1、BSI Standards PublicationBS ISO 6722-2:2013Road vehicles 60 V and 600V single-core cablesPart 2: Dimensions, test methods andrequirements for aluminium conductorcablesBS ISO 6722-2:2013 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of ISO 6722-2:2013.The UK particip
2、ation in its preparation was entrusted to TechnicalCommittee AUE/16, Electrical and electronic equipment.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are
3、responsible for its correctapplication. The British Standards Institution 2013. Published by BSI StandardsLimited 2013ISBN 978 0 580 69945 0ICS 43.040.10Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStand
4、ards Policy and Strategy Committee on 31 December 2013.Amendments issued since publicationDate Text affectedBS ISO 6722-2:2013 ISO 2013Road vehicles 60 V and 600 V single-core cables Part 2: Dimensions, test methods and requirements for aluminium conductor cablesVhicules routiers Cbles monoconducteu
5、rs de 60 V et 600 V Partie 2: Mthodes dessai des dimensions et exigences pour les cbles conducteurs en aluminiumINTERNATIONAL STANDARDISO6722-2Fourth edition2013-12-01Reference numberISO 6722-2:2013(E)BS ISO 6722-2:2013ISO 6722-2:2013(E)ii ISO 2013 All rights reservedCOPYRIGHT PROTECTED DOCUMENT ISO
6、 2013All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior written permission. Permission can be requ
7、ested from either ISO at the address below or ISOs member body in the country of the requester.ISO copyright officeCase postale 56 CH-1211 Geneva 20Tel. + 41 22 749 01 11Fax + 41 22 749 09 47E-mail copyrightiso.orgWeb www.iso.orgPublished in SwitzerlandBS ISO 6722-2:2013ISO 6722-2:2013(E) ISO 2013 A
8、ll rights reserved iiiContents PageForeword ivIntroduction v1 Scope . 12 Normative references 13 Terms and definitions . 14 General 14.1 Safety concerns . 14.2 Temperature classes . 24.3 Conductors . 24.4 Tests 24.5 General test conditions 34.6 Ovens . 34.7 Representative conductor sizes for testing
9、 44.8 Recommended colours. 45 Tests . 45.1 Outside cable diameter 45.2 Insulation thickness 55.3 Conductor diameter and cross-sectional area . 65.4 Conductor resistance . 85.5 Withstand voltage 95.6 Insulation faults . 95.7 Insulation volume resistivity 95.8 Pressure test at high temperature . 105.9
10、 Strip force . 105.10 Low temperature winding . 105.11 Cold impact . 105.12 Abrasion test 105.13 Long-term heat ageing, 3 000 h . 105.14 Short-term heat ageing, 240 h 105.15 Thermal overload 105.16 Shrinkage by heat 105.17 Resistance to chemicals 105.18 Durability of cable marking 105.19 Resistance
11、to ozone 105.20 Resistance to hot water 115.21 Temperature and humidity cycling 115.22 Resistance to flame propagation 11Annex A (informative) Conductor sizes and cable dimensions12Annex B (normative) Determination of temperature coefficients .14Bibliography .16BS ISO 6722-2:2013ISO 6722-2:2013(E)Fo
12、rewordISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a tech
13、nical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
14、 electrotechnical standardization.The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the different types of ISO documents should be noted. This document
15、was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives). Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such p
16、atent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations received (see www.iso.org/patents). Any trade name used in this document is information given for the convenience of users and does n
17、ot constitute an endorsement.For an explanation on the meaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISOs adherence to the WTO principles in the Technical Barriers to Trade (TBT) see the following URL: Foreword - Supplementary informatio
18、nThe committee responsible for this document is ISO/TC 22, Road vehicles, Subcommittee SC 3, Electrical and electronic equipment.This fourth edition of ISO 6722-2 cancels and replaces ISO 6722:2006.ISO 6722 consists of the following parts, under the general title Road vehicles 60 V and 600 V single-
19、core cables: Part 1: Dimensions, test methods and requirements for copper conductor cables Part 2: Dimensions, test methods and requirements for aluminium conductor cablesiv ISO 2013 All rights reservedBS ISO 6722-2:2013ISO 6722-2:2013(E)IntroductionISO 6722 deals with single-core cables, with coppe
