1、BRITISH STANDARD BS ISO 15407-2:2003 Pneumatic fluid power Five-port directional control valves, sizes 18 mm and 26 mm Part 2: Mounting interface surfaces with optional electrical connector ICS 23.100.50 BS ISO 15407-2:2003 This British Standard was published under the authority of the Standards Pol
2、icy and Strategy Committee on 16 May 2003 BSI 16 May 2003 ISBN 0 580 41893 6 National foreword This British Standard reproduces verbatim ISO 15407-2:2003 and implements it as the UK national standard. The UK participation in its preparation was entrusted to Technical Committee MCE/18, Fluid power sy
3、stems and components, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international publications referred to in this document may be found in the BSI Catalogue u
4、nder the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct a
5、pplication. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed
6、; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the ISO title page, pages ii to iv, pages 1 to 9 and a back cover. The BSI copyright date displayed in this document indicates when
7、the document was last issued. Amendments issued since publication Amd. No. Date Comments Reference number ISO 15407-2:2003(E)INTERNATIONAL STANDARD ISO 15407-2 First edition 2003-04-15 Pneumatic fluid power Five-port directional control valves, sizes 18 mm and 26 mm Part 2: Mounting interface surfac
8、es with optional electrical connector Transmissions pneumatiques Distributeurs de commande directionnels cinq orifices, tailles 18 mm et 26 mm Partie 2: Surfaces dinterface de montage avec connecteur lectrique facultatif BSISO154072:2003ii BSISO154072:2003 iiiForeword ISO (the International Organiza
9、tion for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established
10、has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. In
11、ternational Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publi
12、cation as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent r
13、ights. ISO 15407-2 was prepared by Technical Committee ISO/TC 131, Fluid power systems, Subcommittee SC 5, Control products and components. ISO 15407 consists of the following parts, under the general title Pneumatic fluid power Five-port directional control valves, sizes 18 mm and 26 mm: Part 1: Mo
14、unting interface surfaces without electrical connector Part 2: Mounting interface surfaces with optional electrical connector BSISO154072:2003 iv Introduction In pneumatic fluid power systems, power is transmitted and controlled through gas under pressure within a circuit. The various devices for ga
15、s distribution and control can be either mounted directly on to the piping, or mounted on interface surfaces, allowing quicker dismantling and promoting equipment interchangeability. Pneumatic directional control valves of the five-port type, as used on mounting interface surfaces complying with the
16、 requirements of this part of ISO 15407, control the flow of compressed gas. When the valve is electrically operated, it may be desirable to use an electrical connector at the interface of the valve body and base. Users of pneumatic valves benefit when this electrical connector is standardized, allo
17、wing easy electrical connection interchangeability between valves produced by different manufacturers. Standardization of port and orifice identification, the result of control-mechanism actuation and a system of dimensional tolerances are provided to enhance mounting interchangeability of pneumatic
18、 control valves used on the mounting surfaces complying with the requirements of this part of ISO 15407. BSISO154072:2003INTENRATIONAL TSANDADR IS-70451 O2:(3002E)I SO 3002 All irhgts seredevr 1Pneumatic fluid power Five-port directional control valves, sizes 18 mm and 26 mm Part 2: Mounting interfa
19、ce surfaces with optional electrical connector 1 Scope This part of ISO 15407 specifies the following requirements for a mounting interface and electrical connector for five-port pneumatic directional control valves, sizes 18 mm and 26 mm, for use at a maximum rated pressure of 1,6 MPa 16 bar 1) : d
20、imensions and tolerances of the interface features; port identification; identification of the result of control-mechanism actuation; dimensions, tolerances and specifications for optional interface electrical connector mateability. It is not applicable to the functional characteristics of interface
