1、 T568.1-3-05(ANSI/TIA-568-B.1-3-2003)Commercial building telecommunications cabling standard Part 1: General requirements Addendum 3 Supportable distances and channel attenuation for optical fiber applications by fiber type CSA Standard T568.1-3-05 (ANSI/TIA-568-B.1-3-2003) Commercial building telec
2、ommunications cabling standard Part 1: General requirements Addendum 3 Supportable distances and channel attenuation for optical fiber applications by fiber type Published in May 2005 by Canadian Standards Association A not-for-profit private sector organization 5060 Spectrum Way, Suite 100, Mississ
3、auga, Ontario, Canada L4W 5N61-800-463-6727 416-747-4044 Visit our Online Store at www.ShopCSA.ca Commercial building telecommunications cabling standard Part 1: General requirements Addendum 3 Supportable distances T568.1-3-05 and channel attenuation for optical fiber applications by fiber type CSA
4、/2 Canadian Standards Association May 2005 T568.1-3-05 Commercial building telecommunications cabling standard Part 1: General requirements Addendum 3 Supportable distances and channel attenuation for optical fiber applications by fiber type CSA Preface This is the first edition of CSA T568.1-3, Com
5、mercial building telecommunications cabling standard Part 1: General requirements Addendum 3 Supportable distances and channel attenuation for optical fiber applications by fiber type. This Standard is an adoption of the identically titled ANSI/TIA (American National Standards Institute/Telecommunic
6、ations Industry Association) Standard 568-B.1-3-2003 and is the product of the Telecommunications Industry Association TR-42 Technical Committee, which included a number of Canadian members in order to ensure that Canadian perspectives and requirements were addressed. It is written in SI (metric) un
7、its with yard/pound (imperial) units in parentheses. This Standard has been adopted with no technical deviations. Where code requirements or regulations necessitate changes from US to Canadian references, they should be made by the user, as follows: (a) Throughout this Standard, replace the term “Am
8、erican” with “Canadian”, as applicable. (b) Throughout this Standard, replace the term “state” with “provincial or territorial”, as applicable. (c) Throughout this Standard, replace “NEC” with “CE Code, Part I” (Canadian Electrical Code), as applicable. In addition, (i) where reference is made to “c
9、onduit”, replace it with “conduit/EMT” (electrical metallic tubing) because, in accordance with the Canadian Electrical Code, Part I, EMT is not considered a type of conduit; and (ii) the definitions of the following terms are to be taken from the Canadian Electrical Code, Part I: “Bonding”, “Ground
10、”, and “Raceway”. (d) Throughout this Standard, where reference is made to “FCC”, replace it with “CRTC” (Canadian Radio-television and Telecommunications Commission), or “Industry Canada”, as applicable. (e) The following Standards, published by the Canadian Standards Association, are adoptions of
11、TIA/EIA Standards. The requirements of these CSA Standards take precedence over the TIA/EIA Standards on which they are based; any reference in CSA T568.1-3 to the TIA/EIA Standard is to be replaced by a reference to the equivalent Canadian Standard: (i) T568.1-05, Commercial building telecommunicat
12、ions cabling standard Part 1: General requirements; and (ii) T568.3-05, Optical fiber cabling components standard. (f) Throughout this Standard, replace the term “Listed” with “Approved as applied to electrical equipment”.Commercial building telecommunications cabling standard Part 1: General requir
13、ements Addendum 3 Supportable distances T568.1-3-05 and channel attenuation for optical fiber applications by fiber type May 2005 Canadian Standards Association CSA/3 This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Telecommunications Wiring Systems, under the juris
14、diction of the Strategic Steering Committee on Information and Communications Technology, and has been formally approved by the Technical Committee. A list of the members of the Technical Committee is available upon request. May 2005 Canadian Standards Association 2005 All rights reserved. No part o
15、f this publication may be reproduced in any form whatsoever without the prior permission of the publisher. TIA material is reprinted with permission. Inquiries regarding this CSA Standard should be addressed to Canadian Standards Association 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada
16、 L4W 5N6 1-800-463-6727 416-747-4044 www.csa.ca TIA STANDARD ANSI/TIA-568-B.1-3-2003 Approved: February 25, 2003 Commercial Building Telecommunications Cabling Standard Part 1: General Requirements Addendum 3 Supportable Distances and Channel Attenuation for Optical Fiber Applications by Fiber Type
