1、September 2015 Translation by DIN-Sprachendienst.English price group 16No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).
2、ICS 93.080.30!%E7“2349220www.din.deDDIN EN 124-2Gully tops and manhole tops for vehicular and pedestrian areas Part 2: Gully tops and manhole tops made of cast iron;English version EN 124-2:2015,English translation of DIN EN 124-2:2015-09Aufstze und Abdeckungen fr Verkehrsflchen Teil 2: Aufstze und
3、Abdeckungen aus Gusseisen;Englische Fassung EN 124-2:2015,Englische bersetzung von DIN EN 124-2:2015-09Dispositifs de couronnement et de fermeture pour les zones de circulation utilises par lespitons et les vhicules Partie 2: Dispositifs de couronnement et de fermeture en fonte;Version anglaise EN 1
4、24-2:2015,Traduction anglaise de DIN EN 124-2:2015-09Together with DIN EN 124-1:2015-09, DIN EN 124-3:2015-09, DIN EN 124-4:2015-09, DIN EN 124-5:2015-09and DIN EN 124-6:2015-09 supersedes DIN EN 124:1994-08See start of applicationSupersedes: see belowwww.beuth.deIn case of doubt, the German-languag
5、e original shall be considered authoritative.Document comprises 36 pages 08.15 DIN EN 124-2:2015-09 2 A comma is used as the decimal marker. Start of application The start of application of this standard is 2015-09-01. It should be noted that, in Germany, CE conformity marking of construction produc
6、ts will be permitted once this standard has been listed in the Official Journal of the European Union and/or the Bundesanzeiger (German Federal Gazette) and from the date given therein. For further information, users of this standard should refer to the websites of the European Commission or of the
7、relevant building authority. The standard which this document replaces, DIN EN 124:1994-08, may be used in parallel with this standard during a specified transition period where such has been laid down in the Official Journal of the European Union and/or the Bundesanzeiger (German Federal Gazette).
8、National foreword This document (EN 124-2:2015) has been prepared by Technical Committee CEN/TC 165 “Waste water engineering” (Secretariat: DIN, Germany). The preliminary work was done by Working Group WG 4 “Manhole tops, gully tops, drainage channels and other ancillary components for use outside b
9、uildings”. The responsible German body involved in its preparation was the DIN-Normenausschuss Wasserwesen (DIN Standards Committee Water Practice), Working Committee NA 119-05-01 AA Entwsserungsgegenstnde. When placing manhole tops and gully tops on the German market, the performance of the followi
10、ng essential characteristics shall be stated: reaction to fire; frame bearing area; load-bearing capacity; permanent set; securing of covers/gratings within the frame; skid resistance; durability of load-bearing capacity against mechanical failure, securing against unintended lifting, skid resistanc
11、e against loss of grip. Methods used in Germany for securing the cover or grating within the frame are given in the national standard DIN 1229. DIN EN 124-2:2015-09 3 Amendments This standard differs from DIN EN 124:1994-08 as follows: a) the standard has been split into 6 parts with Part 1 containi
12、ng general design and performance requirements and Parts 2 to 6 performance requirements for manhole tops and gully tops made of specific materials; b) test methods for specific materials have been added. Previous editions DIN 1229: 1939-08, 1941-01, 1953-09, 1956x-08, 1964-09 DIN 1213: 1941-10, 195
13、2-08, 1964-09 DIN 1213-1: 1973-05 DIN 1213-2: 1973-05 DIN 1229-1: 1973-05 DIN 1229-2: 1973-05 DIN EN 124: 1986-06, 1994-08 DIN EN 124-2:2015-09 4 This page is intentionally blank EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 124-2 June 2015 ICS 93.080.30 Supersedes EN 124:1994English Version
14、Gully tops and manhole tops for vehicular and pedestrian areas -Part 2: Gully tops and manhole tops made of cast iron Dispositifs de couronnement et de fermeture pour les zones de circulation utilises par les pitons et les vhicules - Partie 2: Dispositifs de couronnement et de fermeture en fonte Auf
15、stze und Abdeckungen fr Verkehrsflchen - Teil 2: Aufstze und Abdeckungen aus Gusseisen This European Standard was approved by CEN on 12 March 2015. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of
