1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI British StandardsWB9423_BSI_StandardColCov_noK_AW:BSI FRONT COVERS 5/9/08 12:55 Page 1Passive components to beused in optical fibre communication systems Product specifications Part 2-1: SC(SC2)-PC c
2、onnector-type fixed opticalattenuators using IEC 60793-2 Category B1.1 singlemode fibrePD CLC/TR 50378-2-1:2009NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LANational forewordThis Published Document is the UK implementation of CLC/TR 50378-2-1:2008.The UK participation in its p
3、reparation was entrusted by Technical CommitteeGEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnectingdevices and passive components.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all t
4、he necessary provisions of acontract. Users are responsible for its correct application. BSI 2009ISBN 978 0 580 57685 0ICS 33.180.20Compliance with a British Standard cannot confer immunity fromlegal obligations.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDPD CLC/TR
5、50378-2-1:2009This British Standard was published under the authority of the StandardsPolicy and Strategy Committee on 31 January 2009. TECHNICAL REPORT CLC/TR 50378-2-1 RAPPORT TECHNIQUE TECHNISCHER BERICHT December 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen
6、de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. CLC/TR 50378-2-1:2008 E ICS 33.180.20
7、English version Passive components to be used in optical fibre communication systems - Product specifications - Part 2-1: SC(SC2)-PC connector-type fixed optical attenuators using IEC 60793-2 Category B1.1 singlemode fibre Composants passifs destins tre utiliss dans les systmes de communication par
8、fibres optiques - Spcifications de produit - Partie 2-1: Affaiblisseurs optiques fixes de type connecteur SC(SC2)-PC utilisant une fibre unimodale de la catgorie B1.1 de la CEI 60793-2 Passive Bauteile zur Verwendung in Lichtwellenleiter-Kommunikationssystemen - Produktnormen - Teil 2-1: Bauart SC(S
9、C2)-PC Steckverbinder mit optischem Dmpfungsglied zum Anschluss an Einmodenfasern der Kategorien B1.1 nach IEC 60793-2 This Technical Report was approved by CENELEC on 2008-06-20. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic,
10、Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. PD CLC/TR 50378-2-1:2009CLC/TR 50378-2-1:2008 - 2 - F
11、oreword This Technical Report was prepared by the Technical Committee CENELEC TC 86BXA, Fibre optic interconnect, passive and connectorised components. The text of the draft was circulated for voting in accordance with the Internal Regulations, Part 2, Subclause 11.4.3.3 (simple majority) and was ap
12、proved by CENELEC as CLC/TR 50378-2-1 on 2008-06-20. _ PD CLC/TR 50378-2-1:2009- 3 - CLC/TR 50378-2-1:2008 Passive components to be used in optical fibre communication systems Product specifications Part 2-1: SC(SC2)-PC connector-type fixed optical attenuators using IEC 60793-2 Category B1.1 singlem
13、ode fibre Description Performance Type: fixed Application: EN 61753-1:2007, Category U ES 201 286 (see 1.3) Style: plug style Operating wavelength: (1 260 - 1 360) nm and (1 460 - 1 625) nm Attenuation: 1 dB, 5 dB and 15 dB Coupling mechanism: push pull Configuration: plug-attenuator-adaptor-plug Fi
14、bre category: special fibre Return loss grade: W: 45 dB References: EN 50377-4-4 1)Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 4-4: Type SC-PC simplex terminated on IEC 60793-2-50 category B1.1, B1.3 and B6a singlemode
