1、March 2015 Translation by DIN-Sprachendienst.English price group 16No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS
2、91.140.80!%ARH“2304737www.din.deDDIN EN 1253-2Gullies for buildings Part 2: Roof drains and floor gullies without trap;English version EN 1253-2:2015,English translation of DIN EN 1253-2:2015-03Ablufe fr Gebude Teil 2: Dachablufe und Bodenablufe ohne Geruchverschluss;Englische Fassung EN 1253-2:2015
3、,Englische bersetzung von DIN EN 1253-2:2015-03Avaloirs et siphons pour btiments Partie 2: Avaloirs de toiture et avaloirs/siphons de sol sans garde deau;Version anglaise EN 1253-2:2015,Traduction anglaise de DIN EN 1253-2:2015-03Together with DIN EN1253-1:2015-03,supersedesDIN EN 1253-2:2004-03 and
4、DIN EN 1253-1:2003-09www.beuth.deDocument comprises 38 pagesIn case of doubt, the German-language original shall be considered authoritative.02.15DIN EN 1253-2:2015-03 2 A comma is used as the decimal marker. National foreword This document (EN 1253-2:2015) has been prepared by Technical Committee C
5、EN/TC 165 “Waste water engineering” (Secretariat: DIN, Germany). The preliminary work was done by Working Group WG 11 “Gratings, covers and other ancillary components for use inside buildings”. The responsible German body involved in its preparation was the DIN-Normenausschuss Wasserwesen (DIN Stand
6、ards Committee Water Practice), Working Committee NA 119-05-11 AA Ablaufgarnituren, Ablufe, Rckstauverschlsse und Belftungsventile fr die Verwendung innerhalb von Gebuden. Amendments This standard differs from DIN EN 1253-1:2003-09 and DIN EN 1253-2:2004-03 as follows: a) the scope has been reduced
7、to roof outlets and floor gullies without trap including parapet and emergency drains for use in gravity and siphonic drainage systems; b) the description of products has been rendered more precise; c) terms and definitions have been modified; d) the definition of places of installation has been ren
8、dered more precise; e) liquid applied membranes have been considered as connecting components; f) test conditions for flow rate testing for different types of products have been given in more detail; g) loading test concerning test loads, loading speed as well as shape, size and point of impact of t
9、est blocks in dependence on different configuration of gratings have been revised; h) classification of products concerning their temperature cycling behaviour according to number of hot/cold water cycles has been introduced; i) the standard has been editorially revised. Previous editions DIN 19599:
10、 1982-08, 1986-04, 1989-01, 1990-11 DIN EN 1253-1: 1999-06, 2004-03 DIN EN 1253-2: 1999-06, 2004-03 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1253-2 January 2015 ICS 91.140.80 Supersedes EN 1253-1:2003, EN 1253-2:2003English Version Gullies for buildings - Part 2: Roof drains and floor gu
11、llies without trap Avaloirs et siphons pour btiments - Partie 2: Avaloirs de toiture et avaloirs/siphons de sol sans garde deau Ablufe fr Gebude - Teil 2: Dachablufe und Bodenablufe ohne Geruchverschluss This European Standard was approved by CEN on 22 November 2014. CEN members are bound to comply
12、with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Ma
13、nagement Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
14、status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, M
15、alta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015
16、CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1253-2:2015 EEN 1253-2:2015 (E) 2 Contents Page Foreword 3 1 Scope 4 2 Normative references 4 3 Terms and definitions .4 4 Requirements .9 4.1 Design and construction .9 4.2 Places of
17、 installation 10 4.3 Materials 11 4.4 Watertightness 11 4.5 Mechanical strength . 11 4.6 Flow rates 11 4.7 Additional requirements in relation to the installation . 13 5 Test methods . 15 5.1 Dimensions of apertures in gratings 15 5.2 Water tightness for roof drain and floor gully bodies and extensi
18、ons . 15 5.3 Loading test . 15 5.4 Mechanical strength . 19 5.5 Flow rates 20 5.6 Tightness of roof drains and floor gullies for use with sheet floor coverings, membranes or liquid applied membranes . 30 5.7 Behaviour when exposed to hot bitumen or asphalt 31 5.8 Determination of resistance in clima
