 0 mm betweenthedampersisapplicabletoaminimumseparation,inpractice,of: a) 200mmbetweendampersinstalledinseparateducts; b) 75mmbetweendamperandaconstructionelement(wal
32、l/floor). 4.6Supportingconstructions 4.6.1 Atestobtainedforafiredampermountedinoronthefaceofasupportingconstructionmadeofmasonry, concreteorhomogeneouspartition(withoutcontinuouscavity)isapplicablefor thesametypeofsupporting constructionwithathicknessanddensityequaltoorgreaterthanthoseofthesupportin
33、gconstructionusedinthe test. The test result can apply to cellular or hollowmasonryblocksorslabsthathaveafireresistancetimeequalto orgreaterthanthefireresistancerequiredforthefiredamperinstallation. 4.6.2 Ifaspecificsupportingconstructiondifferentfro mthosedescribedin6.5.2ofISO 102941:1996isselected
34、, thetestresultsobtainedareapplicableonlytothatspecificwall,partitionorfloorhavingathicknessand/ordensity greaterthanthattested.ISO102942:1999(E) 4 Bibliography ISO8341: 1) ,FireresistancetestsElementsofbuildingconstructionPart1:Generalrequirements . 1) Tobepublished.BS ISO 10294-2:1999 BSI 389 Chis
35、wick High Road London W4 4AL | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BSI British Stand
36、ards Institution BSI is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter. Revisions British Standards are updated by amendment or revision. Users of British St
37、andards should make sure that they possess the latest amendments or editions. It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using this British Standard would inform the Secretary of the techn
38、ical committee responsible, the identity of which can be found on the inside front cover. Tel: 020 8996 9000. Fax: 020 8996 7400. BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards. Buying standards Orde
39、rs for all BSI, international and foreign standards publications should be addressed to Customer Services. Tel: 020 8996 9001. Fax: 020 8996 7001. In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standar
40、ds, unless otherwise requested. Information on standards BSI provides a wide range of information on national, European and international standards through its Library and its Technical Help to Exporters Service. Various BSI electronic information services are also available which give details on al
41、l its products and services. Contact the Information Centre. Tel: 020 8996 7111. Fax: 020 8996 7048. Subscribing members of BSI are kept up to date with standards developments and receive substantial discounts on the purchase price of standards. For details of these and other benefits contact Member
42、ship Administration. Tel: 020 8996 7002. Fax: 020 8996 7001. Copyright Copyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of the publications of the international standardization bodies. Except as permitted under the Copyright, Designs and Patents Act 1988 no extrac
43、t may be reproduced, stored in a retrieval system or transmitted in any form or by any means electronic, photocopying, recording or otherwise without prior written permission from BSI. This does not preclude the free use, in the course of implementing the standard, of necessary details such as symbo
44、ls, and size, type or grade designations. If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained. If permission is granted, the terms may include royalty payments or a licensing agreement. Details and advice can be obtained from the Copyright Manager. Tel: 020 8996 7070.