17、TIA-568-B.1-3 (Addendum No. 3 to TIA/EIA-568-B.1) FEBRUARY 2003 TELECOMMUNICATIONS INDUSTRY ASSOCIATION Representing the telecommunications industry in association with the Electronic Industries Alliance NOTICE TIA Engineering Standards and Publications are designed to serve the public interest thro
18、ugh eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for their particular need. The existence of such Standards and Publication
19、s shall not in any respect preclude any member or non-member of TIA from manufacturing or selling products not conforming to such Standards and Publications. Neither shall the existence of such Standards and Publications preclude their voluntary use by Non-TIA members, either domestically or interna
20、tionally. Standards and Publications are adopted by TIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, TIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Standard or Publication
21、. Further details of the development process are available in the TIA Engineering Manual, located at http:/www.tiaonline.org/standards/sfg/engineering_manual.cfm This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the
22、 responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. (From Standards Proposal No. 3-4425-AD3, formulated under the cognizance of the TIA TR-42.8 Subcommittee on Telecommunication
23、s Optical Fiber Cabling Systems.) Published by TELECOMMUNICATIONS INDUSTRY ASSOCIATION 2003 Standards and Technology Department 2500 Wilson Boulevard Arlington, VA 22201 U.S.A. All rights reserved NOTICE OF DISCLAIMER AND LIMITATION OF LIABILITY The document to which this Notice is affixed (the “Doc
24、ument”) has been prepared by one or more Engineering Committees or Formulating Groups of the Telecommunications Industry Association (“TIA”). TIA is not the author of the Document contents, but publishes and claims copyright to the Document pursuant to licenses and permission granted by the authors
25、of the contents. TIA Engineering Committees and Formulating Groups are expected to conduct their affairs in accordance with the TIA Engineering Manual (“Manual”), the current and predecessor versions of which are available at http:/www.tiaonline.org/standards/sfg/engineering_manual.cfm. TIAs functio
26、n is to administer the process, but not the content, of document preparation in accordance with the Manual and, when appropriate, the policies and procedures of the American National Standards Institute (“ANSI”). TIA does not evaluate, test, verify or investigate the information, accuracy, soundness
27、, or credibility of the contents of the Document. In publishing the Document, TIA disclaims any undertaking to perform any duty owed to or for anyone. The use or practice of contents of this Document may involve the use of intellectual property rights (“IPR”), including pending or issued patents, or
28、 copyrights, owned by one or more parties. TIA makes no search or investigation for IPR. When IPR consisting of patents and published pending patent applications are claimed and called to TIAs attention, a statement from the holder thereof is requested, all in accordance with the Manual. TIA takes n
29、o position with reference to, and disclaims any obligation to investigate or inquire into, the scope or validity of any claims of IPR. TIA does not enforce or monitor compliance with the contents of the Document. TIA does not certify, inspect, test or otherwise investigate products, designs or servi
30、ces or any claims of compliance with the contents of the Document. ALL WARRANTIES, EXPRESS OR IMPLIED, ARE DISCLAIMED, INCLUDING WITHOUT LIMITATION, ANY AND ALL WARRANTIES CONCERNING THE ACCURACY OF THE CONTENTS, ITS FITNESS OR APPROPRIATENESS FOR A PARTICULAR PURPOSE OR USE, ITS MERCHANTABILITY AND
31、 ITS NON-INFRINGEMENT OF ANY THIRD PARTYS INTELLECTUAL PROPERTY RIGHTS. TIA EXPRESSLY DISCLAIMS ANY AND ALL RESPONSIBILITIES FOR THE ACCURACY OF THE CONTENTS AND MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE CONTENTS COMPLIANCE WITH ANY APPLICABLE STATUTE, RULE OR REGULATION, OR THE SAFETY OR
32、 HEALTH EFFECTS OF THE CONTENTS OR ANY PRODUCT OR SERVICE REFERRED TO IN THE DOCUMENT OR PRODUCED OR RENDERED TO COMPLY WITH THE CONTENTS. TIA SHALL NOT BE LIABLE FOR ANY AND ALL DAMAGES, DIRECT OR INDIRECT, ARISING FROM OR RELATING TO ANY USE OF THE CONTENTS CONTAINED HEREIN, INCLUDING WITHOUT LIMI
33、TATION ANY AND ALL INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF BUSINESS, LOSS OF PROFITS, LITIGATION, OR THE LIKE), WHETHER BASED UPON BREACH OF CONTRACT, BREACH OF WARRANTY, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY OR OTHERWISE, EVEN IF ADVISED OF THE
34、 POSSIBILITY OF SUCH DAMAGES. THE FOREGOING NEGATION OF DAMAGES IS A FUNDAMENTAL ELEMENT OF THE USE OF THE CONTENTS HEREOF, AND THESE CONTENTS WOULD NOT BE PUBLISHED BY TIA WITHOUT SUCH LIMITATIONS. PLEASE! DONT VIOLATE THE LAW! This document is copyrighted by the TIA and may not be reproduced witho
