1、C22.2 No. 37-14Decorative lighting productsLegal Notice for StandardsCanadian Standards Association (operating as “CSA Group”) develops standards through a consensus standards development process approved by the Standards Council of Canada. This process brings together volunteers representing varied
2、 viewpoints and interests to achieve consensus and develop a standard. Although CSA Group administers the process and establishes rules to promote fairness in achieving consensus, it does not independently test, evaluate, or verify the content of standards.Disclaimer and exclusion of liabilityThis d
3、ocument is provided without any representations, warranties, or conditions of any kind, express or implied, including, without limitation, implied warranties or conditions concerning this documents fitness for a particular purpose or use, its merchantability, or its non-infringement of any third par
4、tys intellectual property rights. CSA Group does not warrant the accuracy, completeness, or currency of any of the information published in this document. CSA Group makes no representations or warranties regarding this documents compliance with any applicable statute, rule, or regulation.IN NO EVENT
5、 SHALL CSA GROUP, ITS VOLUNTEERS, MEMBERS, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES, DIRECTORS, OR OFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES, HOWSOEVER CAUSED, INCLUDING BUT NOT LIMITED TO SPECIAL OR CONSEQUENTIAL DAMAGES,
6、LOST REVENUE, BUSINESS INTERRUPTION, LOST OR DAMAGED DATA, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS, WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR ANY OTHER THEORY OF LIABILITY, ARISING OUT OF OR RESULTING FROM ACCESS TO OR POSSESSION OR USE OF THIS DOCUMENT, EVEN IF CSA GROUP HAS BEEN
7、ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES.In publishing and making this document available, CSA Group is not undertaking to render professional or other services for or on behalf of any person or entity or to perform any duty owed by any person or entity to another
8、 person or entity. The information in this document is directed to those who have the appropriate degree of experience to use and apply its contents, and CSA Group accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained in this documen
9、t.CSA Group is a private not-for-profit company that publishes voluntary standards and related documents. CSA Group has no power, nor does it undertake, to enforce compliance with the contents of the standards or other documents it publishes.Intellectual property rights and ownershipAs between CSA G
10、roup and the users of this document (whether it be in printed or electronic form), CSA Group is the owner, or the authorized licensee, of all works contained herein that are protected by copyright, all trade-marks (except as otherwise noted to the contrary), and all inventions and trade secrets that
11、 may be contained in this document, whether or not such inventions and trade secrets are protected by patents and applications for patents. Without limitation, the unauthorized use, modification, copying, or disclosure of this document may violate laws that protect CSA Groups and/or others intellect
12、ual property and may give rise to a right in CSA Group and/or others to seek legal redress for such use, modification, copying, or disclosure. To the extent permitted by licence or by law, CSA Group reserves all intellectual property rights in this document.Patent rightsAttention is drawn to the pos
13、sibility that some of the elements of this standard may be the subject of patent rights. CSA Group shall not be held responsible for identifying any or all such patent rights. Users of this standard are expressly advised that determination of the validity of any such patent rights is entirely their
14、own responsibility.Authorized use of this documentThis document is being provided by CSA Group for informational and non-commercial use only. The user of this document is authorized to do only the following:If this document is in electronic form: load this document onto a computer for the sole purpo
15、se of reviewing it; search and browse this document; and print this document if it is in PDF format.Limited copies of this document in print or paper form may be distributed only to persons who are authorized by CSA Group to have such copies, and only if this Legal Notice appears on each such copy.I
16、n addition, users may not and may not permit others to alter this document in any way or remove this Legal Notice from the attached standard; sell this document without authorization from CSA Group; or make an electronic copy of this document.If you do not agree with any of the terms and conditions
17、contained in this Legal Notice, you may not load or use this document or make any copies of the contents hereof, and if you do make such copies, you are required to destroy them immediately. Use of this document constitutes your acceptance of the terms and conditions of this Legal Notice.Standards U
18、pdate ServiceC22.2 No. 37-14November 2014Title: Decorative lighting productsTo register for e-mail notification about any updates to this publication go to shop.csa.ca click on CSA Update ServiceThe List ID that you will need to register for updates to this publication is 2423464.If you require assi
19、stance, please e-mail techsupportcsagroup.org or call 416-747-2233.Visit CSA Groups policy on privacy at csagroup.org/legal to find out how we protect your personal information.ISBN 1-978-77139-833-6 2014 CSA Group All rights reserved. No part of this publication may be reproduced in any form whatso
20、ever without the prior permission of the publisher.Published in November 2014 by CSA Group A not-for-profit private sector organization 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N6 To purchase standards and related publications, visit our Online Store at shop.csa.caor call toll
21、-free 1-800-463-6727 or 416-747-4044.TMA trade-mar k of the Canadian S tandards Association, operating as “CSA Group”Decorative lighting productsC22.2 No. 37-14C22.2 No. 37-14Decorative lighting productsNovember 2014 2014 CSA Group 1ContentsTechnical Committee on Consumer and Commercial Products 5In
22、tegrated Committee on Lighting Products (ICLP) 7Preface 131 Scope 152 Reference publications 163 Definitions 194 General 245 General requirements 245.1 Mechanical construction 245.1.1 General 245.1.2 Decorative parts 245.1.3 Mechanical assembly 255.1.4 Enclosures 255.2 Electrical construction 305.2.
