1、BS ISO 5546:2010ICS 67.100.99NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDCaseins and caseinates Determination of pH(Reference method)This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 July2010 BSI 201
2、0ISBN 978 0 580 70099 6Amendments/corrigenda issued since publicationDate CommentsBS ISO 5546:2010National forewordThis British Standard is the UK implementation of ISO 5546:2010. Itsupersedes BS 6248-4:1982 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommitt
3、ee AW/5, Chemical analysis of milk and milk products.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application. Compliance
4、with a British Standard cannot confer immunityfrom legal obligations.BS ISO 5546:2010Reference numbersISO 5546:2010(E)IDF 115:2010(E)ISO and IDF 2010INTERNATIONAL STANDARD ISO5546IDF115Second edition2010-06-01Caseins and caseinates Determination of pH (Reference method) Casines et casinates Dtermina
5、tion du pH (Mthode de rfrence)BS ISO 5546:2010ISO 5546:2010(E) IDF 115:2010(E) PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to a
6、nd installed on the computer performing the editing. In downloading this file, parties accept therein the responsibility of not infringing Adobes licensing policy. Neither the ISO Central Secretariat nor the IDF accepts any liability in this area. Adobe is a trademark of Adobe Systems Incorporated.
7、Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies and IDF national committees. In the
8、 unlikely event that a problem relating to it is found, please inform the ISO Central Secretariat at the address given below. COPYRIGHT PROTECTED DOCUMENT ISO and IDF 2010 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any
9、 means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO or IDF at the respective address below. ISO copyright office International Dairy Federation Case postale 56 CH-1211 Geneva 20 Diamant Building Boulevard Auguste Reyers 80 B-1030 Brus
10、sels Tel. + 41 22 749 01 11 Tel. + 32 2 733 98 88 Fax + 41 22 749 09 47 Fax + 32 2 733 04 13 E-mail copyrightiso.org E-mail infofil-idf.org Web www.iso.org Web www.fil-idf.org Published in Switzerland ii ISO and IDF 2010 All rights reservedBS ISO 5546:2010ISO 5546:2010(E) IDF 115:2010(E) ISO and IDF
11、 2010 All rights reserved iiiForeword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interest
12、ed in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Co
13、mmission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the techn
14、ical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO s
15、hall not be held responsible for identifying any or all such patent rights. ISO 5546IDF 115 was prepared by Technical Committee ISO/TC 34, Food products, Subcommittee SC 5, Milk and milk products, and the International Dairy Federation (IDF). It is being published jointly by ISO and IDF. This second
16、 edition of ISO 5546IDF 115 cancels and replaces the first edition (ISO 5546:1979), of which it constitutes a minor revision. BS ISO 5546:2010ISO 5546:2010(E) IDF 115:2010(E) iv ISO and IDF 2010 All rights reservedForeword IDF (the International Dairy Federation) is a non-profit organization represe
17、nting the dairy sector worldwide. IDF membership comprises National Committees in every member country as well as regional dairy associations having signed a formal agreement on cooperation with IDF. All members of IDF have the right to be represented on the IDF Standing Committees carrying out the
18、technical work. IDF collaborates with ISO in the development of standard methods of analysis and sampling for milk and milk products. The main task of Standing Committees is to prepare International Standards. Draft International Standards adopted by the Standing Committees are circulated to the Nat
19、ional Committees for endorsement prior to publication as an International Standard. Publication as an International Standard requires approval by at least 50% of IDF National Committees casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subjec
20、t of patent rights. IDF shall not be held responsible for identifying any or all such patent rights. ISO 5546IDF 115 was prepared by the International Dairy Federation (IDF) and Technical Committee ISO/TC 34, Food products, Subcommittee SC 5, Milk and milk products. It is being published jointly by