35、ut prior permission of the Telecommunications Industry Association. For information consult our website at http:/www.tiaonline.org/about/faqDetail.cfm?id=18 Organizations may obtain permission to reproduce a limited number of copies through entering into a license agreement. For information, contact
36、: Global Engineering Documents 15 Inverness Way East Englewood, CO 80112-5704 U.S.A. or call U.S.A. and Canada 1-800-854-7179, International (303) 397-7956 TIA-568-B.1-3 Supportable Distances And Channel Attenuation For Optical Fiber Applications By Fiber Type, Addendum 3 To ANSI/TIA/EIA-568-B.1 Tab
37、le of Contents 1 INTRODUCTION . 1 2 SCOPE 1 3 TABLE ADDENDUM 2 List of Tables Table 1: Supportable distances and channel attenuation for optical fiber applications by fiber type 2 iTIA-568-B.1-3 1 INTRODUCTION At the request of the TR-42.1 Subcommittee on Commercial Building Cabling, the supportable
38、 distances and channel attenuation for optical fiber applications by fiber type within ANSI/TIA/EIA-568-B.1, table E-1 has been under review by the TR-42.8 Telecommunications Optical Fiber Cabling Systems Subcommittee. The purpose of this addendum, as a result of their research, is to supplement tab
39、le E-1, supportable distances and channel attenuation for optical fiber applications by fiber type, of ANSI/TIA/EIA-568-B.1. 2 SCOPE This addendum applies to the supportable distances and channel attenuation for optical fiber applications by fiber type. This addendum supplements the information cont
40、ained in table E-1. Two new applications (10/100BASE-SX and 10G Ethernet) and one new fiber type (850-nm laser-optimized 50/125-m multimode fiber) are addressed in table 1. 1TIA-568-B.1-3 23 TABLE ADDENDUM Table 1 Supportable distances and channel attenuation for optical fiber applications by fiber
41、type Maximum Supportable Distance1(m) Maximum Channel Attenuation1 (dB) Multimode2Multimode2Application Wave Length (nm) 62.5/125 m 50/125 m 850-nm Laser-Optimized 50/125 m3Single-mode962.5/125 m 50/125 m 850-nm Laser- Optimized 50/125 m3Single-mode 10/100BASE-SX 850 300 300 300 NST 4.0 4.0 4.0 NST
42、10G Ethernet10GBASE-S 850 264825300 NST 2.66,72.36,82.6 NST 10GBASE-L 1310 NST NST NST 100009NST NST NST 6.0 10GBASE-E 1550 NST NST NST 40000 NST NST NST 11.01010GBASE-LX4 1300 300 30011300 - 2.56,122.06,122.06,12- 10GBASE-LX4 1310 - - - 10000 - - - 6.661“NST” (non-standard) entries indicate where t
43、his standard does not recognize use of the media, but where equipment may be available to convert the native application signals to a form compatible with the non-native media. 2Specifications shown in this table are for TIA-568-B.1 recognized fiber types. Specifications for other non-recognized typ
44、es of fibers are included in these footnotes where applicable. 3850-nm laser-optimized 50/125 m multimode fiber supports the same maximum channel distances and insertion losses as 500/500 MHzkm 50/125 m multimode fiber for applications specified within TIA-568-B.1. 4For 62.5/125 m fiber, IEEE specif
45、ies 26 m (85 ft) for fiber with 160/500 MHzkm modal bandwidth and 33 m (108 ft) for fiber with 200/500 MHzkm modal bandwidth. 5For 50/125 m fiber, IEEE specifies 66 m (216 ft) for fiber with 400/400 MHzkm modal bandwidth and 82 m (269 ft) for fiber with 500/500 MHzkm modal bandwidth. 6Includes maxim
46、um channel insertion loss plus additional allowable insertion loss. 7For 62.5/125 m multimode fiber, IEEE specifies 2.6 dB for fiber with 160/500 MHzkm modal bandwidth and 2.5 dB for fiber with 200/500 MHzkm modal bandwidth. 8For 50/125 m multimode fiber, IEEE specifies 2.2 dB for fiber with 400/400
47、 MHzkm modal bandwidth and 2.3 dB for fiber with 500/500 MHzkm modal bandwidth. 9Channels are specified within TIA-568-B.1 up to 3 km (9840 ft). Distances provided within this table are the maximum distances specified within IEEE 802.3 and invoke cabling specifications that may differ from TIA-568-B
48、.3. 1010GBASE-E channels are specified to have a minimum of 5 dB and maximum of 11 dB channel insertion loss. 11For 50/125 m multimode fiber, IEEE specifies 240 m (787 ft) for fiber with 400/400 MHzkm modal bandwidth and 300 m (984 ft) for fiber with 500/500 MHzkm modal bandwidth. 12The maximum chan
49、nel attenuation is allowed to be up to 0.5 dB higher than the value shown when including loss from mode conditioning patch cords. I consent to CSA collecting and using the above information to facilitate the collection of my suggestions and comments. Visit CSAs policy on privacy at www.csagroup.org/legal to find out how we protect your personal information.Jaccepte que la CSA conserve et utilise les renseignements ci-dessus afin de faciliter la rceptionde mes suggestions et commentaires.Consultez la