1、August 2014DEUTSCHE NORM Normenausschuss Heiz- und Raumlufttechnik (NHRS) im DINPreisgruppe 11DIN Deutsches Institut fr Normung e. V. Jede Art der Vervielfltigung, auch auszugsweise, nur mit Genehmigung des DIN Deutsches Institut fr Normung e. V., Berlin, gestattet.ICS 97.120; 91.140.01; 35.240.99!%
2、1DM“2143342www.din.deDDIN EN 14908-3Firmenneutrale Datenkommunikation fr die Gebudeautomation undGebudemanagement Gebude-Netzwerk-Protokoll Teil 3: Kommunikation ber die Stromversorgungsleitungen;Englische Fassung EN 14908-3:2014Open Data Communication in Building Automation, Controls and Building M
3、anagement Control Network Protocol Part 3: Power Line Channel Specification;English version EN 14908-3:2014Rseau ouvert de communication de donnes pour lautomatisation, la rgulation et lagestion technique du btiment Protocole de contrle du rseau Partie 3: Spcifications des communications par courant
4、s porteurs;Version anglaise EN 14908-3:2014Alleinverkauf der Normen durch Beuth Verlag GmbH, 10772 BerlinErsatz frDIN EN 14908-3:2007-02www.beuth.deGesamtumfang 20 SeitenDIN EN 14908-3:2014-08 2 Nationales Vorwort Dieses Dokument (EN 14908-3:2014) wurde vom Technischen Komitee CEN/TC 247 Building en
5、vironment design“ erarbeitet, dessen Sekretariat vom SNV (Schweiz) gehalten wird. Das zustndige deutsche Gremium ist der Arbeitsausschuss NA 041-03-68 AA Gebudeautomation und -kommunikation (SpA CEN/TC 247/WG 4)“ im Normenausschuss Heiz- und Raumlufttechnik (NHRS) im DIN. Der englische Originaltext
6、dieser Europischen Norm wurde unverndert bernommen. Das Prsidium des DIN hat mit seinem Beschluss 1/2004 festgelegt, dass von dem in den Regeln der europischen Normungsarbeit von CEN/CENELEC verankerten Grundsatz, wonach Europische Normen in den drei offiziellen Sprachen Deutsch, Englisch und Franzs
7、isch verffentlicht werden, in begrndeten Ausnahme-fllen abgewichen und auf die deutsche Sprachfassung verzichtet werden kann. Die Genehmigung dafr hat die DIN-Geschftsleitung entsprechend ihren in Anlage 1 zu dem DIN-Rundschreiben A5/2004 festgelegten Kriterien fr die vorliegende Norm auf Antrag des
8、 NHRS als Ergebnis einer Einzelfallentscheidung erteilt, zumal bereits dieser Norm zugrunde liegende Papiere berwiegend in englischer Sprache auch von den deutschen Marktteilnehmern angewendet werden. Da sich die Anwender der vorliegenden Norm der englischen Sprache als Fachsprache bedienen, wird di
9、e englische Fassung der EN 14908-3 verffentlicht. Die Europische Norm EN 14908-3 ist Teil einer Serie von Normen, die sich mit dem Kommunikationssystem Control Network Protocol“ befassen, das auf der LonWorks-Technologie basiert. In dieser Serie werden sowohl Hardware als auch Software spezifiziert,
10、 die fr die Funktion des Kommunikationssystems notwendig sind. Des Weiteren wird es Teile geben, in der Funktionen, Profile und Konformittstests beschrieben werden. DIN EN 14908 besteht aus den folgenden Teilen unter dem Haupttitel Firmenneutrale Datenkommunikation fr die Gebudeautomation und Gebude
11、management: Teil 1: Datenprotokollschichtenmodell Teil 2: Kommunikation ber paarig verdrillte Leitungen Teil 3: Kommunikation ber die Stromversorgungsleitungen Teil 4: Kommunikation mittels Internet Protokoll (IP) Teil 5: Implementierungsrichtlinie nderungen Gegenber DIN EN 14908-3:2007-02 wurden fo
12、lgende nderungen vorgenommen: a) Redaktionelle berarbeitung (z. B. Verweisungen aktualisiert). Frhere Ausgaben DIN EN 14908-3: 2007-02 DIN EN 14908-3:2014-08 3 Nationaler Anhang NA (informativ) Begriffe und Definitionen Im Folgenden wird EN 14908-3:2014, Abschnitt 3 ins Deutsche bersetzt. Die Benenn
13、ung der folgenden Begriffe und Abkrzungen ist identisch mit der Benennung in der englischen Fassung. 3 Begriffe und Definitionen Fr die Anwendung dieses Dokuments gelten die Begriffe nach EN 14908-1:2014 und die folgenden Begriffe, insbesondere im Zusammenhang mit den Stromversorgungsleitungen und d
14、er Bitbertragungs-schicht nach Bild 1. 3.1 PL-Knoten (en: PL node) Benutzerknoten, der mit einem Versorgungsleitungsmedium an einer Abzweigung verbunden ist und die Anforderungen dieser Spezifikation erfllt 3.2 Netzkabel (en: line cord) Kabel, das nicht zum Stromversorgungsnetz gehrt, das aber einem