19、tic influences . 31 5.9 Temperature cycling test . 32 6 Allocation and sequence of tests 32 7 Marking 32 8 Evaluation of conformity 33 Annex A (normative) Sequence of the tests 34 Annex B (informative) A-deviation 35 Bibliography . 36 DIN EN 1253-2:2015-03 EN 1253-2:2015 (E) 3 Foreword This document
20、 (EN 1253-2:2015) has been prepared by Technical Committee CEN/TC 165 “Waste water engineering”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by July 2015
21、and conflicting national standards shall be withdrawn at the latest by July 2015. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This
22、 document, together with EN 1253-1:2015, supersedes EN 1253-1:2003 and EN 1253-2:2003. This is the second part in EN 1253, a series of standards relating to floor gullies, roof drains and access covers for drainage systems inside buildings. The EN 1253 series under the main title Gullies for buildin
23、gs will actually consist of the following parts: Part 1: Trapped floor gullies with a depth of water seal of at least 50 mm; Part 2: Roof drains and floor gullies without trap; Part 3: Evaluation of conformity; Part 4: Access covers; Part 5: Gullies with light liquids closure. Since the latest versi
24、ons of EN 1253-1 and EN 1253-2 the most significant technical changes are the following: a) reduction of scope on roof outlets and floor gullies without trap including parapet and emergency drains for use in gravity and siphonic drainage systems; b) more definitive description of products; c) modifi
25、cation of terms and definitions; d) precision in definition of places of installation; e) consideration of liquid applied membranes as connecting components; f) precision of test conditions for flow rate testing for different types of products; g) revision of loading test concerning test loads, load
26、ing speed as well as shape, size and point of impact of test blocks in dependence on different configuration of gratings; h) introduction of classification of products concerning their temperature cycling behavior according to number of hot/cold water cycles. According to the CEN-CENELEC Internal Re
27、gulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland,
28、 Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. DIN EN 1253-2:2015-03 EN 1253-2:2015 (E) 4 1 Scope This European Standard classifies roof drains and floor gullies without trap
29、 for use inside buildings, gives guidance for places of installation and specifies requirements for the construction, design, performance and marking as well as test methods of factory made roof drains and floor gullies without trap (further: floor gullies) for buildings, irrespective of the materia
30、l for use in drainage systems. Although normally used to convey rainwater and wastewater, these roof drains and floor gullies without trap may convey other wastewater provided there is no risk of damage to components or of injury to health. This European Standard does not apply to trapped floor gull
31、ies with a depth of water seal of at least 50 mm as specified in EN 1253-1. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated re
32、ferences, the latest edition of the referenced document (including any amendments) applies. EN 124, Gully tops and manhole tops for vehicular and pedestrian areas Design requirements, type testing, marking, quality control EN 476, General requirements for components used in drains and sewers EN 1253
33、-3, Gullies for buildings Part 3: Evaluation of conformity 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 roof drain non-trapped discharge fitting for the drainage of surface water from roof, balcony and terrace surfaces via a rainwater conn
34、ecting pipe Note 1 to entry: See Figure 1. Note 2 to entry: A roof drain can include an anti-vortex device. 3.2 parapet drain roof drain for the drainage of flat roofs and roof terraces with a fascia which penetrates the fascia Note 1 to entry: See Figure 2. 3.3 emergency drain roof drain for emerge
35、ncy drainage in the form of a roof, parapet or gutter outlet with or without a rainwater connection pipe DIN EN 1253-2:2015-03 EN 1253-2:2015 (E) 5 Key 1 grating/frame, leaf/gravel trap 2 liquid applied roof waterproofing kit or flexible sheet for waterproofing 3 extension 4 seal 5 connecting flange