15、fibre, with full zirconia ferrule Category U EN 61300 series Fibre optic interconnection devices and passive components - Basic test and measurement procedures (IEC 61300 series) EN 61753-1 Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance
16、 for performance standards (IEC 61753-1) EN 61753-051-3 Fibre optic interconnecting devices and passive components performance standard - Part 051-3: Single-mode fibre, plug-style fixed attenuators for Category U - Uncontrolled environment (IEC 61753-051-3) EN 61755-1 Fibre optic connector optical i
17、nterfaces - Part 1: Optical interfaces for single mode non-dispersion shifted fibres - General and guidance (IEC 61755-1) ETSI ES 201 286 Transmission and Multiplexing (TM); Passive optical components; Connector-type optical fixed attenuators for single-mode optical fibre communications systems; Com
18、mon requirements and conformance testing ETSI EN 300 019 Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment Outline: 1)At draft stage. PD CLC/TR 50378-2-1:2009CLC/TR 50378-2-1:2008 - 4 - Contents 1 Scope . 5 2 Test samples 5 3 Test program 5
19、 3.1 Spectral attenuation loss (according to EN 61300-3-5). 5 3.2 Polarisation dependent loss (PDL) (according to EN 61300-3-2, option 1). 5 4 Test laboratories involved in this RRT . 5 5 Measurement results 6 5.1 Individual test laboratory results with reference connectors 6 5.1.1 Laboratory A resu
20、lts . 6 5.1.2 Laboratory B results . 8 5.1.3 Laboratory C results . 9 5.1.4 Laboratory D results . 10 5.1.5 Laboratory E results . 11 5.1.6 Laboratory F results . 13 5.1.7 Laboratory G results 15 5.2 Overview of all attenuation test results . 17 5.3 Attenuation measurements summary . 23 5.4 Attenuat
21、ion: Random mating versus reference connectors 24 5.5 Overview of PDL results 26 6 Mechanical interface issues with SC plug style attenuators 27 7 Conclusions 27 PD CLC/TR 50378-2-1:2009- 5 - CLC/TR 50378-2-1:2008 1 Scope This document reports the measurement results of a round robin test program ca
22、rried out on SC/PC plug style fixed attenuators. The work was initiated at CENELEC TC 86BXA meeting in June 2003 in order to get a clear understanding on the accuracy and repeatability of the spectral attenuation loss measurements on fixed attenuators. Out of these results some recommendations are m
23、ade for attenuation tolerance values that can be used in the performance standards. 2 Test samples In total 18 SC/PC plug style fixed attenuators were collected for this round robin test: - 6 attenuators with nominal attenuation of 15 dB (labelled 1, 2, 3, 4, 5 and 6); - 6 attenuators with nominal a
24、ttenuation of 5 dB (labelled 7, 8, 9, 10, 11 and 12); - 6 attenuators with nominal attenuation of 1 dB (labelled 13, 14, 15, 16, 17 and 18). The attenuators were obtained from various suppliers. The attenuating principle of all devices is based on the use of high attenuating fibre. The performance g
25、rade of these attenuators is defined as: - operating wavelength range: 1 260 nm-1 360 nm and 1 460 nm-1 580 nm; - attenuation tolerance: 0,5 dB for attenuators 5 dB, 10 % of nominal attenuation value for attenuators 5 dB. 3 Test program All participating test laboratories measured spectral attenuati
26、on and polarisation dependent loss for each attenuator. 3.1 Spectral attenuation loss (according to EN 61300-3-5) For the ease of the data processing the measured values were reported for the discrete wavelengths: 1 260 nm, 1 280 nm, 1 310 nm, 1 330 nm, 1 360 nm, 1 460 nm, 1 490 nm, 1 520 nm, 1 550
