1、PUBLISHED DOCUMENTPD CLC/TR 50455:2008List of interpretations on the EN 60730 series “Automatic electrical controls for household and similar use” ICS 97.120g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55
2、g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58PD CLC/TR 50455:2008This Published Document was published under the authority of the Standards Policy and Strategy Committee on 31 July 2008 BSI 2008ISBN 978 0 580 57067 4National forewordThis Published Document is the UK implementation of CLC
3、/TR 50455:2008. It supersedes PD R072-001:2001 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee CPL/72, Electrical control devices for household equipment and appliances.A list of organizations represented on this committee can be obtained on request to
4、 its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Amendments/corrigenda issued since publicationDate CommentsTECHNICAL REPORT CLC/TR 50455 RAPPORT TECHNIQUE TECHNISCHER BERICHT May 2008 CENELEC Eu
5、ropean Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide
6、for CENELEC members. Ref. No. CLC/TR 50455:2008 E ICS 97.120 Supersedes R072-001:2000English version List of interpretations on the EN 60730 series “Automatic electrical controls for household and similar use“ Liste des interprtations la srie EN 60730 “Dispositifs de commande lectrique automatiques
7、usage domestique et analogue“ Interpretationen zur Normenreihe EN 60730 “Automatische elektrische Regel- und Steuergerte fr den Hausgebrauch und hnliche Anwendungen“ This Technical Report was approved by CENELEC on 2008-03-14. CENELEC members are the national electrotechnical committees of Austria,
8、Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Forewo
9、rd This Technical Report was prepared by the Technical Committee CENELEC TC 72, Automatic controls for household use. Following BT decision D129/C062, the text of the draft was submitted to vote in accordance with the Internal Regulations, Part 2, Subclause 11.4.3.3 (simple majority) and was approve
10、d by CENELEC as CLC/TR 50455 on 2008-03-14. This Technical Report is a revision of R072-001:2000, List of interpretations on the EN 60730 series “Automatic electrical controls for household and similar use“, which was based on document CLC/TC72/SEC0072L/INF. Following comments from DK during the vot
11、ing procedure this Technical Report has been updated to include CLC/TC72/SEC0072M/INF issued in January 2008. Interpretations have been grouped according to different standards. For each standard, the grouping follows the order of the clauses and subclauses. Each interpretation is identified by: - t
12、he place and date of the meeting; - the document number of the minutes and agenda item; - the number of the reference document if applicable. This Technical Report will be updated annually, if necessary. Once an interpretation is superseded by inclusion of suitable wording in the relevant standard i
13、n the EN 60730 series, the interpretation will be withdrawn from this document. _ CLC/TR 50455:2008 2 Contents EN 60730-1:1991 Automatic electrical controls for household and similar use Part 1: General requirements (IEC 60730-1:1986, mod.) EN 60730-1:1995 Part 1: General requirements (IEC 60730-1:1
14、993, mod.) EN 60730-1:2000 Part 1: General requirements (IEC 60730-1:1999, mod.) EN 60730-2-2:1991 Part 2: Particular requirements for thermal motor protectors (IEC 60730-2-2:1990, mod.) EN 60730-2-3:1992 Part 2-3: Particular requirements for thermal protectors for ballasts for tubular fluorescent l
15、amps (IEC 60730-2-3:1990, mod.) EN 60730-2-4:1993 Part 2-4: Particular requirements for thermal motor protectors for motor-compressors of hermetic and semi-hermetic type (IEC 60730-2-4:1990, mod.) EN 60730-2-8:1995 Part 2: Particular requirements for electrically operated water valves, including mec
16、hanical requirements (IEC 60730-2-8:1992, mod.) EN 60730-2-9:2002 Part 2-9: Particular requirements for temperature sensing controls (IEC 60730-2-9:2000, mod.) EN 60730-2-10:1995 Part 2-10: Particular requirements for motor starting relays (IEC 60730-2-10:1991, mod.) EN 60730-2-12:2006 Part 2-12: Pa
17、rticular requirements for electrically operated door locks (IEC 60730-2-12:2005, mod.) EN 60730-2-14:1997 Part 2-14: Particular requirements for electric actuators (IEC 60730-2-14:1995, mod.) CLC/TR 50455:2008 3 01/01/11/21 EN 60730-1:1995 Automatic electrical controls for household and similar use
18、Part 1: General requirements Table 10.1.4 Brussels, November 1996, CLC/TC 72(SEC)76, item 21 The interpretation of the upper limits of the cross sectional areas of fixed wiring conductors for current carried by terminal A “over 10 up to and including 16” and “over 16 up to and including 25” in Table