16、 a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German)
17、. A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, C
18、yprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
19、Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 124
20、-2:2015 EEN 124-2:2015 (E) 2 Contents Page Foreword 3 1 Scope 4 2 Normative references 4 3 Terms and definitions .5 4 Materials .5 4.1 General 5 4.2 Coating materials .5 4.3 Cover fillings 5 5 Requirements .6 5.1 Design and performance requirements .6 5.2 Covers with fillings 7 5.3 Material-specific
21、 characteristics for gully tops and manhole tops made of cast iron .7 5.3.1 Reaction to fire .7 5.3.2 Durability 7 5.3.3 Dangerous substances .8 6 Testing 8 7 Assessment and verification of constancy of performance - AVCP 8 7.1 General 8 7.2 Type testing 9 7.2.1 General 9 7.2.2 Test samples, testing
22、 and compliance criteria .9 7.2.3 Test reports . 11 7.2.4 Shared other party results . 11 7.3 Factory production control (FPC) . 12 7.3.1 General . 12 7.3.2 Requirements 12 7.3.3 Product specific requirements 17 7.3.4 Initial inspection of factory and of FPC 18 7.3.5 Continuous surveillance of FPC .
23、 18 7.3.6 Procedure for modifications 18 8 Designation . 18 9 Marking 20 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation . 22 ZA.1 Scope and relevant characteristics 22 ZA.2 Procedures for AVCP of gully tops and manhole to
24、ps made of cast iron 24 ZA.3 CE marking and labelling . 28 Bibliography . 32 DIN EN 124-2:2015-09 EN 124-2:2015 (E) 3 Foreword This document (EN 124-2:2015) has been prepared by Technical Committee CEN/TC 165 “Wastewater engineering”, the secretariat of which is held by DIN. This European Standard s
25、hall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by December 2015 and conflicting national standards shall be withdrawn at the latest by March 2017. Attention is drawn to the possibility that some of the elements of this doc
26、ument may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. Together with EN 124-1:2015, EN 124-3:2015, EN 124-4:2015, EN 124-5:2015 and EN 124-6:2015, this document supersedes EN 124:1994. This document has been prepared
27、 under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of the Regulation (EU) No. 305/2011. For relationship with EU Regulation(s), see informative Annex ZA, which is an integral part of this document. EN 124, Gully tops
28、and manhole tops for vehicular and pedestrian areas, consists of the following parts: Part 1: Definitions, classification, general principles of design, performance requirements and test methods; Part 2: Gully tops and manhole tops made of cast iron; Part 3: Gully tops and manhole tops made of steel
29、 or aluminium alloys; Part 4: Gully tops and manhole tops made of steel reinforced concrete; Part 5: Gully tops and manhole tops made of composite materials; Part 6: Gully tops and manhole tops made of polypropylene (PP), polyethylene (PE) or unplasticized poly(vinyl chloride) (PVC-U). According to
30、the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece,
31、 Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. DIN EN 124-2:2015-09 EN 124-2:2015 (E) 4 1 Scope This European Standard is applicable to gully tops
32、and manhole tops made of flake graphite cast iron and/or spheroidal graphite cast iron whether in combination with concrete or not, with a clear opening up to and including 1 000 mm for covering gullies, manholes and inspection chambers for installation within areas subjected to pedestrian and/or ve
33、hicular traffic. It is applicable to manhole tops and gully tops for use in areas which can only be used by pedestrians and pedal cyclists (at least class A 15), pedestrian areas and comparable areas, car parks or car parking decks (at least class B 125), the area of kerbside channels of roads which
34、, when measured from the kerb edge, extends a maximum of 0,5 m into the carriageway and a maximum of 0,2 m into the pedestrian area (at least class C 250), carriageways of roads (including pedestrian streets), hard shoulders and parking areas, for all types of road vehicles (at least class D 400), a