15、 Knoten, der sich auerhalb des Stromversorgungsnetzes befindet, ermglicht, an dieses Netz angeschlossen zu werden 3.3 Stromversorgungsnetz (en: power line network) Kommunikationsnetz, beruhend auf Stromverteilerleitungen (Stromleitungen“), vom letzten Verteiltransfor-mator aus bis hin zu einschlieli
16、ch allen Heimen, die von diesem Transformator gespeist werden, einschlielich aller Verdrahtungen in diesen Heimen 3.4 nicht netzbetriebener Knoten (en: non-network-powered node) kompatibler Knoten, der an das Stromversorgungsnetz angeschlossen ist, aber keine Leistung aus diesem Netzwerk bezieht DIN
17、 EN 14908-3:2014-08 4 Leerseite EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 14908-3 April 2014 ICS 35.240.99; 97.120; 91.140.01 Supersedes EN 14908-3:2006 English Version Open Data Communication in Building Automation, Controls and Building Management Control Network Protocol Part 3: Power
18、Line Channel Specification Rseau ouvert de communication de donnes pour lautomatisation, la rgulation et la gestion technique du btiment Protocole de contrle du rseau Partie 3: Spcifications des communications par courants porteurs Firmenneutrale Datenkommunikation fr die Gebudeautomation und Gebude
19、management Gebude-Netzwerk-Protokoll Teil 3: Kommunikation ber die Stromversorgungsleitungen This European Standard was approved by CEN on 12 April 2013. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the sta
20、tus of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, G
21、erman). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croa
22、tia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and U
23、nited Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No.
24、EN 14908-3:2014 E EN 14908-3: 2014 (E) 2 Contents Page Foreword . 3 Introduction 4 1 Scope . 5 2 Normative references . 5 3 Terms and definitions 5 4 General description 6 4.1 Electrical safety. 6 4.2 Functional partitioning of PL specification 6 5 Power Line Medium specifications . 7 5.1 Power . 7
25、5.2 Data channel 7 5.3 Physical and electrical specifications 7 5.4 Connectors and coupling 7 5.5 Signal coupling between phases 7 5.6 Surge protection and related devices 7 6 PL Node specifications 8 6.1 Compliance 8 6.2 Interface to MAC sub-layer 8 6.3 Word encoding 8 6.4 PL packet timing . 8 6.5
26、Transmitter characteristics 9 6.5.1 Carrier modulation 9 6.5.2 Waveform amplitude 9 6.5.3 Device coupling 10 6.5.4 Single phase coupling 10 6.5.5 Multiple phase coupling . 10 6.6 Receiver characteristics 10 6.6.1 Receive mode effective input impedance 10 6.6.2 Receiver performance 11 6.6.3 Receiving
27、 on a quiet line 12 6.6.4 Receiving with interference . 12 6.6.5 Receiving through a distorted channel 14 6.6.6 Receiving with impulsive noise . 14 Bibliography . 16 DIN EN 14908-3:2014-08 EN 14908-3: 2014 (E) 3 Foreword This document (EN 14908-3:2014) has been prepared by Technical Committee CEN/TC
28、 247 “Building Automation, Controls and Building Management”, the secretariat of which is held by SNV. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2014 and conflicting national standar
29、ds shall be withdrawn at the latest by October 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 14908
30、-3:2006. This European Standard is part of a series of standards for open data transmission in building automation, control and in building management systems. The content of this European Standard covers the data communications used for management, automation/control and field functions. EN 14908-3
31、 is part of a series of European Standards under the general title Control Network Protocol (CNP), which comprises the following parts: Part 1: Protocol stack; Part 2: Twisted pair communication; Part 3: Power line channel specification; Part 4: IP-Communication; Part 5: Implementation; Part 6: Appl
32、ication elements. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Mace
33、donia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. DIN EN 14908-3:2014-08 EN 14908-3: 2014 (E) 4 Introduction This part
34、of EN 14908 specifies the Control Network Power Line (PL) Channel and serves as a companion document to EN 14908-1:2014. Its purpose is to present the information necessary for the development of a PL physical network and nodes to communicate and share information over that network. This is one of a
