1、June 2013 Translation by DIN-Sprachendienst.English price group 10No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 9
2、1.100.60!%1“2021491www.din.deDDIN EN 12087Thermal insulating products for building applications Determination of long term water absorption by immersion;English version EN 12087:2013,English translation of DIN EN 12087:2013-06Wrmedmmstoffe fr das Bauwesen Bestimmung der Wasseraufnahme bei langzeitig
3、em Eintauchen;Englische Fassung EN 12087:2013,Englische bersetzung von DIN EN 12087:2013-06Produits isolants thermiques destins aux applications du btiment Dtermination de labsorption deau long terme par immersion;Version anglaise EN 12087:2013,Traduction anglaise de DIN EN 12087:2013-06SupersedesDI
4、N EN 12087:2007-06www.beuth.deDocument comprises 1 pagesIn case of doubt, the German-language original shall be considered authoritative.5 05.13DIN EN 12087:2013-06 2 A comma is used as the decimal marker. National foreword This document (EN 12087:2013) has been prepared by Technical Committee CEN/T
5、C 88 Thermal insulating materials and products“ (Secretariat: DIN, Germany) The responsible German body involved in its preparation was the Normenausschuss Bauwesen (Building and Civil Engineering Standards Committee), Working Committee NA 005-56-60 AA Wrmedmmstoffe. The DIN Standard corresponding t
6、o the International Standard referred to in Clause 2 of this standard is as follows: ISO 5725-2 DIN ISO 5725-2 Amendments This standard differs from DIN EN 12087:2007-06 as follows: a) the standard has been editorially revised. Previous editions DIN 18165: 1957-08, 1963-03 DIN EN 18165-1: 1975-01, 1
7、987-03, 1991-07 DIN EN 12087: 1997-08, 2007-06 National Annex NA (informative) Bibliography DIN ISO 5725-2, Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method EUROPEAN S
8、TANDARD NORME EUROPENNE EUROPISCHE NORM EN 12087 March 2013 ICS 91.100.60 Supersedes EN 12087:1997English Version Thermal insulating products for building applications - Determination of long term water absorption by immersion Produits isolants thermiques destins aux applications du btiment - Dtermi
9、nation de labsorption deau long terme par immersion Wrmedmmstoffe fr das Bauwesen - Bestimmung der Wasseraufnahme bei langzeitigem Eintauchen This European Standard was approved by CEN on 15 December 2012. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the
10、conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard e
11、xists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national
12、standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia
13、, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2013 CEN All rights of exploitation in any form and by any means reserved world
14、wide for CEN national Members. Ref. No. EN 12087:2013: EEN 12087:2013 (E) 2 Contents Page Foreword 3 1 Scope 5 2 Normative references 5 3 Terms and definitions .5 4 Principle 5 4.1 Partial immersion (method 1) .5 4.2 Total immersion (method 2) 5 5 Apparatus .5 6 Test specimens 8 6.1 Dimensions of te
15、st specimens .8 6.2 Number of test specimens 8 6.3 Preparation of test specimens .8 6.4 Conditioning of test specimens .8 7 Procedure .8 7.1 Test conditions 8 7.2 Test procedure .9 7.2.1 General 9 7.2.2 Long term water absorption by partial immersion (method 1) .9 7.2.3 Long term water absorption by
16、 total immersion (method 2) . 10 8 Calculation and expression of results 11 8.1 General . 11 8.2 Long-term water absorption by partial immersion 11 8.3 Long-term water absorption by total immersion . 12 9 Accuracy of measurement . 13 10 Test report . 13 DIN EN 12087:2013-06 EN 12087:2013 (E) 3 Forew
17、ord This document (EN 12087:2013) has been prepared by Technical Committee CEN/TC 88 “Thermal insulating materials and products”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorse
18、ment, at the latest by September 2013, and conflicting national standards shall be withdrawn at the latest by September 2013. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for ide
19、ntifying any or all such patent rights. This document supersedes EN 12087:1997. The revision of this standard contains no major changes, only minor corrections and clarifications of an editorial nature. This European Standard is one of a series of standards which specify test methods for determining
20、 dimensions and properties of thermal insulating materials and products. It supports a series of product standards for thermal insulating materials and products which derive from the Council Directive of 21 December 1988 on the approximation of laws, regulations and administrative provisions of the
21、Member States relating to construction products (Directive 89/106/EEC) through the consideration of the essential requirements. This European Standard has been drafted for applications in buildings but may also be used in other areas where it is relevant. This European test standard is one of the fo
22、llowing group of inter-related standards on test methods for determining dimensions and properties of thermal insulation materials and products, all of which fall within the scope of CEN/TC 88: EN 822, Thermal insulating products for building applications Determination of length and width EN 823, Th
23、ermal insulating products for building applications Determination of thickness EN 824, Thermal insulating products for building applications Determination of squareness EN 825, Thermal insulating products for building applications Determination of flatness EN 826, Thermal insulating products for bui
24、lding applications Determination of compression behaviour EN 1602, Thermal insulating products for building applications Determination of the apparent density EN 1603, Thermal insulating products for building applications Determination of dimensional stability under constant normal laboratory condit
25、ions (23 C/50 % relative humidity) EN 1604, Thermal insulating products for building applications Determination of dimensional stability under specified temperature and humidity conditions EN 1605, Thermal insulating products for building applications Determination of deformation under specified com
26、pressive load and temperature conditions EN 1606, Thermal insulating products for building applications Determination of compressive creep DIN EN 12087:2013-06 EN 12087:2013 (E) 4 EN 1607, Thermal insulating products for building applications Determination of tensile strength perpendicular to faces
