1、August 2013 Translation by DIN-Sprachendienst.English price group 9No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS
2、75.140; 91.100.50!%(6“2051990www.din.deDDIN EN 1429Bitumen and bituminous binders Determination of residue on sieving of bituminous emulsions, anddetermination of storage stability by sieving;English version EN 1429:2013,English translation of DIN EN 1429:2013-08Bitumen und bitumenhaltige Bindemitte
3、l Bestimmung des Siebrckstandes von Bitumenemulsionen und Bestimmung derLagerbestndigkeit durch Sieben;Englische Fassung EN 1429:2013,Englische bersetzung von DIN EN 1429:2013-08Bitumes et liants bitumineux Dtermination du rsidu sur tamis des mulsions de bitume et dtermination de la stabilitau stock
4、age par tamisage;Version anglaise EN 1429:2013,Traduction anglaise de DIN EN 1429:2013-08SupersedesDIN EN 1429:2009-07www.beuth.deDocument comprises pagesIn case of doubt, the German-language original shall be considered authoritative.1307.13 DIN EN 1429:2013-08 2 A comma is used as the decimal mark
5、er. National foreword This document (EN 1429:2013) has been prepared by Technical Committee CEN/TC 336 “Bituminous binders” (Secretariat: AFNOR, France). The responsible German bodies involved in its preparation were the Normenausschuss Materialprfung (Materials Testing Standards Committee) and the
6、Normenausschuss Bauwesen (Building and Civil Engineering Standards Committee), Joint Committee NA 062-03-32 GA Bitumen; Prfverfahren und Anforde-rungen fr die Bindemittel. The DIN Standards corresponding to the International Standards referred to in Clause 2 of this standard are as follows: ISO 565
7、DIN ISO 565 Amendments This standard differs from DIN EN 1429:2009-07 as follows: a) the precision requirements for the weighing scale to be used in Subclause 8.2 and Clause 9 are now less stringent; b) the definition of dilution procedures for viscous emulsions (Subclauses 8.2.9 and 8.3.8) has been
8、 made more accurate; c) the procedure for the determination of the storage stability by sieving (Clause 9) has been revised; d) the standard has been editorially revised. Previous editions DIN EN 1429: 1999-12, 2009-07 National Annex NA (informative) Bibliography DIN ISO 565, Test sieves Metal wire
9、cloth, perforated metal plate and electroformed sheet Nominal sizes of openings EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1429 June 2013 ICS 75.140; 91.100.50 Supersedes EN 1429:2009English Version Bitumen and bituminous binders - Determination of residue on sieving of bituminous emulsion
10、s, and determination of storage stability by sieving Bitumes et liants bitumineux - Dtermination du rsidu sur tamis des mulsions de bitume et dtermination de la stabilit au stockage par tamisage Bitumen und bitumenhaltige Bindemittel - Bestimmung des Siebrckstandes von Bitumenemulsionen und Bestimmu
11、ng der Lagerbestndigkeit durch Sieben This European Standard was approved by CEN on 11 April 2013. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-t
12、o-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by transla
13、tion under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland,
14、 Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION C
15、OMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1429:2013: EEN 1429:2013 (E) 2 Contents Page Foreword 3 1 Scope
16、4 2 Normative references 4 3 Terms and definitions .4 4 Principle 4 5 Reagents and materials 4 6 Apparatus .5 7 Sampling .6 8 Procedure for the determination of residue on sieving .6 9 Procedure for the determination of the storage stability by sieving after n days storage period 8 10 Calculation 8
17、11 Expression of results 9 12 Precision 10 13 Test report . 10 Bibliography . 11 DIN EN 1429:2013-08 EN 1429:2013 (E) 3 Foreword This document (EN 1429:2013) has been prepared by Technical Committee CEN/TC 336 “Bituminous binders”, the secretariat of which is held by AFNOR. This European Standard sh
18、all be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by December 2013, and conflicting national standards shall be withdrawn at the latest by December 2013. Attention is drawn to the possibility that some of the elements of this