27、nm, 1 570 nm and 1 580 nm. The spectral width was set at 2 nm. Some laboratories also reported values with a spectral width of 10 nm. Each test laboratory performed the measurements with 2 sets of reference connectors and adapters: - measurements with common reference connectors and adapter (same re
28、ferences for all the test laboratories); - measurements with own test laboratory reference connectors and adapter. Uncertainty of each loss measurement at the above mentioned wavelength range was better than 0,1 dB. 3.2 Polarisation dependent loss (PDL) (according to EN 61300-3-2, option 1) PDL was
29、measured at 1 310 nm and 1 550 nm, with common reference connectors. The accuracy of each PDL measurement was better than 0,1 dB. 4 Test laboratories involved in this RRT The following laboratories were involved in this round robin test (in alphabetic order): - Adamant Kogyo Co. Ltd (Japan); - Diamo
30、nd (Switzerland); - Huber and Suhner (Switzerland); - Telekomunikacja Polska (Poland); - TILab (Telecom Italia Laboratories) (Italy); - Tyco Electronics-AMP (the Netherlands); - Tyco Electronics-Raychem (Belgium). PD CLC/TR 50378-2-1:2009CLC/TR 50378-2-1:2008 - 6 - 5 Measurement results 5.1 Individu
31、al test laboratory results with reference connectors 5.1.1 Laboratory A results Laboratory A made spectral attenuation measurements using two different light sources: a broadband LED and a tuneable laser in the 1 550 nm window. The results are given in Figure 1 (LED) and Figure 2 (LASER). PDL measur
32、ements at 1 310 nm and 1 550 nm are listed in Table 1. 15 dB Attenuators - Lab. A2 nm - Common ref - LED13.5014.0014.5015.0015.5016.0016.5017.0017.5018.001250 1350 1450 1550Wavelength (nm)Attenuation (dB)12345615 dB Attenuators - Lab. A2 nm - Lab ref - LED13.5014.0014.5015.0015.5016.0016.5017.0017.5
33、018.001250 1350 1450 1550Wavelength (nm)Attenuation (dB)1234565 dB Attenuators - Lab. A2 nm - Common ref - LED4.404.604.805.005.205.405.605.801250 1350 1450 1550Wavelength (nm)Attenuation (dB)7891011125 dB Attenuators - Lab. A2 nm - Lab ref - LED4.204.404.604.805.005.205.405.605.801250 1350 1450 155
34、0Wavelength (nm)Attenuation(dB)7891011121 dB Attenuators - Lab. A2 nm - Common ref - LED0.600.801.001.201.401250 1350 1450 1550Wavelength (nm)Attenuation (dB)1314151617181 dB Attenuators - Lab. A2 nm - Lab ref - LED0.600.801.001.201.401250 1350 1450 1550Wavelength (nm)Attenuation(dB)131415161718Figu
35、re 1 - Laboratory A results with 2 nm resolution (LED light source) PD CLC/TR 50378-2-1:2009- 7 - CLC/TR 50378-2-1:2008 15 dB Attenuators - Lab. A2 nm - Common ref - LASER14.0014.5015.0015.5016.0016.501250 1350 1450 1550Wavelength (nm)Attenuation (dB)12345615 dB Attenuators - Lab. A2 nm - Lab ref -
36、LASER14.0014.5015.0015.5016.0016.5017.001250 1350 1450 1550Wavelength (nm)Attenuation(dB)1234565 dB Attenuators - Lab. A2 nm - Common ref - LASER4.404.604.805.005.205.405.601250 1350 1450 1550Wavelength (nm)Attenuation (dB)7891011125 dB Attenuators - Lab. A2 nm - Lab ref - LASER4.204.404.604.805.005
37、.205.405.605.801250 1350 1450 1550Wavelength (nm)Attenuation (dB)7891011121 dB Attenuators - Lab. A2 nm - Common ref - LASER0.600.801.001.201.401250 1350 1450 1550Wavelength (nm)Attenuation (dB)1314151617181 dB Attenuators - Lab. A2 nm - Lab ref - LASER0.400.600.801.001.201.401250 1350 1450 1550Wave
38、length (nm)Attenuation (dB)131415161718Figure 2 - Laboratory A results with 2 nm resolution (LASER light source) Table 1 - PDL measurements from Laboratory A 123456789101121314151617181310 nm 0.75 0.21 0.07 0.08 0.01 0.03 0.01 0.01 0.01 0.01 0.01 0.01 0.02 0.01 0.01 0.05 0.02 0.021550 nm 0.12 0.03 0