36、 6 body 7 outlet Figure 1 Roof drain (example) DIN EN 1253-2:2015-03 EN 1253-2:2015 (E) 6 Key 1 grating 2 body 3 connecting flange 4 liquid applied roof waterproofing kit or flexible sheet for waterproofing 5 outlet (round or rectangular) Figure 2 Parapet drain (example) 3.4 gravity drainage system
37、system where flow is caused by gravity and where the pipe normally operates partially full 3.5 siphonic drainage system system for drainage of rainwater in which the outlets and pipework enable the system to flow completely full under design conditions and make use of the total height available betw
38、een the outlets and the point of change to partially filled flow 3.6 head of water depth h of a water line over the spill edge of the roof drain or floor gully as shown in Figure 3 Key h head of water Figure 3 Head of water 3.7 grating removable component with apertures which permit the discharge of
39、 water DIN EN 1253-2:2015-03 EN 1253-2:2015 (E) 7 3.8 frame support for a grating or cover which is connected to a body either directly or by means of a flexible sheet for waterproofing clamping ring or an extension 3.9 cover removable part of an access cover which covers the opening 3.10 body part
40、of a roof drain or floor gully below or in the floor, ground or roof on which the grating/frame/extension is mounted, and to which the pipework is connected 3.11 extension component used to adjust the height of a grating or cover above a body 3.12 joint connection between the adjacent ends of two co
41、mponents including the means of sealing 3.13 flexible sheet for waterproofing clamping ring component used to clamp a flexible sheet for waterproofing to a body or extension 3.14 connecting flange separate or an integral part of a body or of an extension which receives a flexible sheet for waterproo
42、fing or the liquid applied roof waterproofing kit 3.15 external diameter OD mean external diameter of the pipe barrel at any cross section 3.16 internal diameter ID mean internal diameter of the pipe barrel at any cross section 3.17 liquid applied roof waterproofing kit LARWK particular combination
43、of a defined set of components to be installed in liquid form for roof waterproofing by application and/or incorporation and/or joining of the components in accordance with particular design methods Note 1 to entry: The liquid applied watertight covering is usually a paste-like composite material or
44、 a combination of separate materials that can be poured, spread or sprayed on the subsurface by brush, roller or similar suitable applicator. 3.18 flexible sheet for waterproofing factory made sheet for prevention of passage of water from the plane to another which can be rolled up or folded for eas
45、y transport to the site DIN EN 1253-2:2015-03 EN 1253-2:2015 (E) 8 3.19 untrafficked roof roof consisting of the structural deck and all the layers on it, including waterproofing, insulation and a surface protective layer not designed for foot traffic above that required for maintenance 3.20 pedestr
46、ian access roof roof consisting of the structural deck and all the layers on it, including waterproofing, insulation and a surface protective layer designed for foot traffic and gathering of people greater than that required for maintenance 3.21 green roof roof consisting of the structural deck and
47、all the layers on it, including waterproofing, insulation and a thin layer of growing medium planted with vegetation 3.22 roof garden roof consisting of the structural deck and all the layers on it, including waterproofing, insulation and a substantial layer of growing medium planted with intensive
48、vegetation and possibly paving 3.23 parking deck roof consisting of the structural deck and all the layers on it, including waterproofing, insulation and a surface protective layer designed to withstand and distribute loads produced by the traffic associated with the parking of vehicles 3.24 nominal
49、 size DN numerical indication of size which is a convenient integer approximately equal to the internal diameter (DN/ID) or the external diameter (DN/OD) in millimetres 3.25 floor gully without trap discharge fitting the top of which is a grating or cover capable of installation at ground or floor level intended to receive wastewater through apertures in the grating Note 1 to entry: See Figure 4. Key 1 grating 2 outlet 3 body Figure 4 Floor gully without trap (typical example) DIN EN 1253-2:2015-03 EN 1253-2:2015 (E) 9 3.26 wastewater