1、August 2010 Translation by DIN-Sprachendienst.English price group 13No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS
2、 71.100.80!$j0“1712913www.din.deDDIN EN 13177Chemicals used for treatment of water intended for humanconsumption MethanolEnglish translation of DIN EN 13177:2010-08Produkte zur Aufbereitung von Wasser fr den menschlichen Gebrauch MethanolEnglische bersetzung von DIN EN 13177:2010-08Produits chimique
3、s utiliss pour le traitement de leau destine la consommationhumaine MthanolTraduction anglaise de DIN EN 13177:2010-08SupersedesDIN EN 13177:2002-12www.beuth.deDocument comprises pagesIn case of doubt, the German-language original shall be considered authoritative.08.10 24DIN EN 13177:2010-08 A comm
4、a is used as the decimal marker. National foreword This standard has been prepared by Technical Committee CEN/TC 164 “Water supply” (Secretariat: AFNOR, France). The responsible German body involved in its preparation was the Normenausschuss Wasserwesen (Water Practice Standards Committee), Working
5、Committee NA 119-04-02 AA Wasseraufbereitung. Users of this standard are advised of the reservations stated in the Introduction of the European Standard and should note that national regulations exist in Germany dealing with water for human consumption, in particular the Trinkwasserverordnung (Trink
6、wV2001) (German Drinking Water Ordinance). Since methanol is not mentioned in the list of substances for treatment and disinfection of water in accordance with article 11 of the Trinkwasserverordnung 2001, it shall not be used for the treatment of drinking water. Attention is drawn to the possibilit
7、y that some of the elements of this document may be the subject of patent rights. DIN shall not be held responsible for identifying any or all such patent rights. The DIN Standards corresponding to the International Standards referred to in clause 2 of the EN are as follows: EN ISO 3696 DIN ISO 3696
8、 ISO 3856-2 DIN ISO 3856-2 ISO 9174 DIN EN 1233 Amendments This standard differs from DIN EN 13177:2002-12 as follows: a) General purity criteria have been given in more detail. b) A note concerning the classification of dangerous substances has been included. c) Information on the risk and safety l
9、abelling has been updated. d) The bibliography has been updated. Previous editions DIN EN 13177: 2002-12 2 DIN EN 13177:2010-08 National Annex NA (informative) Bibliography DIN ISO 3696, Water for analytical laboratory use Specification and test methods DIN ISO 3856-2, Paints and varnishes Determina
10、tion of “soluble” metal content Determination of antimony content DIN EN 1233, Water quality Determination of chromium Atomic absorption spectrometric methods Verordnung zur Novellierung der Trinkwasserverordnung (German Regulation amending the German Drinking Water Ordinance), as of 21 May 2001, Bu
11、ndesgesetzblatt (German Federal Law Gazette) Part 1, No. 24, pp. 959-9801) 1)Recorded in the DITR database of DIN Software GmbH, obtainable from Beuth Verlag GmbH, 10772 Berlin, Germany. 3 DIN EN 13177:2010-08 4 This page is intentionally blank EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13
12、177 April 2010 ICS 71.100.80 Supersedes EN 13177:2002English Version Chemicals used for treatment of water intended for human consumption - Methanol Produits chimiques utiliss pour le traitement de leau destine la consommation humaine - Mthanol Produkte zur Aufbereitung von Wasser fr den menschliche
13、n Gebrauch - Methanol This European Standard was approved by CEN on 28 February 2010. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists
14、and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the respon
15、sibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hun
16、gary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Cent
17、re: Avenue Marnix 17, B-1000 Brussels 2010 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13177:2010: EEN 13177:2010 (E) 2 Contents Page Introduction .41 Scope 52 Normative references 53 Description .53.1 Identification .53.2 Comm
18、ercial form .63.3 Physical properties 63.4 Chemical properties 74 Purity criteria 74.1 General 74.2 Composition of commercial product .74.3 Impurities and main by-products .84.4 Chemical parameters 85 Test methods 85.1 Sampling .85.2 Analysis 96 Labelling - Transportation - Storage . 156.1 Means of