27、EN 1608, Thermal insulating products for building applications Determination of tensile strength parallel to faces EN 1609, Thermal insulating products for building applications Determination of short-term water absorption by partial immersion EN 12085, Thermal insulating products for building appli
28、cations Determination of linear dimensions of test specimens EN 12086, Thermal insulating products for building applications Determination of water vapour transmission properties EN 12087, Thermal insulating products for building applications Determination of long-term water absorption by immersion
29、EN 12088, Thermal insulating products for building applications Determination of long-term water absorption by diffusion EN 12089, Thermal insulating products for building applications Determination of bending behaviour EN 12090, Thermal insulating products for building applications Determination of
30、 shear behaviour EN 12091, Thermal insulating products for building applications Determination of freeze-thaw resistance EN 12429, Thermal insulating products for building applications Conditioning to moisture equilibrium under specified temperature and humidity conditions EN 12430, Thermal insulati
31、ng products for building applications Determination of behaviour under point load EN 12431, Thermal insulating products for building applications Determination of thickness for floating floor insulating products EN 13793, Thermal insulating products for building applications Determination of behavio
32、ur under cyclic loading EN 13820, Thermal insulating materials for building applications Determination of organic content According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium
33、, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerla
34、nd, Turkey and the United Kingdom. DIN EN 12087:2013-06 EN 12087:2013 (E) 5 1 Scope This European Standard specifies the equipment and procedures for determining the long-term water absorption of test specimens. It is applicable to thermal insulating products. This European Standard specifies two op
35、tions: Method 1 - partial immersion Method 2 - total immersion The long-term water absorption by partial immersion is intended to simulate the water absorption caused by long term water exposure. The long-term water absorption by total immersion is not directly related to the conditions on site, but
36、 has been recognised as a relevant condition of test for some products in some applications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applie
37、s. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 12085, Thermal insulating products for building applications Determination of linear dimensions of test specimens ISO 5725-2, Accuracy (trueness and precision) of measurement methods and r
38、esults Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method 3 Terms and definitions This European Standard contains no terms and definitions. 4 Principle 4.1 Partial immersion (method 1) The long-term water absorption by partial immersion i
39、s determined by measuring the change in mass of a test specimen, the lower part of which is in contact with water for a period of 28 days. The excess water adhering to the surface, not absorbed by the test specimen, is removed by drainage in method 1A or taken into account by deduction of the initia
40、l water uptake in method 1B. 4.2 Total immersion (method 2) The long term water absorption by total immersion is determined by measuring the change in mass of the test specimen, totally immersed in water, over a period of 28 days. The excess water adhering to the surface, not absorbed by the test sp
41、ecimen, is removed by drainage in method 2A or taken into account by deduction of the initial water uptake in method 2B. 5 Apparatus 5.1 Balance, which allows the determination of the mass of a test specimen to 0,1 g. 5.2 Water tank, with a device for keeping the water level constant to within 2 mm,
42、 and a device to keep the test specimen in the required position. DIN EN 12087:2013-06 EN 12087:2013 (E) 6 Examples of test devices are given in the Figures 1, 2 and 3. The device to keep the test specimen in position shall not cover more than 15 % of the cross section area of the test specimen, whi
43、ch is exposed to water. The device shall be such that the original form of the test specimen is maintained. Key 1 watertank 2 load to keep the test specimen in position 3 test specimen Figure 1 Example of partial immersion test device (method 1A and 1B) Key 1 watertank 2 load to keep the test specim
44、en in position 3 test specimen Figure 2 Example of equipment for the determination of water absorption by total immersion (method 2A and 2B) DIN EN 12087:2013-06 EN 12087:2013 (E) 7 Key 1 balance 2 weighing table 3 linkage 4 water container 5 water 6 mesh cage made of stainless material with fixing
45、rods or a sinker large enough in mass to compensate for the upthrust of the test specimen 7 test specimen Figure 3 Example of equipment for determination of water absorption by total immersion (method 2C) 5.3 Tap water, adjusted to a temperature of (23 5) C. In case of dispute, deionised water shall
46、 be used. 5.4 Equipment for drainage The principle for methods 1A and 2A is illustrated in Figures 4a and 4b. DIN EN 12087:2013-06 EN 12087:2013 (E) 8 Key 1 stainless steel mesh 2 test specimen 3 perforated stainless steel Figure 4 Examples of equipment for drainage 6 Test specimens 6.1 Dimensions o
47、f test specimens The thickness of the test specimens shall be the original product thickness. The test specimens shall be squares with squarely cut edges having sides of (200 1) mm. 6.2 Number of test specimens The number of test specimens shall be as specified in the relevant product standard or an
48、y other European Technical Specification. In the absence of such a specification, at least four test specimens shall be used. 6.3 Preparation of test specimens The test specimens shall be cut so that they do not include original product edges. Test specimens shall be prepared by methods that do not
49、substantially change the original structure of the product. Any skins, facings and/or coatings shall be retained. Special methods of preparation, when needed, are given in the relevant product standard or any other European Technical Specification. 6.4 Conditioning of test specimens The test specimens shall be stored for at least 6 h at (23 5) C. In case of dispute, they shall be stored at (23 2) C and (50 5) % relative