21、s. NOTE The requirements for mounting interfaces of five-port directional control valves, sizes 18 mm and 26 mm, without electrical connector are specified in ISO 15407-1. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated refe
22、rences, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 1101: 2) , Geometrical Product Specifications (GPS) Geometrical tolerancing Tolerances of form, orientation, location and run-out ISO 1302, Geometrica
23、l Product Specifications (GPS) Indication of surface texture in technical product documentation ISO 4287, Geometrical Product Specifications (GPS) Surface texture: Profile method Terms, definitions and surface texture parameters ISO 4288, Geometrical Product Specifications (GPS) Surface texture: Pro
24、file method Rules and procedures for the assessment of surface texture 1) 1 bar = 0,1 MPa = 10 5Pa; 1 Pa = 1 N/m 22) To be published. (Revision of ISO 1101:1983) BSISO154072:20031ISO 15407-2:2003(E) 2 I SO 3002 All irhgts seredevrISO 5598, Fluid power systems and components Vocabulary ISO 11727, Pne
25、umatic fluid power Identification of ports and control mechanisms of control valves and other components 3 Terms and definitions For the purposes of this part of ISO 15407, the terms and definitions given in ISO 5598 and the following apply. 3.1 electrical connector device consisting of two parts (c
26、ontact and housing) that, when they are joined, provide electrical and mechanical continuity 3.2 contact current-carrying component used at a removable junction of an electric circuit 3.3 socket contact with an opening or hollow designed to be the mechanical holder of a pin-type contact 3.4 pin poin
27、ted contact designed to mate with a socket contact 3.5 housing device designed to orient, secure and insulate contacts 4 Dimensional requirements and tolerances 4.1 Dimensional requirements for sizes 18 mm and 26 mm are shown in Figure 1 and given in Table 1. 4.2 The tolerances of form and location
28、of the interface features, and position tolerance are shown in Figure 2. 4.3 Tolerances on surface condition, within the continuous wide outer boundary lines in Figure 1, shall be as follows: surface roughness: Ra = 1,6 m (see ISO 1302, ISO 4287 and ISO 4288); surface flatness: 0,1 mm over a distanc
29、e of 100 mm (see ISO 1101). EXAMPLE 0,1 / 1004.4 The mounting surface shall not include any orifices other than those shown in the figures. All passages shown in the interface shall be included, and connected to open ports in the base. BSISO154072:20032ISO 15407-2:2003(E) I SO 3002 All irhgts serede
30、vr 35 Identification of ports and orifices 5.1 Identification of ports and electrical leads shall conform to ISO 11727. 5.2 The flow path orifices in the mounting surface interface, and the ports serving these orifices, shall be designated as follows (see Figures 1 and 2): ports 1, 2, 3, 4 and 5 are
31、 the principal flow paths; ports 12 and 14 are the actuation orifices. NOTE Port 14 is preferred for single-source external solenoid pilot supply. 5.3 For monostable valves, the mandatory stable position of the valve shall always be identical to the result of actuation by control mechanism 12, as sh
32、own in Figure 4. 5.4 When a positive signal is applied to control mechanism 12, flow port 1 shall be connected with flow port 2 (and 4 with 5). When a positive signal is applied to control mechanism 14, flow port 1 shall be connected with flow port 4 (and 2 with 3) (see Figure 5 and ISO 11727). 5.5
33、The orientation of control mechanisms 12 and 14 on the valve relative to flow ports 2, 3, 4 and 5 in the base shall be as shown in Figures 4 and 5. 6 Electrical connector 6.1 General Figure 3 is an illustration of an electrical connector, showing pin, socket and housing, for use with mounting surfac
34、es with openings for an electrical connector. Figure 3 also shows dimensions for this electrical connector. 6.2 Connectors The connector shall be readily removable, if not required, and shall comply with the requirements of 6.2.1 to 6.2.3. 6.2.1 Connectors shall be rated at a nominal voltage of 125
35、V maximum d.c. or a.c. 6.2.2 Connectors shall be rated at not less than 1 A. 6.2.3 Dielectric withstanding voltage shall be 1 500 V a.c. minimum rms (sea level). 6.3 Contacts 6.3.1 Connectors shall comprise three live contacts and one earth contact. 6.3.2 The pins shall be 0,64 mm square. 6.3.3 The