19、delivery 156.2 Risk and safety labelling according to the EU Directives . 156.3 Transportation regulations and labelling . 166.4 Marking 166.5 Storage . 16Annex A (informative) General information on synthetic methanol . 17A.1 Origin . 17A.2 Use . 17A.3 Toxicological aspects 18Annex B (normative) Ge
20、neral rules relating to safety 19B.1 Rules for safe handling and use . 19B.2 Emergency procedures 19Bibliography . 20DIN EN 13177:2010-08 EN 13177:2010 (E) 3 Foreword This document (EN 13177:2010) has been prepared by Technical Committee CEN/TC 164 “Water supply”, the secretariat of which is held by
21、 AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2010, and conflicting national standards shall be withdrawn at the latest by October 2010. Attention is drawn to the possibility tha
22、t some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 13177:2002. According to the CEN/CENELEC Internal Regulations, the national standards organizations
23、 of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, R
24、omania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Differences between this edition and EN 13177:2002 are editorial to harmonize the text with other standards in this series. DIN EN 13177:2010-08 EN 13177:2010 (E) 4 Introduction In respect of potential adverse effects on
25、the quality of water intended for human consumption, caused by the product covered by this Standard: a) this Standard provides no information as to whether the product may be used without restriction in any of the Member States of the EU or EFTA ; b) it should be noted that, while awaiting the adopt
26、ion of verifiable European criteria, existing national regulations concerning the use and/or the characteristics of this product remain in force. NOTE Conformity with the standard does not confer or imply acceptance or approval of the product in any of the Member States of the EU or EFTA. The use of
27、 the product covered by this European Standard is subject to regulation or control by National Authorities. DIN EN 13177:2010-08 EN 13177:2010 (E) 5 1 Scope This European Standard is applicable to synthetic methanol used for treatment of water intended for human consumption. It describes the charact
28、eristics of synthetic methanol and specifies the requirements and the corresponding test methods for synthetic methanol. Annex A gives information on its use in water treatment. 2 Normative references The following referenced documents are indispensable for the application of this document. For date
29、d references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1483, Water quality Determination of mercury EN 26595, Water quality Determination of total arsenic Silver diethyldithiocarbamate spectrophotomet
30、ric method (ISO 6595:1982) EN ISO 3696, Water for analytical laboratory use Specification and test methods (ISO 3696:1987) ISO 3165, Sampling of chemical products for industrial use Safety in sampling ISO 3856-2, Paints and varnishes Determination of “soluble“ metal content Part 2: Determination of
31、antimony content Flame atomic absorption spectrometric method and Rhodamine B spectrophotometric method ISO 6206, Chemical products for industrial use Sampling Vocabulary ISO 8288, Water quality Determination of cobalt, nickel, copper, zinc, cadmium and lead Flame atomic absorption spectrometric met
32、hods ISO 9174, Water quality Determination of chromium Atomic absorption spectrometric methods ISO 9965, Water quality Determination of selenium Atomic absorption spectrometric method (hydride technique) 3 Description 3.1 Identification 3.1.1 chemical name methanol 3.1.2 synonym or common names meth
33、yl alcohol, carbinol 3.1.3 relative molecular mass 32,04 3.1.4 empirical formula CH4O DIN EN 13177:2010-08 EN 13177:2010 (E) 6 3.1.5 chemical formula CH3OH 3.1.6 CAS Registry Number 1)67-56-1 3.1.7 EINECS reference 2)200-65-96 3.2 Commercial form The product is available as colourless liquid. 3.3 Ph
34、ysical properties 3.3.1 appearance the product is a colourless liquid at 20 C 3.3.2 density the density at 20 C is given in Table 1 (see 3 and 4) Table 1 Density Concentration % mass fraction Density g/ml 90 0,821992 0,816394 0,8103 96 0,804898 0,799099,85 0,7936 100 0,79313.3.3 solubility in water
35、Miscible 3.3.4 vapour pressure 12,7 kPa at 20 C (for pure methanol) 1)Chemical Abstracts Service Registry Number.2)European Inventory of Existing Commercial Chemical Substances.DIN EN 13177:2010-08 EN 13177:2010 (E) 7 3.3.5 boiling point at 100 kPa 3)64,6 C (for pure methanol) 3.3.6 melting point -