21、IDF and ISO. All work was carried out by the former Joint ISO-IDF Action Team on Minor compounds, now part of the Standing Committee on Analytical methods for composition. This edition of ISO 5546|IDF 115 cancels and replaces IDF 115A:1989, of which it constitutes a minor revision. BS ISO 5546:2010I
22、NTERNATIONAL STANDARD ISO 5546:2010(E)IDF 115:2010(E) ISO and IDF 2010 All rights reserved 1Caseins and caseinates Determination of pH (Reference method) 1 Scope This International Standard specifies a reference method for the determination of the pH of all types of casein (acid caseins and rennet c
23、aseins) and of caseinates. 2 Terms and definitions For the purposes of this document, the following terms and definitions apply. 2.1 pH of caseins and caseinates pH, at 20 C, of an aqueous extract of casein or an aqueous solution of caseinate, as determined by the procedure specified in this Interna
24、tional Standard 3 Principle The pH of an aqueous extract of casein or an aqueous solution of caseinate is determined electrometrically using a pH meter. 4 Reagents Unless otherwise stated, use only reagents of recognized analytical grade and recently distilled water that has been protected from carb
25、on dioxide absorption. 4.1 Buffer solutions, for calibration of the pH meter (5.2). Two standard buffer solutions with pH values at 20 C, which are known to the second decimal place and which bracket the pH value of the sample under test, e.g. a phthalate buffer solution of approximately pH 4 and a
26、borax buffer solution of approximately pH 9. In addition, a phosphate buffer solution of approximately pH 7 may be used. 5 Apparatus Usual laboratory equipment and in particular the following. 5.1 Balance, accurate to the nearest 0,1 g. 5.2 pH meter, minimum sensitivity 0,05 pH unit, with a suitable
27、 glass electrode and a calomel or other reference electrode. 5.3 Thermometer, accurate to the nearest 0,5 C. BS ISO 5546:2010ISO 5546:2010(E) IDF 115:2010(E) 2 ISO and IDF 2010 All rights reserved5.4 Conical flask, capacity 100 ml, fitted with a ground-glass stopper. 5.5 Beaker, capacity 50 ml. 5.6
28、Grinding device, for grinding the laboratory sample, if necessary (see 7.4), without producing undue heat and loss or absorption of moisture. A hammer mill shall not be used. 5.7 Test sieve, wire cloth, diameter 200 mm, nominal size of openings 500 m, with receiver, ISO 3310-12. 5.8 Mixer. 5.9 Beake
29、r, for the mixer (5.8), capacity at least 250 ml. 6 Sampling Sampling is not part of the method specified in this International Standard. A recommended sampling method is given in ISO 707|IDF 501. It is important that the laboratory receive a truly representative sample which has not been damaged or
30、 changed during transport or storage. 7 Preparation of test sample 7.1 Thoroughly mix the laboratory sample by repeatedly shaking and inverting the container (if necessary, after having transferred all of the laboratory sample to an airtight container of sufficient capacity to allow this operation t
31、o be carried out). 7.2 Transfer about 50 g of the thoroughly mixed laboratory sample to the test sieve (5.7). 7.3 If the 50 g portion passes through the sieve completely or almost completely, use for the determination the sample as prepared in 7.1. 7.4 Otherwise, grind the 50 g portion, using the gr
32、inding device (5.6), until it passes through the sieve. Immediately transfer all the sieved sample to an airtight container of sufficient capacity and mix thoroughly by repeatedly shaking and inverting. During these operations, take precautions to avoid any change in the water content of the product
33、. 7.5 After the test sample has been prepared, initiate the procedure (see Clause 8) as soon as possible. 8 Procedure 8.1 Calibration of pH meter Adjust the temperature of the buffer solution (4.1) to 20 C and calibrate the pH meter in accordance with the manufacturers instructions. The calibration
34、should be carried out while the flasks are standing for 20 min (see 8.2.1 and 8.2.2). If a series of samples is being tested, check the calibration of the pH meter with one or more of the standard buffer solutions at least every 30 min. BS ISO 5546:2010ISO 5546:2010(E) IDF 115:2010(E) ISO and IDF 20
35、10 All rights reserved 38.2 Preparation of test solution 8.2.1 Caseins Weigh, to the nearest 0,1 g, into the conical flask (5.4), 5,0 g of the test sample (see Clause 7), add 30 ml of water previously adjusted to 20 C and stopper the flask. (If desired, 7,0 g of the test sample and 42 ml of water ma