36、pins shall be located at 2,54 mm centrelines. 6.3.4 Receptacle contacts shall have an opening that allows friction fits on the pins. BSISO154072:20033ISO 15407-2:2003(E) 4 I SO 3002 All irhgts seredevr6.4 Dimensions, orientation and pin assignments 6.4.1 The dimensions of the electrical connector sh
37、all conform to those given in Figure 3. 6.4.2 The contacts shall be located at the corners of a square. 6.4.3 Contacts 2 and 4 shall be oriented parallel to the valve port slots and towards the valve interior. 6.4.4 Contacts 1 and 4 shall be used with single solenoid valves. 6.4.5 Contacts 2 and 4 s
38、hall be used with the second solenoid of a double solenoid valve. 6.4.6 Contact 4 shall be the common return for solenoids 14 and 12. 6.4.7 Contact 3 shall be the earth contact. 6.4.8 Indicator lights and/or surge suppression are optional but shall be insensitive to polarity. 7 Identification statem
39、ent (Reference to this part of ISO 15407) Use of the following statement in test reports, catalogues and sales literature when electing to comply with this part of ISO 15407 is strongly recommended: “Mounting interface dimensions conforming to ISO 15407-2:2003, Pneumatic fluid power Five-port direct
40、ional control valves, sizes 18 mm and 26 mm Part 2: Mounting interface surfaces with optional electrical connector.“ BSISO154072:20034ISO 15407-2:2003(E) I SO 3002 All irhgts seredevr 5Key aLocation hole U, depth V bSee Figure 3. Figure 1 Mounting surface with opening for electrical connector Sizes
41、18 mm and 26 mm Table 1 Dimensions of mounting surfaces with opening for electrical connector Sizes 18 mm and 26 mm Dimensions in millimetres Size A B D E F G G 1 G 2 K L 1L 2L TEP T U V W X X 1Y amin.min. min. min. 18 3,5 7 6,25 50 17 2 8 6 3,35 25 55,5 80,5 20 M3 3,2 4 18 6,5 5,25 19 26 5,5 9,5 9,
42、5 58 24 3 13 9 7,35 33 63,5 96,5 27,5 M4 3,2 4 26 9 8,5 27 aY represents the minimum distance between the axes of successive mounting interfaces of the same size on a multiple block. BSISO154072:20035ISO 15407-2:2003(E) 6 I SO 3002 All irhgts seredevrDimensions in millimetres aFor size 18 mm bFor si
43、ze 26 mm Figure 2 Form and position tolerances of the features of the mounting interface surfaces BSISO154072:20036ISO 15407-2:2003(E) I SO 3002 All irhgts seredevr 7Dimensions in millimetres, surface roughness values in micrometres Top of base Electrical schematic Cross-section ZZ-Connector details
44、 Key 1 Opening for solenoid 14, socket 1 6 Base 2 Opening for solenoid 12, socket 2 7 Pin housing secured to valve body 3 Opening for earth contact, socket 3 8 Optional circuit board in base 4 Opening for common, socket 4 9 Valve connected to pin housing 5 Seal (O-ring is shown as an example; other
45、seal types may be used, as long as intermateability is maintained) 10 Optional socket housing 11 Square pin, 0,64 mm 0,64 mm aSquare opening on top of socket housing, if used, shall be large enough for a 0,64 mm by 0,64 mm square pin to pass through. bSee 6.4.8 for electrical devices Figure 3 Electr
46、ical connector BSISO154072:20037ISO 15407-2:2003(E) 8 I SO 3002 All irhgts seredevrFigure 4 Mandatory stable position of monostable valve Figure 5 Communication between ports associated with pilot controls BSISO154072:20038ISO 15407-2:2003(E) I SO 3002 All irhgts seredevr 9Bibliography 1 ISO 129-1,
47、Technical drawings Indication of dimensions and tolerances Part 1: General principles 2 ISO 1219-1, Fluid power systems and components Graphic symbols and circuit diagrams Part 1: Graphic symbols 3 ISO 4400, Fluid power systems and components Three-pin electrical plug connectors with earth contact C
48、haracteristics and requirements 4 ISO 4414, Pneumatic fluid power General rules relating to systems 5 ISO 5599-1, Pneumatic fluid power Five-port directional control valves Part 1: Mounting interface surfaces without electrical connector 6 ISO 5599-2, Pneumatic fluid power Five-port directional cont
49、rol valves Part 2: Mounting interface surfaces with optional electrical connector 7 ISO 5599-3, Pneumatic fluid power Five-port directional control valves Part 3: Code system for communication of valve functions 8 ISO 15407-1, Pneumatic fluid power Five-port directional control valves, sizes 18 mm and 26 mm Part 1:
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有