1、C22.2 No. 245-15Marine shipboard cableLegal Notice for StandardsCanadian Standards Association (operating as “CSA Group”) develops standards through a consensus standards development process approved by the Standards Council of Canada. This process brings together volunteers representing varied view
2、points and interests to achieve consensus and develop a standard. Although CSA Group administers the process and establishes rules to promote fairness in achieving consensus, it does not independently test, evaluate, or verify the content of standards.Disclaimer and exclusion of liabilityThis docume
3、nt is provided without any representations, warranties, or conditions of any kind, express or implied, including, without limitation, implied warranties or conditions concerning this documents fitness for a particular purpose or use, its merchantability, or its non-infringement of any third partys i
4、ntellectual property rights. CSA Group does not warrant the accuracy, completeness, or currency of any of the information published in this document. CSA Group makes no representations or warranties regarding this documents compliance with any applicable statute, rule, or regulation.IN NO EVENT SHAL
5、L CSA GROUP, ITS VOLUNTEERS, MEMBERS, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES, DIRECTORS, OR OFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES, HOWSOEVER CAUSED, INCLUDING BUT NOT LIMITED TO SPECIAL OR CONSEQUENTIAL DAMAGES, LOST
6、REVENUE, BUSINESS INTERRUPTION, LOST OR DAMAGED DATA, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS, WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR ANY OTHER THEORY OF LIABILITY, ARISING OUT OF OR RESULTING FROM ACCESS TO OR POSSESSION OR USE OF THIS DOCUMENT, EVEN IF CSA GROUP HAS BEEN ADVIS
7、ED OF THE POSSIBILITY OF SUCH DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES.In publishing and making this document available, CSA Group is not undertaking to render professional or other services for or on behalf of any person or entity or to perform any duty owed by any person or entity to another pers
8、on or entity. The information in this document is directed to those who have the appropriate degree of experience to use and apply its contents, and CSA Group accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained in this document.CSA
9、 Group is a private not-for-profit company that publishes voluntary standards and related documents. CSA Group has no power, nor does it undertake, to enforce compliance with the contents of the standards or other documents it publishes.Intellectual property rights and ownershipAs between CSA Group
10、and the users of this document (whether it be in printed or electronic form), CSA Group is the owner, or the authorized licensee, of all works contained herein that are protected by copyright, all trade-marks (except as otherwise noted to the contrary), and all inventions and trade secrets that may
11、be contained in this document, whether or not such inventions and trade secrets are protected by patents and applications for patents. Without limitation, the unauthorized use, modification, copying, or disclosure of this document may violate laws that protect CSA Groups and/or others intellectual p
12、roperty and may give rise to a right in CSA Group and/or others to seek legal redress for such use, modification, copying, or disclosure. To the extent permitted by licence or by law, CSA Group reserves all intellectual property rights in this document.Patent rightsAttention is drawn to the possibil
13、ity that some of the elements of this standard may be the subject of patent rights. CSA Group shall not be held responsible for identifying any or all such patent rights. Users of this standard are expressly advised that determination of the validity of any such patent rights is entirely their own r
14、esponsibility.Authorized use of this documentThis document is being provided by CSA Group for informational and non-commercial use only. The user of this document is authorized to do only the following:If this document is in electronic form: load this document onto a computer for the sole purpose of
15、 reviewing it; search and browse this document; and print this document if it is in PDF format.Limited copies of this document in print or paper form may be distributed only to persons who are authorized by CSA Group to have such copies, and only if this Legal Notice appears on each such copy.In add
16、ition, users may not and may not permit others to alter this document in any way or remove this Legal Notice from the attached standard; sell this document without authorization from CSA Group; or make an electronic copy of this document.If you do not agree with any of the terms and conditions conta