19、document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 1429:2009. The main technical changes brought to EN 1429 are as follows: Less stringent precision requirements for the weighing sc
20、ale to be used in 8.2 and Clause 9. More accurate definition of dilution procedures for viscous emulsions (8.2.9 and 8.3.8). Revision of procedure for determination of the storage stability by sieving (Clause 9). WARNING The use of this European Standard may involve hazardous materials, operations a
21、nd equipment. This European Standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this European Standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to
22、use. Also, for environmental aspects, it is important to limit the quantities of products, solvents and energy sources to reduce the emissions in air and water and the wastes to the minimum required for a valid test realisation. According to the CEN-CENELEC Internal Regulations, the national standar
23、ds organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxe
24、mbourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. DIN EN 1429:2013-08 EN 1429:2013 (E) 4 1 Scope This European Standard specifies methods utilising sieving for the determination of the quantity of coarse part
25、icles of binder present in bitumen emulsions, and for the determination of storage stability. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited appli
26、es. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 58, Bitumen and bituminous binders Sampling bituminous binders EN 12594, Bitumen and bituminous binders Preparation of test samples EN ISO 3696, Water for analytical laboratory use Specif
27、ication and test methods (ISO 3696) ISO 565, Test sieves Metal wire cloth, perforated metal plate and electroformed sheet Nominal sizes of openings 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 residue on sieving mass fraction in % of parti
28、cles retained on a sieve of a mesh size specified in this European Standard 3.2 storage stability ability of a bituminous emulsion not to form more coarse particles within a period specified under an appropriate emulsion specification Note 1 to entry: Storage stability is a different concept than se
29、ttling tendency as defined and measured by EN 12847. Although both phenomena are often linked, an emulsion may settle without modification of particle size distribution (no coalescence of emulsion droplets). Note 2 to entry: The purpose of the limits fixed by the emulsion specification is to ensure
30、that there cannot be any disturbance of the workability of the bitumen emulsion under practical conditions. 4 Principle A known mass of bituminous emulsion is filtered through either a prepared sieve with a mesh size of 0,500 mm or through two prepared sieves with mesh sizes of 0,500 mm and of 0,160
31、 mm. The amount of binder retained on the sieves is weighed after washing and drying. Storage stability is determined as the amount of binder retained on the sieve with a mesh size of 0,500 mm after a defined storage period (n days). 5 Reagents and materials Use only reagents of recognised analytica
32、l grade and water conforming to grade 3 of EN ISO 3696. DIN EN 1429:2013-08 EN 1429:2013 (E) 5 The aqueous solutions (5.1) and (5.2) may be replaced by aqueous phases of the same ionic structure as the emulsion under test. 5.1 Solution SaAqueous phase solution of nominal 0,01 mol/l of sodium hydroxi
33、de (NaOH) containing a nominal 1 % mass fraction sodium oleate. This solution, or the actual aqueous phase, may be used for the preparation of anionic emulsion samples. 5.2 Solution ScAqueous phase solution of nominal 0,01 mol/l of hydrochloric acid (HCl) containing a nominal 1 % mass fraction cetyl
34、trimethylammonium bromide. This solution, or the actual aqueous phase, may be used for the preparation of cationic emulsion samples. The solution of 1 % of cetyltrimethylammonium bromide should be prepared slightly above 25 C (but not higher than 30 C). Then it should be stored at a temperature of (
35、25 1) C before test. 5.3 Efficient rinsing agent Suitable solvent rinsing agents shall be used. 5.4 Ethanol 96 % minimum or methylated spirit 99 %. 6 Apparatus Usual laboratory apparatus and glassware, together with the following: 6.1 Sieve, conforming to ISO 565, stainless steel or brass, with a fr