35、reas imposing high wheel loads, e.g. docks, aircraft pavements (at least class E 600), areas imposing particularly high wheel loads, e.g. aircraft pavements (class F 900). This European Standard is not applicable in isolation but only in combination with EN 124-1 and gives guidance for combinations
36、of covers/grating made of cast iron with frames according to EN 124-3, EN 124-4, EN 124-5 or EN 124-6. This European Standard is not applicable to: cover fillings installed on site, e.g. concrete, paving blocks, etc.; concave gratings for class D 400 installed in carriageways of roads or hard should
37、ers and concave gratings for classes F 900 and E 600; gratings/covers as part of prefabricated drainage channels according to EN 1433; floor and roof gullies in buildings which are specified in EN 1253 (all parts); and surface boxes. 2 Normative references The following documents, in whole or in par
38、t, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 124-1:2015, Gully tops and manhole tops for veh
39、icular and pedestrian areas Part 1: Definitions, classification, general principles of design, performance requirements and test methods EN 124-3:2015, Gully tops and manhole tops for vehicular and pedestrian areas Part 3: Gully tops and manhole tops made of steel or aluminium alloys EN 124-4:2015,
40、Gully tops and manhole tops for vehicular and pedestrian areas Part 4: Gully tops and manhole tops made of steel reinforced concrete DIN EN 124-2:2015-09 EN 124-2:2015(E)5 EN 124-5:2015, Gully tops and manhole tops for vehicular and pedestrian areas Part 5: Gully tops and manhole tops made of compos
41、ite materials EN 124-6:2015, Gully tops and manhole tops for vehicular and pedestrian areas Part 6: Gully tops and manhole tops made of polypropylene (PP), polyethylene (PE) or unplasticized poly(vinyl chloride) (PVC-U) EN 206:2013, Concrete Specification, performance, production and conformity EN 1
42、561, Founding Grey cast irons EN 1563, Founding Spheroidal graphite cast irons 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 124-1:2015 apply. 4 Materials 4.1 General Manhole tops and gully tops according to this European Standard shall be made from
43、 the materials listed below. a) flake graphite cast iron according to EN 1561, b) spheroidal graphite cast iron according to EN 1563, c) one of the materials a) and b) combined with concrete with a minimum compressive strength class of C35/45. Any element made of the materials specified in 4.1 a) to
44、 c) can be used in combination with elements of materials specified in EN 124-3, EN 124-4, EN 124-5 or EN 124-6. In such cases the manhole tops or gully tops shall comply with the relevant design and performance and testing requirements as listed in Table 1. In addition elements shall comply with th
45、e requirements for the material related to EN 124-3, EN 124-4, EN 124-5 or EN 124-6, as applicable. Each element shall be marked accordingly. The class to be declared for the combined product shall be restricted to the lower class determined for any constituent element according to the relevant part
46、 of EN 124 series. EXAMPLE Where a cover is made of cast iron, class D 400, and the frame is made of PVC-U, class B 125, the manhole top or gully top is marked with EN 124-2, and the class to be declared for the combined product is the class of the frame according to EN 124-6. 4.2 Coating materials
47、Manhole tops and gully tops made of cast iron can be supplied uncoated or coated. Coating materials shall comply with the environmental and/or toxicological regulations at the place of intended use. NOTE In general, coatings are for aesthetic purposes only and are not regarded as a corrosion protect
48、ion system. The specifier or client may require a more durable coating if appropriate. 4.3 Cover fillings In the case of covers placed on the market in filled condition the filling shall consist of either: a) concrete with a minimum compressive strength class of C35/45 according to EN 206:2013 at least suitable for use in “cyclic wet and dry” conditions, or DIN EN 124-2:2015-09 EN 124-2:2015 (E) 6 b) other material complying with the intended use/place of installation