17、ined in this Legal Notice, you may not load or use this document or make any copies of the contents hereof, and if you do make such copies, you are required to destroy them immediately. Use of this document constitutes your acceptance of the terms and conditions of this Legal Notice.Standards Update
18、 ServiceC22.2 No. 245-15March 2015Title: Marine shipboard cableTo register for e-mail notification about any updates to this publication go to shop.csa.ca click on CSA Update ServiceThe List ID that you will need to register for updates to this publication is 2423352.If you require assistance, pleas
19、e e-mail techsupportcsagroup.org or call 416-747-2233.Visit CSA Groups policy on privacy at www.csagroup.org/legal to find out how we protect your personal information.ISBN 978-1-77139-737-7 2015 CSA Group All rights reserved. No part of this publication may be reproduced in any form whatsoever with
20、out the prior permission of the publisher.Published in March 2015 by CSA Group A not-for-profit private sector organization 178 Rexdale Boulevard, Toronto, Ontario, Canada M9W 1R3 To purchase standards and related publications, visit our Online Store at shop.csa.caor call toll-free 1-800-463-6727 or
21、 416-747-4044.TMA trade-mar k of the Canadian S tandards Association, operating as “CSA Group”Marine shipboard cableC22.2 No. 245-15C22.2 No. 245-15Marine shipboard cableMarch 2015 2015 CSA Group 1ContentsTechnical Committee on Wiring Products 3Subcommittee on Control, Instrument, Communication, and
22、 Marine Cables 5Preface 81 Scope 92 Reference publications 93 General requirements 124 Construction 124.1 Copper conductors 124.1.1 General 124.1.2 Stranding 124.1.3 Conductor stress control layer (for cables rated above 2 kV) 124.2 Insulation 134.2.1 General 134.2.2 Separator 134.2.3 Thickness of e
23、xtruded insulation 134.2.4 Properties of insulation 134.3 Insulation shield 144.4 Binder or separator 144.5 Braids 144.6 Conductor identification 144.7 Shielding 144.8 Individually shielded components and overall shielding 144.9 Bonding conductors 154.10 Cabling 154.11 Fillers 164.12 Cable jackets 1
24、64.12.1 General 164.12.2 Integral insulation/jacket (only applicable for X110 insulation) 174.12.3 Jacket thickness 174.13 Metal braid armour (optional) 174.13.1 General 174.13.2 Aluminum braid armour 184.13.3 Commercial bronze braid armour 184.13.4 Tinned copper braid armour 184.13.5 Stainless stee
25、l braid armour 184.14 Continuously welded corrugated aluminum sheath (optional) 184.15 Jacket over braid armour 184.16 Jacket over corrugated aluminum armour 195 Testing details and performance requirements of cable types 195.1 General 19C22.2 No. 245-15Marine shipboard cableMarch 2015 2015 CSA Grou
26、p 25.2 Manufacturing and production tests 195.2.1 Spark test (up to 2 kV unshielded cables) 195.2.2 Dielectric withstand test on finished cable (up to 2 kV cable) 195.2.3 Insulation resistance test on finished cable (up to 2 kV cables) 205.3 Qualification and capability tests 215.3.1 Low temperature
27、 bend test 215.3.2 Low temperature impact test 215.3.3 Sunlight/weather resistance test 215.3.4 Flame test 215.3.5 Ease of stripping test 225.3.6 Salt water immersion test 235.3.7 Oil compatibility test 235.3.8 Pulling through metal plates test 235.3.9 Bending endurance test (up to 2 kV) 255.3.10 Ha
28、logen content of nonmetallic components 255.3.11 Accelerated water absorption 256 Cable type and product markings 256.1 Cable identification 256.2 Package markings 26Annex A (informative) Recommended practice for colour code for control and signal cables* 42Annex B (informative) Recommended practice
29、 for colour code for twisted pair cables 43C22.2 No. 245-15Marine shipboard cableMarch 2015 2015 CSA Group 3Technical Committee on Wiring ProductsK.L. Rodel Hubbell Canada LP, Pickering, Ontario Category: Producer InterestChairP. Desilets Leviton Manufacturing of Canada Limited, Pointe-Claire, Qubec
30、 Category: Producer InterestVice-ChairW.J. Bryans Electro-Federation Canada, Toronto, Ontario AssociateW.J. Burr Burr and Associates, Campbell River, British Columbia Category: General InterestC. Davis Electro Cables Incorporated, Trenton, Ontario Category: Producer InterestS.W. Douglas Internationa
31、l Association of Electrical Inspectors, Toronto, Ontario Category: General InterestD. Drysdale Nexans Canada Inc., Milton, Ontario Category: Producer InterestS.P. Hawkins Shawflex, a Division of ShawCor Ltd., Toronto, Ontario AssociateR.J. Kelly Government of Nunavut, Department of Community b) prov
32、ide an explanation of circumstances surrounding the actual field condition; andc) where possible, phrase the request in such a way that a specific “yes” or “no” answer will address the issue.Committee interpretations are processed in accordance with the CSA Directives and guidelines governing standa