36、y be taken.) Shake the flask by hand for 10 s and allow to stand for 20 min at about 20 C. 8.2.2 Caseinates Transfer to the beaker (5.9) 95 ml of water, add 5,0 g of the test sample (see Clause 7), and mix using the mixer (5.8) for 30 s. Allow to stand for 20 min at about 20 C. 8.3 Measurement of pH
37、 8.3.1 Caseins Decant the supernatant liquid into the beaker (5.5) and immediately determine the pH of this liquid, using the pH meter (5.2), after having rinsed the glass electrode carefully with water. 8.3.2 Caseinates Pour about 20 ml of the solution into the beaker (5.5) and immediately determin
38、e the pH of this liquid, using the pH meter (5.2), after having rinsed the glass electrode carefully with water. 9 Expression of results 9.1 Caseins Record, as the pH of the aqueous extract of casein, the value read from the dial of the pH meter to at least one decimal place. 9.2 Caseinates Record,
39、as the pH of the aqueous solution of caseinate, the value read from the dial of the pH meter to at least two decimal places. 10 Precision 10.1 Repeatability The difference between two single results obtained on identical test material by one analyst using the same apparatus within a short time inter
40、val will exceed 0,1 pH unit for casein extracts and 0,05 pH unit for caseinate solutions on average not more than once in 20 cases in the normal and correct operation of the method. BS ISO 5546:2010ISO 5546:2010(E) IDF 115:2010(E) 4 ISO and IDF 2010 All rights reserved10.2 Reproducibility The differ
41、ence between two single and independent results obtained by two operators working in different laboratories on identical test material will exceed 0,3 pH unit for casein extracts and 0,15 pH unit for caseinate solutions on average not more than once in 20 cases in the normal and correct operation of
42、 the method. 11 Test report The test report shall contain at least the following information: a) all the information necessary for the complete identification of the sample; b) the sampling method used, if known; c) the test method used, including a reference to this International Standard (ISO 5546
43、|IDF 115:2010); d) any operating conditions not specified in this International Standard, or regarded as optional, as well as details of any incidents that may have influenced the result(s); e) the test result(s) obtained; f) if the repeatability has been checked, the final quoted result obtained. B
44、S ISO 5546:2010ISO 5546:2010(E) IDF 115:2010(E) ISO and IDF 2010 All rights reserved 5Bibliography 1 ISO 707|IDF 50, Milk and milk products Guidance on sampling 2 ISO 3310-1, Test sieves Technical requirements and testing Part 1: Test sieves of metal wire cloth BS ISO 5546:2010ISO 5546:2010(E) IDF 1
45、15:2010(E) ICS 67.100.99 Price based on 5 pages ISO and IDF 2010 All rights reserved BS ISO 5546:2010This page has been intentionally left blankBS ISO5546:2010BSI GroupHeadquarters 389Chiswick High Road,London, W4 4AL, UKTel +44 (0)20 8996 9001Fax +44 (0)20 8996 - British Standards InstitutionBSI i
46、s the independent national body responsible for preparing BritishStandards. It presents the UK view on standards in Europe and at theinternational level. It is incorporated by Royal Charter.RevisionsBritish Standards are updated by amendment or revision. Users of BritishStandards should make sure th
47、at they possess the latest amendments oreditions.It is the constant aim of BSI to improve the quality of our products and services.We would be grateful if anyone finding an inaccuracy or ambiguity while usingthis British Standard would inform the Secretary of the technical committeeresponsible, the
48、identity of which can be found on the inside front cover. Tel:+44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400.BSI offers members an individual updating service called PLUS which ensuresthat subscribers automatically receive the latest editions of standards.Buying standardsOrders for all BSI, internati
49、onal and foreign standards publications should beaddressed to Customer Services. Tel: +44 (0)20 8996 9001. Fax: +44 (0)20 89967001 Email: You may also buy directly using a debit/creditcard from the BSI Shop on the Website http:/ response to orders for international standards, it is BSI policy to supply theBSI implementation of those that have been published as British Standards,unless otherwise requested.Information on standardsBS
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1