36、98 C (for pure methanol) 3.3.7 specific heat 2,53 kJ /kg.K at 25 C (for pure methanol) 3.3.8 viscosity, dynamic 0,594 mPa.s at 20 C (for pure methanol) 3.3.9 citical temperature (for gas) not applicable 3.3.10 critical pressure (for gas) not applicable 3.3.11 physical hardness not applicable 3.4 Che
37、mical properties Methanol is a polar and protic organic solvent. 4 Purity criteria 4.1 General This European Standard specifies the minimum purity requirements for methanol used for the treatment of water intended for human consumption. Limits are given for impurities commonly present in the product
38、. Depending on the raw material and the manufacturing process other impurities may be present and, if so, this shall be notified to the user and when necessary to relevant authorities. NOTE Users of this product should check the national regulations in order to clarify whether it is of appropriate p
39、urity for treatment of water intended for human consumption, taking into account raw water quality, required dosage, contents of other impurities and additives used in the products not stated in the product standard. Limits have been given for impurities and chemicals parameters where these are like
40、ly to be present in significant quantities from the current production process and raw materials. If the production process or raw materials leads to significant quantities of impurities, by-products or additives being present, this shall be notified to the user. 4.2 Composition of commercial produc
41、t The product shall contain a minimum of 99,85 % mass fraction pure synthetic methanol. 3)100 kPa = 1 bar.DIN EN 13177:2010-08 EN 13177:2010 (E) 8 4.3 Impurities and main by-products The propan-2-one content shall be less than 30 mg/kg of 100 % mass fraction methanol. NOTE The product contains trace
42、s of water and ethanol which do not affect its use in water treatment. 4.4 Chemical parameters The product shall conform to the requirements specified in Table 2. Table 2 Chemical parameters Parameter Limit in 100 % mass fraction of methanol mg/kgArsenic (As) max. 0,01 Cadmium (Cd) max. 0,01 Chromiu
43、m (Cr) max. 0,01 Mercury (Hg) max. 0,01 Nickel (Ni) max. 0,01 Lead (Pb) max. 0,01 Antimony (Sb) max. 0,01 Selenium (Se) max. 0,01 NOTE For parametric values in drinking water (see 1). 5 Test methods 5.1 Sampling 5.1.1 General Observe the general recommendations of ISO 3165 and take account of ISO 62
44、06. 5.1.2 Sampling from drums and bottles 5.1.2.1 General 5.1.2.1.1 Mix the contents of the container to be sampled by shaking the container, by rolling it or by rocking it from side to side, taking care not to damage the container or spill any of the liquid. 5.1.2.1.2 If the design of the container
45、 is such (for example, a narrow-necked bottle) that it is impracticable to use a sampling implement, take a sample by pouring after the contents have been thoroughly mixed. Otherwise, proceed as described in 5.1.2.1.3. 5.1.2.1.3 Examine the surface of the liquid. If there are signs of surface contam
46、ination, take samples from the surface as described in 5.1.2.2 ; otherwise, take samples as described in 5.1.2.3. 5.1.2.2 Surface sampling Take a sample using a suitable ladle. Lower the ladle into the liquid until the rim is just below the surface, so that the surface layer runs into it. Withdraw t
47、he ladle just before it fills completely and allow any liquid adhering DIN EN 13177:2010-08 EN 13177:2010 (E) 9 to the ladle to drain off. If necessary, repeat this operation so that, when the other selected containers have been sampled in a similar manner, the total volume of sample required for su
48、bsequent analysis is obtained. 5.1.2.3 Bottom sampling Take a sample using an open sampling tube, or a bottom-valve sampling tube, suited to the size of container and the viscosity of the liquid. When using an open sampling tube, close it at the top and then lower the bottom end to the bottom of the
49、 container. Open the tube and move it rapidly so that the bottom of the tube traverses the bottom of the container before the tube is filled. Close the tube, withdraw it from the container and allow any liquid adhering to the outside of the tube to drain off. When using a bottom-valve sampling tube, close the valve before lowering the tube into the container and then proceed in a similar
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1