19、 10.1.4 is as follows: Current carried by terminal A Nominal cross-sectional area mm2 Flexible cord conductors Fixed wiring conductors over 10 up to and including 16 1,5 to 4 over 16 up to and including 25 2,5 to 6 02/01/12/16 EN 60730-1:1991 Automatic electrical controls for household and similar u
20、se Part 1: General requirements Table 20.1, Note 6 Ischia, September 1997, CLC/TC 72(SEC)93A, item 16.2 CLC/TC 72(GB)52 In EN 60730-1:1995 the voltage “step” limits have changed since EN 60730-1:1991. In the 1991 edition the voltage limit specified in Table 20.1, Note 6, was 380 V maximum whereas th
21、e 1995 edition allows up to 400 V. As many of the Part 2s in the EN 60730 series still refer to the 1991 edition of EN 60730-1, for these Part 2s, Note 6 of Table 20.1 of EN 60730-1:1995, allowing up to 400 V, is used as an interpretation. 03/01/12/16 EN 60730-1:1995 Automatic electrical controls fo
22、r household and similar use Part 1: General requirements Subclause 10.2.4 Ischia, September 1997, CLC/TC 72(SEC)93A, item 16.4 CLC/TC 72(SEC)78 TC 72(SEC)90 Whilst work on flat push-on connectors is being carried out in IEC/TC 72, the dimensional requirements of EN 61210 are acceptable as an alterna
23、tive in this clause. CLC/TR 50455:2008 4 04/01/14/09 EN 60730-1:1995/A17:2000 Automatic electrical controls for household and similar use Part 1: General requirements Table H.23 For the purposes of using Table H.23, “load terminals and AC mains” are understood to be “load terminals which are in conn
24、ection with AC mains”. 05/01/15/09.1 EN 60730-1:2000 Automatic electrical controls for household and similar use Part 1: General requirements Subclauses 11.3.6 to 11.3.8 Copenhagen, September 2000, CLC/TC 72(SEC)123,item 9.1 For the purposes of trying to obtain an intermediate position of an actuati
25、ng member, between any indexed, marked, or intended rest positions, the actuating member should be actuated as in normal use. For example, putting a “rocker switch” type of actuating member into an intermediate position with two fingers, is not considered as being actuated in normal use. 06/01/16/16
26、.2 EN 60730-1:1995 and EN 60730-1:2000 Automatic electrical controls for household and similar use Part 1: General requirements Clause 17 Brussels, November 2001, CLC/TC72(Sec)141, item 16.2 Table 17.2-1 Add ”601)”in the column “Type of circuit“ to the cell for “Declared specific load” and the follo
27、wing note to the table. 601) For the tests of tungsten filament lamp load the load and test of EN 60669-1 subclause 18.2 and for fluorescent lamp load the load of EN 60669-1, subclause 19.2 shall be used, under the conditions as specified in 17.16 in the relevant Part 2. 17.3.1 Replace the last sent
28、ence of the third dashed paragraph by: If Tminis less than 0 C, the following additional tests shall be carried out with the switch head maintained between Tminand (Tmin 5) C. Type 1 controls Clauses 16 and 17 Type 2 controls Clauses 15, 16 and 17 Three x additional samples required. CLC/TR 50455:20
29、08 5 07/01/17/16.3.1 EN 60730-1:1995 and EN 60730-1:2000 Automatic electrical controls for household and similar use Part 1: General requirements Subclause 11.10.2 Edinburgh, November 2001, CLC/TC 72(SEC)154, item 16.3.1 Add: If in-line cord controls provided with a plug and a socket outlet, where t
30、he plug can be connected to a socket outlet rated for a higher load current than the control, the control shall be provided with an incorporated fuse or a protective device to limit the current to the controls rating. The testing of the protective function is done in the sequence of tests according
31、to 27.5. The plug and socket outlet part of the control shall comply with the appropriate standard for the plug and socket system. The control part shall comply with this standard. Clause 27 Add: 27.5 See annex H. Annex H Add: H27.5 The following overload tests are carried out on in-line cord contro
32、ls as indicated in 11.10.2 and provided with a plug and socket outlet: - Controls as specified without protective devices and without incorporated fuses are loaded for 1 h with the conventional tripping current for the fuse which in the installation will protect the control. - Controls protected by
33、protective devices (including fuses) are loaded in such a way that the current through the control is 0,95 times the current with which the protective device releases after 1 h. The temperature rise is measured after a steady state has been reached or after 4 h, whichever is the shorter time. - Cont
34、rols protected by incorporated fuses complying with EN 60127 shall have those fuses replaced by links of negligible impedance and shall be loaded in such a manner that the current through the links shall be 2,1 times the rated current of the fuse. The temperature rise is measured after the electroni