33、rdization and are available on the Current Standards Activities page at standardsactivities.csa.ca.5) This Standard is subject to review five years from the date of publication. Suggestions for its improvement will be referred to the appropriate committee. To submit a proposal for change, please sen
34、d the following information to inquiriescsagroup.org and include “Proposal for change” in the subject line: a) Standard designation (number);b) relevant clause, table, and/or figure number;c) wording of the proposed change; andd) rationale for the change.C22.2 No. 245-15Marine shipboard cableMarch 2
35、015 2015 CSA Group 9C22.2 No. 245-15Marine shipboard cable1 Scope1.1 This Standard specifies the requirements for distribution (power), control, and signal cables, for use aboard marine vessels and fixed and floating offshore drilling or production platforms, that area) rated up to 35 kV (AC or DC,
36、phase-to-phase) maximum;b) in single or multi-conductor constructions;c) with or without metal armour; andd) with or without an overall jacket.Cables rated up to 1 kv ac can be rated at 2.8 kV dc.1.2 The installations described in Clause 1.1 are designed to be installed in accordance with CSA C22.1,
37、 Canadian Electrical Code (CE Code), Part I.Note: Installation of cables is subject to requirements found in industry standards and local regulations.1.3 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the stan
38、dard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard.Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a not
39、e accompanying a clause is to separate from the text explanatory or informative material.Notes to tables and figures are considered part of the table or figure and may be written as requirements.Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.2
40、 Reference publicationsThis Standard refers to the following publications, and where such reference is made, it shall be to the edition listed below, including all amendments published thereto.CSA GroupC22.1-15 Canadian Electrical Code, Part ICAN/CSA-C22.2 No. 0-10 General requirements Canadian Elec
41、trical Code, Part IIC22.2 No. 245-15Marine shipboard cableMarch 2015 2015 CSA Group 10C22.2 No. 38-14 Thermoset-insulated wires and cablesC22.2 No. 75-14 Thermoplastic-insulated wires and cablesC22.2 No. 123-08 (R2012) Metal sheathed cablesC22.2 No. 124-04 (R2014) Mineral-insulated cableC22.2 No. 25
42、56-13 Wire and cable test methodsC68.10-14 Shielded power cable for commercial and industrial applications, 546 kVASTM InternationalB3-13 Standard Specification for Soft or Annealed Copper WireB8-11 Standard Specification for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or SoftB33-1
43、0 Standard Specification for Tin-Coated Soft or Annealed Copper Wire for Electrical PurposesB172-10 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical ConductorsB173-10 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Con
44、centric-Stranded Members, for Electrical ConductorsB174-10 Standard Specification for Bunch-Stranded Copper Conductors for Electrical ConductorsB189-05 (2010) Standard Specification for Lead-Coated and Lead-Alloy-Coated Soft Copper Wire for Electrical PurposesB286-07 (2012) Standard Specification fo
45、r Copper Conductors for Use in Hookup Wire for Electronic EquipmentB496-14 Standard Specification for Compact Round Concentric-Lay-Stranded Copper ConductorsC22.2 No. 245-15Marine shipboard cableMarch 2015 2015 CSA Group 11B784-01 (2012) Standard Specification for Modified Concentric-Lay-Stranded Co
46、pper Conductors for Use in Insulated Electrical CablesB787/B787M-2004 (2009) Standard Specification for 19 Wire Combination Unilay-Stranded Copper Conductors for Subsequent InsulationICEA/NEMA (Insulated Cable Engineers Association/ National Electrical Manufacturers Association)ICEA S-82-552/NEMA WC
47、 55-1992 (withdrawn) Instrumentation Cables and Thermocouple WireICEA S-73-532/NEMA WC 57-2004 Standard for Control, Thermocouple Extension, and Instrumentation CablesIEC (International Electrotechnical Commission)60228:2004 Conductors of insulated cables60331-11:1999+A1:2009 Tests for electric cabl
48、es under fire conditions Circuit integrity Part 11: Apparatus Fire alone at a flame temperature of at least 750 C60331-21:1999 Tests for electric cables under fire conditions Circuit integrity Part 21: Procedures and requirements Cables of rated voltage up to and including 0,6/1,0 kV60331-23:1999 Te
49、sts for electric cables under fire conditions Circuit integrity Part 23: Procedures and requirements Electric data cables60331-25:1999 Tests for electric cables under fire conditions Circuit integrity Part 25: Procedures and requirements Optical fibre cablesUL (Underwriters Laboratories Inc.)UL 2196 (2001) Tests for Fire Resistive CablesU.S. Department of DefenseMIL-DTL-24643C Supplement 1A (2011) Detail Specification Cables, Electric, Low Smoke Halogen-Free, for Shipboard Use, General Specification forC22.2 No. 245-15Marine ship