36、ame diameter within the range of 75 mm to 100 mm and a mesh size of 0,500 mm. 6.2 Sieve, conforming to ISO 565, stainless steel or brass, with a frame diameter within the range of 75 mm to 100 mm and a mesh size of 0,160 mm. 6.3 Sieve pans, of corresponding diameter. 6.4 Balance, of sufficient capac
37、ity, capable of weighing to the nearest 1 g. 6.5 Balance, of sufficient capacity, capable of weighing to the nearest 0,01 g. 6.6 Balance, of sufficient capacity, capable of weighing to the nearest 0,001 g. 6.7 Conical flask, 200 ml capacity, with a ground stopper. 6.8 Conical flask, two, 250 ml capa
38、city with a ground stopper. 6.9 Conical flask, 500 ml capacity with a ground stopper (see 9.1). 6.10 Bottle, of sufficient capacity, with a screw-in stopper. 6.11 Container, of sufficient capacity. 6.12 Ventilated oven, capable of maintaining a temperature of (105 5) C around the sample. DIN EN 1429
39、:2013-08 EN 1429:2013 (E) 6 6.13 Desiccator. 6.14 Funnel. 7 Sampling The material under test shall be sampled in accordance with EN 58 and shall be prepared in accordance with EN 12594. The sample shall be divided into two portions; for referee purposes, both portions shall be tested (see Clause 11)
40、. 8 Procedure for the determination of residue on sieving 8.1 General Carry out the procedure under normal laboratory conditions between 18 C and 28 C. 8.2 Residue on the 0,500 mm sieve 8.2.1 Wash the 0,500 mm sieve (6.1) with rinsing agent (5.3) and then with ethanol or methylated spirit (5.4). 8.2
41、.2 Place the sieve on the sieve pan (6.3) and dry in the oven (6.12) for not less than 1 h. 8.2.3 After drying, allow the sieve and the sieve pan to cool within the desiccator (6.13). 8.2.4 Weigh the sieve and the sieve pan together. Record the mass, m1, to the nearest 0,01 g (6.5). 8.2.5 Wet the si
42、eve cloth with solution Sa (5.1) or Sc (5.2) as appropriate. 8.2.6 Drain the sieve thoroughly and place it on a funnel (6.14) which is mounted over the bottle (6.10). 8.2.7 Weigh the container (6.11) and record the mass, mC, to the nearest 1 g (6.4). 8.2.8 Weigh (1 000 5) g of emulsion into the cont
43、ainer and record the mass of emulsion, mE, 0,500, to the nearest 1 g (6.4). 8.2.9 Pour the emulsion through the wetted sieve and allow draining completely. Discard the first 30 ml or 40 ml of the filtered emulsion, in order to avoid any possible modification in the properties of the emulsion resulti
44、ng from the action of the Saor Scsolution. Clear as much as possible the container of the emulsion and reweigh the container. Record the mass, mC, Rto the nearest 1 g (6.4). If the emulsion does not pass through the sieve in 5 min at normal laboratory conditions, it is permitted to deviate from this
45、 procedure by pre-heating and testing the laboratory sample at (60 5) C and/or by diluting the emulsion with either Sasolution (5.1) or Scsolution (5.2) as appropriate, in order to determine residue on sieving. If a dilution is performed, an amount of (500 5) g, weighed to the nearest 1 g (6.4), of
46、Saor Scsolution shall be used. If heating is required, all precautions should be taken to minimize water loss and/or skin formation during this operation. DIN EN 1429:2013-08 EN 1429:2013 (E) 7 In case dilution is performed, adequate adaptations of the procedure and of calculations shall be performe
47、d and documented in the test report. Except for the determination of the residue on the 0,160 mm sieve (8.2), the filtered emulsion shall not be used for any other emulsion test. 8.2.10 Remove the bottle containing the filtered emulsion, and stopper it. NOTE The emulsion filtered in this way will be
48、 used to carry out the second part of the test (see 8.3, when required) and, if not diluted, to carry out all other tests on the emulsion. 8.2.11 Place the sieve on a funnel which is mounted over a 250 ml conical flask (6.8). Wash the residue on the sieve with solution Saor Scuntil the washings run clear. Finally wash with water. 8.2.12 Drain the sieve thoroughly and place it on the sieve pan. Dry in the oven (6.12) for at least 2 h and then cool in the desiccator (6.13) for about 30 min. 8.2.13 Weigh