20、r conductor cables covered in ISO 6722-1 and aluminium conductor cables covered in this part of ISO 6722. The performance of aluminium conductor cables is, in general, not to be expected to be the same as the performance of copper conductor cables in a one-to-one comparison basis. ISO 2013 All right
21、s reserved vBS ISO 6722-2:2013BS ISO 6722-2:2013Road vehicles 60 V and 600 V single-core cables Part 2: Dimensions, test methods and requirements for aluminium conductor cablesWARNING The use of this part of ISO 6722 may involve hazardous materials, operations, and equipment. This part of ISO 6722 d
22、oes not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this part of ISO 6722 to establish appropriate safety practices and determine the applicability of regulatory limitations prior to use.1 ScopeThis part of ISO 6722 specifie
23、s the dimensions, test methods, and requirements for single-core 60 V cables intended for use in road vehicle applications where the nominal system voltage is 60 V d.c. or 25 V a.c. It also specifies additional test methods and/or requirements for 600 V cables intended for use in road vehicle applic
24、ations, where the nominal system voltage is from 60 V d.c. or 25 V a.c. to 600 V d.c. or 600 V a.c. It also applies to individual cores in multi-core cables.This part of ISO 6722 specifies requirements for aluminium conductor cables.2 Normative referencesThe following documents, in whole or in part,
25、 are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.ISO 6722-1, Road vehicles 60 V and 600 V single-core
26、cables Part 1: Dimensions, test methods and requirements for copper conductor cablesISO 6892-1, Metallic materials Tensile testing Part 1: Method of test at room temperatureEN 573-1, Aluminium and aluminium alloys Chemical composition and form of wrought products Part 1: Numerical designation system
27、EN 573-3:2009, Aluminium and aluminium alloys Chemical composition and form of wrought products Part 3: Chemical composition and form of products3 Terms and definitionsFor the purposes of this document, the terms and definitions given in ISO 6722-1 apply.NOTE Whenever a.c. voltage is specified throu
28、ghout this part of ISO 6722, the a.c. rms value shall be used.4 General4.1 Safety concernsSee “WARNING” at the beginning of this part of ISO 6722.INTERNATIONAL STANDARD ISO 6722-2:2013(E) ISO 2013 All rights reserved 1BS ISO 6722-2:2013ISO 6722-2:2013(E)4.2 Temperature classesTemperature classes are
29、 defined in Table 1.Table 1 Temperature class ratingClass TemperatureA 40 C to 85 CB 40 C to 100 CC 40 C to 125 CD 40 C to 150 CE 40 C to 175 CF 40 C to 200 C4.3 ConductorsThe conductors shall consist of annealed or annealed compressed/compacted aluminium, aluminium alloy, or copper-cladded aluminiu
30、m strands. The specifications for the conductors shall be according to Table 2 and shall be completed by material specifications. Elongation requirements shall be established by the agreement between the customer and the supplier. The finished cable shall meet the resistance requirements of Table 5
31、for all conductors.The individual strands of the aluminium conductor shall be manufactured per 1 000 series aluminium, pursuant to EN 573-1. The chemical composition shall follow EN 573-3:2009, Table 1.NOTE Examples of strandings are shown in Table A.1. These strandings highlight examples of concept
32、ual configurations and are not intended to reflect any preferred constructions. Other stranding configurations may be used provided they meet the requirements specified and are agreed upon by the customer and the supplier.Table 2 Characteristics of individual single strand wire after annealingTensil
33、e strengtha,bRm MPaElongation at breakaAC%Conductivity 20Sm/mm270 to 120 16 35,590 to 140c,d8c,d33,5daDetermined pursuant to ISO 6892-1, (Reference 2).bMeasured at clamping length of 200 mm.cNot applicable for compressed conductors. The tensile strength, elongation, and chemical composition requirem
34、ents shall be established by the agreement between the customer and the supplier.dAdditional aluminium alloys may be used. The conductivity, tensile strength, elongation requirements, and chemical composition shall be established by the agreement between the customer and the supplier.4.4 TestsThe ca
35、bles shall be submitted to tests as specified in Table 3.Unintended direct contact of aluminium wire with any other metal shall not occur with any of the test methods.2 ISO 2013 All rights reservedBS ISO 6722-2:2013ISO 6722-2:2013(E)4.5 General test conditionsIf not otherwise specified, the device u