35、c switch has been loaded for 30 mm. - Controls protected both by incorporated fuses and by protective devices are loaded either as described above with incorporated fuses or with another protective device, choosing the test requiring the lower load. - Controls protected by protective devices which w
36、ill short-circuit only in case of overload shall be tested both as controls with protective devices and as controls without protective devices. The temperatures measured shall not surpass those indicated in table 14. CLC/TR 50455:2008 6 08/01/19/11.1 EN 60730-1:2000 Automatic electrical controls for
37、 household and similar use Part 1: General requirements Annex N Paris, November 2004, TC72/Sec0189/RM, item 11.1 Conductive pollution described in Clause N.1 note 2 should be considered as pollution degree 2 unless the area is affected by other pollution, in which case the pollution degree correspon
38、ding to the other pollution applies. If this interpretation is not accepted, then controls which previously passed according to the requirements for operational insulation of the previous edition may not meet the requirements for pollution degree 3 of this edition. 09/01/19/12 EN 60730-1:2000 Automa
39、tic electrical controls for household and similar use Part 1: General requirements Subclause 2.10.1 Paris, November 2004, TC72/Sec0189/RM, item 12 Add a second line to read: A cable or cord to an external SELV device (sensor) is not considered to be an external conductor as defined in 2.10.1. It is
40、not necessary for such cables or cords, whether detachable or not, to comply with 11.8.1. 10/01/21/07 EN 60730-1:2000 Automatic electrical controls for household and similar use Part 1: General requirements Subclause 9.2 Paris, November 2006, TC 72/Sec0225/RM, item 7 Delete the note 01/2-2/11/17.4 E
41、N 60730-2-2:1991 Automatic electrical controls for household and similar use Part 2: Particular requirements for thermal motor protectors Subclause 20.101 Brussels, November 1996, CLC/TC 72(SEC)76, item 17.4 The interpretation of the exclusion is that it also applies to terminals and terminations an
42、d therefore it is to be interpreted that added to the exclusion of 20.101 are the words “This exemption includes terminals and terminations”. CLC/TR 50455:2008 7 01/2-3/11/17.4 EN 60730-2-3:1992 Automatic electrical controls for household and similar use Part 2-3: Particular requirements for thermal
43、 protectors for ballasts for tubular fluorescent lamps Subclause 20.2.101 Brussels, November 1996, CLC/TC 72(SEC)76, item 17.4 The interpretation of the exclusion is that it also applies to terminals and terminations and therefore it is to be interpreted that added to the exclusion of 20.2.101 are t
44、he words “This exemption includes terminals and terminations”. 01/2-4/11/17.4 EN 60730-2-4:1993 Automatic electrical controls for household and similar use Part 2-4: Particular requirements for thermal motor protectors for motor-compressors of hermetic and semi-hermetic type Subclause 20.101 Brussel
45、s, November 1996, CLC/TC 72(SEC)76, item 17.4 The interpretation of the exclusion is that it also applies to terminals and terminations and therefore it is to be interpreted that added to the exclusion of 20.101 are the words “This exemption includes terminals and terminations”. 01/2-8/11/17.1 EN 60
46、730-2-8:1995 Automatic electrical controls for household and similar use Part 2: Particular requirements for electrically operated water valves, including mechanical requirements Appendix BB Brussels, November 1996, CLC/TC 72(SEC)76, item 17.1 The interpretation of item 9 of the arrangement for the
47、measurement of transient pressures caused by water valves is as follows: Steel pipe or copper pipe with lining having a wall thickness of 1,0 mm to 2,0 mm and a length of approximately 9 m and as well as an internal diameter which is chosen to be the largest standard size which limits the velocity o
48、f the water flow to not exceed 2m/s with the sample valve fully open and a static pressure of 0,6 MPa and with the nominal internal diameter of the pipe not larger than that of the valve inlet. Item 1 of the measurement procedure needs to refer to the above item 9. CLC/TR 50455:2008 8 02/2-8/16/10.5
49、 EN 60730-2-8:1995 Automatic electrical controls for household and similar use Part 2: Particular requirements for electrically operated water valves, including mechanical requirements Appendix CC Brussels, November 2001, CLC/TC 72(Sec)141, item 10.5 The second test period is conducted at the same temperature as the first test period. 01/2-9/18/11.1 EN 60730-2-9:2002 Automatic electrical controls for household and similar use Part 2-9: Particular requirements for temperatur