35、 series of documents covering the various media that comprise the CNP standard. This part of EN 14908 covers the complete physical layer (OSI layer 1) including the interface to the Medium Access Control (MAC) Sub-Layer and the interface to the medium. It includes parameters specific to the PL chann
36、el type, even though the parameters may be controlled at an OSI layer other than layer 1. This part of EN 14908 also provides a set of guideline physical and electrical specifications for the power line environment as an aid in developing products for that environment. This part of EN 14908 has been
37、 prepared to provide mechanisms through which various vendors of building automation, control and of building management systems may exchange information in a standardised way. It defines communication capabilities. This part of EN 14908 is used by all involved in design, manufacture, engineering, i
38、nstallation and commissioning activities. The CNP specification model is based on the OSI 7-layer model Reference Model. There are also important extensions to the OSI Reference Model. Figure 1 shows the scope of this specification in reference to the entire CNP model. In this European Standard, onl
39、y the parts of the model relevant to power line communication are specified. Anything outside this boundary is covered in other parts of the standard. Similar specifications exist for other CNP media. Figure 1 Relationship of CNP 3 specification to the CNP 1 specification DIN EN 14908-3:2014-08 EN 1
40、4908-3: 2014 (E) 5 1 Scope This European Standard specifies all the information necessary to facilitate the exchange of data and control information over the power line medium for networked control systems in commercial Building Automation, Controls and Building Management. This European Standard es
41、tablishes a minimal set of rules for compliance. It does not rule out extended services to be provided, given that the rules are adhered to within the system. It is the intention of the standard to permit extended services (defined by users) to coexist. Certain aspects of this standard are defined i
42、n other documents. These documents are referenced where relevant. In the case where a referenced standard conflicts with this European Standard, this part of EN 14908 will prevail. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and ar
43、e indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 14908-1:2014, Open Data Communication in Building Automation, Controls and Building Management Contr
44、ol Network Protocol Part 1: Protocol Stack EN 50065-1, Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz Part 1: General requirements, frequency bands and electromagnetic disturbances EN 50065-2-1, Signalling on low-voltage electrical installations in the f
45、requency range 3 kHz to 148,5 kHz Part 2-1: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in residential, commercial and light industrial environments EN 50065-2-2, Signalling on low-voltage electri
46、cal installations in the frequency range 3 kHz to 148,5 kHz Part 2-2: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in industrial environments 3 Terms and definitions For the purposes of this docume
47、nt, the terms and definitions given in EN 14908-1:2014 and the following, specifically with the power line medium and physical layer shown in Figure 1, apply. 3.1 PL node user node attached to the power line medium at a tap that meets the requirements of this specification 3.2 line cord cable not pa
48、rt of the power line network that allows a node located away from the power line network to be connected to the network 3.3 power line network communication network based on power distribution lines (“power lines”), from the final distribution transformer to and including all homes served by that tr
49、ansformer, including all wiring in those homes DIN EN 14908-3:2014-08 EN 14908-3: 2014 (E) 6 3.4 non-network-powered node compatible node that attaches to the power line network but does not draw any power from the network 4 General description 4.1 Electrical safety This clause gives several recommendations related to safety concerns with respect to this European Standard. This discussion is not complete, nor does it address all possible safety issues. The desi