36、nder test (DUT) shall be preconditioned for at least 16 h at a room temperature (RT) of (23 5) C and a relative humidity (RH) of 45 % to 75 %. Unless otherwise specified, all tests other than “in-process” tests shall be conducted at these conditions.Where no tolerance is specified, all values shall
37、be considered to be approximate.When a.c. tests are performed, these shall be carried out at 50 Hz or 60 Hz. Applications at higher frequencies may require additional testing.4.6 OvensAn oven with air exchange, either natural or by pressure, should be used. The air shall enter the oven in such a way
38、 that it flows over the surface of the test pieces and leaves near the top of the oven. The oven shall have not less than 8 and not more than 20 complete air changes per hour at the specified ageing temperature.Forced air circulation, e.g. by a fan, inside the oven may be used. However, in case of d
39、ispute, an oven without forced air circulation shall be used.Table 3 TestsSubclause Test descriptionMandatory If requiredcIn-processaInitial PeriodicbInitial PeriodicbDimensions5.1 Outside cable diameter X X 5.2 Insulation thickness X X 5.3Conductor diameter and cross-sectional area X X X XElectrica
40、l characteristics5.4 Conductor resistance X X 5.5 Withstand voltage XdXd 5.6 Insulation faults Xd 5.7 Insulation volume resistivity X XMechanical characteristics5.8 Pressure test at high temperature X X 5.9 Strip force X XLow temperature characteris-tics5.10 Winding X X 5.11 Impact X X5.12 Resistanc
41、e to abrasion XeXe Heat ageing5.13 Long term ageing, 3 000 h X 5.14 Short-term ageing, 240 h X X 5.15 Thermal overload X X5.16 Shrinkage by heat X X Resistance to chemicals5.17 Fluid compatibility Xf,g Xf,g ISO 2013 All rights reserved 3BS ISO 6722-2:2013ISO 6722-2:2013(E)Subclause Test descriptionM
42、andatory If requiredcIn-processaInitial PeriodicbInitial Periodicb5.18 Durability of cable marking XgXg5.19 Resistance to ozone Xg5.20 Resistance to hot water Xg 5.21 Temperature and humidity cycling Xg5.22 Resistance to flame propagation X X X applicable test not applicableaA test made on entire ca
43、ble length during or after manufacture.bThe frequency of periodic testing shall be established by the agreement between the customer and the supplier.cThe usage of “if required” tests shall be established by the agreement between the customer and the supplier.dSome cables are rated at 60 V and other
44、s at 600 V. See ISO 6722-1 for details.eSee ISO 6722-1 for details.fSome fluids are for “certification” and others are “if required”. See ISO 6722-1 for details.gCompliance for a cable family may be demonstrated by testing the examples of large and small conduc-tor sizes only (see 4.7).4.7 Represent
45、ative conductor sizes for testingWhen a test is required, all combinations of conductor size, wall thickness, and insulation formulation shall meet the appropriate requirements. However, if the testing of representative conductor sizes is permitted (see Table 3), compliance for a cable family may be
46、 demonstrated by testing the examples of large and small conductor sizes only. Permission to show compliance for a cable family by testing “representative conductor sizes” shall be established by the agreement between the customer and the supplier.4.8 Recommended coloursFor a list of recommended col
47、ours, see ISO 6722-1.5 Tests5.1 Outside cable diameter5.1.1 Purpose, test sample, and testISO 6722-1 applies.5.1.2 RequirementNo single value shall be larger than the appropriate values specified in Table 4.NOTE See Table A.2 for the minimum outside cable diameters.Table 3 (continued)4 ISO 2013 All
48、rights reservedBS ISO 6722-2:2013ISO 6722-2:2013(E)5.2 Insulation thickness5.2.1 Purpose, test sample, and testISO 6722-1 applies.5.2.2 RequirementNo single value shall be less than the appropriate minimum insulation thickness specified in Table 4.Table 4 DimensionsISO conductoraThick wall Thin wall
49、 Ultrathin wallSize mm2Diameter mmInsulation thickness mmOutside cable diameter mmInsulation thickness mmOutside cable diameter mmInsulation thickness mmOutside cable diameter mmmax. nominal min. max. nominal min. max. nominal min. max.0,75 1,30 0,60 0,48 2,50 0,30 0,24 1,90 0,20 0,16 1,601 1,50 0,60 0,48 2,70 0,30 0,24 2,10 0,20 0,16 1,751,25 1,70 0,60 0,48 2,95 0,3