39、.02 0.02 0.01 0.02 0.01 0.01 0.01 0.01 0.01 0.01 0.02 0.01 0.01 0.01 0.01 0.01LABORATORY A - PDL COMMON REFPD CLC/TR 50378-2-1:2009CLC/TR 50378-2-1:2008 - 8 - 5.1.2 Laboratory B results Laboratory B made spectral measurements with a 2 nm resolution. The attenuation results for all attenuators are sh
40、own in Figure 3 (2 nm resolution). PDL measurements at 1 310 nm and 1 550 nm are listed in Table 2. 15 dB Attenuators - Lab. B2 nm - Common ref13.5014.0014.5015.0015.5016.0016.5017.001250 1350 1450 1550Wavelength (nm)Attenuation (dB)12345615 dB Attenuators - Lab. B2 nm - Lab ref13.5014.0014.5015.001
41、5.5016.0016.5017.001250 1350 1450 1550Wavelength (nm)Attenuation (dB)1234565 dB Attenuators - Lab. B2 nm - Common ref4.404.604.805.005.205.405.605.806.001250 1350 1450 1550Wavelength (nm)Attenuation (dB)7891011125 dB Attenuators - Lab. B2 nm - Lab ref4.404.604.805.005.205.405.605.806.001250 1350 145
42、0 1550Wavelength (nm)Attenuation (dB)7891011121 dB Attenuators - Lab. B2 nm - Common ref0.600.801.001.201.401.601250 1350 1450 1550Wavelength (nm)Attenuation (dB)1314151617181 dB Attenuators - Lab. B2 nm - Lab ref0.600.801.001.201.401.601250 1350 1450 1550Wavelength (nm)Attenuation (dB)131415161718F
43、igure 3 - Laboratory B results with 2 nm resolution Table 2 - PDL measurements from Laboratory B 123456789101121314151617181310 nm 0.8 0.16 0.14 0.09 0.06 0.16 0.36 0.08 0.06 0.08 0.06 0.07 0.07 0.06 0.08 0.13 0.08 0.071550 nm 0.15 0.06 0.13 0.07 0.06 0.06 0.06 0.07 0.07 0.07 0.12 0.11 0.06 0.07 0.0
44、7 0.06 0.08 0.08LABORATORY B - PDL COMMON REFPD CLC/TR 50378-2-1:2009- 9 - CLC/TR 50378-2-1:2008 5.1.3 Laboratory C results Laboratory C made spectral attenuation measurements with a 2 nm resolution. The attenuation results for all attenuators are shown in Figure 4 (2 nm resolution). No PDL measurem
45、ents were made. 15 dB Attenuators - Lab. C2 nm - Common ref13.51414.51515.51616.51250 1350 1450 1550Wavelength (nm)Attenuation(dB)12345615 dB Attenuators - Lab. C2 nm - Lab ref13.51414.51515.51616.51250 1350 1450 1550Wavelength (nm)Attenuation(dB)1234565 dB Attenuators - Lab. C2 nm - Common ref4.54.
46、64.74.84.955.15.25.35.45.51250 1350 1450 1550Wavelength (nm)Attenuation (dB)7891011125 dB Attenuators - Lab. C2 nm - Lab ref4.54.64.74.84.955.15.25.35.45.51250 1350 1450 1550Wavelength (nm)Attenuation(dB)7891011121 dB Attenuators - Lab. C2 nm - Common ref0.60.811.21.41.61.81250 1350 1450 1550Wavelen
47、gth (nm )Attenuation(dB)1314151617181 dB Attenuators - Lab. C2 nm - Lab ref0.60.811.21.41.61.81250 1350 1450 1550Wavelength (nm)Attenuation(dB)131415161718Figure 4 - Laboratory C results with 2 nm resolution No PDL measurements were performed by laboratory C. PD CLC/TR 50378-2-1:2009CLC/TR 50378-2-1
48、:2008 - 10 - 5.1.4 Laboratory D results Laboratory D made spectral measurements with a 2 nm resolution. The attenuation results for all attenuators are shown in Figure 5 (2 nm resolution). PDL measurements at 1 310 nm and 1 550 nm are shown in Table 3. 15 dB Attenuators - Lab. D2 nm - Common ref13.5
49、1414.51515.51616.51250 1350 1450 1550Wavelength (nm)Attenuation(dB)12345615 dB Attenuators - Lab. D2 nm - Lab ref13.51414.51515.51616.51250 1350 1450 1550Wavelength (nm)Attenuation (dB)1234565 dB Attenuators - Lab. D2 nm - Common ref4.44.64.855.25.45.65.861250 1350 1450 1550Wavelength (nm)Attenuation (dB)7891011125 dB Attenuators - Lab. D2 nm - Lab ref4.44.64.855.25.45.65.861250 1350 1450 1550Wavelength (nm)Attenuation (dB)7891011121 dB Attenuators - Lab. D2 nm - Common ref0.80.911.11.21.31.41250 1350 1450 1550Wavelength (nm)Att