23、1 General 305.2.2 Overcurrent protection 325.2.3 Accessibility of live parts 335.2.4 Supply connections 345.2.5 Flexible cords and conductors 345.2.6 Wiring devices 355.2.7 Polarization 365.2.8 Terminals and conductive parts 385.2.9 Spacings 385.2.10 Splices 395.2.11 LVLE circuits 395.2.12 Switches
24、405.2.13 Printed circuit boards 415.2.14 Lamps 415.2.15 Lamping 415.2.16 Fuseholders and fused attachment plugs 425.2.17 Devices employing insulation-piercing terminals 425.3 Outdoor locations 425.4 Commercial use product 435.4.1 Commercial indoor use product 435.4.2 Commercial outdoor use product 4
25、35.5 Motorized devices 445.6 Direct plug-in units Supplementary requirements 445.7 Products with battery chargers 465.8 Tests for all products excluding ornaments and rope lighting systems 465.8.1 General 46C22.2 No. 37-14Decorative lighting productsNovember 2014 2014 CSA Group 25.8.2 Leakage curren
26、t test 465.8.3 Humidity conditioning 485.8.4 Test voltage and input rating 495.8.5 Temperature test 495.8.6 Stability test 545.8.7 Dielectric voltage-withstand test 545.8.8 Strain relief test and wire pull test 555.8.9 Wire re-insertion test 565.8.10 Abnormal operation test 565.8.11 Decorative part
27、flammability test 575.8.12 Conductivity of decorative parts test 585.8.13 Insulation-piercing terminal tests 585.8.14 Abnormal tests for controllers 605.9 Additional tests for products with polymeric enclosures 615.9.1 General 615.9.2 Mould stress-relief test 625.9.3 Drop test 625.9.4 Impact test 62
28、5.9.5 Cold Impact test 635.9.6 Enclosure resistance to crushing test 635.9.7 Adhesive test 635.10 Tests for products employing overcurrent protective devices 635.10.1 General 635.10.2 Overcurrent test 635.10.3 Fault current test 645.10.4 Fuseholder temperature test 645.10.5 Lampholder and fuseholder
29、 resistance to crushing 665.10.6 Fuseholder cover test 665.11 Additional tests for wiring devices 665.11.1 General 665.11.2 Strain relief test for wiring devices 665.11.3 Conductor secureness test 675.11.4 Blade security test 675.11.5 Insulation secureness test 675.12 Additional tests for products i
30、ntended for outdoor locations 685.12.1 General 685.12.2 Rain test 685.12.3 Immersion test 695.12.4 Gasket tests 705.12.5 Gasket adhesion test 715.13 Additional tests for direct plug-in units 725.13.1 General 725.13.2 Plug blades loading test 725.14 Test apparatus 725.14.1 Articulate probe 725.14.2 R
31、ain test apparatus 745.14.3 Cotton 765.15 Manufacturing and production test 765.15.1 Production line dielectric voltage-withstand test 76C22.2 No. 37-14Decorative lighting productsNovember 2014 2014 CSA Group 35.15.2 Production line polarization continuity test 765.15.3 Production line operation tes
32、ts 775.15.4 Production line grounding continuity test 775.15.5 Production line standing water immersion test 775.15.6 Production line attachment plug and load fitting test 785.15.7 Production line lampholder test 785.16 Ratings 785.17 Markings 785.17.1 General 785.17.2 Product markings 795.17.3 Prod
33、uct and cord tag markings 795.17.4 Cord tag markings 805.17.5 Carton/stuffer sheet/product/cord tag markings 845.17.6 Retail packaging 855.18 Instruction manual 865.18.1 General 865.18.2 Safety Instructions 875.18.3 Use and care instructions 895.18.4 User servicing instructions 905.18.5 Instructions
34、 for externally shunted products 925.18.6 Instructions to connect multiple products 926 Decorative lighting strings 936.1 Lampholders 936.2 Series-connected lampholders 946.2.1 General 946.2.2 Miniature screw-base (E10) lampholder 946.2.3 Midget screw-base (E5) lampholder 956.2.4 Push-in lampholder
35、956.2.5 Lampholders for non-replaceable lamps 956.2.6 Outdoor locations 956.2.7 Parallel-connected lampholders 966.3 Series-connected strings Supplementary requirements 966.4 Parallel-connected strings 966.4.1 Supplementary requirements 966.5 Additional tests for products with series-connected lamph
36、olders 976.5.1 General 976.5.2 Oven test 976.5.3 Lampholder strain relief tests 976.5.4 Lamp temperature test for external shunted sets 1026.5.5 Mechanical contact make and break test 1036.5.6 External shunt input test 1036.5.7 Series-connected lighting string rain test 1046.6 Additional tests for d
37、ecorative lighting strings 1056.6.1 Flexing 1056.6.2 Temperature after flexing test 1077 Decorative lighting outfits (silhouettes) 1087.1 General requirements 108C22.2 No. 37-14Decorative lighting productsNovember 2014 2014 CSA Group 47.2 Additional requirements for decorative outfits 1097.2.1 Gener
38、al 1097.2.2 Light sculptures 1107.2.3 Frame 1107.2.4 Flexing test for motorized devices 1117.2.5 Slip-ring endurance test 1117.2.6 Additional tests for motorized devices 1127.3 Additional requirements for ornaments 1127.3.1 General 1127.3.2 Additional tests for electronic ornaments 1137.3.3 Addition
39、al tests for non-electronic ornaments 1188 Artificial trees and tree stands 1208.1 General 1208.2 Additional tests for artificial trees and tree stands 1208.2.1 General 1208.2.2 Stability test 1218.2.3 Overflow test 121Annex A (normative) Lamps for decorative lighting products 122Annex B (normative)
40、 Parallel connected lampholders for decorative lighting products 127Annex C (normative) Printed circuit boards (PCB) 131Annex D (normative) Flexible light cable systems (rope lights) 136Annex E (normative) Markings French translations 171Annex F (informative) Metric conversion information table 178C
41、22.2 No. 37-14Decorative lighting productsNovember 2014 2014 CSA Group5Technical Committee on Consumer and Commercial ProductsA. Milne 21st Olympiad Sales, Burlington, Ontario Category: General InterestChairD. Mascarenhas Brampton, Ontario Category: General InterestVice-ChairD.P. Badry Government of
42、 Yukon, Whitehorse, Yukon Category: Regulatory AuthorityG. Benjamin Thomas andb) CSA TIL No. B-39, Flexible Light Cable Systems.For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0 General requirements Canadian Electrical Code, Par
43、t II.This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard.This Standard was prepared by the Integrated Committee on Lighting Products (ICLP) under the jurisdiction of the Technical Committee on Consumer and Commercial Products and the Strateg
44、ic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee.Interpretations: The Strategic Steering Committee on Requirements for Electrical Safety has provided the following direction for the interpretation of standards under its jurisdicti
45、on: “The literal text shall be used in judging compliance of products with the safety requirements of this Standard. When the literal text cannot be applied to the product, such as for new materials or construction, and when a relevant committee interpretation has not already been published, CSAs pr
46、ocedures for interpretation shall be followed to determine the intended safety principle.”Notes: 1) Use of the singular does not exclude the plural (and vice versa) when the sense allows.2) Although the intended primary application of this Standard is stated in its Scope, it is important to note tha
47、t it remains the responsibility of the users of the Standard to judge its suitability for their particular purpose.3) This Standard was developed by consensus, which is defined by CSA Policy governing standardization Code of good practice for standardization as “substantial agreement. Consensus impl
48、ies much more than a simple majority, but not necessarily unanimity”. It is consistent with this definition that a member may be included in the Technical Committee list and yet not be in full agreement with all clauses of this Standard.4) To submit a request for interpretation of this Standard, ple
49、ase send the following information to inquiriescsagroup.org and include “Request for interpretation” in the subject line: a) define the problem, making reference to the specific clause, and, where appropriate, include an illustrative sketch;b) provide an explanation of circumstances surrounding the actual field condition; andc) where possible, phrase the request in such a way that a specific “yes” or “no” answer will address the issue. Committee interpretations are processed in accordance with the CSA Directives and guidelines governing standa